• 제목/요약/키워드: prototype loading test

검색결과 49건 처리시간 0.027초

터널 건전도 평가를 위한 라이닝 모델실험 (Model Test of Lining for Estimation of Tunnel Soundness)

  • 김영근
    • 자연, 터널 그리고 지하공간
    • /
    • 제1권2호
    • /
    • pp.59-71
    • /
    • 1999
  • Recently, many deformations in tunnel such as crack and leakage were occulted. Specially, the defects of tunnel lining have been a serious problem in safety and stability many repair works for maintenance in tunnel have been carried out. Therefore, it is necessary to estimate the structural cracking for countermeasure in deformed tunnel and to investigate on the characteristics of lining system and the soundness of tunnel. In this study model tests for tunnel lining were carried out using test apparatus and centrifuge, In the direct loading test, the prototype was Kyungbu high-speed railway tunnel and the scale is 1/10, and lining models were made of concrete. Test conditions included load conditions such as direction, shape and type, lining conditions such as single and double lining, thickness, and reinforcement. In centrifuge model test, the prototype was Seoul subway tunnel and the scale is 1/100, and lining models were made of aluminum and hydrostone. Test conditions included tunnel defects such as thickness shortage. behind cavity and longitudinal cracks, reinforcement methods such as epoxy, grouting and carbon sheet. From these model tests , the characteristics of deformation and failure for tunnel lining were estimated, and the structural behaviors of deformed lining and the effects of repair and reinforcement for tunnel lining were researched.

  • PDF

댐 안전성 평가를 위한 여수로 피어부의 정적 거동 분석 (Static Behavior Analysis of Spillway Pier for Dam Safety Evaluation)

  • 장봉석;임정열;이명규;이형준
    • 콘크리트학회논문집
    • /
    • 제19권1호
    • /
    • pp.11-18
    • /
    • 2007
  • 댐 안전성 평가를 위한 내진성능평가는 지속적으로 실시하였으나, 댐에서 취약부로 알려진 여수로 피어부에 대한 거동 분석에 대한 연구는 거의 이루어지지 않았다. 실제 지진발생시 여수로 피어가 국부 손상을 받기에 취약한 부분으로 추정되어 본 연구에서 댐의 내진성능 평가를 위한 기초 실험으로서 정적 시험을 수행하였다. 본 연구에서는 댐의 여수로 피어부에 대한 축소된 철근콘크리트 모형을 통한 강도모델을 구성하여 정적 모형 시험을 실시하고, 시험 결과의 분석, 구조해석을 통한 실제 구조물의 거동 및 균열하중, 극한하중에 대한 분석을 실시하였다. 대상 시험체에 대한 모형 시험 결과와 수치해석 결과는 서로 다른 파괴 거동을 나타내어 파괴하중이 서로 다르게 추정되었으나, 모형 시험체의 파괴 거동을 고려하는 경우에는 정적 시험과 해석을 통하여 실제 구조물의 균열 발생 하중과 극한하중을 추정할 수 있는 것으로 사료된다.

상사법칙이 적용된 철근콘크리트 기둥 축소모형의 지진 취약도 분석 (Fragility Analysis of A Scaled Model of Reinforced Concrete Column in Accordance with Similitude Law)

  • 박동욱;전법규;김남식;박자민;조재열
    • 한국지진공학회논문집
    • /
    • 제21권2호
    • /
    • pp.87-93
    • /
    • 2017
  • Many studies are conducted in several fields for fragility analysis of structures or elements which is a probabilistic seismic safety analysis in consideration with uncertainty of seismic loading. It is hard to directly conduct fragility analysis for an infrastructure with social importance due to its size. Therefore, a fragility analysis for an infrastructure mainly conducted in element level or conducted with scaled model built in accordance with similarity law. In this article, fragility analysis for prototype and scaled model of reinforced concrete column was conducted with numerical models which had been updated by the results of shaking table test and pseudo dynamic test. As a result, response stress from the numerical analysis result of prototype model was higher than that from scaled model due to different stiffness ratios between steel and concrete. However, the probability of failure for scaled model was higher than that for prototype model because failure criteria for scaled model was down due to similarity law. Also it was evaluated that probability of failure by using log normal standard deviation of response stresses by spectrum matched accelerograms was more reliable than probability of failure by using existing coefficient of variation normally used.

실내 진동대 실험을 통한 하구둑 구조물의 내진 안정성에 관한 연구 (A Study on Stability of Earthquake in Estuary Barrage through Shaking Table Test)

  • 신은철;강현회;류병현
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회 2차
    • /
    • pp.38-44
    • /
    • 2010
  • Shaking table tests were performed to reproduce the dynamic behavior of estuary barrage and its subbase soil which can be potentially damaged during earthquake loading. For understanding the vibration effect to the ground during earthquake, the model was formulated with 1/300 scale of prototype estuary barrage and subbase soil. Scott and Iai(1989) proposed the law of the similarity for similar experimental conditions. The laboratory model shaking table test was conducted under the vibration condition of simulated earthquake of 0.154g. The horizontal displacement on the structure was measured during the shaking table test. The pore water pressure was also monitored for the underground layers of soil. The field horizontal displacement and the pore water pressure can be predicted by using the results of the laboratory shaking table test.

  • PDF

2층 RC 전단벽식 구조물의 내진성능에 대한 정적 실험 (Static Experiment for the Seismic Performance of a 2 Story RC Shear Wall System)

  • 이상호;오상훈;황원태;이경보;이한선
    • 한국지진공학회논문집
    • /
    • 제14권6호
    • /
    • pp.55-65
    • /
    • 2010
  • 본 실험 연구의 목적은 횡방향 정적가력을 통하여 2층 R.C 전단벽식 구조의 내진성능을 평가하는 것이다. 본 연구의 실험체는 대상 건물의 개구부를 가지는 T자형 벽체 1층과 2층의 일부분을 대상으로 실물크기의 3/5 크기정도로 축소하였고, 인방보의 유 무를 실험변수로한 2개의 실험체를 제작하여 횡방향의 정적가력 실험을 수행하였다. 인방보 유무에 따른 벽체의 구조적 성능 및 거동의 차이를 비교한 결과, 인방보가 있는 실험체가 인방보가 없는 실험체보다 최대내력과 연성능력 등의 내진성능이 우수한 것으로 판단되었다.

수평 반복하중을 받는 비내진상세 RC 중실원형교각의 거동특성 (Behavior of Solid Circular RC Piers without Seismic Detailing Subjected to Cyclic Lateral Load)

  • 김재관;김익현;임현우;전귀현
    • 한국지진공학회논문집
    • /
    • 제5권4호
    • /
    • pp.83-95
    • /
    • 2001
  • 내진상세가 적용되지 않은 철근콘크리트 교각의 거동특성 및 내진성능을 살펴보기 위해서 축소교각모형실험을 수행하였다. 횡방향 철근이 심부를 구속할 만큼 충분히 배근되어 있지 않은 중심 원형 단면의 실교각을 대상으로 기초 상단의 소성 힌지 부위에서 겹침이음이 된 주철근을 사용했을 때와 연속철근을 사용했을 경우로 구분되도록 철근상세를 결정하였다. 이에 따라 3기의 축소교각시험체를 제작하여 수직방향 축하중을 가한 상태에서 준정적 반복하중을 재하하는 실험을 수행하였다. 실험결과를 통해서 겹침이음이 있는 교각시험체는 연성거동을 하지 않지만, 겹침이음이 없이 연속철근을 사용한 교각시험체는 어느 정도의 한정연성거동을 하는 것으로 분석되었다.

  • PDF

철근콘크리트 구조물에 대한 반복하중속도의 영향에 관한 연구 (Effects of Cyclic Loading Rate on response of Reinforced Concrete Structures)

  • 정란;박현수
    • 전산구조공학
    • /
    • 제2권3호
    • /
    • pp.77-84
    • /
    • 1989
  • 본 논문의 내용은 철근콘크리트 보-기둥 접합부가 지진 하중을 받을 때의 거동에 대하여 관찰한 것이다. 똑같이 제작된 두개의 시험체에 정적 반복하중과 동적 반복하중을 가하여 하중-처짐 곡선이나 파괴 성상 등에 관하여 차이점을 기록하였다. 동적하중을 받는 시험체의 거동은 내진설계 규준에서 일반적으로 쓰여지는 정적하중 하에서의 시험체의 거동과는 판이한 양상을 보여주었다. 시험체가 동적하중을 받을 때에는 정적하중을 받을 때 보다 1. 극한하중이 20-25% 증가하고 2. 높은 취성을 보이며 3. 균열이 집중되고 4. 휨파괴 보다는 전단파괴현상을 나타내었다.

  • PDF

Loading rate effect on superelastic SMA-based seismic response modification devices

  • Zhu, Songye;Zhang, Yunfeng
    • Earthquakes and Structures
    • /
    • 제4권6호
    • /
    • pp.607-627
    • /
    • 2013
  • The application of shape memory alloys (SMAs) to the seismic response reduction of civil engineering structures has attracted growing interest due to their self-centering feature and excellent fatigue performance. The loading rate dependence of SMAs raises a concern in the seismic analysis of SMA-based devices. However, the implementation of micromechanics-based strain-rate-dependent constitutive models in structural analysis software is rather complicated and computationally demanding. This paper investigates the feasibility of replacing complex rate-dependent models with rate-independent constitutive models for superelastic SMA elements in seismic time-history analysis. Three uniaxial constitutive models for superelastic SMAs, including one rate-dependent thermomechanical model and two rate-independent phenomenological models, are considered in this comparative study. The pros and cons of the three nonlinear constitutive models are also discussed. A parametric study of single-degree-of-freedom systems with different initial periods and strength reduction factors is conducted to examine the effect of the three constitutive models on seismic simulations. Additionally, nonlinear time-history analyses of a three-story prototype steel frame building with special SMA-based damping braces are performed. Two suites of seismic records that correspond to frequent and design basis earthquakes are used as base excitations in the seismic analyses of steel-braced frames. The results of this study show that the rate-independent constitutive models, with their parameters properly tuned to dynamic test data, are able to predict the seismic responses of structures with SMA-based seismic response modification devices.

Safety assessment of nuclear fuel reprocessing plant under the free drop impact of spent fuel cask and fuel assembly part I: Large-scale model test and finite element model validation

  • Li, Z.C.;Yang, Y.H.;Dong, Z.F.;Huang, T.;Wu, H.
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2682-2695
    • /
    • 2021
  • This paper aims to evaluate the structural dynamic responses and damage/failure of the nuclear fuel reprocessing plant under the free drop impact of spent fuel cask (SFC) and fuel assembly (FA) during the on-site transportation. At the present Part I of this paper, the large-scale SFC model free drop test and the corresponding numerical simulations are performed. Firstly, a composite target which is composed of the protective structure, i.e., a thin RC plate (representing the inverted U-shaped slab in the loading shaft) and/or an autoclaved aerated concrete (AAC) blocks sacrificial layer, as well as a thick RC plate (representing the bottom slab in the loading shaft) is designed and fabricated. Then, based on the large dropping tower, the free drop test of large-scale SFC model with the mass of 3 t is carried out from the height of 7 m-11 m. It indicates that the bottom slab in the loading shaft could not resist the free drop impact of SFC. The composite protective structure can effectively reduce the damage and vibrations of the bottom slab, and the inverted U-shaped slab could relieve the damage of the AAC blocks layer dramatically. Furthermore, based on the finite element (FE) program LS-DYNA, the corresponding refined numerical simulations are performed. By comparing the experimental and numerical damage and vibration accelerations of the composite structures, the present adopted numerical algorithms, constitutive models and parameters are validated, which will be applied in the further assessment of drop impact effects of full-scale SFC and FA on prototype nuclear fuel reprocessing plant in the next Part II of this paper.

말뚝 기초 고유진동수의 가속도 크기 의존성을 고려한 상사법칙 개발 (Development of the similitude law considering the intensity-dependent variation of natural frequency of pile foundation system)

  • 최정인;유민택;김성렬;김명모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.905-912
    • /
    • 2009
  • 1-g shaking table test is conducted to evaluate the dynamic behavior of a soil-structure system under seismic loading condition. A consistent similitude law between the model and prototype is needed to predict the behavior of the prototype structure, quantitatively. The natural frequency of geomaterial decreases with the increase of shaking intensity because of the non-linear property of the geomaterial. This phenomenon affects the applicability of similitude laws in 1-g shaking table tests. In this study, a simple method is suggested to determine the frequency of the input motions in 1-g tests in order to enhance the applicability of similitude laws. Modified input frequency is calculated using the frequency ratio with consideration of the variation of the natural frequency according to the intensity of input ground acceleration. To verify the applicability of the suggested method, a series of 1-g shaking table tests were performed for three different sizes of model piles having an overburden mass on their heads by varying the acceleration and the frequency of input motion. The acceleration amplification ratio on the overburden mass, the lateral displacement at the pile head and the maximum bending moment along the pile depth were measured. The projected behaviors of the virtual prototype based on the measured values of the model tests, where the input frequencies were calculated by the new method, showed good consistency, verifying the applicability of the suggested method.

  • PDF