• Title/Summary/Keyword: protection resistor

Search Result 32, Processing Time 0.035 seconds

Algorithm of intelligent SPS with applying fast-valving and braking resistor (Fast-valving과 Braking resistor 적용을 통한 지능형 SPS 알고리즘 구현)

  • Kim, Kab-Yong;Yoon, Dong-Hee;Jang, Gil-Soo;Moon, Young-Hwan;Kim, Seog-Joo;Seo, Sang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.280-281
    • /
    • 2011
  • Special Protection Scheme(SPS) that operates scenarios about faults beyond the normally protective action is wide system protection technology for the purpose of wide areas protection. Therefore, the SPS focuses on the improvement of the power supply capability by protecting the system rather than protecting the system equipments. Since the SPS requires emergency operation, the operation schedule is set up in advance by analyzing various scenarios. Since the SPS's action scheme uses generator tripping and is a classical method it is presently the most powerful one. However, as the setting of SPS is set to the most severe disturbance, the scheme tends to trip more generators than required to prevent fault propagation. It is highly likely that tripping generator units to prevent fault propagation would result in difficulty of system management and possibility of load shedding. Accordingly, it is desirable that generators are connected to the system within the range that ensures system stability and intelligent SPS is currently under development to solve the problem being stated. In this paper, as a part of developing the intelligent SPS, application of the fast-valving and braking resistor scheme to the generators is being proposed and analysed to reduce the number of tripped generators.

  • PDF

Energy extraction system using dual-capacitor switching for quench protection of HTS magnet

  • Choi, Yojong;Lee, Woo Seung;Song, Seunghyun;Jeon, Haeryong;Kang, Hyoungku;Ko, Tae Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.3
    • /
    • pp.49-53
    • /
    • 2017
  • The superconducting magnets have a large inductance as well as high operating current. Therefore, mega-joule scale energy can be stored in the magnet. The energy stored in the magnet is sufficient to damage the magnet when a quench occurs. Quench heater and dump resistor can be used to protect the magnet. However, using quench heater to create quench resistors through heat transfer can be slower than instantly switching resistors. Also, electrical short, overheating and breakdown can occur due to quench heater. Moreover, the number of dump resistor should be limited to avoid large terminal voltage. Therefore, in this paper, we propose a quench protection method for extracting the energy stored in a magnet by charging and discharging energy through a capacitor switching without increasing resistance. The simulation results show that the proposed system has a faster current decay within the allowable voltage level.

NAC Measurement Technique on High Parallelism Probe Card with Protection Resistors

  • Kim, Gyu-Yeol;Nah, Wansoo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.5
    • /
    • pp.641-649
    • /
    • 2016
  • In this paper, a novel time-domain measurement technique on a high parallelism probe card with protection resistors installed is proposed. The measured signal amplitude decreases when the measurement is performed by Needle Auto Calibration (NAC) probing on a high parallelism probe card with installed resistors. Therefore, the original signals must be carefully reconstructed, and the compensation coefficient, which is related to the number of channel branches and the value of protection resistors, must be introduced. The accuracy of the reconstructed signals is analyzed based on the varying number of channel branches and various protection resistances. The results demonstrate that the proposed technique is appropriate for evaluating the overall signal performance of probe cards with Automatic Test Equipment (ATE), which enhances the efficiency of probe card performance test dramatically.

Quench analysis and protection circuit design of a superconducting magnet system for RISP 28GHz ECR ion source

  • Song, S.;Ko, T.K.;Choi, S.;Ahn, M.C.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.2
    • /
    • pp.37-41
    • /
    • 2016
  • This paper presents the developed quench analysis code and protection circuit design for a superconducting magnet system of 28GHz electron cyclotron resonance (ECR) ion source. The superconducting magnet is composed of a hexapole magnet and four solenoid magnets located outside of the hexapole one. All magnets are wound with NbTi composite wire and impregnated by epoxy. By using the developed characteristic analysis code, the normal zone resistance, decaying current and temperature rising can be estimated during quench. Also, the stored magnetic energy is successfully consumed from the series resistor of the designed protection circuit. The analytical results are compared with the experimental results to verify the developed quench analysis code and protection circuit.

Design of Low-Melting Metal Fuse Elements of Current Sensing Type Protection Device for Large Capacity Secondary Battery Protection System (대용량 이차전지 보호 시스템용 전류 감지 동작형 보호소자의 저융점 금속 가용체 설계)

  • Kim, Eun Min;Kang, Chang yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.6
    • /
    • pp.427-432
    • /
    • 2018
  • High-capacity secondary batteries can cause explosion hazards owing to microcurrent variations or current surges that occur in short circuits. Consequently, complete safety cannot be achieved with general protection that is limited to a mere current fuse. Hence, in the case of secondary batteries, it is necessary for the protector to limit the inrush current in a short circuit, and to detect the current during microcurrent variations. To serve this purpose, a fuse can be employed for the secondary battery protection circuit with current detection. This study aims at designing a protection device that can stably operate in the hazardous circumstances associated with high-capacity secondary batteries. To achieve the said objective, a detecting fuse was designed from an alloy of low melting point elements for securing stability in abnormal current states. Experimental results show that the operating I-T and V-T characteristic constraints can be satisfied by employing the proposed current detecting self-contained low melting point fuse, and through the resistance of the heating resistor. These results thus verify that the proposed protection device can prevent the hazards of short circuit current surges and microcurrent variations of secondary batteries.

The study of the protection circuit about overvoltage between excitation system and synchronous machines (여자시스템과 동기발전기의 회전자 권선에 발생되는 과전압에 대한 보호회로 연구)

  • 류호선;임익헌
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.188-192
    • /
    • 1997
  • In the case of synchronous machines, certain power system disturbances cause the induced rotor current to assume negative values when no static converter is present. A converter, however, prevents negative current from flowing, so that overvoltages occur. The overvoltages can be effectively limited as crowbar circuit using GTO. This newly proposed crowbar circuit with current limiting resistor absorbs energy when overvoltage comes from power system repeatedly and verified through experiment

  • PDF

Build-up of DC/Impulse Superposition Testing System for XLPE materials in HVDC cables (HVDC 케이블용 XLPE 절연 재료에 대한 DC/Impulse 중첩실험 시스템 구축)

  • Kim, Jeong-Tae;Kim, Dong-Uk
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1608-1609
    • /
    • 2011
  • In this study, in order to develop the evaluation method for XLPE materials for HVDC cables, DC/Impulse superposition testing system was builded up. Throughout the P-spice simulation, optimal values of the protection resistor for the DC generation system and the blocking capacitor for the Impulse generator were calculated. DC/Impulse superposition system showed good result maintaining their proper wave shapes and amplitudes. This system would be planned to apply to the evaluation of XLPE materials for HVDC cables.

  • PDF

Crowbar Circuit for the Overvoltage Protection Using GTO (GTO를 이용한 과전압 억제용 크로바 회로)

  • Ryu, Ho-Seon;Lim, Ick-Hun
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.343-345
    • /
    • 1996
  • In the case of synchronous machines, certain power system disturbances cause current to assume negative values when no static converter is present. But the converter prevents negative current from flowing, so that overvoltages occur. The overvoltages can be effectively limited as crowbar circuit using GTO. The crowbar circuit with current limiting resistor absorbs energy when overvoltage comes from power system repeatedly. The newly proposed circuit is verified through simulation and experiment

  • PDF

Design of Fuse Elements of Current Sensing Type Protection Device for Portable Secondary Battery Protection System (휴대용 이차전지 보호 시스템용 전류 감지 동작형 보호소자의 퓨즈 가용체 설계)

  • Kang, Chang-Yong;Kim, Eun-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1619-1625
    • /
    • 2018
  • Portable electronic devices secondary batteries can cause fire and explosion due to micro-current change in addition to the situation of short-circuit inrush current, safety can not be secured with a general operation limited current fuse. Therefore, in secondary battery, it is necessary for the protector to satisfy both the limit current type operation in the open-short-circuit inrush current and the current detection operation characteristic in the micro current change situation and for this operation, a fuse for the current detection type secondary battery protection circuit can be applied. The purpose of this study is to design a protection device that operates stably in the hazardous situation of small capacity secondary battery for portable electronic devices through the design of low melting fuse elements alloy of sensing type fuse and secures stability in abnormal current state. As a result of the experiment, I-T and V-T operation characteristics are satisfied in a the design of the alloy of the current sensing type self-contained low melting point fuse and the resistance of the heating resistor. It is confirmed that it can prevent accidents of short circuit over-current and micro current change of secondary battery.

A Study on the Protection Methods of Sheath Circulating Current Reduction Device in Transient State (과도상태에서의 시스순환전류 저감장치 보호방안에 관한 연구)

  • Kang, Ji-Won;Jung, Chae-Kyun;Lee, Jong-Beom;Lee, Dong-Il;Jung, Gil-Jo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.53-58
    • /
    • 2002
  • Sheath circulating current is increased as the change of sheath mutual impedance which is caused by imbalance of cable system, and different section length between joint box. If excessive current flows in sheath. sheath loss will be increased and then transmission capacity of underground transmission system is reduced. Accordingly, This paper proposed sheath current reduction device using resistor and reactor and proved the reduction effect of that device using EMTP/ATP. And also in this paper, when transients are occurred at the underground system with reduction device by ground fault and lightning surge. we analyzes transient effect of system variously. From this result. authors establish the protection methods of sheath circulating current reduction device.

  • PDF