• Title/Summary/Keyword: prosthetics

Search Result 208, Processing Time 0.025 seconds

Development of color space conversion algorithm for application of tooth colorimetry app (치아측색용 App 적용을 위한 색공간 변환 알고리즘 개발)

  • Jo, Jae-Hyun;Kim, Seung-Hun;Lee, Sang-Sik;Jeong, Jin-Hyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.1
    • /
    • pp.62-68
    • /
    • 2022
  • Due to medical and economic development, various treatment methods are being studied to restore or maintain beautiful and healthy teeth. In particular, interest in aesthetic treatment procedures such as prosthetic treatment and whitening to restore tooth loss is increasing. One of the important things in the field of prosthetics and esthetic treatment is to determine the correct color of teeth because harmony with natural teeth is an important factor in determining the perfection of esthetic prostheses. This study is about the development of a colorimetry application for tooth colorimetry using a smartphone camera. The colorimetry application UI was designed, the colorimetry algorithm was derived and the application was implemented, and the validity of the application was verified through testing the implemented application.

Component and surface residue observation of barrel finishing media for grinding dental resins (치과용 레진 연마를 위한 바렐 연마재의 성분 분석 및 표면 잔류물 관찰)

  • Jung, An-Na;Park, Yu-Jin;Choi, Sung-Min
    • Journal of Technologic Dentistry
    • /
    • v.43 no.4
    • /
    • pp.145-152
    • /
    • 2021
  • Purpose: This study aimed to produce resin prosthetics using a dental barrel finishing machine. For dental resin grinding, the ingredients of the barrel finishing media were analyzed, and surface residues of the resin were observed. Methods: Two types of barrel finishing media for dental resin grinding were tested. Specimens were made from thermal polymerized, auto polymerized, and photopolymerized resins. Finishing media were analyzed through energy-dispersive X-ray spectroscopy (EDS) component analysis and inductively coupled plasma-optical emission spectrometry (ICP-OES) component analysis. Then, the prepared specimen was barrel finished for 25 minutes using two types of barrel finishing media, and scanning electron microscope was photographed to observe the surface residues. Results: As a result of EDS component analysis, both types of finishing media were analyzed for the components of C, O, Zr and Al elements, and industry media (IM) was further analyzed for the components of Si and Mg elements. In the ICP-OES component analysis, Cd and As, which are harmful elements, were detected in IM, and no harmful elements were detected in manufacturing media (MM). Because of observation of surface residues, no residues were observed in the three types of resin specimens that were barrel finished with two types of finishing media. Conclusion: Surface residue wasn't observed on the specimens polished using two types of finishing media. However, in IM, Cd and As, which are harmful elements, were detected, making it inappropriate for clinical use. In MM, harmful elements were not detected; therefore, clinical use will be possible.

Bio-hybrid dental implants prepared using stem cells with β-TCP-coated titanium and zirconia

  • Safi, Ihab Nabeel;Hussein, Basima Mohammed Ali;Al-Shammari, Ahmed Majeed
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.3
    • /
    • pp.242-257
    • /
    • 2022
  • Purpose: This study investigated periodontal ligament (PDL) restoration in osseointegrated implants using stem cells. Methods: Commercial pure titanium and zirconium oxide (zirconia) were coated with beta-tricalcium phosphate (β-TCP) using a long-pulse Nd:YAG laser (1,064 nm). Isolated bone marrow mesenchymal cells (BMMSCs) from rabbit tibia and femur, isolated PDL stem cells (PDLSCs) from the lower right incisor, and co-cultured BMMSCs and PDLSCs were tested for periostin markers using an immunofluorescent assay. Implants with 3D-engineered tissue were implanted into the lower right central incisors after extraction from rabbits. Forty implants (Ti or zirconia) were subdivided according to the duration of implantation (healing period: 45 or 90 days). Each subgroup (20 implants) was subdivided into 4 groups (without cells, PDLSC sheets, BMMSC sheets, and co-culture cell sheets). All groups underwent histological testing involving haematoxylin and eosin staining and immunohistochemistry, stereoscopic analysis to measure the PDL width, and field emission scanning electron microscopy (FESEM). The natural lower central incisors were used as controls. Results: The BMMSCs co-cultured with PDLSCs generated a well-formed PDL tissue that exhibited positive periostin expression. Histological analysis showed that the implantation of coated (Ti and zirconia) dental implants without a cell sheet resulted in a well-osseointegrated implant at both healing intervals, which was confirmed with FESEM analysis and negative periostin expression. The mesenchymal tissue structured from PDLSCs only or co-cultured (BMMSCs and PDLSCs) could form a natural periodontal tissue with no significant difference between Ti and zirconia implants, consequently forming a biohybrid dental implant. Green fluorescence for periostin was clearly detected around the biohybrid implants after 45 and 90 days. FESEM showed the invasion of PDL-like fibres perpendicular to the cementum of the bio-hybrid implants. Conclusions: β-TCP-coated (Ti and zirconia) implants generated periodontal tissue and formed biohybrid implants when mesenchymal-tissue-layered cell sheets were isolated from PDLSCs alone or co-cultured BMMSCs and PDLSCs.

Adaptive Pressure Sensor with High Sensitivity and Large Bandwidth Based on Gallium Microdroplet-elastomer Composite (갈륨 미세입자 탄성 복합체 기반 고민감도와 광대역폭을 갖는 가변 강성 압력센서)

  • Simok, Lee;Sang-Hyuk, Byun;Steve, Park;Joo Yong, Sim;Jae-Woong, Jeong
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.423-427
    • /
    • 2022
  • A pressure sensor that mimics the sensing ability of human skin has emerged as high-profile technology because it shows remarkable applications in numerous fields such as robotics, human health monitoring, and artificial prosthetics. Whereas recent pressure sensors have achieved high sensitivity similar to that of human skin, they still show limited detection bandwidth. Moreover, once these e-skin are fabricated, their sensitivity and stiffness are fixed; therefore, they can be used for only limited applications. Our study proposes a new adaptive pressure sensor built with uniform gallium microdroplet-elastomer composite. Based on the phase transition of gallium microdroplets, the proposed sensor undergoes mode transformation, enabling it to have a higher sensitivity and wider detection bandwidth compared with those of human skin. In addition, we succeeded in extending a single adaptive pressure sensor to sensor arrays based on its high uniformity, reproducibility, and large-scale manufacturability. Finally, we designed an adaptive e-skin with the sensor array and demonstrated its applications on health monitoring tasks including blood pulse and body weight measurements.

Effects of the Addition of Fibular Repositioning Taping to the Ankle Mobilization with Movement Taping on the Ankle Range of Motion, Balance, and Gait Performance in Patients with Chronic Stroke with Limited Ankle Dorsiflexion (움직임을 동반한 발목 가동 테이핑에 비골 재위치 테이핑의 추가가 발목 배측굴곡 제한을 가진 만성 뇌졸중 환자의 발목 관절가동범위, 균형 및 보행에 미치는 영향)

  • Yang, Seong-hwa;Lee, Ho-jong;Shin, Young-il
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.28 no.2
    • /
    • pp.57-65
    • /
    • 2022
  • Background: This study examined the effects of adding fibular repositioning taping (FRT) to ankle mobilization with movement taping (AMT) on the ankle range of motion (ROM), balance, and gait performance in patients with chronic stroke with limited ankle dorsiflexion. Methods: The participants were randomized into the control (n=15) and AMT+FRT groups (n=15). The control groups applied only non-elastic taping on the affected ankle, and the AMT+FRT groups also applied non-elastic taping to the inferior tibiofibular joint. Both groups performed treadmill walking for 10 minutes. The ankle dorsiflexion passive ROM, balance, gait velocity, and cadence were measured before and after the intervention. Results: Both groups showed a significant difference after the intervention in the dorsiflexion ROM (p<.01), balance (p<.01), and gait performance (p<.01). On the other hand, no significant difference was observed between the two groups (p>.05). Conclusion: AMT improved ankle dorsiflexion passive ROM, balance, gait velocity, and cadence in patients with chronic stroke, but there was no difference between the two groups. Therefore, the addition of FRT to AMT does not influence the ankle dorsiflexion ROM, balance, and gait performance in patients with chronic stroke.

The Effects of Mulligan Mobilization with Movement and McKenize Exercise on Pain, Balance, Range of Motion in Patients with Knee Pain (무릎관절 통증 환자에서 멀리건 관절가동술과 맥켄지 운동이 통증과, 균형, 관절가동범위에 미치는 영향)

  • Lee, Ho-jong;Kim, Jin-young;Shin, Young-il
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.28 no.2
    • /
    • pp.35-44
    • /
    • 2022
  • Background: This study aimed to compare the effects of the Mulligan mobilization with movement and McKenzie exercise after applying conservative physical therapy to patients with knee pain. Methods: Patients were randomly allocatied into two groups: the Mulligan mobilization with movement (10 subjects) and the McKenzie technique (10 subjects). Each group was givenr conservative physical therapy and manual therapy sessions, three times week, for four weeks. The pain intensity was measured using the visual analogue scale (VAS). The cervical range of motion (ROM) was measured with a goniometer. Balance was measured using the modified Berg balance scale (BBS). Results: After four weeks of therapy, VAS (p<.05) decreased significantly, and ROM and balance increased siginficantly in both groups(p<.05). There was a significant improvement in knee extension (p<.05) in the McKenzie group compared to the Mulligan group. No intergroup differences were found with respect to the knee flex, VAS, and BBS (p>.05). Conclusion: The McKenzie exercises are more effective than Mulligan mobilization with movement for improving knee extension. Both interventions have the same effects on pain relief, in increasing knee flexion ROM and improving balance in patients with knee pain.

Anterior Cranial Base Reconstruction in Complex Craniomaxillofacial Trauma: An Algorithmic Approach and Single-Surgeon's Experience

  • Shakir, Sameer;Card, Elizabeth B.;Kimia, Rotem;Greives, Matthew R.;Nguyen, Phuong D.
    • Archives of Plastic Surgery
    • /
    • v.49 no.2
    • /
    • pp.174-183
    • /
    • 2022
  • Management of traumatic skull base fractures and associated complications pose a unique reconstructive challenge. The goals of skull base reconstruction include structural support for the brain and orbit, separation of the central nervous system from the aerodigestive tract, volume to decrease dead space, and restoration of the three-dimensional appearance of the face and cranium with bone and soft tissues. An open bicoronal approach is the most commonly used technique for craniofacial disassembly of the bifrontal region, with evacuation of intracranial hemorrhage and dural repair performed prior to reconstruction. Depending on the defect size and underlying patient and operative factors, reconstruction may involve bony reconstruction using autografts, allografts, or prosthetics in addition to soft tissue reconstruction using vascularized local or distant tissues. The vast majority of traumatic anterior cranial fossa (ACF) injuries resulting in smaller defects of the cranial base itself can be successfully reconstructed using local pedicled pericranial or galeal flaps. Compared with historical nonvascularized ACF reconstructive options, vascularized reconstruction using pericranial and/or galeal flaps has decreased the rate of cerebrospinal fluid (CSF) leak from 25 to 6.5%. We review the existing literature on this uncommon entity and present our case series of n = 6 patients undergoing traumatic reconstruction of the ACF at an urban Level 1 trauma center from 2016 to 2018. There were no postoperative CSF leaks, mucoceles, episodes of meningitis, or deaths during the study follow-up period. In conclusion, use of pericranial, galeal, and free flaps, as indicated, can provide reliable and durable reconstruction of a wide variety of injuries.

Effect of Backrest Height on Biomechanics Variables During VDT (Visual Display Terminal) Work (VDT 작업 시 의자 등받이 높이가 생체역학적 변인에 미치는 영향)

  • Jinjoo Yang;Sukhoon Yoon;Sihyun Ryu
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • Objective: This study identifies the difference among the heights of a chair's backrest (High, Mid, No), the biomechanical changes chair users undergo over time, and the variables that can measure musculoskeletal disorders, eventually providing information on the appropriate type of backrest. Method: Eleven healthy subjects in their 20s and 30s who had no experience with musculoskeletal disorders or surgical operations within the last 6 months participated in this study. Computer typing tasks were randomly designated and performed according to the type of chair backrest, and evaluation was performed for Flexion-Relaxation Ratio (FRR) analysis after the computer typing tasks. This study used eight infrared cameras (sampling rate: 100 Hz) and nine-channel electromyography (sampling rate: 1,000 Hz). ANOVA with repeated measures was conducted to verify the results, with the statistical significance level being α = .05. Results: Although there was no significant difference in craniovertebral angle (CVA), this study showed time and interaction effects depending on the height of the backrest (p<.05). When working without the backrest, the head-spine angle was lower compared to the chairs with backrest, based on the computer work. As for the head angle, the higher the back of the chair was, the less the head flexion and the body angle became, whereas the body flexion became less when there was a backrest. In addition, the body flexion increased over time in all types of backrests (p<.05). The muscle activity of the upper body tended to be high in the high backrest chair. On the other hand, a lower muscle activity was found with a low backrest. Conclusion: These results show that a chair is more ergonomic when the body angle is correctly set without bending and when it is supported by a low backrest. Accordingly, this study determines that the backrest affects shoulder and neck musculoskeletal disorders during typing and that medium-height backrest chairs can help prevent musculoskeletal disorders, contrary to the expectation that high-backrest chairs are preferable.

Toe-in Gait, Associated Complications, and Available Conservative Treatments: A Systematic Review of Literature

  • Mohammad Taghi Karimi
    • Journal of Korean Foot and Ankle Society
    • /
    • v.27 no.1
    • /
    • pp.17-23
    • /
    • 2023
  • Purpose: Toe-in gait is defined as a style of walking in which the foot turns inward. It may be caused by an increase in femoral bone anteversion, tibia torsion, and metatarsus adductus. There are some conservative treatment approaches used to correct this condition. This review aimed to determine the effects of the toe-in gait on joint loading, kinematics, and kinetic parameters while walking. Moreover, it sought to determine the efficiency of various conservative treatments used to correct the condition. Materials and Methods: A literature search was conducted in the following databases: PubMed, Institute for Scientific Information (ISI), Web of Science database, EBSCO, and Embase, using the following keywords in toe, toe-in, toeing, in-toe, pigeon toe, and conservative treatment published between 1950 and 2021. The quality of the studies was evaluated using the Down and Black tool. Results: A total of 13 papers on the impact of toe-in gait on joint contact force, kinematics, kinetic parameters, and conservative approaches to management were found. The quality of the studies varied between a score of 11 and 22. The toe-in gait influences the joint contact forces and kinematics of the joints, especially the hip and pelvis. The effects of conservative treatment on the toe-in gait appear to be controversial. Conclusion: As the toe-in gait influences the joint contact force, it may increase the incidence of degenerative joint diseases. Therefore, treatment is recommended. However, there is no strong evidence on the efficacy of conservative treatments, and there are no recommendations for the use of these treatments in subjects with toe-in gait.

Anti-inflammatory and Anti-nociceptive Effects of Ethyl Acetate Fraction of Lindera glauca (감태나무 에틸아세테이트 분획의 항염증 및 진통 효과)

  • Kim, Jong Soo;Kang, Bo Hye;Park, Seung Ju;Yang, Woo In;Kim, Myung Soo;Lee, Byung Soo;Cha, Dong Seok;Lee, Se Youn;Kwon, Jin;Jeon, Hoon
    • Korean Journal of Pharmacognosy
    • /
    • v.53 no.1
    • /
    • pp.49-56
    • /
    • 2022
  • The present study was designed to evaluate the anti-inflammatory and anti-nociceptive potential of the ethyl acetate fraction of Lindera glauca (ELG). We found that ELG significantly suppressed NO production through decreased enzyme activity and expression of iNOS in the IFN-γ/LPS-activated murine peritoneal macrophages. The treatment of ELG also down-regulated the expression of COX-2. Our western blot data revealed that inhibitory effects of ELG on these pro-inflammatory mediators were attributed to inactivation of NF-κB. In addition, ELG-fed mice showed a marked decrease in paw edema induced by subplantar injection of trypsin, suggesting in vivo anti-inflammatory potential of ELG. We further investigated the anti-nociceptive properties of ELG using thermal and chemical nociception model. We found that ELG has a strong anti-nociceptive activities in both central and peripheral mechanism. An additional combination test with naloxone revealed that opioid receptor was not involved in the ELG-mediated anti-nociception. In conclusion, ELG may possibly be used as valuable anti-inflammatory and anti-nociceptive agent for the treatment of inflammatory diseases and pains.