• Title/Summary/Keyword: psychoacoustic

Search Result 136, Processing Time 0.019 seconds

Construction of Sound Quality Index for the Vehicle HVAC System Using Regression Model and Neural Network Model (회귀모형과 신경망모형을 이용한 차량공조시스템의 음질 인덱스 구축)

  • Park, Sang-Gil;Lee, Hae-Jin;Sim, Hyun-Jin;Lee, Jung-Youn;Oh, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1443-1448
    • /
    • 2006
  • The reduction of the vehicle interior noise has been the main interest of NVH engineers. The driver's perception on the vehicle noise is affected largely by psychoacoustic characteristic of the noise as well as the SPL. In particular, the HVAC sound among the vehicle interior noise has been reflected sensitively in the side of psychology. Even though the HVAC noise is not louder than overall noise level, it clearly affects subjective perception in the way of making a diver become nervous or annoyed. Therefore, these days a vehicle engineer takes aim at developing sound quality as well as reduction of noise. In this paper, we acquired noises in the HVAC from many vehicles. Through the objective and subjective sound quality evaluation with acquiring noises caused by the vehicle HVAC system, the simple and multiple regression models were obtained for the subjective evaluation 'Pleasant' using the sound quality metrics. The regression procedure also allows you to produce diagnostic statistics to evaluate the regression estimates including appropriation and accuracy. Furthermore, the neural network model were obtained using three inputs(loudness, sharpness and roughness) of the sound quality metrics and one output(subjective 'Pleasant'). And then the models were compared with correlations between sound quality index outputs and hearing test results for 'Pleasant'. As a result of application of the sound quality index, the neural network was verified with the largest correlation of the sound quality index.

  • PDF

The Effects of Habituation and Sensitization on Psychophysiological Differentiation of Responses to Auditory Stimulation with Automobile Horns

  • Estate M. Sokhadze;Sohn, Jin-Hun
    • Science of Emotion and Sensibility
    • /
    • v.3 no.2
    • /
    • pp.17-28
    • /
    • 2000
  • Psychoacoustic characteristics of automobile horns play significant role in resulting subjective evaluation and psychphysiological reactions. However, comparison and differentiation of physiological responses to commercially available horns is a complicated task due to the small contrast in technical features of horns and the influence of such processes as habituation on physiological outcome with the increased number of auditory stimulation trials. In a study on 10 college students, there was performed comparative analysis of reactivity of physiological responses mediated by central and autonomic nervous systems in order to identify the role of habituation on decrement of psychophysiological responsivity and assess the ability to differentiate subjectively most and least preferred, as well as most and least appropriate horns according to physiological manifestations. The EEG and autonomic responses to 7 automobile horns were analyzed during 3 blocks of trials, with varying order of stimuli and changed acoustic parameters of horns in each block. Thus, responses were analyzed for totally 21 trials of auditory stimulation. It was shown that electrodermal and cardiovascular responses have different reactivity patterns to repeated stimulation: skin conductance measures habituated, cardiac reactivity showed no signs of habituation, and the vascular response demonstrated sensitization. The temporal EEG exhibited marked habituation of fast beta band power, while alpha-blocking effect did not habituate during the course of experiment. Differentiation of physiological responses of most and least preferred and appropriate horns was possible in our study, however, some cardiovascular reactivity measures differentiated during the entire course of the experiment, while EEG and electrodermal parameters showed significant differences only during first block of trials, and were later affected by the habituation.

  • PDF

Acoustic Analysis of Normal and Vocal Pathologic Voice Using Dr. Speech Science (Dr. Speech Science를 이용한 정상 및 후두질환 환자의 음향분석)

  • Lee, Hyung-Seok;Tae, Kyung;Jang, Kyung-Jin;Kim, Kyung-Woo;Kim, Kyung-Rae;Park, Chul-Won
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.8 no.2
    • /
    • pp.166-172
    • /
    • 1997
  • Background : For example, aerodynamic study, vibratory study, acoustic study, neuro-muscular test and psychoacoustic evaluation, a number of objective methods are now available for assessing pathologic voice change. They help to differentiate pathologic condition from normal condition and to monitor pathologic and aging change. These laboratory analyses are used commonly to monitor speech therapy and to follow a patient's recovery after surgery. Objectives : We investigated the values of jitter, shimmer and NNE of normal person and hoarseness patients in Korea. The values of Jitter and shimmer might be meaningful parameters distinguishing pathologic vibration from normal and recovery after surgery. Materials and Methods : Statistical significance between normal control and 48 subjects taken microlaryngeal surgery were compared with Dr. speech science program that is computerized system for acoustic analysis of voice production employed to determine vocal characteristics of pitch perturbation(jitter) and amplitude perturbation(shimmer). Results : The mean normal values of jitter and shimmer were 0.226${\pm}$0.110(%), 2.200${\pm}$0.421(%) in male and 0.164${\pm}$0.060(%), 2.063 ${\pm}$0.575(%) in female. In patients with vocal nodule, the preoperative and postoperative values of jitter and shimmer were valueless. In patients with vocal polyps, the preoperative and postoperative values of jitter and shimmer were valuable. Conclusion : Dr. speech science program was effective to monitor laryngeal disease and aging changes.

  • PDF

Multi-Modal Biometries System for Ubiquitous Sensor Network Environment (유비쿼터스 센서 네트워크 환경을 위한 다중 생체인식 시스템)

  • Noh, Jin-Soo;Rhee, Kang-Hyeon
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.44 no.4 s.316
    • /
    • pp.36-44
    • /
    • 2007
  • In this paper, we implement the speech & face recognition system to support various ubiquitous sensor network application services such as switch control, authentication, etc. using wireless audio and image interface. The proposed system is consist of the H/W with audio and image sensor and S/W such as speech recognition algorithm using psychoacoustic model, face recognition algorithm using PCA (Principal Components Analysis) and LDPC (Low Density Parity Check). The proposed speech and face recognition systems are inserted in a HOST PC to use the sensor energy effectively. And improve the accuracy of speech and face recognition, we implement a FEC (Forward Error Correction) system Also, we optimized the simulation coefficient and test environment to effectively remove the wireless channel noises and correcting wireless channel errors. As a result, when the distance that between audio sensor and the source of voice is less then 1.5m FAR and FRR are 0.126% and 7.5% respectively. The face recognition algorithm step is limited 2 times, GAR and FAR are 98.5% and 0.036%.

Implementation of MP3 decoder with TMS320C541 DSP (TMS320C541 DSP를 이용한 MP3 디코더 구현)

  • 윤병우
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.4 no.3
    • /
    • pp.7-14
    • /
    • 2003
  • MPEG-1 audio standard is the algorithm for the compression of high-qualify digital audio signals. The standard dictates the functions of encoder and decoder pair, and includes three different layers as the complexity and the performance of the encoder and decoder. In this paper, we implemented the real-time system of MPEG-1 audio layer III decoder(MP3) with the TMS320C541 fixed point DSP chip. MP3 algorithm uses psycho-acoustic characteristic of human hearing system, and it reduces the amount of data with eliminating the signals hard to be heard to the hearing system of human being. It is difficult to implement MP3 decoder with fixed Point DSP because of it's broad dynamic range. We implemented realtime system with fixed DSP chip by using weighted look-up tables to reduce the amount of calculation and solve the problem of broad dynamic range.

  • PDF

An Objective Speech Quality Measure using Masking Effect under Digital Mobile Telephone Network Environment (디지털 이동통신망 환경 하에서 마스킹 효과를 이용한 객관적 음질 평가 척도)

  • 김광수;김민정;석수영;정호열;정현일
    • Journal of Korea Multimedia Society
    • /
    • v.5 no.4
    • /
    • pp.405-414
    • /
    • 2002
  • In this paper, we propose a new objective speech quality measure using noise masking threshold for speech quality assessment of mobile telephone network environments, and verify the effectiveness of the proposed method through the experiments. For such a purpose, well known objective speech quality measures such as BSD and PSQM are first evaluated for digital mobile telephone network environments. However, these conventional methods does not have good performance under mobile networks environments compared to literary results. To be mote effective objective speech quality measure under mobile telephone environments, the proposed method employs human psychoacoustic masking effect. The DMOS, instead of MOS, is used as a subjective speech quality measure for performance evaluation. The performance comparison are carried out with speech data collected from digital mobile telephone environments. As results, the proposed measure have and average 4% higher performance, in terms of correlation, than existing objective speech quality measures such as BSD and PSQM.

  • PDF

Effects of reverberation time on binaural Korean monosyllabic word recognition in normal hearing subjects (잔향시간이 양이를 사용한 한국어 단음절 인지에 미치는 영향)

  • Lim, Dukhwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.6
    • /
    • pp.678-682
    • /
    • 2021
  • Reverberation Time (RT) with noise levels can affect speech recognition ability in a listening environment. The degree of influence may depend on reverberation times and modes of binaural hearing. In this study, Korean monosyllabic Word Recognition Scores (WRS) were investigated in 10 young normal hearing subjects under binaural conditions. The RT of 3.4 s and signal to noise ratio of 0 dB were used at 55 dB HL for diotic (noise with the same phase) and dichotic (noise with the fixed phase difference, π) conditions. The improvement in WRS was noted in dichotic hearing (p < 0.05) while the similar trend was not observed in diotic hearing. This data may be useful in analyzing psychoacoustic effects of RTs under noisy conditions.

A preliminary study of sound quality evaluation of cochlear implant users (인공와우 사용자의 심리음향적 음질평가 예비연구)

  • Bahng, Junghwa;Oh, Soo Hee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.1
    • /
    • pp.45-51
    • /
    • 2022
  • Sound quality evaluation is one of the psychoacoustic methods to measure subjective judgements for sound color. The purpose of this study is to investigate sound quality benefits of bimodal users by comparing sound quality scores between bimodal hearing condition and unilateral cochlear implant(CI) condition as a preliminary study. Thirteen bimodal users and seven unilateral CI users were participated in this study. Audiologists performed pure tone and speech audiometry and measured functional gain and real-ear insertion gain. Subjective assessment of sound quality was followed with four sounds including violin sound, male and female voices, and refrigerator noise. Participants judged the sound quality with six sound quality index. Bimodal users showed mean 0.8 points more sound quality improvements in bimodal condition than unilateral CI condition. Group comparison between bimodal and unilateral CI users showed no differences. A follow-up study of sound quality tools and methods should be considered to evaluate subjective bimodal benefits of cochlear implant users.

A Study of the Sound Quality Characteristics for Environmental Noise Assessments Parameters (음질을 고려한 환경소음 평가 인자의 기여도분석에 관한 연구)

  • Jo Kyoung-Sook;Cho Yeon;Hwang Dae-Sun;Hur Deog-Jae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.3
    • /
    • pp.129-136
    • /
    • 2006
  • For the environmental noise assessments. A weighted equivalent noise level (LeqA) is used to measure the time varying environmental noise. However, it is not appropriately reflect various environmental noise features and human emotions. The human perception of the noise is affected largely by the psychoacoustic characteristics of noise as well as the sound pressure level In this study, the effective factors of noise qualify are analyzed using the subjective assessment and statistical analysis of environmental noise, such as road traffic noise. construction site noise, noise in daily living. and other. The analysis methodology is composed to three steps as follows : firstly, the values of the sound qualify metrics of various noise sources were analyzed. And to classify the noise sources, we conducted a cluster analysis using sound quality metrics. Secondly, subjective jury testing was carried out using the methods of paired comparisons and semantic differential. Finally, the correlation between the subjective parameters and the noise quality metrics were analyzed. As a result. the human perception characteristics of the various environmental noise are described in some physical parameters of the noise qualify metrics.

The Phoniatric Evaluation of the Effect of the Laryngomicrosurgery for the Laryngeal Polyps and the Nodules (성대폴립및 결절의 치료 효과에 대한 음성의학적 고찰)

  • 김기령;홍원표;김광문;이경재;정태영;이명호
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1983.05a
    • /
    • pp.8.2-9
    • /
    • 1983
  • Recently, the laryngomicrosurgery has been done for the removal of benign laryngeal mass and for the improvement of voice. For the evaluation of the effect of the treatment, there must be any objective method such as aerodynamic study, vocal fold vibration study, acoustic analysis, psycho-acoustic evaluation and the neuro-muscular study. The authors evaluated the phoniatric effect of the laryngomicrosurgery for the patients of 15 laryngeal polyps and 9 laryngeal nodules, who received pre-op. and post-op. vocal function study from Jun. 1981 to Mar. 1983. The results obtained were as follows ; 1) The post-op. mean value of the maximum phonation time was increased 40 % in the unilateral polyps, 62 % in the bilateral nodules and 18 % in the unilateral nodules. 2) The post-op. mean value of the phonation quotient was decreased 25 % in comparison with pre-op. value in the case of the bilateral polyps, 26 % in the unilateral polyps, 55 % in the bilateral nodules and 12 % in the unilateral nodules. 3) The post-op. mean value of the mean air flow rate was decreased 27 % in comparison with the pre-op. value in the case of the bilateral polyps, 25 % in the unilateral polyps, 65 % in the bilateral nodules, 25 % in the unilateral nodules. 4) The glottic chink of the 10 cases of polyps among the 11 cases were disappeared, and the glottic chink of the 5 cases of nodules among 7 cases were also disappeared after surgery. 5) The pre-op. hoarseness of the 10 cases of polyps among the pre-op. hoarseness of the 11 cases of polyps were changed to clear and the 3 cases of nodules were also changed to clear.

  • PDF