• Title/Summary/Keyword: proximal caries

Search Result 73, Processing Time 0.022 seconds

The effects of noise reduction, sharpening, enhancement, and image magnification on diagnostic accuracy of a photostimulable phosphor system in the detection of non-cavitated approximal dental caries

  • Kajan, Zahra Dalili;Davalloo, Reza Tayefeh;Tavangar, Mayam;Valizade, Fatemeh
    • Imaging Science in Dentistry
    • /
    • v.45 no.2
    • /
    • pp.81-87
    • /
    • 2015
  • Purpose: Contrast, sharpness, enhancement, and density can be changed in digital systems. The important question is to what extent the changes in these variables affect the accuracy of caries detection. Materials and Methods: Forty eight extracted human posterior teeth with healthy or proximal caries surfaces were imaged using a photostimulable phosphor (PSP) sensor. All original images were processed using a six-step method: (1) applying "Sharpening 2" and "Noise Reduction" processing options to the original images; (2) applying the "Magnification 1:3" option to the image obtained in the first step; (3) enhancing the original images by using the "Diagonal/"option; (4) reviewing the changes brought about by the third step of image processing and then, applying "Magnification 1:3"; (5) applying "Sharpening UM" to the original images; and (6) analyzing the changes brought about by the fifth step of image processing, and finally, applying "Magnification 1:3." Three observers evaluated the images. The tooth sections were evaluated histologically as the gold standard. The diagnostic accuracy of the observers was compared using a chi-squared test. Results: The accuracy levels irrespective of the image processing method ranged from weak (18.8%) to intermediate (54.2%), but the highest accuracy was achieved at the sixth image processing step. The overall diagnostic accuracy level showed a statistically significant difference (p=0.0001). Conclusion: This study shows that the application of "Sharpening UM" along with the "Magnification 1:3" processing option improved the diagnostic accuracy and the observer agreement more effectively than the other processing procedures.

CLINICAL USE OF DENTAL RADIOGRAPHY IN THE DIAGNOSIS OF INTERPROXIMAL CARIES AND PERIODONTAL DISEASE (인접면 치아우식증과 치주질환의 진단에서 방사선 촬영의 이용)

  • Park Tae Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.17 no.1
    • /
    • pp.271-278
    • /
    • 1987
  • The purpose of the present study was to investigate associations between periapical and bitewing techniques by assessing the crestal alveolar bone. This article also reports the ability of these two techniques to correctly detect evidence of interproximal dental caries, and comparison between the interproximal overlapping of teeth. Bitewing and periapical radiographs were used from posterior quardants of 243 dental students in Seoul National University. The distance from cemento-enamel junction to the alveolar crest (CEJ-AC) was measured for each proximal surface from the distal of cuspid to the distal of second molar. Data were arranged according to the proximal surface examined, and bitewing and periapical measurements were compared using paired tests. The obtained results were as follows: 1. In maxilla, a significant t ratio with a P value of 0.05 or less reached for 100% and in mandible, reached for 94%. 2. The anatomic limitations imposed on periapical radiographic technique, most often result in somewhat foreshortened radiographic images. This situation would tend to be accentuated by the anatomical restrictions of the hard palate. 3. Consequently, since the significant differences frequently exist between measurements obtained from bitewing and periapical techniques, it is important to define which technique is used. 4. The number of the interproximal overlapping was the largest medial side of the maxillary second molar, while the smallest at the distal side of the mandibular second premolar. And the overall number of the interproximal overlapping was more (538) in the periapical technique than in the bitewing technique (372). 5. The interproximal dental carious lesions were detected more (74) on the bitewing films than on the periapical ones (23). The fact was resulted from the small number of interproximal overlapping and relative easi- ness of obtaining horizontal angulation in taking the bitewing radiographs.

  • PDF

A CLINICAL STUDY ON THE OCCURRENCE OF FOOD IMPACTION (식편압입의 발현에 관한 임상적 연구)

  • Jung, Jae-Hoon;Oh, Sang-Chun;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.1
    • /
    • pp.50-58
    • /
    • 2000
  • The purpose of this study was to investigate the causes of food impaction and to explore solutions as well. For this study, 39 patients with food impaction were selected. 77 contact areas in these patients were investigated mobility, tightness of contact area, gingival index, plaque index, attachment loss, alveolar bone loss, proximal caries, marginal ridge distance and occlusal relationships. The results were as follows ; 1. Teeth without distal support were found to be the most frequent site of food impaction (41.6%). Food impaction was found to be more frequent in the upper teeth (65.2%) than the lower teeth (33.8%). 2. Food impaction was found in tight contact cases (71.4%). Alveolar bone loss was not found in the early stage of food impaction (83.1%) 3. The distance between the marginal ridges of food impaction sites (mean=0.48mm) was short-er than that of the control group. (mean=0.77mm) (p<0.001) 4. In 18.2% of the cases, proximal carries were found at the food impaction site. 5. Food impaction affected patient's occlusion with the following frequencies, cusp to marginal ridge relationship (72.7%), cusp to fossa relationship (3.9%) and stepped relationship (23.4%).

  • PDF

Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries (CCD 디지털 방사선사진촬영법의 초기 치아우식증의 진단능 평가에 대한 연구)

  • Lee Wan;Lee Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.33 no.1
    • /
    • pp.27-33
    • /
    • 2003
  • Purpose : The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. Materials and Methods : 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOV A test. Results: The mean ROC areas of conventional radiography, indirect digital radiography, direct digital radiography, and digital subtraction radiography were 0.9093, 0.9102, 0.9184, and 0.9056, respectively. The diagnostic ability of direct digital radiography was better than the other imaging modalities, but there were no statistical differences among these imaging modalities (p > 0.05). Coclusion : These results indicate that new CCD-based digital systems (CDX-2000HQ) have the potential to serve as an alternative to conventional radiography in the detection of incipient dental caries.

  • PDF

EARLY DETECTION OF INITIAL DENTAL CARIES USING A $DIFOTI^{TM}$ (Digital Imaging Fiber-Optic Trans-illumination을 이용한 초기 법랑질 우식병소의 조기 진단)

  • Yeom, Hae-Woong;Yoo, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.587-597
    • /
    • 2004
  • Over the past 20 years, great strides have been made in research regarding the mechanisms involved in the progression of carious lesions, but new equipment and research tools need to be developed to continue these advancements in caries research. Various methods have been applied to reduce the incidence of carious lesions, which have led to a significant decrease in the number of occlusal caries, but a concurrent increase in the proportion of proximal carious lesions. New diagnostic equipment has been developed to detect early stage carious lesions, and these have demonstrated excellent laboratory results and show promise in clinical applications. The research presented here examines the efficacy of the newly developed $DIFOTI^{TM}$ system in detecting proximal carious lesions compared to traditional intraoral exam and bitewing radiography, possible problems or deficiencies of using the system in clinic, possible improvements that can be made to the system, and the efficacy of detecting early, reversible carious lesions that can be remineralized by preventative fluoride applications. The subject pool consisted of 23 grammer school age patients just prior to entering the mixed dentition phase. Each patient was given a thorough oral examination, radiographic examination consisting of bitewing radiographs of the posterior teeth, and $DIFOTI^{TM}$ examination of the anterior and posterior teeth. Each examination was carried out two times by two examiners, and the data were statistically analyzed. The results are as follows: 1. The mean alpha value of reliability test of the visual oral examination was as follows; occlusal surface was 0.8470. mesial surface was 0.6430, distal surface was 0.5727. lingual surface was 0.2807 and distal surface was 0.2339. When the examination was limited to posterior teeth, the mean alpha value was as follows; occlusal surface was 0.8577, distal surface was 0.8211, lingual surface was 0.7728, buccal surface was 0.7152 and mesial surface was 0.6782. 2. The alpha value of reliability test of the radiographic analysis of carious lesions of the occlusal, mesial, and distal surfaces was 0.8500. 3. The alpha value of reliability test of the $DIFOTI^{TM}$ diagnostic analysis of carious lesions of the occlusal, buccal, lingual, mesial, and distal surfaces was determined to be 0.7917. 4. The $DIFOTI^{TM}$ diagnostic system was found to be the most accurate means of detecting occlusal, buccal, and lingual surface carious lesions (p<0.05), while mesial and distal proximal carious lesions were most accurately assessed using bitewing radiography (p<0.05).

  • PDF

Optimum Image Compression Rate Maintaining Diagnostic Image Quality of Digital Intraoral Radiographs

  • Song Ju-Seop;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.30 no.4
    • /
    • pp.265-274
    • /
    • 2000
  • Purpose: The aims of the present study are to determine the optimum compression rate in terms of file size reduction and diagnostic quality of the images after compression and evaluate the transmission speed of original or each compressed image. Materials and Methods: The material consisted of 24 extracted human premolars and molars. The occlusal surfaces and proximal surfaces of the teeth had a clinical disease spectrum that ranged from sound to varying degrees of fissure discoloration and cavitation. The images from Digora system were exported in TIFF and the images from conventional intraoral film were scanned and digitalized in TIFF by Nikon SF-200 scanner (Nikon, Japan). And six compression factors were chosen and applied on the basis of the results from a pilot study. The total number of images to be assessed were 336. Three radiologists assessed the occlusal and proximal surfaces of the teeth with 5-rank scale. Finally diagnosed as either sound or carious lesion by one expert oral pathologist. And sensitivity, specificity and k value for diagnostic agreement was calculated. Also the area (Az) values under the ROC curve were calculated and paired t-test and oneway ANOVA test was performed. Thereafter, transmission time of the image files of the each compression level was compared with that of the original image files. Results: No significant difference was found between original and the corresponding images up to 7% (1 : 14) compression ratio for both the occlusal and proximal caries (p<0.05). JPEG3 (1 : 14) image files are transmitted fast more than 10 times, maintained diagnostic information in image, compared with original image files. Conclusion: 1 : 14 compressed image file may be used instead of the original image and reduce storage needs and transmission time.

  • PDF

LONG-TERM EVALUATING OF THE REMINERALIZATION OF INTERPROXIMAL CARIES ADJACENT TO GLASS IONOMER RESTORATIONS: A MICRO-CT STUDY (미세 전산화 단층 촬영을 이용한 글라스 아이오노머 수복물의 인접면우식 재광화 효과에 관한 장기간 연구)

  • Lee, Hyeok-Sang;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.498-503
    • /
    • 2006
  • This in vitro study compared the remineralization of incipient interproximal caries in the presence of three glass ionomer cements (highly-filled glass ionomer cement, compomer, resin-modified glass ionomer cement) and a resin composite(control). The long-term changes in remineralization caused by each material were evaluated by microtomography. Proximal restoration was simulated by placing tooth specimens and the various glass ionomer cements in closed containers with artificial saliva at $37^{\circ}C$ and pH 7.0 for 30 days with constant circulation Tomographic images were obtained with a micro CT scanner at 90, 180, and 270 days, and density-measuring software was used to calculate the micro-density of artificial caries lesions in the specimens. The mean density changes were compared between groups in order to evaluate the effects of remineralization. All data were analyzed using one-way ANOVA and the post-HOC Tukey multiple comparison test at p<0.05. While the density of artificial caries lesions increased for all treatments, the increases for the three glass ionomer groups were significantly higher than that for the resin group in each three month period. As time went on, the amount of density increase of the glass ionomer groups decreased, and significant differences were found between the remineralization effects of the glass ionomer groups.

  • PDF

Comparative Evaluation of the Survival Rates of Zirconia Crown and Stainless Steel Crown for Proximal Caries in Primary Molars: a Retrospective Study (유구치 인접면 우식증 수복 시 지르코니아 전장관과 기성금속관의 생존율 비교 평가: 후향적 연구)

  • Gahui Jeong;Nanyoung Lee;Hyewon Shin;Suhyun Park;Myeongkwan Jih
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.3
    • /
    • pp.307-317
    • /
    • 2023
  • Due to increasing demand for aesthetics, zirconia crowns have become a popular choice for treating primary molars. However, there is limited literature available comparing the survival rates of zirconia crowns with those of other restorative materials. The objective of this study was to compare the 36-month survival rates of zirconia crowns and stainless steel crowns for proximal caries, as well as to analyze failure types associated with each crown type. Electronic medical records and radiographs of 1,061 primary molars from 498 patients treated with 2 types of prefabricated crowns at Chosun University Dental Hospital and 2 private dental clinics between 2017 and 2019 were collected and analyzed. The survival rate of zirconia crowns was found to be lower compared to that of stainless steel crowns. Regarding the groups without pulp treatment, the survival rate of stainless steel crowns was significantly higher than that of zirconia crowns. However, in the groups that received pulp therapy, no significant difference in the survival rates was observed between the two preformed crowns. Notably, abnormal root resorption or periapical lesions were identified as the primary cause of restorative failure in stainless steel crowns, whereas loss of restoration was the predominant cause in zirconia crowns. This study holds valuable implications for clinicians when selecting preformed crowns for primary molars.

A Study on the Enamel Surface Texture and Caries Susceptibility in Interdentally Stripped Teeth (치간삭제 후의 법랑질 표면조도와 치아우식 감수성에 관한 연구)

  • Kim, Kyong-Nim;Yoon, Young-Ju;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.31 no.6 s.89
    • /
    • pp.567-578
    • /
    • 2001
  • To investigate the difference of Texture exhibited on interproximal enamel surface with each different stripping method and the susceptibility of proximal enamel to demineralization after stripping and the application of a topical fluoride go] and sealant, one hundred human premolars, which were Previously extracted for orthodontic reasons were evaluated by means of Scanning electron microscopy and laser fluorescence. The results were as follows : 1. No matter what the initial stripping instrument was the furrows that resulted from all the stripping methods were not completely removed by careful polishing. 2. Among the enamel surfaces that were treated with three different initial abrasive instruments, followed by the same polishing method (Sof-$Lex^{(r)}$ disks), the enamel surfaces that were treated with 700 crosscut carbide bur showed the smoothest surfaces. 3. The stripped teeth, no matter what the initial stripping instrument was, were less resistant to initial demineralization than untreated teeth. But no difference in caries susceptibility according to differently stripped methods was found (p<(0.001). 4. Teeth treated with APF-gel or sealant were mote resistant to demineralization than those treated without other treatment after stripping (p<0.001). 5. Comparing groups treated with APF-gel to groups treated with sealant, the former was more resistant to demineralization than the tatter (p<0.05). In conclusion, enamel surfaces that were stripped jnterproximally were less resistant to demineralization even though various attempts were made to produce smooth, self-cleaning enamel surfaces. Therefore, additional treatment-sealant or calcifying/ fluoridating solution To the stripped enamel surfaces is recommended.

  • PDF

Esthetic Restoration Using Targis & Vectris System (TARGIS & VECTRIS SYSTEM을 이용한 심미적 수복)

  • Choi, H.S.;Hwang, J.W.;Shin, S.W.;Suh, K.W.
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.7 no.1
    • /
    • pp.18-26
    • /
    • 1998
  • The improvement of esthetic dentistry has been accelerated from the development of composite resin and dentin-enamel adhesive since 1980's. The indirect composite resin restorations have more accurate proximal contact point and occlusal form than direct restoration. And the side effect of resin shrinkage is minimal because the amount of composite used in oral cavity is limited in cement space. As a results, marginal leakage, hypersensitivity, secondary caries, and discoloration are significantly diminished. The first generation laboratory composite resin used in indirect resin restoration had been widespread in 1980's and the second generation laboratory composite resins were developed in 1990's. The second generation laboratory composite resins are called Ceramic Polymer. The physical properties of Ceramic Polymer are improved because of high content of inorganic filler, and the esthetics and biocompatibility are better than that of the first generation resin. So the application range using composite resin have been broadened. The purpose of this paper is to introduce Targis & Vectris system that is classified to second generation laboratory composite and to report several cases in which the system was utilized for restoration.

  • PDF