• Title/Summary/Keyword: protective gloves

Search Result 77, Processing Time 0.024 seconds

Development and Evaluation of Protective Gloves for Rose Farmers (장미재배 작업자를 위한 보호장갑의 개발과 평가)

  • Chae, Hye-Seon;Kim, Sung-Cheol;Lee, Kyung-Suk;Kim, Hyo-Cher;Kim, Doo-Hi;Park, Soon-Jee
    • The Korean Journal of Community Living Science
    • /
    • v.23 no.2
    • /
    • pp.137-144
    • /
    • 2012
  • This study was undertaken to develop protective gloves for rose farmers who work on thorny plant in Korea. Prototype of protective gloves was designed and evaluated in terms of thermal comfort and mobility. Gloves were made with arm protectors attached to them, so that they could protect the lower part of arms, and rubber bands were inserted into the arm protectors for them not to slip down. The bending part of each finger was punched in order to give ventilation. Also, the bending parts of the fingers in the upper and lower part of gloves were inserted with sponges and were stitched together in order to enhance gripping movement. According to compared evaluation of the developed gloves and the existing gloves, temperature inside the gloves didn't show any significant differences, but humidity inside the gloves showed significant differences. There were significant differences in terms of comparison of objective mobility, that is, pegboard run-time and grip power, from statistical aspects. In addition, a comparison of subjective discomfort showed significant differences and so the suitability of developed gloves was proved.

Use of Protective Gloves in Nail Salons in Manhattan, New York City

  • Basch, Corey;Yarborough, Christina;Trusty, Stephanie;Basch, Charles
    • Journal of Preventive Medicine and Public Health
    • /
    • v.49 no.4
    • /
    • pp.249-251
    • /
    • 2016
  • Objectives: Nail salon owners in New York City (NYC) are required to provide their workers with gloves and it is their responsibility to maintain healthy, safe working spaces for their employees. The purpose of this study was to determine the frequency with which nail salon workers wear protective gloves. Methods: A Freedom of Information Law request was submitted to New York Department of State's Division of Licensing Services for a full list of nail salons in Manhattan, NYC. A sample population of 800 nail salons was identified and a simple random sample (without replacement) of 30% (n=240) was selected using a random number generator. Researchers visited each nail salon from October to December of 2015, posing as a potential customer to determine if nail salon workers were wearing gloves. Results: Among the 169 salons in which one or more workers was observed providng services, a total of 562 workers were observed. For 149 salons, in which one or more worker was observed providing services, none of the workers were wearing gloves. In contrast, in six of the salons observed, in which one or more workers was providing services, all of the workers (1 in 2 sites, 2 in 1 site, 3 in 2 sites, and 4 in 1 site) were wearing gloves. Almost three-quarters of the total number of workers observed (n=415, 73.8%) were not wearing gloves. Conclusions: The findings of this study indicate that, despite recent media attention and legislation, the majority of nail salon workers we observed were not wearing protective gloves when providing services.

Mobility Evaluation of Popular Firefighting Protective Gloves in Domestic and Foreign Countries -Don-Doff Test, Dexterity Test, and Torque Test- (국내외 보급형 소방용 보호장갑의 동작성 평가 -착탈 시험, 기민성 시험, 회전력 시험을 중심으로-)

  • Kim, Dami;Lee, Inseong;Lee, Joo-Young
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.5
    • /
    • pp.921-935
    • /
    • 2016
  • This research analyzed the manual performance of firefighting protective gloves on global markets in order to suggest an evaluation method for firefighting protective gloves wearing comfort. We collected 13 types of firefighting gloves from domestic and international markets (7 types from Korea, 3 types form Europe, 2 types from the U.S and 1 type from Japan). We set the Don-Doff test as a basal requirement for moving toward to further manual performance tests that consist of: ASTM dexterity test, Minnesota dexterity test, Bennett hand tool test and ASTM torque test. All gloves were evaluated in dry and wet conditions, we included eight current male firefighters ($43.4{\pm}7.0yr$ in age, $173.1{\pm}4.4cm$ in height, $79.9{\pm}9.2kg$ in body mass) for the tests. Four gloves (1 Korea, 1 U.S, 1 Germany, and 1 Japan) out of thirteen firefighting gloves passed the Don-Doff test and had great subject preferences. There was no significant difference between dry and wet conditions on the ASTM dexterity test, Minnesota dexterity test, Bennett hand tool test and ASTM torque test. However, Japanese gloves had the greatest score and showed 3-4 times faster completion time on the ASTM dexterity test (p<.05), 1.2-1.5 times faster on the Minnesota dexterity test (p<.05), as fast as the bare hand on Bennett hand tool test (p<.05), and greater performance on the ASTM torque test compared to bare hand. In conclusion, Don-Doff test in wet conditions should be the first step for a mobility evaluation of domestic firefighting protective gloves; subsequently, a comprehensive test assorting ASTM, Minnesota, and Bennett test should be developed as a second step. The current ASTM torque test can be adopted as a third step. This three-step-method for evaluating firefighting protective glove mobility can be expected to expand into surveys of other safety gloves in Korea.

Wear Comfort of Firefighters Protective Gloves in Dry and Wet Conditions at 70℃ Air Temperature with Radiant Heat (기온 70℃의 복사열 노출 환경에서 건조와 젖은 상태의 소방용 보호장갑 착용 시 쾌적성 평가)

  • Kim, Dami;Kim, Dohyung;Lee, Joo-Young
    • Journal of Korean Living Environment System
    • /
    • v.24 no.1
    • /
    • pp.95-106
    • /
    • 2017
  • The purpose of this study was to evaluate comfort functions while wearing firefighters' protective gloves in dry and wet conditions at $70^{\circ}C$ air temperature with radiant heat. Four types of firefighting gloves from Korea, Germany, United States, and Japan were evaluated in both dry and wet conditions by eight male firefighters. Firefighters put their hands and forearms wearing gloves into a hands-radiant chamber that maintained at an air temperature of $70{\pm}2^{\circ}C$ ($T_a$) and globe temperature $106^{\circ}C$ ($T_g$). During the exposure, subjects followed a fixed protocol of manual movements and stopped the exposure when they felt being intolerable. Results showed that completion time was extended by 6 min on average when gloves got wet and 15 min for the Japanese gloves was extended when compared to its dry condition (p<.001); microclimate humidity on the palm at the last stage was greater for wet conditions than dry conditions in the all gloves; and skin temperatures on mid-fingertip, palm, and hand were significantly lower for wet conditions than dry conditions especially for Japanese gloves (p<.001). These results indicate that the exposure time without thermal pain to radiant heat could be extended by wetting gloves during the low radiant heat exposure.

Integrated Test Method by the Evaluation of Don-doff and Mobility of Old and Newly-developed Firefighting Protective Gloves (구형과 신형 소방 보호장갑의 착탈 시험 및 동작 기민성 평가를 통한 통합형 착용 시험법)

  • Bae, Gyu-Tae;Kim, Do-Hyung;Syn, Hye-Young;Lee, Joo-Young
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.5
    • /
    • pp.950-965
    • /
    • 2017
  • This present study proposed a newly developed test method to evaluate the dexterity and mobility of a firefighter's protective gloves. The first step evaluated the mobility and dexterity of the current type of fire protective gloves and three new types of protective gloves using Don-doff test, ASTM dexterity, Minnesota dexterity, Bennett hand tool test, and ASTM torque test. Three firefighters ($47.3{\pm}5.0yr$ in age, $178.6{\pm}2.9cm$ in height) participated in a series of experiments. The second step was to design and suggest an integrated test method based on the results of the first experiment. As a result of the first experiment, we concluded that 1) the mobility and dexterity tests for firefighting gloves should include both wet and dry tests, 2) The three kinds of dexterity tests could be integrated into one test, and 3) The don-doff test and the torque test should be independent from the newly developed integrated test. In summary, we suggested a simplified test method that combined ASTM dexterity, Minnesota dexterity, and Bennett hand tool test. The integrated system can reduce total time spent on dexterity tests and improve the validity of the test in terms of firefighters' manual work.

A study on wearing practice and improvement of personal protective equipment for participant handling livestock carcass infected with virulent avian infectious agents (가금류 악성 전염병 감염축 처리자의 보호 장비 착용실태 조사 및 개선에 관한 연구)

  • Lee, Hyeyeoun;Lim, Ui-Hyoung;Kim, Jong Won;Kim, Won-Il;Kang, A-Rum;Lim, Chae Woong;Hong, Chul Un;Han, Jihyeon;Kang, Seog-Jin;Kim, Bumseok
    • Korean Journal of Veterinary Service
    • /
    • v.38 no.4
    • /
    • pp.241-248
    • /
    • 2015
  • This study was aimed to investigate factors that affected the status of wearing personal protective equipment (PPE) for handling poultry carcasses with potential exposure to virulent avian infectious agents. A large outbreak of high pathogenic avian influenza (HPAI) occurred in South Korea in 2014. Many public officers participated for euthanizing and handling livestock carcass. However, several safety issues with using PPE were revealed. Therefore, a questionnaire survey was conducted for 340 people who participated euthanasia and carcass disposal in the place where HPAI mainly occurred in 2014. It was found that 31.8% of the respondents had ever taken off their protective equipment during operations because of its inconvenience. The most inconvenient PPE was goggles (54.6%), followed by mask (20.2%), latex gloves (11.6%), shoe covers (5.9%) and protective clothing (5.3%). The main complaints about this individual PPE was unclear sight, damp emitted toward eye, sweating, tearing easily and sweating, respectively. Considering such problems of PPE, new possible directions for improvement of gloves and goggles were suggested. With newly developed rubber coating fabric gloves and conventionally using latex and fabric gloves, H3N2 influenza virus transmission experiment was conducted. Rubber coating fabric gloves showed similar efficiency for blocking virus transmission with latex laboratory gloves and were not easily torn by sharp claws of chicken. In addition, air flow control safety eyewear was suggested to minimize moisture formation. The air flow control system efficiently suppressed moisture formation inside the goggles. Therefore our study will provide more specific directions about new PPE development for safety protection of actual wearers.

Knowledge, attitude, and wearing of personal protective equipment among dental hygienists in regions during the COVID-19 era (위드 코로나 시대 일부지역 치과위생사의 개인보호장구에 대한 지식, 태도 및 착용)

  • Mi-Jung Park;Jung-Hwa Lee;Kyung-Ae Jang;Hyun-Seo Yoon
    • Journal of Korean society of Dental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.163-174
    • /
    • 2024
  • Objectives: This study aimed to understand the knowledge, attitude, and wearing of four types of personal protective equipment among dental hygienists based on to the COVID-19 infection control guidelines and to provide basic data on the need to wear these equipment by dental hygienists in dental medical institutions. Methods: Between March 31 and April 26, 2022, 285 dental hygienists working at dental institutions in Busan and Gyeongsang Provinces participated in the study. Results: The higher the knowledge on personal protective equipment, the higher the glove-wearing rate; and the higher the attitude toward personal protective equipment, the higher the KF94 mask-wearing rate. Furthermore, the higher the rate of wearing face shields, the higher the rate of wearing gloves and full-body protective suits; and the higher the rate of wearing gloves, the higher the rate of wearing a full-body protective suit. Conclusions: To prevent cross-infection by dental hygienists in dental medical institutions, it is necessary to have the four types of personal protective equipment at all times and to strengthen comprehensive education on these equipment

A Study on Performance of Protective Gloves to Isocyanate Toxicity (이소시안화물 독성에 대한 보호장갑의 성능 연구)

  • Lee, Su-Gil;Pisaniello, Dino;Lee, Nae-Woo
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.62-69
    • /
    • 2008
  • As the concerns of dermal exposure of spray painters to isocyanates in the automobile industry, glove performance was examined like permeation rate and breakthrough time including fatigue test. Methylene chloride was used as the solvent for derivatization of the isocyanates with a 97.5% recovery. Ghost wipe pads were used to wipe the surface of the glove material after chemical penetration through the glove material placed under a disposable test cell. Several solvents were tested, such as thinner(xylene, toluene) and cleaning agent(acetone) by using a standard permeation test cell(AS/NZS standard 2161. part 10.3). Solvents accelerate chemical permeation through the gloves more quickly than pure HDI hardener products. The longest breakthrough times were from Nitrosolve gloves, not detected in 8 hours, compared with others like Latex, Neoprene, TNT and Dermo Plus. Therefore Nitrosolve gloves could be recommended as personal protective equipment in crash repair shops. In addition, revised exposure limit of korean regulation should be suggested for employee to minimize the risk of health symptoms.

Evaluation of Firefighting Gloves and the Behavior Regarding their Usage, of Firefighting Officials in Seoul (서울시 소방공무원의 방화장갑에 대한 평가 및 사용실태)

  • Kim, Do-Hee;Nam, Kibum;Oh, Jung-Woo;Lee, Joo-Young
    • Fashion & Textile Research Journal
    • /
    • v.23 no.4
    • /
    • pp.515-526
    • /
    • 2021
  • This study aimed to investigate the evaluation of firefighting gloves and the behavior regarding their usage, of firefighting officials in Seoul, using a questionnaire. Responses from a total of 270 firefighters who are responsible for putting out fires or undertaking rescue works in Seoul were analyzed. As per the findings, the firefighters considered ease of hand operation and fire/flame protection as the most important performance factors for firefighting gloves, and they were satisfied with the supply status of the gloves. The average number of firefighting gloves currently owned by the firefighters was 2.6 ± 0.8 pairs. Thirty-nine percent of the respondents said that their firefighting gloves lasted, with maintained performance, for more than six months and less than a year, and when asked how they handled the gloves with degraded performance, 46% of them said that they would discard them. Sixty-eight percent of the respondents said that they used the most recently developed and supplied gloves, which they considered as the most satisfying gloves and which they mainly used these days. Respondents were highly satisfied with the fire/flame protection performance of their firefighting gloves, but were less satisfied, however, with the glove fit. These results suggest that there has been a significant improvement in the overall performance level and supply status of the firefighting gloves. Given the current situation, careful considerations with flexible approaches are needed on the current firefighting gloves size system as well as on the personal protective equipment maintenance and management scheme.

Assessment of Worker's Diisocyanates Skin Exposure at Polyurethane Foam Manufacturing Companies (우레탄 폼 제조 사업장 작업자의 디이소시아네이트 피부노출 평가)

  • Jeong, Jee Yeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.2
    • /
    • pp.57-64
    • /
    • 2013
  • Objectives: Skin exposure to diisocyanates may be an important risk factor for respiratory sensitization to leading asthma. However little is known about the extent of worker's diisocyanates skin exposure and the effectiveness of personal protective equipments in polyurethane foam manufacturing companies. This study provides data on diisocyanates skin exposure, surface diisiocyantes contamination of foams and the effectiveness of personal protective gloves in five polyurethane foam manufacturing companies. Materials and methods Colorimetric SWYPE pads are used for the determination of diisocyanates on surfaces of workers skin and polyurethanes foams. Results: The forearms, necks and faces of workers in polyurethane foam manufacturing companies were found to be contaminated with diisocyanates. Heavy contamination with uncured diisocyanates at large block foams surfaces were found. Personal gloves of workers for skin protection showed significant penetrations by diisocyanates. Conclusions: We found that all workers in polyurethane foam manufacturing companies could be exposed to diisocyanates by skin exposure. Also further researches which would better quantify skin exposure are needed.