• Title/Summary/Keyword: prosthetics

Search Result 208, Processing Time 0.02 seconds

Comparison of compressive fracture strength of small dog dental prosthesis along the direction of bite force (교합력의 방향에 따른 소형견 치과보철물의 압축파절강도 비교)

  • Park, yujin;Choi, sungmin
    • Journal of Technologic Dentistry
    • /
    • v.42 no.2
    • /
    • pp.129-137
    • /
    • 2020
  • Purpose: The aim of this study is to observe the compressive fracture strength of the crown according to the direction of the occlusal force of the mandibular canine and carnassial of the small dog. Methods: The abutment models of mandibular canine and carnassial were prepared, specimens of zirconia, PMMA and Ni-Cr alloy were produced. The experimental jig was fabricated with Co-Cr alloy and buried in acrylic resin after make tilt to specified angle. The specimen was attached to a jig and loaded using a universal testing machine until the specimen fractured. Results: The compressive fracture strengths of CXZ and CXP specimens were found to be 999.21 ± 31.15 N on average and 731.42 ± 59.13 N on average. And CZZ and CZP specimens were 730.48 ± 70.14 N on average and 377.65 ± 11.87 N on average. CXN and CZN specimens were not fractured. In addition, MZZ and MZP specimens were 746.46 ± 50.75 N and 258.64 ± 31.86 N on average. The MZN specimens were not fractured. Conclusion: Zirconia has compressive fracture strength that can be applied to small dog's canine and Carnassial prosthetics, while PMMA has inadequate strength to small dog's carnassial prosthesis.

Case Study of Working Environment Improvement at Plastic Product Companies for Reducing the Musculoskeletal Disorders Risk Factors (근골격계 질환 유해요인 감소를 위한 플라스틱 제품 제조업체의 작업환경 개선 사례연구)

  • Kang, Young-Sig;Cho, Mun-Son;Yang, Sung-Hwan
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.2
    • /
    • pp.51-57
    • /
    • 2009
  • The goal of this study is to propose the effective method of investigating the injurious factors and make improvement plans that prevents the workers against musculoskeletal disorders at plastic product companies and the same business field with similar working conditions and process. A questionnaire are adopted to analyze the symptoms of workers' musculoskeletal disorders, and ergonomic assessment methods such as RULA, OWAS are performed to find out harmful factors of workplace and working posture. Based on the result of the evaluation, to enhance the working environment, improvement of worktable, working space, tools, and outfit was suggested, and induction of mechanical system was also suggested. It can be concluded that the method and process described in this paper could be helpful for diagnosing the musculoskeletal disorders risk factors and making improvement plans to the plastic product companies and the same business field with similar working conditions and process.

Case Study of Diagnosis on Musculoskeletal Disorders Risk Factors at an Diesel Engine Fuel Injection System Manufacturing Company (디젤엔진용 연료분사장치 제조업체의 근골격계 질환 유해요인 조사 사례연구)

  • Yang, Sung-Hwan;Cho, Mun-Son;Kang, Young-Sig
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.2
    • /
    • pp.59-67
    • /
    • 2009
  • The goal of this study is to propose the effective method of investigating the injurious factors and making improved plans that prevents the workers against musculoskeletal disorders at an diesel engine manufacturing company and the same business field with similar working conditions and process. A questionnaire were adopted to analyze the symptoms of workers' musculoskeletal disorders, and an ergonomic assessment method such as RULA, OWAS were performed to find out harmful factors of workplace and working posture. Based on the result of the evaluation, to enhance the working environment, improvement of worktable, working space, tools, and outfit was suggested, and induction of mechanical system was also suggested. It can be concluded that the method and process described in this paper could be helpful for diagnosing the musculoskeletal disorders and making improvement plans to the diesel engine fuel injection system manufacturing company and the same business field with similar working conditions and process.

Clinical outcome of double crown-retained implant overdentures with zirconia primary crowns

  • Rinke, Sven;Buergers, Ralf;Ziebolz, Dirk;Roediger, Matthias
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.329-337
    • /
    • 2015
  • PURPOSE. This retrospective study aims at the evaluation of implant-supported overdentures (IODs) supported by ceramo-galvanic double crowns (CGDCs: zirconia primary crowns + galvano-formed secondary crown). MATERIALS AND METHODS. In a private practice, 14 patients were restored with 18 IODs (mandible: 11, maxilla: 7) retained by CGDCs on 4 - 8 implants and annually evaluated for technical and/or biological failures/complications. RESULTS. One of the 86 inserted implants failed during the healing period (cumulative survival rate (CSR) implants: 98.8%). During the prosthetic functional period (mean: $5.9{\pm}2.2years$), 1 implant demonstrated an abutment fracture (CSR-abutments: 98.2%), and one case of peri-implantitis was detected. All IODs remained in function (CSR-denture: 100%). A total of 15 technical complications required interventions to maintain function (technical complication rate: 0.178 treatments/patients/year). CONCLUSION. Considering the small sample size, the use of CGDCs for the attachment of IODs is possible without an increased risk of technical complications. However, for a final evaluation, results from a larger cohort are required.

Attitude and treatment options in implant-supported prosthetics: A survey among a cohort of German dentists

  • Glucker, Carolin;Rauch, Angelika;Hahnel, Sebastian
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.1
    • /
    • pp.15-21
    • /
    • 2020
  • PURPOSE. The aim of the current study was to analyze treatment concepts of a cohort of German dentists for planning, fabrication, and maintenance of implant-supported fixed and removable restorations. MATERIALS AND METHODS. A questionnaire including queries about experiences with implant-supported restorations as well as prosthetic and maintenance treatment concepts for supplying patients with fixed and removable implant-supported prosthetic restorations was developed and sent to 350 dental offices registered in the municipal area of Leipzig, Germany. RESULTS. An overall total of 62 returned questionnaires were included in the analyses, which relates to a response rate of 17.7%. Participating dentists were more involved in the prosthetic aspects of implant dentistry rather than surgery, while prosthetic concepts such as backward planning, digital processing, and application of all-ceramic materials were not commonly performed. Simple attachments were preferred over complex retention systems in removable implant-supported restorations. Tooth/implant-supported fixed denture prostheses as well as removable denture prostheses with supporting posterior implants were not regarded as a favorable treatment option. CONCLUSION. Within the limitations of the study, the data indicate that dentists favor simple and conventional treatment approaches in implant prosthetics. Prosthetic aspects in the planning of implant-supported restorations are often neglected. Prosthetic treatment guidelines and aspects should commonly be considered in the planning phase of implant-supported prosthetic restorations, and awareness should be increased in postgraduate education.

Relationship of Foot Type to Callus Location in Healthy Subjects

  • Jung, Do-Young;Kim, Moon-Hwan;Chang, In-Su
    • Physical Therapy Korea
    • /
    • v.13 no.4
    • /
    • pp.64-70
    • /
    • 2006
  • The purpose of this study was to determine whether a relationship existed between foot type and the location of plantar callus in healthy subjects. Twenty-five healthy subjects with plantar callus were recruited for this study. Foot deformities were classified according to the operational definitions as 1) a compensated forefoot varus, 2) an uncompensated forefoot varus or forefoot valgus, or 3) a compensated rearfoot varus. The location of plantar callus was divided into two regions. Fourteen of the 19 feet with compensated forefoot varus and six of the 9 feet showed plantar callus at the second, third or fourth metatarsal head. Five of the 6 feet with uncompensated forefoot varus and twenty of the 16 feet with forefoot valgus showed plantar callus at the first or fifth metatarsal head. A significant relationship was found between foot type and location of callus (p<.01). The results support the hypothesis that certain foot types are associated with characteristic patterns of pressure distribution and callus formation. We believe diabetic patients with insensitive feet and with the types of foot deformity should be fit with foot orthoses and footwears that accommodate their respective deformity in a position as near to the subtalar joint as possible with the goal of preventing plantar ulceration.

  • PDF

A study on maxillofacial prosthesis: systematic considerations (악안면 보철 연구: 체계적 고찰)

  • Hwang, Seong-Sig;Im, Yong-Woon
    • Journal of Technologic Dentistry
    • /
    • v.43 no.4
    • /
    • pp.139-144
    • /
    • 2021
  • Purpose: This study aimed to provide basic data to identify the current status of use of maxillofacial prosthesis across the world and discuss its application and research directions in Korea. Methods: Existing literature (study period, 2010 to 2020) from international studies was collected from PsycINFO, CINAHL, and PubMed, whereas domestic studies were searched using KISS and RISS. Maxillofacial prosthesis was used as the search word. A total of three foreign and two domestic articles were searched, and as a result, a total of 12 documents were selected for analysis. Results: A total of 3,311 studies were searched in this study. Among them, 3,253 articles contained in duplicate inspection and exclusion criteria were removed, and 12 articles were selected by removing literature that did not meet the research criteria through title and green and text reviews. Finally, two researchers selected the final 12 articles through handwritten searches. Eleven of them were case studies, and the remaining one was a descriptive study. Conclusion: This study identified the current status of studies that implemented maxillofacial prosthesis, published from January 2010 to January 2020. Facial prosthetics improve the quality of life of patients by restoring defects that appear on different types of mouth and face and promote both function and aesthetics. Therefore, they can be used to treat various conditions and have a positive impact on the future.

TENSILE STRENGTH OF LASER WELDED-TITANIUM AND GOLD ALLOYS (티타늄과 금합금의 레이저 용접부의 인장강도)

  • Song, Yun-Gwan;Ha, Il-Soo;Song, Kwang-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.200-213
    • /
    • 2000
  • Lasers have given dentistry a new rapid, economic, and accurate technique for metal joining. Although laser welding has been recommended as an accurate technique, there are some limitations with this technique. For example, the two joining surfaces must have a tight-fitting contact, which may be difficult to achieve in some situations. The tensile samples used for this study were made from a custom-made pure titanium and type III gold alloy plates. 27 of 33 specimens were sectioned perpendicular to their long axis with a carborundum disk and water coolant. Six specimens remained and served as the control group. A group of 6 specimens was posed as butt joints in custom parallel positioning device with a feeler gauge at each of three gaps : 0.00, 0.25. and 0.50mm. All specimens were then machined to produce a uniform cross-sectional dimension, none of the specimens was subjected to any subsequent form of heat treatment. Scanning electron microscopy was performed on representative tested specimens at fractured surfaces in both the parent metal and the weld. Vickers hardness was measured at the center of the welds with a micropenetrometer using a force of 300gm for 15 seconds. Measurement was made at approximately $200{\mu}m\;and\;500{\mu}m$ deep from each surface. One-way analysis of variance (ANOVA) and Scheffe's test was calculated to detect differences between groups. The purpose of this study is to compare the strength and properties of the joint achieved at various butt Joint gaps by the laser welding of type III gold alloy and pure titanium tensile specimens in an argon atmosphere. The results of this study were as follows : 1. When indexing and welding pure titanium, there was no decrease in ultimate tensile strength as compared with the unsectioned alloys for indexing gaps of 0.00 to 0.50mm, although with increasing gap size may come increased distortion (p>0.05). 2. When indexing and welding type III gold alloy, there were significant differences in ultimate tensile strength among groups with weld gaps of 0.00mm, 0.25 and 0.50mm, and the control group. Group with butt contact without weld gap demonstrated a significant higher ultimate tensile strength than groups with weld gaps of 0.25 and 0.50mm (p<0.05). 3. When indexing and welding the different metal combination of type III gold alloy and pure titanium, there were significant differences in ultimate tensile strength between groups with weld gaps of 0.00, 0.25, and 0.50mm. However, the mechanical properties of the welded joint would become too brittle to be acceptable clinically (p<0.05). 4. The presence of large pores in the laser welded joint appears to be the most important factor in controlling the tensile strength of the weld in both pure titanium and type III gold alloy.

  • PDF

A study on the Measurement of the Condyle Path Inclination in Relation to Skull Reference Lines by Roentgeno-Cephalometry (Roentgenocephalometry에 의한 한국인 과로와 두부참조선과의 각도계측에 관한 연구)

  • Yun, Young-Yun
    • The Journal of the Korean dental association
    • /
    • v.11 no.2
    • /
    • pp.134-138
    • /
    • 1973
  • The author measured and analyzed the condyle path inclinations of 25 normal Korean adults roentgeno-cephalometrically and following conclusions were obtained. In protrusive movement of mandible, the angle of condyle pation inclination in relation to 1) occlusal plane is 19.86±8.25, 2) Frankfort Horizontal plane is 28.32±8.56, 3) Camper line is 12.22±4.06, 4) Nasion-sella line is 36.80±8.54.

  • PDF

Improving oral rehabilitation through the preservation of the tissues through alveolar preservation

  • Afrashtehfar, Kelvin Ian;Kurtzman, Gregori Michael;Mahesh, Lanka
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.3
    • /
    • pp.174-178
    • /
    • 2012
  • When performing a tooth extraction, imminent collapse of the tissue by resorption and remodeling of the socket is a natural occurrence. The procedure for the preservation of the alveolar ridge has been widely described in the dental literatures and aims to maintain hard and soft tissues in the extraction site for optimal rehabilitation either with conventional fixed or removable prosthetics or implant-supported prosthesis.