• 제목/요약/키워드: prosthesis treatment

검색결과 494건 처리시간 0.027초

양측성으로 하악골에 순차적으로 발생한 방사선골괴사증: 증례보고 (SERIAL OSTEORADIONECROSIS ON BOTH SIDES OF MANDIBLE: A CASE REPORT)

  • 김해린;윤규호;박관수;정정권;배정호;권준;박군찬;신재명;백지선
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제32권3호
    • /
    • pp.265-269
    • /
    • 2010
  • Radiation therapy for malignancy of head and neck leads to secondary effects, such as mucositis, xerostomia, dental caries and osteoradionecrosis. Osteoradionecrosis is a delayed complication which causes chronic pain, infection and constant deformity after necrosis. It occurs spontaneously or after primary oncologic surgery, dental extraction or by trauma of prosthesis. To reduce the incidence of osteoradionecrosis, appropriate antibiotic usage, atraumic procedure, tension-free primary suture and hyperbaric oxygen therapy are essential. This case is about a 74 years old woman who was treated for osteoradionecrosis after extraction of right lower molar at year 2006. She had received radiation therapy for angiosarcoma on tongue at year 2004. At year 2008 the patient came to our hospital for extraction of the opposite premolar but despite careful treatment, osteoradionecrosis occurred again. She was successfully treated by surgical procedure so we report this case.

Gold Electroforming System을 이용한 하악 임플란트 지지 텔레스코프 피개의치 (Mandibular Implant-Supported Telescopic Overdenture using Gold Electroforming System : A Case Report)

  • 최지하;김승균;유병일;안승근;박주미;송광엽;박찬운
    • 구강회복응용과학지
    • /
    • 제24권2호
    • /
    • pp.193-201
    • /
    • 2008
  • 하악 완전 무치악 환자의 보철수복에 있어 임플란트 식립 후 피개의치의 제작은 첫 번째 치료 옵션으로 고려되어질 수 있다. 임플란트 지지 텔레스코프 피개의치를 제작하는 경우 인공치 및 유지 장치의 배열을 위한 악간 공간이 필요하다. 임플란트 상부 보철물의 passive한 fit은 보철물의 기계적 실패를 막는 중요한 요소이다. Gold electroforming system을 이용하여 제작한 telescopic attachment는 우수한 마진 적합도 및 passive한 fit을 보이며 얇은 코핑 두께로 인하여 좁은 악간 공간에서도 사용이 가능한 장점이 있다. 본 증례에서는 4개의 임플란트 식립 후 Gold electroforming system을 이용하여 telescopic overdenture를 제작하여 기능 및 심미적으로 좋은 결과를 나타내었다.

Skeletal Anchorage System의 식립을 위한 한국인 악골의 피질골 두께에 대한 연구 (STUDY OF MAXILLARY CORTICAL BONE THICKNESS FOR SKELETAL ANCHORAGE SYSTEM IN KOREAN)

  • 김지혁;주재용;박영욱;차봉근;김성민
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제28권4호
    • /
    • pp.249-255
    • /
    • 2002
  • Recently, Skeletal Anchorage System (SAS) has been focused clinically with the view point that it could provide the absolute intraoral anchorage. First, it began to be used for the patient of orthognathic surgery who had difficulty in taking intermaxillary fixation due to multiple loss of teeth. And then, its uses have been extended to many cases, the control of bone segments after orthognathic surgery, stable anchorage in orthodontic treatment, and anchorage for temporary prosthesis and so on. SAS has been developed as dental implants technique has been developed and also called in several names; mini-screw anchorage, micro-screw anchorage, mini-implant anchorage, micro-implant anchorage (MIA), and orthosystem implant etc. Now many clinicians use SAS, but the anatomical knowledges for the installed depth of intraosseous screws are totally dependent on general experiences. So we try to study for the cortical thickness of maxilla and mandible in Korean adults without any pathologic conditions with the use of Computed Tomography at the representative sites for the screw installation.

총의치 난증례에 대한 접근법: 진단부터 최종의치까지 (Approach to complicated fully edentulous case: from the diagnosis to the definitive denture)

  • 오진아;이현민;백장현;노관태;권긍록;배아란
    • 대한치과보철학회지
    • /
    • 제53권3호
    • /
    • pp.250-255
    • /
    • 2015
  • 심한 잔존치조제의 흡수와 의치지지조직의 손상을 동반한 총의치 난증례는 정확한 진단과 체계적인 치료계획 수립을 통해 보철물의 유지, 안정, 지지를 증진시켜야 한다. Provisional restoration은 총의치의 안정성을 다각도로 평가하고 환자와 치과의사의 피드백을 가능하게 하는 유용한 도구로서 사용될 수 있다. 본 증례에서는 진단용의치를 통해 인상면, 연마면, 교합면을 평가하여 의치의 안정성을 증대시키고 환자의 심미적 요구를 반영하여 최종의치로 이행하였으며 임상적으로 기능과 심미적인 측면에 있어서 만족할 만한 결과를 얻었기에 이를 보고하고자 한다.

Three dimensional finite element analysis of the stress distribution around the mandibular posterior implant during non-working movement according to the amount of cantilever

  • Park, Ji-Man;Kim, Hyun-Joo;Park, Eun-Jin;Kim, Myung-Rae;Kim, Sun-Jong
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권5호
    • /
    • pp.361-371
    • /
    • 2014
  • PURPOSE. In case of large horizontal discrepancy of alveolar ridge due to severe resorption, cantilevered crown is usually an unavoidable treatment modality. The purpose of this study was to evaluate the clinical criteria for the placement of the aforementioned implant crown. MATERIALS AND METHODS. The mandible model with 2 mm thick cortical bone and cancellous bone was fabricated from CT cross-section image. An external connection type implant was installed and cantilevered crowns with increasing offset of 3, 4, 5, 6, and 7 mm were connected. Vertical load and $30^{\circ}$ oblique load of 300 N was applied and stress around bone and implant component was analyzed. A total of 14 cases were modeled and finite element analysis was performed using COSMOS Works (Solid works Inc, USA). RESULTS. As for the location of the vertical load, the maximum stress generated on the lingual side of the implant became larger according to the increase of offset distance. When the oblique load was applied at $30^{\circ}$, the maximum stress was generated on the buccal side and its magnitude gradually decreased as the distance of the offset load increased to 5 mm. After that point, the magnitude of implant component's stress increased gradually. CONCLUSION. The results of this study suggest that for the patient with atrophied alveolar ridge following the loss of molar teeth, von-Mises stress on implant components was the lowest under the $30^{\circ}$ oblique load at the 5 mm offset point. Further studies for the various crown height and numbers of occusal points are needed to generalize the conclusion of present study.

Standardizing the evaluation criteria on treatment outcomes of mandibular implant overdentures: a systematic review

  • Kim, Ha-Young;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권5호
    • /
    • pp.325-332
    • /
    • 2014
  • PURPOSE. The aim of this review was to analyze the evaluation criteria on mandibular implant overdentures through a systematic review and suggest standardized evaluation criteria. MATERIALS AND METHODS. A systematic literature search was conducted by PubMed search strategy and hand-searching of relevant journals from included studies considering inclusion and exclusion criteria. Randomized clinical trials (RCT) and clinical trial studies comparing attachment systems on mandibular implant overdentures until December, 2011 were selected. Twenty nine studies were finally selected and the data about evaluation methods were collected. RESULTS. Evaluation criteria could be classified into 4 groups (implant survival, peri-implant tissue evaluation, prosthetic evaluation, and patient satisfaction). Among 29 studies, 21 studies presented implant survival rate, while any studies reporting implant failure did not present cumulative implant survival rate. Seventeen studies evaluating peri-implant tissue status presented following items as evaluation criteria; marginal bone level (14), plaque Index (13), probing depth (8), bleeding index (8), attachment gingiva level (8), gingival index (6), amount of keratinized gingiva (1). Eighteen studies evaluating prosthetic maintenance and complication also presented following items as evaluation criteria; loose matrix (17), female detachment (15), denture fracture (15), denture relining (14), abutment fracture (14), abutment screw loosening (11), and occlusal adjustment (9). Atypical questionnaire (9), Visual analog scales (VAS) (4), and Oral Health Impact Profile (OHIP) (1) were used as the format of criteria to evaluate patients satisfaction in 14 studies. CONCLUSION. For evaluation of implant overdenture, it is necessary to include cumulative survival rate for implant evaluation. It is suggested that peri-implant tissue evaluation criteria include marginal bone level, plaque index, bleeding index, probing depth, and attached gingiva level. It is also suggested that prosthetic evaluation criteria include loose matrix, female detachment, denture fracture, denture relining, abutment fracture, abutment screw loosening, and occlusal adjustment. Finally standardized criteria like OHIP-EDENT or VAS are required for patient satisfaction.

엇갈린 교합 환자의 임플란트 지지 고정성 보철물과 Kennedy class IV 가철성 국소의치를 이용한 수복 증례 (Rehabilitation of a patient with crossed occlusion using mandibular implant-supported fixed and maxillary Kennedy class IV removable dental prostheses: A case report)

  • 강석형;한중석;김성훈;윤형인;여인성
    • 대한치과의사협회지
    • /
    • 제55권12호
    • /
    • pp.842-849
    • /
    • 2017
  • The term, 'crossed occlusion' implies clinical situation in which the residual teeth in one arch have no contact with those in the antagonistic arch, resulting in the collapse of occlusal vertical dimension. The treatment goal of this pathologic condition is restoration of the collapsed vertical dimension and stabilization of abnormal mandibular position. Previously, konus removable prostheses or tooth supported overdentures were suggested to solve crossed occlusion. Nowadays, dental implants have been used for definitive support to solve this problem. In this case report, a 65 years old female patient had a crossed occlusion, in which the maxillary posterior residual teeth and mandibular anterior residual teeth cross. Interim removable and fixed dental prostheses were used to confirm the proper vertical and horizontal jaw relation. After that, the mandibular posterior edentulous region was restored with implant-supported fixed dental prostheses. Computer tomography guided implant surgery was performed according to the concept of the restoration-driven implant placement. The maxillary anterior edentulous region was restored with Kennedy class IV removable prosthesis, considering the patient's economic status. The patient's jaw position and prostheses have been well maintained at the follow-up after 6 months of definitive restoration. The antero-posterior crossed occlusion problems appeared to be effectively solved with the combination of removable in one arch and implant-supported fixed prostheses in the other.

  • PDF

Implant-supported overdentures with different bar designs: A retrospective evaluation after 5-19 years of clinical function

  • Rinke, Sven;Rasing, Hajo;Gersdorff, Nikolaus;Buergers, Ralf;Roediger, Matthias
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권4호
    • /
    • pp.338-342
    • /
    • 2015
  • PURPOSE. This retrospective study evaluated the outcome of implant-retained overdentures (IODs) after 5-19 years of clinical function. MATERIALS AND METHODS. A retrospective analysis of patient files was performed referring to 27 patients who received 36 IODs with 3 different bar designs (group A=prefabricated round bars, n=7; group B=one-piece anterior milled bars, n=20; and group C=two bilaterally placed milled bars, n=9) in the mandible (n=24) and/or in the maxilla (n=12). The analysis focused on the survival and success rates (according to Kaplan-Meier) of the implants and prostheses. Technical complication rates for each type of restoration were analyzed and compared via one-way ANOVA and the Chi-squared test. The prevalence of peri-implantitis (radiographic bone loss ${\geq}3.5mm$) was evaluated by digital analysis of panoramic radiographs taken postoperative (baseline) and after 5-19 years of clinical function (follow-up). RESULTS. The mean observational time was 7.3 years. The survival rates of the prostheses and implants were 100% and 97.7%, respectively. Technical complications occurred more frequently in group A (mean: 3.5 during observational time) than in the other two groups (B: 0.8; C: 1.0). However, this difference was not statistically significant (P=0.58). Peri-implantitis was diagnosed for 12.4% of the implants in 37% of the patients. CONCLUSION. Bar-retained IODs are an adequate treatment option for edentulous jaws. These restorations may exhibit high implant/prosthesis survival rates (>97%), and a limited incidence of technical complications after a mean observational period of >7 years. Nevertheless, peri-implantitis was identified as a frequent and serious biological complication for this type of reconstruction.

임플란트 보철물과 인접치 사이의 식편압입에 관한 임상적 연구 (Clinical study on the food impaction between implant prostheses and adjacent teeth)

  • 신동욱;이진한;김세연;동진근
    • 대한치과보철학회지
    • /
    • 제52권1호
    • /
    • pp.27-33
    • /
    • 2014
  • 연구 목적: 본 연구는 임플란트 보철물과 인접치 사이의 식편압입을 호소하는 환자를 대상으로 각종 임상 자료를 분석하여 식편압입의 임상적 발현 양상을 알아보고자 하였다. 연구 재료 및 방법: 식편압입을 주소로 내원한 보철물 장착이 완료된 임플란트 환자 51명을 대상으로 설문조사와 구강검사를 시행하고 방사선 사진과 모형을 채득하여 식편압입과 관련이 있는 요소를 분석한 결과 다음과 같은 결과를 얻었다. 결과: 1. 식편압입은 하악(39.2%)보다 상악(60.7%)에서 많이 나타났다. 2. 식편압입은 자연치아가 임플란트 보철물의 원심 부위(13.7%)에 있는 경우보다 근심 부위(86.2%)에 있는 경우에 많이 나타났다. 3. 식편압입이 나타난 임플란트 보철물과 그 인접치 사이의 접촉점은 긴밀하지 않은 경우(94.2%)가 대부분이었다. 결론: 임플란트 보철물과 인접치 사이에 식편압입이 일어나지 않기 위해서는 임플란트 보철물과 인접치아가 적절한 긴밀도를 가지고 있어야 하겠다.

인대 불안정성이 동반된 말기 족근 관절염 환자의 자가 인대 재건술과 인공관절 치환술의 치료 결과 (End Stage Ankle Arthritis with Ankle Instability Patients Treatment Results Using Autograft Ligament Reconstruction with Total Ankle Arthroplasty)

  • 최재혁;김정렬;김동현;정우철;윤정로;여의동;이경태
    • 대한족부족관절학회지
    • /
    • 제14권1호
    • /
    • pp.47-52
    • /
    • 2010
  • Purpose: We report the clinical and radiographic result of ligament reconstruction using plantaris and total ankle replacement in end-stage ankle arthritis with ankle instability. Materials and Methods: The study is based on the 9 cases among total 48 patients of end-stage ankle arthritis that were treated with total ankle prosthesis and ligament reconstruction from 2007 to 2009 at least 12 months follow-up. We evaluated the VAS (Visual analogue scale) pain score, AOFAS (American orthopedic foot and ankle society) score and radiographic measurements. Results: Average age was 59.4 years (53~67 years) old. VAS pain score improved from preoperative average $8.2{\pm}0.9$ (range, 7~10) to $2.7{\pm}1.7$ (range, 0~6) and the AOFAS score improved from $46.4{\pm}14.6$ points (range, 23~69) to $80.1{\pm}9.3$ points (range, 65~95) at final follow-up. Anterior draw test improved $15.2{\pm}3.4$ mm (range, 12~23 mm) to $8.8{\pm}2.6$ mm (range, 6~13mm), varus stress test improved from $13.9{\pm}4.6^{\circ}$ (range, $10-18^{\circ}$) to $6.2{\pm}4.7^{\circ}$ (range, $2-18^{\circ}$) at final follow up. Conclusion: Plantaris ligament reconstruction is good option as part of the management of ankle instability with end-stage ankle arthritis. We achieved good clinical and radiographic results.