• Title/Summary/Keyword: prosthesis treatment

Search Result 494, Processing Time 0.026 seconds

Full mouth rehabilitation of a worn dentition using digital guided tooth preparation: a case report (과도한 구치부 마모를 보이는 환자에서 digital guided tooth preparation을 이용한 완전 구강 회복 증례)

  • Kim, Yong-Kyu;Yeo, In-Sung Luke;Yoon, Hyung-In;Lee, Jae-Hyun;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.80-90
    • /
    • 2022
  • With the development of digital dentistry, it is being applied in various ways of dental treatment. This case report presents the definitive prosthesis designed in advance with a re-established vertical dimension and the digital technology, which determined the amount of tooth preparation, in order to preserve as much tooth structure as possible in a patient with pathological wear of the posterior teeth and loss of vertical dimension. For accurate tooth preparation, the guides of the occlusal and axial surfaces were digitally and additively manufactured. Then, aesthetics and anterior guidance were established at the provisional stage. The information of the provisional restoration was delivered to the definitive stage by double scanning. The digital technology, including the virtual planning and the guided tooth removal, produced the definitive restorations satisfactory to both the patient and clinician.

Full mouth rehabilitation of the patient with severely worn dentition and limited vertical dimension (심한 치아 마모와 수복공간 부족을 보이는 환자에서의 완전 구강회복 증례)

  • Yang, Min-Seong;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Park, Ji-Man;Yi, Yu-Seung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.91-99
    • /
    • 2022
  • Severely worn dentition causes various complications such as loss of tooth structure, discoloration, pulp complications and loss of function and aesthetics. In this case, the patient showed particularly severe attrition in the anterior teeth and lack of space for restoration. The amount of vertical dimension was determined based on the diagnostic wax up, and the patient's adaptation was evaluated by using a removable occlusal splint for 6 weeks. Thereafter, the coordination of the muscular nervous system, aesthetics, temporomandibular joint were re-evaluated for 3 months by restoring the fixed provisional restoration. Through the above treatment process, the final restoration was completed with full mouth fixed prosthesis using monolithic zirconia, and functionally and aesthetically stable results were obtained.

Complete mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and dental CAD-CAM (완전 무치악 환자에서 임시 의치와 치과용 CAD-CAM을 활용한 전악 고정성 임플란트 회복 증례)

  • Jeon, Sol;Yoon, Hyung-In;Lee, Jae-Hyun;Yeo, In-Sung Luke;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.100-109
    • /
    • 2022
  • Installation of dental implants at optimal angles and positions is critical in long-term stable implant-supported restorations. Surgery and prosthodontic procedures should be performed accurately as the treatment is planned. In this clinical case, Computer aided design and manufacturing technology was used not only to establish a precise surgical plan, but also to fabricate both provisional and definitive fixed prostheses. A surgical guide was designed to install the implants at proper positions for the definitive prostheses. The patient's esthetic information, which was necessary for the new provisional and definitive fixed prostheses, was obtained from the existing temporary dentures. Finally, the complete mouth fixed implant-supported rehabilitation using monolithic zirconia provided the patient with functionally and esthetically satisfactory prostheses.

Effect of repair methods and materials on the flexural strength of 3D-printed denture base resin

  • Viotto, Hamile Emanuella do Carmo;Silva, Marcela Dantas Dias;Nunes, Thais Soares Bezerra Santos;Coelho, Sabrina Romao Goncalves;Pero, Ana Carolina
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.5
    • /
    • pp.305-314
    • /
    • 2022
  • PURPOSE. The aim of this study was to evaluate the flexural strength of a 3D-printed denture base resin (Cosmos Denture), after different immediate repair techniques with surface treatments and thermocycling. MATERIALS AND METHODS. Rectangular 3D-printed denture base resin (Cosmos Denture) specimens (N = 130) were thermocycled (5,000 cycles, 5℃ and 55℃) before and after the different repair techniques (n = 10 per group) using an autopolymerized acrylic resin (Jet, J) or a hard relining resin (Soft Confort, SC), and different surface treatments: Jet resin monomer for 180 s (MMA), blasting with aluminum oxide (JAT) or erbium: yttrium-aluminum-garnet laser (L). The control group were intact specimens. A three-point flexural strength test was performed, and data (MPa) were analyzed by ANOVA and Games-Howell post hoc test (α = 0.05). Each failure was observed and classified through stereomicroscope images and the surface treatments were viewed by scanning electron microscope (SEM). RESULTS. Control group showed the highest mean of flexural strength, statistically different from the other groups (P < .001), followed by MMA+J group. The groups with L treatment were statistically similar to the MMA groups (P > .05). The JAT+J group was better than the SC and JAT+SC groups (P < .05), but similar to the other groups (P > .05). Adhesive failures were most observed in JAT groups, especially when repaired with SC. The SEM images showed surface changes for all treatments, except JAT alone. CONCLUSION. Denture bases fabricated with 3D-printed resin should be preferably repaired with MMA+J. SC and JAT+SC showed the worst results. Blasting impaired the adhesion of the SC resin.

Decoronation and implant restoration of ankylosed tooth resulted from anterior avulsion: A case report (전치부 탈구로 인한 유착치의 치관절제술 및 임플란트 수복 증례)

  • Hyeon Kim;Eunsu Lee;Woohyung Jang;Hyun-Pil Lim;Sangwon Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.26-32
    • /
    • 2023
  • Dental trauma is common in active children and adolescents. Among them, in the case of ankylosis due to avulsion, diagnosis through clinical examination is important, and the treatment is important for esthetic prosthetic restoration after adulthood. This case is a case of esthetic prosthetic restoration of maxillary anterior teeth through decoronation and implant. After that, space was maintained for prosthetic restoration using a decoronated crown. After becoming an adult, precise implant placement and esthetic prosthetic restoration were possible using guide surgery. For soft tissue support, the temporary crown were replaced by changing the contours of the temporary crown, and the final esthetic prosthesis was fabricated by digital wax-up.

Long-term effect of implant-abutment connection type on marginal bone loss and survival of dental implants

  • Young-Min Kim;Jong-Bin Lee;Heung-Sik Um;Beom-Seok Chang;Jae-Kwan Lee
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.6
    • /
    • pp.496-508
    • /
    • 2022
  • Purpose: This study aimed to compare the long-term survival rate and peri-implant marginal bone loss between different types of dental implant-abutment connections. Methods: Implants with external or internal abutment connections, which were fitted at Gangneung-Wonju National University Dental Hospital from November 2011 to December 2015 and followed up for >5 years, were retrospectively investigated. Cumulative survival rates were evaluated for >5 years, and peri-implant marginal bone loss was evaluated at 1- and 5-year follow-up examinations after functional loading. Results: The 8-year cumulative survival rates were 93.3% and 90.7% in the external and internal connection types, respectively (P=0.353). The mean values of marginal bone loss were 1.23 mm (external) and 0.72 mm (internal) (P<0.001) after 1 year of loading, and 1.20 mm and 1.00 mm for external and internal abutment connections, respectively (P=0.137) after 5 years. Implant length (longer, P=0.018), smoking status (heavy, P=0.001), and prosthetic type (bridge, P=0.004) were associated with significantly greater marginal bone loss, and the use of screw-cement-retained prosthesis was significantly associated (P=0.027) with less marginal bone loss. Conclusions: There was no significant difference in the cumulative survival rate between implants with external and internal abutment connections. After 1 year of loading, marginal bone loss was greater around the implants with an external abutment connection. However, no significant difference between the external and internal connection groups was found after 5 years. Both types of abutment connections are viable treatment options for the reconstruction of partially edentulous ridges.

Tilted implants for implant-supported fixed hybrid prostheses: retrospective review

  • Woo-Hyun Seok;Pil-Young Yun;Na-Hee Chang;Young-Kyun Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.49 no.5
    • /
    • pp.278-286
    • /
    • 2023
  • Objectives: This review assessed the performance of implant-supported fixed hybrid prostheses in 21 patients who received a total of 137 implants between 2003 and 2010. The implants were evaluated for marginal bone resorption, complications, success rate, and survival rate based on their vertical angularity, type of bone graft, and measured implant stability. Materials and Methods: One-way ANOVA and chi-square tests were used to analyze the relationships among long-term evaluation factors and these variables. The mean initial bone resorption in the implant group with a vertical angle of more than 20° was 0.33 mm and mean final bone resorption was 0.76 mm. In contrast, the mean initial bone resorption in the implant group with a vertical angle of less than 10° was 1.19 mm and mean final bone resorption was 2.17 mm. Results: The results showed that mean bone resorption decreased with an increase in the vertical placement angle of the implants used in fixed hybrid prostheses, as well as in the group without additional bone grafts and those with high implant stability. The success rate of implants placed after bone grafting was found to be higher than those placed simultaneously. Conclusion: These results suggest that implant-supported fixed hybrid prostheses may be an effective treatment option for edentulous patients, and intentionally placing implants with high angularity may improve outcomes.

Primary Arthroplasty for Unstable and Failed Intertrochanteric Fractures: Role of Multi-Planar Trochanteric Wiring Technique

  • Javahir A. Pachore;Vikram Indrajit Shah;Sachin Upadhyay;Shrikunj Babulal Patel
    • Hip & pelvis
    • /
    • v.35 no.2
    • /
    • pp.108-121
    • /
    • 2023
  • Purpose: The primary objective of the current study is to demonstrate the trochanteric wiring technique. A secondary objective is to evaluate the clinico-radiological outcomes of use of the wiring technique during primary arthroplasty for treatment of unstable and failed intertrochanteric fractures. Materials and Methods: A prospective study including follow-up of 127 patients with unstable and failed intertrochanteric fractures who underwent primary hip arthroplasty using novel multi-planar trochanteric wiring was conducted. The average follow-up period was 17.8±4.7 months. Clinical assessment was performed using the Harris hip score (HHS). Radiographic evaluation was performed for assessment of union of the trochanter and any mechanical failure. P<0.05 was considered statistically significant. Results: At the latest follow-up, the mean HHS showed significant improvement from 79.9±1.8 (at three months) to 91.6±5.1 (P<0.05). In addition, no significant difference in the HHS was observed between male and female patients (P=0.29) and between fresh and failed intertrochanteric fractures (P=0.08). Union was achieved in all cases of fractured trochanter, except one. Wire breakage was observed in three patients. There were five cases of limb length discrepancy, three cases of lurch, and three cases of wire-related bursitis. There were no cases of dislocation or infection. Radiographs showed stable prosthesis in situ with no evidence of subsidence. Conclusion: Use of the proposed wiring technique was helpful in restoring the abductor level arm and multi-planar stability, which enabled better rehabilitation and resulted in excellent clinical and radiological outcomes with minimal risk of mechanical failure.

Anatomic total shoulder arthroplasty with a nonspherical humeral head and inlay glenoid: 90-day complication profile in the inpatient versus outpatient setting

  • Andrew D. Posner;Michael C. Kuna;Jeremy D. Carroll;Eric M. Perloff;Matthew J. Anderson;Ian D. Hutchinson;Joseph P. Zimmerman
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.4
    • /
    • pp.380-389
    • /
    • 2023
  • Background: Total shoulder arthroplasty (TSA) with a nonspherical humeral head component and inlay glenoid is a successful bone-preserving treatment for glenohumeral arthritis. This study aimed to describe the 90-day complication profile of TSA with this prosthesis and compare major and minor complication and readmission rates between inpatient- and outpatient-procedure patients. Methods: A retrospective review was performed of a consecutive cohort of patients undergoing TSA with a nonspherical humeral head and inlay glenoid in the inpatient and outpatient settings by a single surgeon between 2017 and 2022. Age, sex, body mass index, American Society of Anesthesiologists (ASA) score, Charlson Comorbidity Index (CCI), and 90-day complication and readmission rates were compared between inpatient and outpatient groups. Results: One hundred eighteen TSAs in 111 patients were identified. Mean age was 64.9 years (range, 39-90) and 65% of patients were male. Ninety-four (80%) and 24 (20%) patients underwent outpatient and inpatient procedures, respectively. Four complications (3.4%) were recorded: axillary nerve stretch injury, isolated ipsilateral arm deep venous thrombosis (DVT), ipsilateral arm DVT with pulmonary embolism requiring readmission, and gastrointestinal bleed requiring readmission. There were no reoperations or other complications. Outpatients were younger with lower ASA and CCI scores than inpatients; however, there was no difference in complications (1/24 vs. 3/94, P=1.00) or readmissions (1/24 vs. 1/94, P=0.37) between these two groups. Conclusions: TSA with a nonspherical humeral head and inlay glenoid can be performed safely in both inpatient and outpatient settings. Rates of early complications and readmissions were low with no difference according to surgical setting. Level of evidence: IV.

A Bicentric Propensity Matched Analysis of 158 Patients Comparing Porcine Versus Bovine Stented Bioprosthetic Valves in Pulmonary Position

  • Bunty Ramchandani;Raul Sanchez;Juvenal Rey;Luz Polo;Alvaro Gonzalez;Maria-Jesus Lamas;Tomasa Centella;Jesus Diez;Angel Aroca
    • Korean Circulation Journal
    • /
    • v.52 no.8
    • /
    • pp.623-631
    • /
    • 2022
  • Background and Objectives: Pulmonary valve replacement (PVR) is the most common operation in adults with congenital heart disease (CHD). There is controversy regarding the best bioprosthesis. We compare the performance of stented bioprosthetic valves (the Mosaic [MedtronicTM] porcine pericardial against Carpentier Perimount Magna Ease [EdwardsTM] bovine) in pulmonary position in patients with CHD. Methods: Between January 1999 and December 2019, all the PVRs were identified from hospital databases in 2 congenital heart centres in Spain. Valve performance was evaluated using clinical and echocardiographic criteria. Propensity score matching was used to balance the 2 treatment groups. Results: Three hundred nineteen patients were retrospectively identified. After statistical adjustment, 79 propensity-matched pairs were available for comparison Freedom from reintervention for the porcine cohort was 98.3%, 96.1%, and 91.9% at 3, 5, and 10 years and 100%, 98%, and 90.8% for the bovine cohort (p=0.88). Freedom from structural valve degeneration (SVD) for the porcine cohort was 96.9%, 92.8% and 88.7% at 3, 5, and 10 years and 100%, 98%, and 79.1% for the bovine cohort (p=0.38). Bovine prosthesis was associated with a reintervention hazard ratio (HR), 1.12; 95% confidence intervals (CIs), 0.24-5.26; p=0.89 and SVD HR, 1.69 (0.52-5.58); p=0.38. In the first 5 years, there was no difference in outcomes. After 5 years, the recipients of the bovine bioprosthesis were at higher risk for SVD (reintervention HR, 2.08 [0.27-16.0]; p=0.49; SVD HR, 6.99 [1.23-39.8]; p=0.03). Conclusions: Both bioprosthesis have similar outcomes up to 5 years, afterwards, porcine bioprosthesis seem to have less SVD.