• Title/Summary/Keyword: proximal methods

Search Result 805, Processing Time 0.025 seconds

The Differences of Fixation Method in Proximal Chevron Osteotomy for Hallux Valgus: K-Wire, Cannulated Screw, Plate (무지외반증에서 근위 갈매기형 절골술 후 고정 방법에 따른 차이: K-강선, 유관나사, 금속판)

  • Kim, Taik-Seon;Kim, Hak-Jun;Park, Young-Hwan;Lim, Hyung-Tae
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.2
    • /
    • pp.62-67
    • /
    • 2011
  • Purpose: The authors evaluated the differences between K-wires and Cannulated screw, plate for fixing the proximal metatarsal chevron osteotomy of moderate and severe hallux valgus. Materials and Methods: There were 62 patients (79 feetz) who were moderate and severe degree hallux valgus according to the classification of Mann. They all got the proximal chevron osteotomy when correcting the deformity. We divided the patients into 4 groups, Two K-wire fixed group as A, one cannulated screw fixed group as B. Two cannulated screw fixed group as C, Plate fixed group as D, Group A were patients (26 feet) and Group B were patients z(9 feet), Group C were patients (31 feet) and Group D were patients (13 feet). Preoperative, postoperative and follow-up hallux valgus angle (HVA) and intermetatarsal angle (IMA) were measured for each patient. ANOVA test and Student t-test were done for statistical analysis. Results: Mean follow up period was 43.8 months (range: 12~82 months). Preoperative mean IMA was $16.4{\pm}3.5$, $17.7{\pm}11.3$, $17.3{\pm}5.9$ and $16.6{\pm}2.3$ degrees in respectively group A, B, C, D. Immediate postoperative mean IMA was $5.6{\pm}3.4$, $7.3{\pm}4.4$, $7.6{\pm}4.4$ and $6.7{\pm}2.8$ degrees in respectively group A, B, C, D. The final mean IMA was $8.9{\pm}4.5$, $15.2{\pm}7.5$, $10.3{\pm}4.4$ and D $7.7{\pm}3.5$ degrees in respectively group A, B, C, D. There were significant statistical increase in final mean IMA of group B and C (p<0.05). Conclusion: The IMA was significantly increased in the group which used one or two cannulated screw for fixation on follow up, therefore more caution should be needed when using one or two cannulated screw fixation technique after proximal chevron osteotomy.

Efficacy of Additive Trans-cuff Augmentation Sutures for Proximal Humeral Fractures Stabilized by Locking Plates in Elderly Patients

  • Cho, Nam Su;Shim, Hee Seok;Lee, Sang Hyeon;Jeon, Jong Wook;Rhee, Yong Girl
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.2
    • /
    • pp.68-74
    • /
    • 2015
  • Background: The purpose of our study was to evaluate the functional and radiologic outcomes of additive augmentation sutures through rotator cuff for proximal humeral fractures stabilized locking plate in elderly patients. Methods: We enrolled 74 patients over the age of 60 years who received internal fixation using locking plates for proximal humeral fractures. Of these, 50 patients had additive augmentation sutures through rotator cuff. The mean age at the time of surgery was 72.1 years (range, 60-89 years), and the mean follow-up period was 17.5 months (range, 12-62 months). The humeral neck-shaft angle and humeral head height were used as radiological markers to assess the effect of additive augmentation sutures through rotator cuff. We allocated the patients who received additive augmentation sutures into group A and those who did not into group B. Results: At the final follow-up, the mean Korean Showlder Society score and Constant scores were $88.96{\pm}12.1$ and $86.6{\pm}11.9$, respectively, in group A and $86.21{\pm}11.8$ and $85.3{\pm}11.7$, respectively, in group B (p=0.368, 0.271). At the final follow-up, the mean loss in humeral neck-shaft angle from the time of immediate postoperative measurement was $1.6^{\circ}$ in group A and $4.8^{\circ}$ in group B, whereas the mean loss in humeral head height was 0.82 mm in group A and 0.52 mm in group B (p=0.029, 0.178). Conclusions: The surgical outcomes of internal fixation using locking plates for proximal humeral fractures were clinically and radiologically good in elderly patients over the age of 60 years without any observable complications. Further, the loss of humeral head shaft angle at the final follow-up from its initial postoperative measurement was significantly smaller in patients who received an additive augmentation suture than in those who did not. Thus, we conclude that augmentation sutures are a beneficial option for elderly patients that clinicians can consider at the time of surgical decision making.

The Results of Ender Nailing for the Proximal Humerus Fractures - Radiological Evaluation - (상완골 근위부 골절의 Erlder 정을 이용한 치료 결과-방사선학적 분석 -)

  • Park Jin Soo;Chung Moon Sang;Yoon Kang Sub;Baek Goo Hyun;Lee Ji Ho;Kang Seung Baek;Kim Dong Wook
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.2
    • /
    • pp.187-198
    • /
    • 1999
  • Purpose: The authors compared the results of Ender nailing for the proximal humerus fractures with those of the conservative methods radiographically. Materials and Method: Nine patients(mean age: 69 years.) received Ender nailing, and the other nine patients, conservative treatments(mean age: 73 years). All fractures were 2 part fractures. The Ender nails were inserted either through posterior elbow approach or transepicondylar approach. A simple Velpeau bandage was applied to the conservative treatment group. The average follow-up was 15 months. Results: The initial status of the anatomical reduction, i.e., the values of the medial shift, overlapping and the varus agulation, were little changed at follow-up radiographs in both the Ender nailing group and the conservative treatment group. There was no significant difference for the status of anatomical reduction between the Ender nailing group and the conservative treatment group. The stability of fixation by Ender nails, i.e., the degree of fanning out of the nails was poor in most cases. Not a few problems/complications happened in cases of Ender nailing group; back­ing out of the nail in three cases, penetration of the nails into the humeral heads in 3, fractures or cracking of the humerus around the nail insertion area in 4 and reduction loss in one. Conclusion: We could not get better results with the use of Ender nail. We use no longer Ender nails for the proximal humerus fractures. Further studies are needed for the better option for the proximal humerus fractures.

  • PDF

Surgical Experience of Paraclinoidal Aneurysms (상상돌기 주위 동맥류의 수술적 치험)

  • Kang, Hyung Gon;Jo, Chul Min;Huh, Jae Teack
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.203-210
    • /
    • 2001
  • Objective : Paraclinoidal aneurysms termed that aneurysms arising from proximal internal carotid artery(ICA) between the site of emergence of the carotid artery from roof of the cavernous sinus and origin of the posterior communicating artery(PCoA). These aneurysms pose conceptual and technical surgical problems with regard to acquisition of proximal control and safe intracranial exposure. The efficiency of surgical technique according to the location of paraclinoidal aneurysm was studied for minimal exposure. Materials and Methods : Over the past four years, the authors treated surgically 171 cases of cerebral aneurysm, among them ten patients were paraclinoidal aneurysms with two patients unruptured aneurysms. Mean age was 47 years old, and all patients were female. Three patients were proximal posterior carotid artery wall aneurysms(one large, one giant), four patients carotid-ophthalmic artery aneurysms and three patients superior hypophyseal artery aneurysms. Results : There could be done clip in all cases, there were no deaths and no complication. And no patient developed sustained neurological deficits including visual function except hydrocephalus in one case. Four patients complained of visual disturbance but two patients had recovery after postoperation and two patient were not longer to bad. Conclusion : Our recent experience suggests that preoperative scrutiny of diagnostic angiography allows classification of all paraclinoidal aneurysms regardless of size and surgical technique which this classification has focused on operative approaches unique to each aneurysm projection was helpful to improve the operative outcome with good visual function and to shorten the operative time.

  • PDF

The Fate of Proximal Junctional Vertebral Fractures after Long-Segment Spinal Fixation : Are There Predictable Radiologic Characteristics for Revision surgery?

  • Jang, Hyun Jun;Park, Jeong Yoon;Kuh, Sung Uk;Chin, Dong Kyu;Kim, Keun Su;Cho, Yong Eun;Hahn, Bang Sang;Kim, Kyung Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.3
    • /
    • pp.437-446
    • /
    • 2021
  • Objective : To investigate the radiographic characteristics of the uppermost instrumented vertebrae (UIV) and UIV+1 compression fractures that are predictive of revision surgery following long-segment spinal fixation. Methods : A total 27 patients who presented newly developed compression fracture at UIV, UIV+1 after long segment spinal fixation (minimum 5 vertebral bodies, lowest instrumented vertebra of L5 or distal) were reviewed retrospectively. Patients were divided into two groups according to following management : revisional surgery (group A, n=13) and conservative care (group B, n=14). Pre- and postoperative images, and images taken shortly before and after the occurrence of fracture were evaluated for radiologic characteristics Results : Despite similar degrees of surgical correction of deformity, the fate of the two groups with proximal junctional compression fractures differed. Immediately after the fracture, the decrement of adjacent disc height in group A (32.3±7.6 mm to 23.7±8.4 mm, Δ=8.5±6.9 mm) was greater than group B (31.0±13.9 mm to 30.1±15.5 mm, Δ=0.9±2.9 mm, p=0.003). Pre-operative magnetic resonance imaging indicated that group A patients have a higher grade of disc degeneration adjacent to fractured vertebrae compared to group B (modified Pfirrmann grade, group A : 6.10±0.99, group B : 4.08±0.90, p=0.004). Binary logistic regression analysis indicated that decrement of disc height was the only associated risk factor for future revision surgery (odds ratio, 1.891; 95% confidence interval, 1.121-3.190; p=0.017). Conclusion : Proximal junctional vertebral compression fractures with greater early-stage decrement of adjacent disc height were associated with increased risk of future neurological deterioration and necessity of revision. The condition of adjacent disc degeneration should be considered regarding severity and revision rate of proximal junctional kyphosis/proximal junction failures.

The Usefulness of Extradural Anterior Clinoidectomy for Low-Lying Posterior Communicating Artery Aneurysms : A Cadaveric Study

  • Hyoung Soo Byoun;Kyu-Sun Choi;Min Kyun Na;Sae Min Kwon;Yong Seok Nam
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.4
    • /
    • pp.411-417
    • /
    • 2024
  • Objective : To confirm the usefulness of the extradural anterior clinoidectomy during the clipping of a low riding posterior communicating artery (PCoA) aneurysm through cadaver dissection. Methods : Anatomic measurements of 12 adult cadaveric heads (24 sides total) were performed to compare the microsurgical exposure of the PCoA and internal carotid artery (ICA) before and after clinoidectomy. A standard pterional craniotomy and transsylvian approach were performed in all cadavers. The distance from the ICA bifurcation to the origin of PCoA (D1), pre-anterior clinoidectomy distance from the ICA bifurcation to tentorium (D2), post-anterior clinoidectomy distance from the ICA bifurcation to tentorium (D3), pre-anterior clinoidectomy distance from the tentorium to the origin of PCoA (D4) and post-anterior clinoidectomy distance from the tentorium to the origin of PCoA (D5) and the distance of the ICA obtained after anterior clinoidectomy (D6) were measured. We measured the precise thickness of the blade for the Yasargil clip with a digital precision ruler to confirm the usefulness of the extradural anterior clinoidectomy. Results : Twenty-four sites were dissected from 12 cadavers. The age of the cadavers was 79.83±6.25 years. The number of males was the same as the females. The space from the proximal origin of the PCoA to the preclinoid-tentorium (D4) was 1.45±1.08 mm (max, 4.01; min, 0.56). After the clinoidectomy, the space from the proximal origin of the PCoA to the postclinoid-tentorium (D5) was 3.612±1.15 mm (max, 6.14; min, 1.83). The length (D6) of the exposed proximal ICA after the extradural clinoididectomy was 2.17±1.04 mm on the lateral side and 2.16±0.89 mm on the medial side. The thickness of the Yasargil clip blade used during the clipping surgery was 1.35 mm measured with a digital precision ruler. Conclusion : The proximal length obtained by performing an external anterior clinoidectomy is about 2 mm, sufficient for proximal control during PCoA aneurysm surgery, considering the thickness of the aneurysm clips. In a subarachnoid hemorrhage, performing an extradural anterior clinoidectomy could prevent a devastating situation during PCoA aneurysm clipping.

Limb Salvage Surgery with Tumor Prosthesis for the Malignant Bone Tumors Involving the Proximal Femur (대퇴골 근위부 악성 골종양 환자에서 종양 대치물을 이용한 사지 구제술)

  • Chun, Young Soo;Baek, Jong Hun;Lee, Seung Hyuk;Lee, Chung Hwan;Han, Chung Soo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.20 no.1
    • /
    • pp.7-13
    • /
    • 2014
  • Purpose: As well as patient survival, the restoration of postoperative function such as ambulation is important in limb salvage operations for treatment of malignant bone tumors involving the proximal femur. The authors analyzed clinical outcomes of limb salvage operations using tumor prostheses for metastatic or primary malignant bone tumors in the proximal femur. Materials and Methods: From February 2005 to January 2014, 20 cases (19 patients) with malignant bone tumor involving the proximal femur with pain or complicated pathologic fracture were treated with segmental resection and limb salvage operations with tumor prostheses. Mean age was 63.1 years (range 35-86). Fourteen patients were male and six ones were female. The mean follow-up period was 20 months (1-94 months). There were 15 cases of metastatic bone tumor, 4 cases of osteosarcoma, and 1 case of multiple myeloma. The primary tumors of the metastatic bone tumors included 4 lung cancers, 3 hepatocellular carcinomas, and 3 renal cell carcinomas. Other primary tumors were breast cancer, thyroid cancer, colon cancer, prostate cancer, and malignant spindle cell tumor, each in 1 case. Modular tumor prostheses were used in all cases; (Kotz's$^{(R)}$ Modular Tumor prosthesis (Howmedica, Rutherford, New Jersey) in 3 cases, MUTARS$^{(R)}$ proximal femur system (Implantcast, Munster, Germany) in 17 cases). Perioperative pain was assessed with Visual Analogue Scales (VAS). Postoperative functional outcome was assessed with Musculoskeletal Tumor Society (MSTS) grading system. Results: Out of 20 cases (19 patients), 11 cases (10 patients) survived at the last follow-up. Average postoperative survival of the 9 deceased patients was 10.1 months (1-38 months). VAS score improved from pre-operative average of 8.40 (5-10) to 1.35 (0-3) after operation. Average postoperative MSTS function score was 19.65 (65.50%, 7-28). The associated complications were 2 local recurrences, 3 hematomas, 3 infections, 2 scrotal swellings, and 1 dislocation. There was no case of periprosthetic fracture or loosening. Conclusion: Limb salvage operation with tumor prosthesis is an appropriate treatment for early pain reduction and functional restoration in malignant bone tumors in the proximal femur with pain an/or complicated pathologic fractures.

The Efficacy of Proximal Esophageal 24-hour pH Monitoring in Infants with Chronic Cough (만성기침을 동반한 영아에서 상부 식도 24시간 pH 검사의 유용성)

  • Kim, Yun Hee;Kim, Ja Kyoung;Kim, Jung Hee;Lim, Dae Hyun;Son, Byong Kwan
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.12
    • /
    • pp.1242-1247
    • /
    • 2003
  • Purpose : Gastroesophageal reflux disease(GERD) is known as one of the most common causes of chronic cough, especially in children. The purpose of this study is to evaluate the efficacy of parameters from proximal esophageal 24-hr pH monitoring through its comparison with those of distal esophageal 24-hr pH monitoring that we generally use for diagnosis of GERD. Methods : We performed chest CT scans to find out the cause of chronic cough in infants with no clinical manifestation suggesting GERD. Then, in case that they had air space consolidation in posterior segment of both upper lobes and superior segment of both lower lobes(dependent position), we performed proximal and distal esophageal 24-hr pH monitoring. Results : The proximal and distal pH monitoring were performed in 17 infants(male 12; female five). The patients with positive pathologic reflux in proximal esophagus were 15 of 17(88.2%) and in distal esophagus were four of 17(23.5%). Reflux index and the total number of reflux episodes were statistically significantly lower in the proximal than in the distal esophagus(P<0.05). There was no correlation between each parameters of proximal and distal esophageal 24-hr pH monitoring. Conclusion : This study suggests that proximal esophageal 24-hr pH monitoring can be used as a very useful diagnostic tool in infants with chronic cough in which there are suspicions that it resulted from aspiration due to GERD.

STOCHASTIC GRADIENT METHODS FOR L2-WASSERSTEIN LEAST SQUARES PROBLEM OF GAUSSIAN MEASURES

  • YUN, SANGWOON;SUN, XIANG;CHOI, JUNG-IL
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.25 no.4
    • /
    • pp.162-172
    • /
    • 2021
  • This paper proposes stochastic methods to find an approximate solution for the L2-Wasserstein least squares problem of Gaussian measures. The variable for the problem is in a set of positive definite matrices. The first proposed stochastic method is a type of classical stochastic gradient methods combined with projection and the second one is a type of variance reduced methods with projection. Their global convergence are analyzed by using the framework of proximal stochastic gradient methods. The convergence of the classical stochastic gradient method combined with projection is established by using diminishing learning rate rule in which the learning rate decreases as the epoch increases but that of the variance reduced method with projection can be established by using constant learning rate. The numerical results show that the present algorithms with a proper learning rate outperforms a gradient projection method.

SHADOWING PROPERTY FOR ADMM FLOWS

  • Yoon Mo Jung;Bomi Shin;Sangwoon Yun
    • Journal of the Korean Mathematical Society
    • /
    • v.61 no.2
    • /
    • pp.395-408
    • /
    • 2024
  • There have been numerous studies on the characteristics of the solutions of ordinary differential equations for optimization methods, including gradient descent methods and alternating direction methods of multipliers. To investigate computer simulation of ODE solutions, we need to trace pseudo-orbits by real orbits and it is called shadowing property in dynamics. In this paper, we demonstrate that the flow induced by the alternating direction methods of multipliers (ADMM) for a C2 strongly convex objective function has the eventual shadowing property. For the converse, we partially answer that convexity with the eventual shadowing property guarantees a unique minimizer. In contrast, we show that the flow generated by a second-order ODE, which is related to the accelerated version of ADMM, does not have the eventual shadowing property.