• Title/Summary/Keyword: proximal methods

Search Result 768, Processing Time 0.028 seconds

Is Adjacent Segment Disease More Frequent in Proximal Levels in Comparison with Distal Levels? Based on Radiological Data of at Least 2 Years Follow Up with More than 2 Level Thoracolumbar Fusions

  • Kim, Jung-Ho;Ryu, Dal-Sung;Yoon, Seung-Hwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.5
    • /
    • pp.603-609
    • /
    • 2019
  • Objective : The purpose of this retrospective study was to determine which of the proximal adjacent segment disease (ASD) and distal ASD was more prevalent and what parameters is more related to ASD in proximal levels and distal levels after more than 2 levels fusions. Methods : The medical records were reviewed retrospectively for 856 cases. A total of 66 cases of ASD were enrolled. On preop magnetic resonance imaging, disc degeneration was measured at the upper and lower parts of surgically treated levels and confirmed by the commonly used Pfirrmann grade. Segmental flexibility in sagittal plane was embodied in segment range of motion (ROM) obtained through flexion and extension X-ray before surgery. Coronal angle was recorded as methods Cobb's angle including fusion levels preoperatively. For the comparison of categorical variables between two independent groups, the chi-square test and Fisher exact test were performed. Results : Proximal ASD and distal ASD were 37/856 (4.32%) and 29/856 (3.39%), respectively. The incidence of proximal ASD was relatively high but insignificant differences. In comparison between ASD group and non ASD group, proximal Pfirmman was higher in proximal ASD and distal Pfirmman was higher in distal ASD group (p=0.005, p<0.008, respectively). However, in the ROM, proximal ROM was higher in proximal ASD, but distal ROM was not different between the two groups (p<0.0001, p=0.995, respectively). Coronal angle was not quite different in both groups (p=0.846). Conclusion : In spite of higher frequency in ASD in proximal level in spinal fusion, it is not clear that incidence of ASD in proximal level is not higher than that of distal ASD group in more than 2 level thoracolumbar fusions. Not only Pfirrmann grade but also proximal segmental ROM is risk factor for predicting the occurrence of ASD in patients more than 2 level of thoracolumbar spine fusion operation excluding L5S1.

Pterional or Subfrontal Access for Proximal Vascular Control in Anterior Interhemispheric Approach for Ruptured Pericallosal Artery Aneurysms at Risk of Premature Rupture

  • Park, Jaechan
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.2
    • /
    • pp.250-256
    • /
    • 2017
  • Objective : Cases of a ruptured pericallosal artery aneurysm with a high risk of intraoperative premature rupture and technical difficulties for proximal vascular control require a technique for the early and safe establishment of proximal vascular control. Methods : A combined pterional or subfrontal approach exposes the bilateral A1 segments or the origin of the ipsilateral A2 segment of the anterior cerebral artery (ACA) for proximal vascular control. Proximal control far from the ruptured aneurysm facilitates tentative clipping of the rupture point of the aneurysm without a catastrophic premature rupture. The proximal control is then switched to the pericallosal artery just proximal to the aneurysm and its intermittent clipping facilitates complete aneurysm dissection and neck clipping. Results : Three such cases are reported : a ruptured pericallosal artery aneurysm with a contained leak of the contrast from the proximal side of the aneurysm, a low-lying ruptured pericallosal artery aneurysm with irregularities on its proximal wall, and a multilobulated ruptured pericallosal artery aneurysm with the parasagittal bridging veins hindering surgical access to the proximal parent artery. In each case, the proposed combined pterional-interhemispheric or subfrontal-interhemispheric approach was successfully performed to establish proximal vascular control far from the ruptured aneurysm and facilitated aneurysm clipping via the interhemispheric approach. Conclusion : When using an anterior interhemispheric approach for a ruptured pericallosal artery aneurysm with a high risk of premature rupture, a pterional or subfrontal approach can be combined to establish early proximal vascular control at the bilateral A1 segments or the origin of the A2 segment.

PROXIMAL POINTS METHODS FOR GENERALIZED IMPLICIT VARIATIONAL-LIKE INCLUSIONS IN BANACH SPACES

  • He, Xin-Feng;Lou, Jian;He, Zhen
    • East Asian mathematical journal
    • /
    • v.28 no.1
    • /
    • pp.37-47
    • /
    • 2012
  • In this paper, we study generalized implicit variational-like inclusions and $J^{\eta}$-proximal operator equations in Banach spaces. It is established that generalized implicit variational-like inclusions in real Banach spaces are equivalent to fixed point problems. We also establish relationship between generalized implicit variational-like inclusions and $J^{\eta}$-proximal operator equations. This equivalence is used to suggest a iterative algorithm for solving $J^{\eta}$-proximal operator equations.

Evaluation of the proximal contact and comparison of methods for measuring in normal dentition (건강한 자연치열에서 인접면 접촉의 평가 및 측정방법에 따른 비교분석)

  • Ji-Eun Kim;Cheong-Hee Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.198-203
    • /
    • 2023
  • Purpose. The aim of this study was to evaluate the proximal contact with a dental floss compared to a celluloid strip and a metal strip in normal dental arch and investigate what the most effective method for measuring is. Materials and methods. The subjects of this study was consisted with 20 healthy adults (10 males and 10 females) who had normal dentition. A dentist with more than 5 years of clinical experience evaluated the proximal contacts using a dental floss method, a celluloid strip method, and a metal strip method. Statistical analysis were performed by the use of Mann-Whitney U test. A P-value < .05 was considered statistically significant in all analysis. In addition, in the evaluation of proximal contact using a dental floss, the measurement of proximal contact using a celluloid strip and a metal strip was compared. Results. 80 % of all proximal contact was proper. Proper proximal contact was observed at the posterior area compared to the anterior area (P < .05). And male had proper proximal contact at the anterior area, female had proper proximal contact at the posterior area (P < .05). The consistency analysis between the results of the celluloid strip and the metal strip experiment on the results obtained from the floss using the consistency scale Kappa index shows that using celluloid strip is more advantageous than using the metal strip. Conclusion. Only 80% of all proximal contact was proper. Using celluloid strips with various thickness for evaluating of proximal contact is considered to be helpful for accurate measuring of proximal contact.

Digital contrast subtraction radiography for proximal caries diagnosis (인접면 치아우식 진단을 위한 디지털 방사선 조영 공제술)

  • Kang Byung-Cheol;Yoon Suk-Ja
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.123-127
    • /
    • 2002
  • Purpose : To determine whether subtraction images utilizing contrast media can improve the diagnostic performance of proximal caries diagnosis compared to conventional periapical radiographic images. Materials and Methods: Thirty-six teeth with 57 proximal surfaces were radiographied using a size #2 RVG-ui sensor (Trophy Radiology, Marne-la-Vallee, France). The teeth immersed in water-soluble contrast media and subtraction images were taken. Each tooth was then sectioned for histologic examination. The digital radiographic images and subtraction images were examined and interpreted by three dentists for proximal caries. The results of the proximal caries diagnosis were then verified with the results of the histologic examination. Results: The proximal caries sensitivity using digital subtraction radiography was significantly higher than simply examining a single digital radiograph. The sensitivity of the proximal dentinal carious lesion when analyzed with the subtraction radiograph and the radiograph together was higher than with the subtraction radiograph or the radiograph alone. Conclusion: The use of subtraction radiography with contrast media may be useful for detecting proximal dentinal carious lesions.

  • PDF

Partial Knee Joint Defect Reconstruction with Vascularized Proximal Fibular Articular Surface (슬관절 부분결손에 대한 혈관부착 비골근위 관절면을 이용한 재건술)

  • Chung, Duke-Whan
    • Archives of Reconstructive Microsurgery
    • /
    • v.7 no.2
    • /
    • pp.157-164
    • /
    • 1998
  • It has been very difficult to managing partial joint defect in any etiologies, especially in children. Unicondylar defect of the tibial condyle in children reconstructed with proximal fibular head with articular cartilage from 1995. Two kinds of transfering methods were used, peroneal artery pedicled ipsilateral fibula head transposition to defective lateral tibial condyle defect that revealed poor prognosis with gradual absorption of transposed fibular epiphysis. Free vascularized fibular head transplantation with microvascular anastomosis underwent in the case with medial condyle defect of tibia which revealed very satisfactory results. Author can conclude with these clinical experiences: 1. Tranposition without epiphyseal vesssels intact is not sufficient in fibular head osteochondral transplantation in reconstruction of tibial condyle defect. That means peroneal arterial vascular pedicle is not enough for transplanted proximal epiphysis maintains its function on articular surface and growth activity in children. 2. The anterior recurrent tibial artery is one of the most important and easy to utilizing vessel in proximal fibular epiphyseal transplantation. 3. Free vascularized fibular head transplantation is hopeful method in reconstruction of the knee joint in the patient with partial joint defect which has no effective solution in conventional methods.

  • PDF

Bioabsorbable Screws Used in Hallux Valgus Treatment Using Proximal Chevron Osteotomy (무지외반증 환자의 근위 갈매기형 절골술에서 생체 흡수성 나사못을 이용한 고정)

  • Shin, Woo-Jin;Chung, Young-Woo;An, Ki-Yong;Seo, Jae-Woong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.22 no.4
    • /
    • pp.181-183
    • /
    • 2018
  • Hallux valgus is a deformity that causes pain in the first metatarsophalangeal joint. Surgical methods are quite diverse and a range of osteotomies are used at the proximal and distal part of the metatarsal bone and proximal phalange. Fixation methods, such as plate, screw, K-wire, and others have been used in various ways. The fixation device is often removed with various side effects due to the fixation devices. In the case of instruments that are absorbed in vivo, these procedures are not necessary to remove and there is an advantage of not performing the second operation. Three patients were treated, in which a proximal chevron osteotomy was used with a bioabsorbable screw (K-$MET^{TM}$; U&I Corporation).

Detection of proximal caries using quantitative light-induced fluorescence-digital and laser fluorescence: a comparative study

  • Yoon, Hyung-In;Yoo, Min-Jeong;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.6
    • /
    • pp.432-438
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the in vitro validity of quantitative light-induced fluorescence-digital (QLF-D) and laser fluorescence (DIAGNOdent) for assessing proximal caries in extracted premolars, using digital radiography as reference method. MATERIALS AND METHODS. A total of 102 extracted premolars with similar lengths and shapes were used. A single operator conducted all the examinations using three different detection methods (bitewing radiography, QLF-D, and DIAGNOdent). The bitewing x-ray scale, QLF-D fluorescence loss (${\Delta}F$), and DIAGNOdent peak readings were compared and statistically analyzed. RESULTS. Each method showed an excellent reliability. The correlation coefficient between bitewing radiography and QLF-D, DIAGNOdent were -0.644 and 0.448, respectively, while the value between QLF-D and DIAGNOdent was -0.382. The kappa statistics for bitewing radiography and QLF-D had a higher diagnosis consensus than those for bitewing radiography and DIAGNOdent. The QLF-D was moderately to highly accurate (AUC = 0.753 - 0.908), while DIAGNOdent was moderately to less accurate (AUC = 0.622 - 0.784). All detection methods showed statistically significant correlation and high correlation between the bitewing radiography and QLF-D. CONCLUSION. QLF-D was found to be a valid and reliable alternative diagnostic method to digital bitewing radiography for in vitro detection of proximal caries.

Inter-rater agreement among shoulder surgeons on treatment options for proximal humeral fractures among shoulder surgeons

  • Kim, Hyojune;Song, Si-Jung;Jeon, In-Ho;Koh, Kyoung Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.1
    • /
    • pp.49-56
    • /
    • 2022
  • Background: The treatment approach for proximal humeral fractures is determined by various factors, including patient age, sex, dominant arm, fracture pattern, presence of osteoporosis, preexisting arthritis, rotator cuff status, and medical comorbidities. However, there is a lack of consensus in the literature regarding the optimal treatment for displaced proximal humeral fractures. This study aimed to assess and quantify the decision-making process for either conservative or surgical treatment and the choice of surgical method among shoulder surgeons when treating proximal humeral fractures. Methods: Forty sets of true anteroposterior view, scapular Y projection view, and three-dimensional computed tomography of proximal humeral fractures were provided to 12 shoulder surgeons along with clinical information. Surveys regarding Neer classification, decisions between conservative and surgical treatments, and chosen methods were conducted twice with an interval of 2 months. The factors affecting the treatment plans were also assessed. Results: The inter-rater agreement was fair for Neer classification (kappa=0.395), moderate for the decision between conservative and surgical treatments (kappa=0.528), and substantial for the chosen method of surgical treatment (kappa=0.740). The percentage of agreement was 71.1% for Neer classification, 84.6% for the decision between conservative and surgical treatment, and 96.4% for the chosen method of surgical treatment. The fracture pattern was the most crucial factor in deciding between conservative and surgical treatments, followed by age and physical activity. Conclusions: The decision between conservative and surgical treatment for proximal humeral fractures showed good agreement, while the chosen method between osteosynthesis and arthroplasty showed substantial agreement among shoulder surgeons.

The Development of the Shunt Guiding Kit for the Proper Positioning of the Proximal Shunt Catheter to the Lateral Ventricle in the Ventriculo-Peritoneal Shunt Operation (뇌실-복강간 단락술에서 Proximal Catheter의 정확한 측뇌실내로의 위치를 위한 Shunt Guiding Kit의 개발)

  • Shin, Yong Sam;kim, Se-Hyuk;Zhang, Ho Yeol;Bae, Ju Yong
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.8
    • /
    • pp.981-984
    • /
    • 2001
  • Object : To treat hydrocephalus by ventriculo-peritoneal shunt operation, the correct positioning of the proximal catheter in the ventricle is very important. The purpose of this study was to develop the "shunt guiding kit" for the proper positioning of the proximal shunt catheter to the ventricle in the ventriculo-peritoneal shunt operation. Materials and Methods: The "shunt guiding kit" is made of tungsten alloy and it consists of one frame, two screws and one guider. Through the guider, the proximal shunt catheter operates by mechanically coupling the posterior burr hole to the anterior target point. Results: We have treated three hydrocephalus patients with use of the "shunt guiding kit", and achieved good location of proximal shunt catheters. Conclusion: We developed the "shunt guiding kit" for the proper positioning of the proximal shunt catheter to the ventricle, and this would be very useful for preventing ventriculo-peritoneal shunt malfunction and preventing possible brain injury during the procedures.

  • PDF