Prediction of the Blast Wave Propagation Over a Kick Motor Test Facility (Kick Motor 시험장 충격파 전파 예측)

  • Ok, Ho-Nam;Kim, In-Sun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.220-223
    • /
    • 2008
  • A test facility to measure the performance of a KM(Kick Motor) is constructed, and prediction of blast wave propagation over the facility is performed to check if the safety of test personnel in MCC(Main Control Center) can be guaranteed even for the most severe explosion. Assuming that the initial explosion energy is contained in a sphere under the pressure of 500, 1000, 1500 psi, respectively, the radius of the sphere is determined for each pressure to set the mass of contained explosion gas to 35 kg. The material properties of explosion gas are set to be the ones of KM propellant combustion gas under normal condition. To reduce the effort and time required for a complex three-dimensional modeling, the flowfield is approximated to axismmetry. Calculations are performed for all three initial pressure conditions, and the analysis of the result is given for 1500 psi which is expected to be the worst case. The maximum pressure is 3.5 psig while the minimum pressure is -1.2 psig on the outer wall of MCC, and the maximum pressure difference between the inner and outer walls of protection wall amounts to 3.0 psi.

  • PDF

Application on the New Technology of Construction Structures Disaster Protection Management based on Spatial Information

  • Yeon, Sangho
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.10 no.3
    • /
    • pp.136-145
    • /
    • 2018
  • The disaster monitoring technique by combination of the measurement method and the fine precision of the sensor collecting the satellite-based information that can determine the displacement space is available in a variety of diagnostic information and the GIS/GNSS by first sensor it is being requested from them. Be large and that the facility is operated nationally distributed torsional displacement of the terrain and facilities caused by such natural disasters progress of various environmental factors and the surroundings. To diagnose this spatial information, which contains the various sensors and instruments tracks the precise fine displacement of the main construction structures and the first reference in the Geospatial or more three-dimensional detailed available map and location information using the installed or the like bridges and tunnels produced to a USN/IoT change at any time, by combining the various positioning analysis of mm-class for the facility main area observed is required to constantly in the real time information of the USN/IoT environment sensor, and to utilize this as a precise fine positioning information by UAV/Drone to the precise fine displacement of the semi-permanent infrastructures. It managed to be efficient management by use of new technologies, analyzing the results presented to a method capable of real-time monitoring for a large structure or facility to construction disaster prevention.

Path planning in nuclear facility decommissioning: Research status, challenges, and opportunities

  • Adibeli, Justina Onyinyechukwu;Liu, Yong-kuo;Ayodeji, Abiodun;Awodi, Ngbede Junior
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3505-3516
    • /
    • 2021
  • During nuclear facility decommissioning, workers are continuously exposed to high-level radiation. Hence, adequate path planning is critical to protect workers from unnecessary radiation exposure. This work discusses recent development in radioactive path planning and the algorithms recommended for the task. Specifically, we review the conventional methods for nuclear decommissioning path planning, analyze the techniques utilized in developing algorithms, and enumerate the decision factors that should be considered to optimize path planning algorithms. As a major contribution, we present the quantitative performance comparison of different algorithms utilized in solving path planning problems in nuclear decommissioning and highlight their merits and drawbacks. Also, we discuss techniques and critical consideration necessary for efficient application of robots and robotic path planning algorithms in nuclear facility decommissioning. Moreover, we analyze the influence of obstacles and the environmental/radioactive source dynamics on algorithms' efficiency. Finally, we recommend future research focus and highlight critical improvements required for the existing approaches towards a safer and cost-effective nuclear-decommissioning project.

A Study on the Fire Impact of Adjacent Storage at Outdoor Storage Fire (옥외저장소 화재 시 인접 저장소 화재 영향에 대한 연구)

  • Eun-Ji Kim;Sung-Seek Park;Yong-Han Jeon
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.3
    • /
    • pp.93-100
    • /
    • 2024
  • Outdoor storage fires have a significant impact on the surrounding environment, including adjacent storage facilities and buildings. Therefore, it is essential to review and manage the fire impact to minimize damage to human life and property on the outdoor storage fires. In this study, the heat release rate and radiant heat flux were simulated according to the fire time, wind veolcity, and presence or absence of water spray equipment in an outdoor storage facility fire, and the fire impact was analyzed. The outdoor storage was designed to simulate two scenarios on the outdoor storage fires containing gasoline, and FDS was used for fire simulation. As a results, when the water spray facility was not operating and the wind velocity was 5 m/s, the maximum radiant heat flux was 24.80 kW/m2, which exceeded the limit radiant heat flux of 20 kW/m2. When the water spray facility was operating and the wind veolcity was 10 m/s, the maximum radiant heat flux was 18.77 kW/m2, which did not exceed the limit radiant heat flux, indicating that the fire impact on adjacent storage facilities was relatively small.

Estimation of Uranium Particle Concentration in the Korean Peninsula Caused by North Korea's Uranium Enrichment Facility (북한 우라늄 농축시설로 인한 한반도에서의 공기중 우라늄 입자 농도 예측)

  • Kwak, Sung-Woo;Kang, Han-Byeol;Shin, Jung-Ki;Lee, Junghyun
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.3
    • /
    • pp.127-133
    • /
    • 2014
  • North Korea's uranium enrichment facility is a matter of international concern. It is of particular alarming to South Korea with regard to the security and safety of the country. This situation requires continuous monitoring of the DPRK and emergency preparedness on the part of the ROK. To assess the detectability of an undeclared uranium enrichment plant in North Korea, uranium concentrations in the air at both a short and a long distance from the enrichment facility were estimated. $UF_6$ source terms were determined by using existing information on North Korean facility and data from the operation experience of enrichment plants from other countries. Using the calculated source terms, two atmospheric dispersion models (Gaussian Plume Model and HYSPLIT models) and meteorological data were used to estimate the uranium particle concentrations from the Yongbyon enrichment facility. A maximum uranium concentration and its location are dependent upon the meteorological conditions and the height of the UF6 release point. This study showed that the maximum uranium concentration around the enrichment facility was about $1.0{\times}10^{-7}g{\cdot}m^{-3}$. The location of the maximum concentration was within about 0.4 km of the facility. It has been assumed that the uranium sample of about a few micrograms (${\mu}g$) could be obtained; and that few micrograms of uranium can be easily measured with current measurement instruments. On the contrary, a uranium concentration at a distance of more than 100 kilometers from the enrichment facility was estimated to be about $1.0{\times}10^{-13}{\sim}1.0{\times}10^{-15}g{\cdot}m^{-3}$, which is less than back-ground level. Therefore, based on the results of our paper, an air sample taken within the vicinity of the Yongbyon enrichment facility could be used to determine as to whether or not North Korea is carrying out an undeclared nuclear program. However, the air samples taken at a longer distance of a few hundred kilometers would prove difficult in detecting a clandestine nuclear activities.

Optimal deployment strategy of patriot missile (패트리어트 (patriot) 미사일의 최적 배치)

  • 김영휘;김성인;오원민
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1994.04a
    • /
    • pp.29-37
    • /
    • 1994
  • It is reported that north Korea has already developed 1,500 to 2,000-km-range Scud missile. As a defensive strategy against Scud attack on military and civilian facilities the military authorities are considering deployment of Patriot missile. This paper deals with its optimal deployment strategy. In this problem a Patriot missile which has multiple-facility responsibility may be able to protect each of its assigned facilities only with a certain probability, not absolute protection, and it may not be adequate to have only a single missile protect a facility, either because of its operational reliability or because of its limited availability at any given point in time. We formulate this problem into the probabilistic partial set covering model developed by Sherali and Kim. The applicability, verification and validation of the model are tested via an abbreviated case study.

Offsite Risk Assessment on Chloric Acid Release (염산취급시설의 사고시 사업장외에 미치는 영향평가)

  • Park, Kyoshik
    • Korean Chemical Engineering Research
    • /
    • v.54 no.6
    • /
    • pp.781-785
    • /
    • 2016
  • Chloric acid is a toxic chemical and the risk of facility handling chloric acid was assessed from the list of accident scenario to provide countermeasure to keep the vicinity safe. Accident scenarios were listed by using MSDS and process safety information. The scenarios having effect to the off-site were selected and assessed further according to guideline provided by Korea government. Worst case and alternative scenarios including other interested scenarios were evaluated using ALOHA. Each evaluated scenario was assessed further considering countermeasures. The results showed that the facility handling chloric acid is safe enough and needed no further protections at the moment.

Analysis on the Characteristics of the Precedents for Industrial/Technological Cultural Properties of the Hansa Coking Plant (독일 산업·기술문화재 한자 코크스 제조소 재생사례 분석)

  • Kim, Hong-Gi;Park, Chang-Ho
    • Journal of the Korea Furniture Society
    • /
    • v.27 no.1
    • /
    • pp.59-68
    • /
    • 2016
  • The Industrial/Technological Cultural Properties are being protected, the rest facing with demolition and damages. In order to better cope with such situation, Korea has officially introduced the Registered Cultural Properties System since 2001 and began acknowledging the historical values of industrial buildings as modern cultural properties. In the Nordrhein-Westfalen, Germany, there are approximately 3,500 industrial buildings under the cultural asset protection and management not only in the Ruhr-region but also state-wide. Among these, this case study focuses on the Hansa Coking Plant, a large-scale Revitalization project to rehabilitate the old industrial complexes and facility buildings that have been shut down on December 15, 1992. Purpose of this study is to analyze main project plans of each facility in the Hansa Coking Plant and to bring out the main features of the plans, so that they can be utilized to find suggestions for Industrial/Technological Cultural Properties Revitalization in Korea.

A Study on Noise in Waste Facilities (폐기물 소각시설 내부 소음에 관한 연구)

  • Seo, Byung-Suk;Park, Ro-Gook;Jeon, Yong-Han
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.2
    • /
    • pp.15-21
    • /
    • 2020
  • Industrial facilities need design to predict and reduce noise from design to prevent and reduce noise. The purpose of this study is to predict worker's environment and evaluate safety by analyzing noise inside underground blower room and air compressor room with fluid machinery in waste facility. This waste incineration facility was analyzed based on the ground floor, ground floor blower chamber, and air compressor chamber. The results of SPL(Sound Pressure Level) analysis at 1.5m away, which are frequently used to measure the SPL as a noise source, are as follows. SPL of basement level: 46.80[dB], SPL of ground layer: 48.57[dB]. As a result, it was expected that the noise level would be considerably lower than the 8 hours 50[dB] noise exposure per day.

Introduction of Fire Protection Technology and Its Design Method of Offshore Facilities (해양플랜트의 방화대책 및 설계기술 소개)

  • Koo, Myeong Jun;Choi, Jae Woong;Yoon, Ho Byung
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.1
    • /
    • pp.49-57
    • /
    • 2013
  • The dimensioning accidental loads have been selected through suitable quantitative risk assessment and generally utilized important factors for offshore facility design. The fire hazard can be quantified with dimensioning fire loads. The main purposes of fire protection are to maintain the functionality of safety systems within evacuation period and to prevent the escalation from initial fire to uncontrolled catastrophic fire. This paper introduces the applications and the design methods of active and passive fire protections as representative measures of fire protection of offshore facilities. The passive fire protection requires the high initial installation cost and much difficulty on the operation of facilities and their maintenance. The oil major clients have asked the design contractors of offshore facilities to optimize the amount of passive fire protection with relevant engineering technology recently.