• Title/Summary/Keyword: prosthesis arm

Search Result 25, Processing Time 0.035 seconds

A study on bio-signal process for prosthesis arm control (인공의수의 능동 제어를 위한 생체 신호 처리에 관한 연구)

  • Ahn, Young-Myung;Yoo, Jae-Myung
    • 전자공학회논문지 IE
    • /
    • v.43 no.4
    • /
    • pp.28-36
    • /
    • 2006
  • In this paper, an algorithm to classify the 4 motions of arm and a control system to position control the prosthesis are studied. To classify the 4 motions, we use flex sensors which is electrical resistance type sensor that can measure warp of muscle. The flex sensors are attached to the biceps brchii muscle and coracobrachialis muscle and the sensor signals are passed the sensing system. 4 motion of the forearm - flexion and extension, the pronation and supination are classified from this. Also position of forearm is measured from the classified signals. Finally, A two D.O.F prosthesis arm with RC servo-motor is designed to verify the validity of the algorithm. At this time, fuzzy controller is used to reduce the position error by rotary inertia and noise. From the experiment, the position error had occurred within about 5 degree.

Prosthetic arm control using muscle signal (생체 근육 신호를 이용한 보철용 팔의 제어)

  • Yoo J.M.;Kim Y.T.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1944-1947
    • /
    • 2005
  • In this paper, the control of a prosthetic arm using the flex sensor signal is described. The flex sensors are attached to the biceps and triceps brchii muscle. The signals are passed a differential amplifier and noise filter. And then the signals are converted to digital data by PCI 6036E ADC. From the data, position and velocity of arm joint are obtained. Also motion of the forearm - flexion and extension, the pronation and supination are abstracted from the data by proposed algorithm. A two D.O.F arm with RC servo-motor is designed for experiment. The arm length is 200 mm, weight is 4.5 N. The rotation angle of elbow joint is $120^{\circ}$. Also the rotation angle of the wrist is $180^{\circ}$. Through the experiment, we verified the possibility of the prosthetic arm control using the flex sensor signal. We will try to improve the control accuracy of the prosthetic arm continuously.

  • PDF

Successful Correction of Atypical Coarctation of the Aorta -Report of 4 Cases- (선천성 대동맥 축착증 4례)

  • 권중혁
    • Journal of Chest Surgery
    • /
    • v.12 no.3
    • /
    • pp.174-182
    • /
    • 1979
  • This is a report on four cases of successful surgical correction of coarctation of the aorta [COA] in Department of the Thoracic & Cardiovascular Surgery, Hanyang University Hospital. The first case was a postductal type of coarctation of the aorta associated with Patent ductus arteriosus [PDA], Persistent left superior vena cava [LSVC] and richly developed collateral circulation. Blood pressure was measured to be hypertensive at the arm, but hypotensive at the legs. The coarctation of the aorta was corrected with following procedure: Partial resection of the aortic wall with diaphragmatic structure lust above and below the coarctating line of the aorta, and then the defect of the aortic wall was closed by lateral aortographic suture. PDA was closed by ligation procedure. The second case a preductal type of coarctation of the aorta associated with PDA, LSVC, ventricular septal defect [VSD] and poorly developed collateral circulation. Normal blood pressure was measured at the arm, but hypotension was observed at the legs. Correction of coarctation of the aorta was performed under the establishment of tube bypass because of poor collateral circulation. After resection of coarctating short segment, end to end anastomosis was performed without any tension. PDA was closed by division procedure. Simple suture closure of VSD was performed by open heart surgery two weeks after correction of COA. The third case was a long segment COA without any other anomaly. Blood pressure was measured to be hypertensive at the arm, but hypotensive at the legs. Vascular prosthesis was performed using Teflon graft tube after resecting coarctating long segment [6.5 cm] of the aorta. The fourth case was a long segment COA associated with aortic insufficiency and richly developed collateral circulation. Normal blood pressure was measured at the arm, but hypotension was observed at the legs. Vascular prosthesis was performed using Teflon graft tube after resecting coarctating long segment [6.0 cm] of the aorta. Both blood pressure and peripheral pulse on the arm and the legs returned to normal postoperatively in all patients.

  • PDF

The effect of early arm exercise on drainage volume after total mastectomy and tissue expander insertion in breast cancer patients: a prospective study

  • Joo, Oh Young;Moon, Seung Jin;Lee, Dong Won;Lew, Dae Hyun;Lee, Won Jai;Song, Seung Yong
    • Archives of Plastic Surgery
    • /
    • v.48 no.6
    • /
    • pp.583-589
    • /
    • 2021
  • Background In prosthesis-based breast reconstruction patients, the drain tends to be kept in place longer than in patients who undergo only mastectomy. Postoperative arm exercise also increases the drainage volume. However, to preserve shoulder function, early exercise is recommended. In this study, we investigated the effect of early exercise on the total drainage volume and drain duration in these patients. Methods We designed a prospective randomized trial involving 56 patients who underwent immediate breast reconstruction following mastectomy using tissue expanders. In each group, the patients were randomized either to perform early arm exercises using specific shoulder movement guidelines 2 days after surgery or to restrict arm movement above the shoulder height until drain removal. The drain duration and the total amount of drainage were the primary endpoints. Results There were no significant differences in age, height, weight, body mass index, or mastectomy specimen weight between the two groups. The total amount of drainage was 1,497 mL in the early exercise group and 1,336 mL in the exercise restriction group. The duration until complete removal of the drains was 19.71 days in the early exercise group and 17.11 days in the exercise restriction group. Conclusions Exercise restriction after breast reconstruction did not lead to a significant difference in the drainage volume or the average time until drain removal. Thus, early exercise is recommended for improved shoulder mobility postoperatively. More long-term studies are needed to determine the effect of early exercise on shoulder mobility in prosthesis-based breast reconstruction patients.

Control of an Artificial Arm using Flex Sensor Signal (굽힘 센서신호를 이용한 인공의수의 제어)

  • Yoo, Jae-Myung;Kim, Young-Tark
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.6
    • /
    • pp.738-743
    • /
    • 2007
  • In this paper, a muscle motion sensing system and an artificial arm control system are studied. The artificial arm is for the people who lost one's forearm. The muscle motion sensing system detect the intention of motion from the upper arm's muscle. In sensing system we use flex sensors which is electrical resistance type sensor. The sensor is attached on the biceps brachii muscle and coracobrachialis muscle of the upper arm. We propose an algorithm to classify the one's intention of motions from the sensor signal. Using this algorithm, we extract the 4 motions which are flexion and extension of the forearm, pronation and supination of the arm. To verify the validity of the proposed algorithms we made experiments with two d.o.f. artificial arm. To reduce the control errors of the artificial arm we also proposed a fuzzy PID control algorithm which based on the errors and error rate.

Srugical treatment of aortic arch syndrome -Two cases report- (대동맥궁 증후군의 수술치료 -2례 보고-)

  • 채성수
    • Journal of Chest Surgery
    • /
    • v.16 no.2
    • /
    • pp.170-174
    • /
    • 1983
  • Aortic arch syndrome is an unusual disease entity characterized by the narrowing or obliteration of major branches of the arch of the aorta regardless of etiology. We have experienced 2 cases. One of them was 22 years old office girl with 3 months history of headache, intermittent syncope and weakness and claudication on left arm especially during her physical exercise. On physical examination, pulseless on left antecubital and radial artery and blood pressure on left arm was inable to check and coldness with weakness were noted on the same side. Aortic angiography reealed 34% narrowing of left subclavian artery as that of right. But both common carotid artery and both axillary arterial patency were relatively good. Through right supraclavicular and left axillary incision, bypass graft with Gore-tex prosthesis (I.D. 6mm, Length 25 cm) was implanted from right subclavian artery on 2cm distal to origin of right common carotid arery to left axillary artery distal to axillary fossa. End to side anastomosis with preservation of left subclavian artery was done. Postoperative state was stable with blood pressure of 110/70 mmHg on left arm and palpable antecubital and radial pulsation. Another one was 41 year old male patient with 8 months history of pain and numbness on right upper arm and shoulder. On admission, right arm blood pressure was 110/80 mmHg, left arm was 160/110 mmHg, but other physical findings had no abnormalities. Angiography revealed segmental narrowing of right axillary artery on the beginning with 2 cm in length. Operative treatment with right wupraclavicular and right axillary incision, bypass graft with great saphenous vein (Length; 15 cm) from right subclavian artery between scalenus anticus and medius to axillary artery at distal end of axillary fossa was done. The authors report two cases of Aortic arch syndrome treated with bypass graft using Autograft or Gore-tex with good result.

  • PDF

Clinical outcomes of a low-cost single-channel myoelectric-interface three-dimensional hand prosthesis

  • Ku, Inhoe;Lee, Gordon K.;Park, Chan Yong;Lee, Janghyuk;Jeong, Euicheol
    • Archives of Plastic Surgery
    • /
    • v.46 no.4
    • /
    • pp.303-310
    • /
    • 2019
  • Background Prosthetic hands with a myoelectric interface have recently received interest within the broader category of hand prostheses, but their high cost is a major barrier to use. Modern three-dimensional (3D) printing technology has enabled more widespread development and cost-effectiveness in the field of prostheses. The objective of the present study was to evaluate the clinical impact of a low-cost 3D-printed myoelectric-interface prosthetic hand on patients' daily life. Methods A prospective review of all upper-arm transradial amputation amputees who used 3D-printed myoelectric interface prostheses (Mark V) between January 2016 and August 2017 was conducted. The functional outcomes of prosthesis usage over a 3-month follow-up period were measured using a validated method (Orthotics Prosthetics User Survey-Upper Extremity Functional Status [OPUS-UEFS]). In addition, the correlation between the length of the amputated radius and changes in OPUS-UEFS scores was analyzed. Results Ten patients were included in the study. After use of the 3D-printed myoelectric single electromyography channel prosthesis for 3 months, the average OPUS-UEFS score significantly increased from 45.50 to 60.10. The Spearman correlation coefficient (r) of the correlation between radius length and OPUS-UEFS at the 3rd month of prosthetic use was 0.815. Conclusions This low-cost 3D-printed myoelectric-interface prosthetic hand with a single reliable myoelectrical signal shows the potential to positively impact amputees' quality of life through daily usage. The emergence of a low-cost 3D-printed myoelectric prosthesis could lead to new market trends, with such a device gaining popularity via reduced production costs and increased market demand.

Development of a Control Strategy for a Multifunctional Myoelectric Prosthesis

  • Kim Seung-Jae;Choi Hwasoon;Youm Youngil
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.4
    • /
    • pp.243-249
    • /
    • 2005
  • The number of people who have lost limbs due to amputation has increased due to various accidents and diseases. Numerous attempts have been made to provide these people with prosthetic devices. These devices are often controlled using myoelectric signals. Although the success of fitting myoelectric signals (EMG) for single device control is apparent, extension of this control to more than one device has been difficult. The lack of success can be attributed to inadequate multifunctional control strategies. Therefore, the objective of this study was to develop multifunctional myoelectric control strategies that can generate a number of output control signals. We demonstrated the feasibility of a neural network classification control method that could generate 12 functions using three EMG channels. The results of evaluating this control strategy suggested that the neural network pattern classification method could be a potential control method to support reliability and convenience in operation. In order to make this artificial neural network control technique a successful control scheme for each amputee who may have different conditions, more investigation of a careful selection of the number of EMG channels, pre-determined contractile motions, and feature values that are estimated from the EMG signals is needed.

Bone-level implants placed in the anterior maxilla: an open-label, single-arm observational study

  • Gao, EnFeng;Hei, Wei-Hong;Park, Jong-Chul;Pang, KangMi;Kim, Sun Kyung;Kim, Bongju;Kim, Soung-Min;Lee, Jong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.5
    • /
    • pp.312-327
    • /
    • 2017
  • Purpose: This study assessed marginal bone remodeling and soft tissue esthetics after the loading of single bone-level implants in the anterior maxilla. Methods: An open, single-arm observational clinical trial with 3 years of follow-up was performed, including 22 implants. The patients presented with a single tooth gap in the anterior maxilla (tooth positions 14-24), with natural or restored adjacent teeth. An implant was placed at least 8 weeks post-extraction and healed submerged for 6 weeks. After the second-stage operation, a fixed provisional prosthesis was provided. The final restoration was placed 6 months after the provisional restoration. The time of the provisional crown connection was considered to be the baseline in this study. Esthetic parameters and the marginal bone level were assessed at 6, 12, 24, and 36 months. Results: All implants were well integrated in the bone. A statistically significant increase was found in the mean implant stability quotient between the time of the provisional prosthesis and the time of the final prosthesis. Most implants (95.5%) revealed marginal bone resorption (<0.5 mm), and just 1 implant (4.5%) showed a change of 2.12 mm from baseline to 36 months (mean $0.07{\pm}0.48mm$), while the crestal bone level decreased significantly, from $2.34{\pm}0.93mm$ at baseline to $1.70{\pm}1.10mm$ at 36 months. The facial gingival margin and papilla were stable and the esthetic scores indicated high patient and dentist satisfaction. Conclusions: Platform-switching bone-level implants placed in maxillary single-tooth gaps resulted in successful osseointegration with minimal marginal bone resorption. The peri-implant soft tissue was also esthetically satisfying and stable.

Clinical animal test for development of osseointegration implant;application for beagle tibia (골융합 임플란트 개발을 위한 동물임상실험;비글견 경골 적용)

  • Choi, Kyong-Joo;Kim, Shin-Ki;Mun, Mu-Seong;An, Jae-Yong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1373-1377
    • /
    • 2003
  • Current prostheses for amputees are generally extrinsic wearing socket type that the coupling between body stump and appliance wraps the soft tissue and this structure causes several problems :applying direct weight to soft tissue such as skin and muscle, skin trouble of contacting area and pain. In this study, osseointegration implant is a method to directly connect prosthesis to the residual stump skeletal tissue of arm, finger and leg through surgical operation. Technology presented in this paper essentially solves the problems of pain and abnormal weight transfer system indicated above and recovers the functions of the amputated arm and leg. In this paper, implant shape was designed for the first step for the development of osseointegration implant and then we studied the possibility to apply this osseointegration implant to human body by performing implant insertion operation to beagle tibia for the clinical animal test and normal beagle's gait analysis was executed in order to quantitatively verify the beagle's skeletal functions after the implant insertion.

  • PDF