• 제목/요약/키워드: protection of design

Search Result 2,368, Processing Time 0.033 seconds

Design and Development Status of a Thermal Protection System for a Spaceplane (우주비행기 열보호 시스템의 설계 및 개발 현황)

  • Yoon, Yong-Sik;Choi, Gi-Hyuk
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.3
    • /
    • pp.79-85
    • /
    • 2018
  • The demand for the development of atmospheric entry vehicles, dealing with reentry and solar-system planet exploration, is increasing. Generally, atmospheric drag and heating accompany the entry into atmospheric air. Accordingly, the selection of the thermal protection materials and the design and application of the thermal protection system are very important. In this paper, the atmospheric entry environment and the type and characteristics of the thermal protection materials are discussed. The design and application status of a thermal protection system for spaceplanes are described.

A Study on the Development of Computer Software for the Design of Fire Protection System (방화설비계통 설계용 전산소프트웨어 개발에 관한 연구)

  • 이정혜
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.3
    • /
    • pp.275-284
    • /
    • 1998
  • Standard on the carbon dioxide extinguishing system was prepared by the committed of the national fire protection assocition(NFPA)in USA on 1980. And this code is also applied to the design of a marine fire extinguishing system The most important problem in design is the uniform discharge of $CO_2$ through each nozzle from the high pressure $CO_2$ storage facility. The purpose of this paper is to develop the computer software to design the marine fire protection piping system. By solving the continuity equation energy equation and Bernoulli's equation simulataneously the flowrate in branch pipelines and discharge nozzles can be calculated.

  • PDF

A study of Chinese fashion design copyright protection cases - Highlighting infringement cases involving the intellectual property rights of Bai Yi Bei in 2023 - (중국 패션디자인 저작권 보호 판례 고찰 - 2023년 백일배(百一杯) 지식재산권 판례를 중심으로 -)

  • Yueding Zhou;Hyunzin Ko
    • The Research Journal of the Costume Culture
    • /
    • v.32 no.2
    • /
    • pp.287-298
    • /
    • 2024
  • Clothing is intimately intertwined with daily lives as every individual relies on it. The pervasive issue of plagiarism in the fashion industry has led to an increased demand to protect intellectual property rights. Currently, studies on the protection of fashion design intellectual property rights in China remain in the exploratory stage and warrant further investigation. This paper addresses the issue in two parts. The first part contains an analysis of the theoretical foundation for the protection of fashion design copyrights. It is further divided into three subsections. The first subsection primarily examines the concept of copyrights and laws. The second subsection focuses on the concept of fashion design copyrights and laws. The third subsection analyzes copyright laws concerning fashion designs in China. The second section offers an analysis of infringement cases involving fashion designs published during the Baiyi Cup Intellectual Property Case Summary Writing Competition held in China in 2023. It outlines the shortcomings of the current Chinese copyright laws regarding the protection of fashion designs, and proposes measures for improvement. This study argues that the institutional framework for intellectual property rights in the Chinese fashion industry should align with practical considerations and explores suitable legal regulations and how they relate to specific circumstances in China. Besides refining the legal framework, fashion designers and enterprises must take measures to entablish the intellectual property rights of their clothing brands.

Review of Code Provisions on Seismic Design of Fire Protection System (소방설비 내진설계에 관한 각국 기준 비교 연구)

  • Lee, Hyun-Jin;Shin, Yi-Chul;Lee, Jae-Young;Seo, Dong-Goo;Han, Byung-Chan;Kim, Jae-Hwan;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.238-241
    • /
    • 2008
  • In this paper, provisions related with the seismic design and equipments of fire protection system are being considered. The provisions from various international codes on seismic design fire protection system were reviewed. The codes, reviewed are, Japanese code, NFPA guideline and Korean code. It is noted that all the codes excepted to korean code consider earthquake effect to evaluate seismic forces and behaviors. But, korean provision are not covered in seismic response in all. A brief description on limitations in korean code is also presented.

  • PDF

Advanced Cathodic Protection Modeling Associated with Coating Degradation Conditions

  • Im, Gwan-Jin;Kim, Ki-Joon;Lee, Myung-Hoon
    • Corrosion Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.177-183
    • /
    • 2009
  • There are two effective methods in use to protect ship ballast tank against corrosion. One is paint coating and the other cathodic protection(CP). The conventional cathodic protection design has mainly relied on the expert's experience. During the last two decades computer modeling has been significantly developed as an advanced design technology for cathoidic protection systems not only for ships, but also for offshore structures. However the present computer modeling of cathodic protection systems have some limitations simulating corrosion in the ballast tank with a deteriorated coating. In this study, "coating breakdown factor" considering coating degradation states with time has been attempted to improve the cathodic protection modeling using the data from literatures.

REAL-TIME PERSONAL DOSE MEASUREMENT AND MANAGEMENT SYSTEM RESEARCH IN CHINA

  • Zhang, Z.Y.;Cheng, C.;Liu, Z.S.;Yang, H.T.;Deng, C.M.;Zhang, X.;Guo, Z.J.
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.281-286
    • /
    • 2001
  • The composition and design of a real-time personal dose measurement and management system are described in this paper. Accordingly, some pertinent hardware circuits and software codes including their operation modes have also been presented.

  • PDF

Design Methodology of the Bus Configuration and Protection Coordination Basic Logics of Power Substation Using EMTP-RV (EMTP-RV를 이용한 변전소 모선 방식과 보호협조 기초 논리 설계 방법론에 대한 연구)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1129-1138
    • /
    • 2019
  • Since substations are structurally complex due to the concentration of protection coordination facilities with substation facilities for long distance power transmission, it is difficult to design a protection coordination system to minimize the spreading effect of the fault when a fault occurs on transmission line or distribution line. Therefore, in this paper, the bus configuration and the basic logic of protection coordination that have a major influence on the reliability of substation power supply were analyzed, and the substation protection coordination logic to detect internal and external faults was developed based on EMTP-RV. As the basic logic of substation protection coordination, the percent differential protection relay logic for substation internal fault detection and the overload protection relay logic for inference of external failure were modeled. Finally, the 154kV substation including the protection coordination logic was modeled using EMTP-RV, and the effectiveness of the protection coordination design methodology was confirmed through the several fault simulation cases based on EMTP-RV.

Design of Lightning Induced Transient Protection Circuit for Avionics Equipment Considering Parasitic Inductance (기생 인덕턴스를 고려한 항공기 탑재장비의 간접낙뢰 보호회로 설계)

  • Sim, Yong-gi;Cho, Seong-jin;Kim, Sung-hun;Park, Jun-hyun;Han, Jong-pyo
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.5
    • /
    • pp.459-465
    • /
    • 2017
  • In this paper, we introduce the design consideration of the lightning induced transient protection circuit for the indirect lightning strike on the avionics equipment. The lightning induced surge voltage, which is so-called as indirect effects of lightning, may cause a functional failure or physical damage to the electrical and electronic equipment of aircraft. In order to protect the electrical and electronic equipment of aircraft from the indirect effects of lightning, we should analyze the effect of lightning strike on aircraft and consider applying protection design for each avionics device. However, lightning induced transient protection circuits can have unintended consequences because parasitic inductance elements are exist in PCB and TVS diodes. In this paper, we introduce the design method of the protection circuit considering the parasitic inductance of the protection circuit. In addition, we show the result of verification test performed to validate the protection circuits for indirect effects of lightning.

A Study on the fire-resistance of concrete-filled steel square tube columns without fire protection under constant central axial loads

  • Park, Su-Hee;Choi, Sung-Mo;Chung, Kyung-Soo
    • Steel and Composite Structures
    • /
    • v.8 no.6
    • /
    • pp.491-510
    • /
    • 2008
  • This paper presents a plan and guidelines that were drawn for Korean based research carried out on the fire-resistance of CFT columns. This research was carried out by reviewing the Korean regulations related to the fire-resistance of CFT columns and examining studies which had been made in Korea as well as overseas. The first phase of the study plan was to compare the fire-resistance of square CFT columns without fire protection (obtained through fire-resistance tests and numerical analyses) with estimated values (obtained through fire-resistance design formulas proposed in Korea and overseas). This comparison provided conclusions as outlined below. Fire-resistance tests conducted in this study proved that, when the actual design load is taken into consideration, square CFT columns without fire protection are able to resist a fire for more than one hour. A comparison was made of test and analysis results with the fire-resistance time based on the AIJ code, the AISC design formula and the estimation formula suggested for Korea. The results of this comparison showed that the test and analysis results for specimens SAH1, SAH2-1, SAH2-2 and SAH3 were almost identical with the AIJ code, the AISC design formula and estimation formula. For specimens SAH4 and SAH5, the estimation formula was more conservative than the AIJ code and the AISC design formula. It was necessary to identify the factors that have an influence on the fire-resistance of CFT columns without fire protection and to draw fire-resistance design formulas for these columns. To achieve this, it is proposed that numerical analyses and tests be conducted in order to evaluate the fire-resistance of circular CFT columns, the influence of eccentricity existing as an additional factor and the influence of the slenderness ratio of the columns. It is also suggested that the overall behavior of CFT structures without fire protection within a fire be evaluated through analysis simulation.

A Study on the Design of the Output ESD Protection Circuits and their Electrical Characteristics (출력단 ESD 보호회로의 설계 및 그 전기적 특성에 관한 연구)

  • 김흥식;송한정;김기홍;최민성;최승철
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.11
    • /
    • pp.97-106
    • /
    • 1992
  • In integrated circuits, protection circuits are required to protect the internal nodes from the harmful ESD(Electrostatic discharge). This paper discusses the characteristics of the circuit components in ESD protection circuitry in order to analyze the ESD phenomina, and the design methodalogy of ESD protection circuits, using test pattern with a variation of the number of diode and transistor. The test devices are fabricated using a 0.8$\mu$m CMOS process. SPICE simulation was also carried out to relate output node voltage and measured ESD voltage. With increasing number of diodes and transistors in protection circuit, the ESD voltage also increases. The ESD voltage of the bi-directional circuit for both input and output was 100-300[V], which in higher than that of only output(uni-directional) circuit. In addition, the ESD protection circuit with the diode under the pad region was useful for the reduction of chip size and parasitic resistance. In this case, ESD voltage was improved to a value about 400[V].

  • PDF