• Title/Summary/Keyword: protocol testing

Search Result 251, Processing Time 0.023 seconds

Image Quality and Dose Assessment According to Examination Mode during Head CT Examination (두부 CT 검사 시 검사 모드에 따른 화질 및 선량평가)

  • Gang, Heon-Hyo;Choi, Woo-Jeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.437-444
    • /
    • 2021
  • To evaluate the usefulness of Volume Axial Mode by comparing analyzing the exposure dose of the patients and the quality of each images from CT images obtained from high pitch mode using the local phantom or volume axial mode to determine the usefulness of he volume axial mode in diagnosing the head and cervical disease in adults. High Pitch Mode, Helical Mode, and Volume axial Mode as adult phantom were tested according to 70 kVp, 80 kVp, and 100 kVp tube voltages during an adult frontal CT scans. The equipment used was GE's Revolution (GE Healthcare, Wisconsin USA) model and iMED X-ray Phantom. The exposure dose of phantom was compared using the images obtained from each protocol, and the image quality was compared by calculating SNR and CNR by setting ROI on each image. When examined using Volume Axial Mode, the exposure dose of phantom was measured 17.12% lower than Helical Mode, 5.35% lower than High Pitch Mode, and both SNR and CNR were improved. Volume Axial Mode is a useful test that reduces investigation time without table movement using high speed rotary scanner, and in which exposure dose is reduced and image quality is improved by acquiring images in a short time of 0.28 seconds of phantom than using High Pitch Mode and Helical Mode. In addition, the fast testing time of Volume Axial Mode can be seen as the biggest advantage CT scans of emergency patients or patients with physical discomfort.

A Review of the Stroke Stage and Outcome Measures in Stroke Motor Sequelae Clinical Studies in Korea (뇌졸중으로 인한 운동 관련 후유증의 한의 치료 연구에서 뇌졸중 시기 및 평가 척도에 대한 국내 문헌 고찰)

  • Lee, Ji-eun;Chun, Se-eun;Jeon, Min-gyeol;Shin, Yong-jeen;Leem, Jung-tae;Shin, Sun-ho
    • The Journal of Internal Korean Medicine
    • /
    • v.43 no.4
    • /
    • pp.656-679
    • /
    • 2022
  • Objectives: The aims of this study were to evaluate the fidelity of stroke stage reporting, the timeliness of the outcome measures, and the use of the core outcome set. Methods: We searched the literature using 6 domestic databases. We selected studies that used Korean medicine interventions and targeted stroke patients with motor sequelae. We examined whether the included studies reported the stroke stage and whether they used the outcome measures in the appropriate period based on the recommendations of the "Stroke Evidence Database to Guide Effectiveness". We also confirmed the use of the essential assessment tools suggested by the core outcome set. Results: Overall, 77 studies were finally selected, with 16 (21%), 55 (71%), and 6 (8%) published on the acute, subacute, and chronic phases, respectively. Only 11 of the studies directly mentioned the stroke stage. The most commonly used assessments were the National Institutes of Health Stroke Scale, Modified Barthel Index, and Manual Muscle Testing. Only 5 studies failed to apply the stage-related outcome measures at the recommended period. The outcome variables used inadequately were the National Institutes of Health Stroke Scale, Functional Ambulation Categories, 36-Item Short Form Health Survey, and Mini-Mental State Examination. Among the core outcome set items, some studies used liver and renal function tests, but no herbal medicine safety reporting was conducted. Conclusions: In future studies, we propose to ensure accurate reporting of the stroke stage with reliable outcome measures to deliver better clinical and research outcomes. Furthermore, in future clinical studies on stroke, a standard protocol that reflects the core outcome set should be developed.

A Study of Performance Analysis on Effective Multiple Buffering and Packetizing Method of Multimedia Data for User-Demand Oriented RTSP Based Transmissions Between the PoC Box and a Terminal (PoC Box 단말의 RTSP 운용을 위한 사용자 요구 중심의 효율적인 다중 수신 버퍼링 기법 및 패킷화 방법에 대한 성능 분석에 관한 연구)

  • Bang, Ji-Woong;Kim, Dae-Won
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.1
    • /
    • pp.54-75
    • /
    • 2011
  • PoC(Push-to-talk Over Cellular) is an integrated technology of group voice calls, video calls and internet based multimedia services. If a PoC user can not participate in the PoC session for various reasons such as an emergency situation, lack of battery capacity, then the user can use the PoC Box which has a similar functionality to the MM Box in the MMS(Multimedia Messaging Service). The RTSP(Real-Time Streaming Protocol) method is recommended to be used when there is a transmission session between the PoC box and a terminal. Since the existing VOD service uses a wired network, the packet size of RTSP-based VOD service is huge, however, the PoC service has wireless communication environments which have general characteristics to be used in RTSP method. Packet loss in a wired communication environments is relatively less than that in wireless communication environment, therefore, a buffering latency occurs in PoC service due to a play-out delay which means an asynchronous play of audio & video contents. Those problems make a user to be difficult to find the information they want when the media contents are played-out. In this paper, the following techniques and methods were proposed and their performance and superiority were verified through testing: cross-over dual reception buffering technique, advance partition multi-reception buffering technique, and on-demand multi-reception buffering technique, which are designed for effective picking up of information in media content being transmitted in short amount of time using RTSP when a user searches for media, as well as for reduction in playback delay; and same-priority packetization transmission method and priority-based packetization transmission method, which are media data packetization methods for transmission. From the simulation of functional evaluation, we could find that the proposed multiple receiving buffering and packetizing methods are superior, with respect to the media retrieval inclination, to the existing single receiving buffering method by 6-9 points from the viewpoint of effectiveness and excellence. Among them, especially, on-demand multiple receiving buffering technology with same-priority packetization transmission method is able to manage the media search inclination promptly to the requests of users by showing superiority of 3-24 points above compared to other combination methods. In addition, users could find the information they want much quickly since large amount of informations are received in a focused media retrieval period within a short time.

The Effect of Temporary Cement Cleaning Methods on the Retentive Strength of Cementation Type Implant Prostheses (임시 시멘트 제거방법이 시멘트 유지형 임플란트 보철물의 유지력에 미치는 영향)

  • Shin, Hwang-Kyu;Song, Young-Gyun;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.125-140
    • /
    • 2011
  • The remnant of temporary cement on the intaglio surface of cast restoration may have a negative effect on the retentive strength of permanent cement. This study was to evaluate the effect of temporary cement cleaning methods on the retentive strength of cementation type implant prostheses. Prefabricated implant abutments - height 5.5mm, diameter 4.5mm, 6 degree axial wall taper with chamfer margins were used. Forty copings-abutment specimens were divided into four groups(each n=10) according to the cleaning methods for temporary cement(Temp-$Bond^{(R)}$) as follows : no temporary cementation(the control group), orange solvent, ultrasonic cleaning, air borne-particle abrasion. After the application of temporary cement and the separation, the cleaning procedure was performed according to the protocol of each group. The specimens were cemented with $Premier^{(R)}$ Implant $Cement^{TM}$. After the permanent cementation, the specimens were subjected to thermocycling and pulled out from the specimens with a universal testing machine at a cross-head speed of 0.5mm/min. After the retentive strength test, all the specimens were cleaned using ultrasonic cleaning, abraded with air borne-particles, and steam-cleaned. Likewise, the specimens were temporarily cemented(Temp-$Bond^{(R)}$ NE), cleaned according to the protocol of each group, cemented with $Premier^{(R)}$ Implant $Cement^{TM}$ and subjected to thermocycling and measurement of their retentive strength. The mean of group with orange solvent were significantly lower than those of other groups(p<0.05). There was no significance between group with ultrasonic cleaning and group with air borne-particle abrasion. Group with ultrasonic cleaning and group with air-particle abrasion were no significance at control group. There was no significance between group cemented with Temp-$Bond^{(R)}$ and group cemented with Temp-$Bond^{(R)}$ NE. Within the limitation of this study, it can be concluded that the temporary cement cleaning method with only orange solvent may have a negative effect on the retentive strength of permanent cement. Ultrasonic cleaning and air borne-particle abrasion methods are recommended for the temporary cement cleaning method on cementation type implant prostheses.

Effects of specimens dimension on the flexural properties and testing reliability of dental composite resin (치과용 복합레진의 굽힘 특성과 시험 신뢰도에 미치는 시편 크기의 영향)

  • Im, Yong-Woon;Hwang, Seong-sig;Kim, Sa-hak;Lee, Hae-Hyoung
    • Korean Journal of Dental Materials
    • /
    • v.44 no.3
    • /
    • pp.273-280
    • /
    • 2017
  • The aim of the present study was to investigate the effects of specimen dimension on the flexural properties and testing reliability of dental composite resin. The composite resin was prepared experimentally by mixing a resin matrix with silanated micrometer glass filler at 50 vol%. Flexural specimens with various dimension in specimen's width were fabricated by light curing using a split metal mold; $25{\times}2{\times}2mm$, $25{\times}2{\times}4mm$, $25{\times}2{\times}6mm$ in length ${\times}$ height ${\times}$ width. The flexural strength and modulus were determined according to ISO 4049 test protocol at a span length of 20 mm (normal-flexural strength; NFS). Another flexural test was conducted using mini-sized specimens ($12{\times}2{\times}2mm$, $12{\times}2{\times}4mm$, $12{\times}2{\times}6mm$) from the broken specimens at a span length of 10 mm (mini-flexural strength; MFS). Data were analyzed with ANOVA and Duncan's post-hoc test and the test reliability was evaluated by Weibull analysis. Results showed that there are generally no significant difference in flexural strength with the increase in the specimen width in NFS and MFS tests. However, the test reliability of flexural strength based on Weibull analysis was largely changed with the variables in the dimension of width and span length. The flexural modulus of NFS was increased as the dimension of specimens width increased while there was no trend in flexural modulus of MFS test. Overall results recommend that the evaluation of flexural properties and the reliability of dental composite resins should be performed with more than one test method.

Predicting Oxygen Uptake for Men with Moderate to Severe Chronic Obstructive Pulmonary Disease (COPD환자에서 6분 보행검사를 이용한 최대산소섭취량 예측)

  • Kim, Changhwan;Park, Yong Bum;Mo, Eun Kyung;Choi, Eun Hee;Nam, Hee Seung;Lee, Sung-Soon;Yoo, Young Won;Yang, Yun Jun;Moon, Joung Wha;Kim, Dong Soon;Lee, Hyang Yi;Jin, Young-Soo;Lee, Hye Young;Chun, Eun Mi
    • Tuberculosis and Respiratory Diseases
    • /
    • v.64 no.6
    • /
    • pp.433-438
    • /
    • 2008
  • Background: Measurement of the maximum oxygen uptake in patients with chronic obstructive pulmonary disease (COPD) has been used to determine the intensity of exercise and to estimate the patient's response to treatment during pulmonary rehabilitation. However, cardiopulmonary exercise testing is not widely available in Korea. The 6-minute walk test (6MWT) is a simple method of measuring the exercise capacity of a patient. It also provides high reliability data and it reflects the fluctuation in one' s exercise capacity relatively well with using the standardized protocol. The prime objective of the present study is to develop a regression equation for estimating the peak oxygen uptake ($VO_2$) for men with moderate to very severe COPD from the results of a 6MWT. Methods: A total of 33 male patients with moderate to very severe COPD agreed to participate in this study. Pulmonary function testing, cardiopulmonary exercise testing and a 6MWT were performed on their first visits. The index of work ($6M_{work}$, 6-minute walk distance [6MWD]${\times}$body weight) was calculated for each patient. Those variables that were closely related to the peak $VO_2$ were identified through correlation analysis. With including such variables, the equation to predict the peak $VO_2$ was generated by the multiple linear regression method. Results: The peak $VO_2$ averaged $1,015{\pm}392ml/min$, and the mean 6MWD was $516{\pm}195$ meters. The $6M_{work}$ (r=.597) was better correlated to the peak $VO_2$ than the 6MWD (r=.415). The other variables highly correlated with the peak $VO_2$ were the $FEV_1$ (r=.742), DLco (r=.734) and FVC (r=.679). The derived prediction equation was $VO_2$ (ml/min)=($274.306{\times}FEV_1$)+($36.242{\times}DLco$)+($0.007{\times}6M_{work}$)-84.867. Conclusion: Under the circumstances when measurement of the peak $VO_2$ is not possible, we consider the 6MWT to be a simple alternative to measuring the peak $VO_2$. Of course, it is necessary to perform a trial on much larger scale to validate our prediction equation.

A Study on the Acceptance of Convergence System of Broadcasting, and Telecommunication, and Their Relative Efficiency Focusing on IPFV (방송과 통신 융합시스템의 수용 및 상대적 효능에 관한 연구: IPTV를 중심으로)

  • Um, Myoung-Yong;Lee, Sang-Ho;Kim, Jai-Beam
    • Asia pacific journal of information systems
    • /
    • v.19 no.3
    • /
    • pp.25-49
    • /
    • 2009
  • Advances in technology have resulted in the emergence of new information systems. The convergence of IT and manufacturing sectors has blurred the boundaries among industries. Also, such convergence has become established as a paradigm to build a new area. Especially the convergence of broadcasting and telecommunication, notably in the case of IPTV (Internet Protocol Television), is among the most salient examples of its kind in recent years as a major case of disruptive technology innovation. Despite its much fanfare, such convergence, however, has not fulfilled the expectation; it has not produced positive economic effects while negatively affecting the growth of IPIV. Stakeholders in and around IPIV including telecommunication companies, broadcasting corporations, and government bodies wish to gain control of IPTV under their wings. IPTV has drifted in the midst of conflicts among the stakeholders in and around IPTV, particularly telecommunication and broadcasting organizations in a broad sense. Our empirical research intends to deal with how audiences accept IPTV and how firms provide IPTV services to utilize their resources. Three research questions in this paper include, first, whether Technology Acceptance Model (TAM) can sufficiently explain the acceptance of IPTV as an information system. The second question concerns with empirically testing the playful aspect of IPTV to increase its audience acceptance. Last, but not least, this paper deals with how firms can efficiently and effectively allocate their limited resources to increase IPTV viewers. To answer those three main questions of our study, we collect data from 197 current subscribers of high speed internet service and/or cable/satellite television. Empirical results show that 'perceived usefulness (PU) $\rightarrow$ Intention to use' and 'perceived ease of use (PEU) $\rightarrow$ Intention to use' are significant. Also, 'perceived ease of use' is significantly related to 'perceived usefulness.' Perceived ease of handling IPTV without much effort can positively influence the perceived value of IPTV. In this regard, engineers and designers of IPTV should pay more attention to the user-friendly interface of IPTV. In addition, 'perceived playfulness (PP)' of IPTV is positively related to 'intention to use'. Flow, fun and entertainment have recently gained greater attention in the research concerned with information systems. Such attention is due to the changing features of information systems in recent years that combine the functional and leisure attributes. These results give practical implications to the design of IPTV that reflects not just leisure but also functional elements. This paper also investigates the relationship between 'perceived ease of use (PEU)' and 'perceived playfulness (PP).' PEU is positively related to pp. Audiences without fear can be attracted more easily to the user-friendly IPTV, thereby perceiving the fun and entertainment with ease. Practical implications from this finding are that, to attract more interest and involvement from the audience, IPTV needs to be designed with similar or even more user friendly interface. Of the factors related to 'intention to use', 'perceived usefulness (PU)' and 'perceived ease of use (PEU)' have greater impacts than 'perceived playfulness (PP).' Between PU and PEU, their impacts on 'intention to use' are not significantly different statistically. Managerial implications of this finding are that firms in preparation for the launch of IPTV service should prioritize the functions and interface of IPTV. This empirical paper also provides further insight into the ways in which firms can strategically allocate their limited resources so as to appeal to viewers, both current and potential, of IPTV.

Current Status and Perspective and Future Task in Korea of Crop Genetic Transformation (작물형질전환의 현황과 한국내의 발전전망 및 과제)

  • Harn, Chee-Hark
    • Journal of Plant Biotechnology
    • /
    • v.33 no.3
    • /
    • pp.171-184
    • /
    • 2006
  • According to ISAAA report, the global area of genetically modified (GM) crops increased more than 50 fold during the ten-year period from 1996 to 2005 with a sustained double-digit growth rate of 10%. This biotechnology adoption is one of the highest rates of technology adoption in agriculture history and this phenomenon indicates that the industrial value of the GM crops is highly perspective. In addition, the year 2010, 60% of cereal seeds in the global market would be GM or biotechnology related seeds so that the GM crop regards as the second green revolution that could provide a huge impact to food and agriculture. Nevertheless, there has not been any GM variety ever successfully commercialized in Korea and even none of the GM crops has ever been approved for safety testing by risk assessment. This seems that Korean agriculture industry might be indeed lost in the war of future seed market. However, lots of evidence show that Korean scientists have established advanced technologies and protocols to develop GM crops for last 20 years. Actually there have been many cases of successful transformation of crops that were previously known very difficult in transforming. Therefore, Korean agbiotechnology arena firmly holds an infrastructure for developing GM crops with a superior technology. Then what were the problems? Why has even a single GM crop not been commercialized in Korea? The tardiness shown by business in adopting the GM crop is caused by many factors: academical weakness, poor research funding, short knowledge of risk assessment, public concern, no successful experience, lack of professional leaders on GM variety development, lack of systems toward industrialization and inappropriate target transgenes from the beginning. In order to catch up in the race for the new green industry, each one of us in private sectors alongside academia and national research institutes needs to focus altogether on what can be done best in terms of choosing crops, investing fund and establishing a road map for commercialization of GM crops.

Comparison of the SNR in the MR images on dental implant material (치아 임플란트 재료에 따른 자기공명영상의 SNR 비교)

  • Kim, Dong-Hyun;Ko, Seong-Jin;Ye, Soo-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.4
    • /
    • pp.149-155
    • /
    • 2015
  • Tooth implant is located in oral cavity and affects neck, skull base, and facail image. These magnetic inhomogeneities are usually frequency encoding direction which cause artifacts due to change of signal strength and geometric distortion. First, to evaluate signal to noise ratio (SNR) of magnetic resonance image caused by tooth implant this study uses meat phantom which is similar to human body and is consisted with fat, muscle, and water to measure signal to noise ratio. Second, signal to noise ratio by using custom-made fixed phantom is measured, and then signal to noise ratio size of different tooth implant types is compared and analyzed. The measured signal to noise ratio values of Brushite, HSA, Metal, and RBM for meat phantom were 2.76, 2.22, 1.88, and 1.57 on T1 SE, 1.88, 1.78, 1.65, and 1.79 on T2 FLAIR, 2.28, 2.25, 2.88, and 2.05 on T2 FSE, and 2.74, 1.94, 1.67, and 1.48 on T2 GRE. The measured signal to noise ratio values of Brushite, HSA, Metal, and RBM for fixed water phantom were 1.2, 1.06, 1.12, and 1.22 on DWI, 1.93, 1.87, 1.93, and 2.06 T1 SE, 1.83, 1.76, 1.82, and 1.92 on T2 FLAIR, 1.85, 1.79, 7.86, and 1.97 on T2 FSE, and 1.97, 1.93, 1.99, and 2.06 on T2 GRE. By considering through the results, patients and dentists need to consider some impacts from testing many aspects although their main purpose of having tooth implants is a dental restoration. Moreover, depending on the tooth implant characteristics of individual patients this study results can be used as baseline data when choosing test protocol.

Prediction of Maximal Oxygen Uptake Ages 18~34 Years (18~34 남성의 최대산소 섭취량 추정)

  • Jeon, Yoo-Joung;Im, Jae-Hyeng;Lee, Byung-Kun;Kim, Chang-Hwan;Kim, Byeong-Wan
    • 한국체육학회지인문사회과학편
    • /
    • v.51 no.3
    • /
    • pp.373-382
    • /
    • 2012
  • The purpose of this study is to predict VO2max with body index and submaximal metabolic responses. The subjects are consisted of 250 male aging from 18 to 34 and we separated them into two groups randomly; 179 for a sample, 71 for a cross-validation group. They went through maximal exercise testing with Bruce protocol, and we measured the metabolic responses in the end of the first(3 minute) and second stage(6 minute). To predict VO2max, we applied multiple regression analysis to the sample with stepwise method. Model 1's variables are weight, 6 minute HR and 6 minute VO2(R=0.64, SEE=4.74, CV=11.7%, p<.01), and the equation is VO2max(ml/kg/min)= 72.256-0.340(Weight)-0.220(6minHR)+0.013(6minVO2). Model 2's variables are weight, 6 minute HR, 6 minute VO2, and 6 minute VCO2(R=0.67, SEE=4.59, CV=11.3%, p<.01), and the equation is VO2max(ml/kg/min)= 68.699-0.277(Weight) -0.206(6minHR)+0.020(6minVO2)-0.009(6minVCO2). And the result did not show multicolinearity for both models. Model 2 demonstrated more correlation compared to Model 1. However, when we conducted cross-validation of those models with 71 men, measured VO2max and estimated VO2 Max had statistical significance with correlation (R=0.53, 0.56, P<.01). Although both models are functional with validity considering their simplicity and utility, Model 2 has more accuracy.