• Title/Summary/Keyword: prompt engineering

Search Result 301, Processing Time 0.023 seconds

Beam Characteristics of Polychromatic Diffracted Neutrons Used for Prompt Gamma Activation Analysis

  • S. H. Byun;G. M. Sun;Park, H. D.
    • Nuclear Engineering and Technology
    • /
    • v.34 no.1
    • /
    • pp.30-41
    • /
    • 2002
  • The neutron beam is fully characterized for the prompt gamma activation analysis facility at Hanaro in the Korea Atomic Energy Research Institute(KAERI). The facility uses thermal neutrons which are diffracted vertically from a horizontal beam port by a set of pyrolytic graphite(PG) crystals positioned at the Bragg angle of 45" Neutron spectra, neutron flux and Cd-ratio are determined for the three extraction modes of diffracted beam by means of the theoretical and experimental efforts. To obtain theoretical result, the reflectivity of pyrolytic graphite is calculated in the diffraction model for mosaic crystal and the angular divergence after diffraction by mosaic crystal is estimated from Monte Carlo simulation. The time-of-flight spectrometer and gold activation wire are used for measuring the neutron spectra. Both the calculated and measured spectra have proven that the unique feature of polychromatic beam obtained by PG crystals are useful for PGAA. The thermal neutron flux of 7.9$\times$107 n/cm$^2$s and the Cd-ratio of 266 for gold have been achieved at the sample position while the reactor operates at 24 MW The uniformity of beam flux is 12% in the central 1$\times$1 cm$^2$ area. Finally, the beam is briefly characterized by the effective velocity and temperature which are determined by measuring the prompt Y-ray spectra for thin and thick boron samples.ples.

Development of Two-dimensional Prompt-gamma Measurement System for Verification of Proton Dose Distribution (이차원 양성자 선량 분포 확인을 위한 즉발감마선 이차원분포 측정 장치 개발)

  • Park, Jong Hoon;Lee, Han Rim;Kim, Chan Hyeong;Kim, Sung Hun;Kim, Seonghoon;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.42-51
    • /
    • 2015
  • In proton therapy, verification of proton dose distribution is important to treat cancer precisely and to enhance patients' safety. To verify proton dose distribution, in a previous study, our team incorporated a vertically-aligned one-dimensional array detection system. We measured 2D prompt-gamma distribution moving the developed detection system in the longitudinal direction and verified similarity between 2D prompt-gamma distribution and 2D proton dose distribution. In the present, we have developed two-dimension prompt-gamma measurement system consisted of a 2D parallel-hole collimator, 2D array-type NaI(Tl) scintillators, and multi-anode PMT (MA-PMT) to measure 2D prompt-gamma distribution in real time. The developed measurement system was tested with $^{22}Na$ (0.511 and 1.275 MeV) and $^{137}Cs$ (0.662 MeV) gamma sources, and the energy resolutions of 0.511, 0.662 and 1.275 MeV were $10.9%{\pm}0.23p%$, $9.8%{\pm}0.18p%$ and $6.4%{\pm}0.24p%$, respectively. Further, the energy resolution of the high gamma energy (3.416 MeV) of double escape peak from Am-Be source was $11.4%{\pm}3.6p%$. To estimate the performance of the developed measurement system, we measured 2D prompt-gamma distribution generated by PMMA phantom irradiated with 45 MeV proton beam of 0.5 nA. As a result of comparing a EBT film result, 2D prompt-gamma distribution measured for $9{\times}10^9$ protons is similar to 2D proton dose distribution. In addition, the 45 MeV estimated beam range by profile distribution of 2D prompt gamma distribution was $17.0{\pm}0.4mm$ and was intimately related with the proton beam range of 17.4 mm.

Stable Diffusion-based Prompt Engineering for Generating Virtual Interviewers (가상 면접관 생성을 위한 Stable Diffusion 기반의 프롬프트 엔지니어링)

  • Daemin Kim;Jongwook Si;Seungjae Son;Minsik Woo;Sungyoung Kim
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2023.07a
    • /
    • pp.23-24
    • /
    • 2023
  • 가상 면접은 현대 사회에서 필수적인 기술이지만, 상호작용의 부족으로 인해 한계가 존재한다. 현실적이고 현장감 있는 가상 면접을 구현하기 위해서는 면접관을 자동으로 생성하여 다양한 상황에서의 면접을 진행할 필요가 있다. 본 논문은 Stable Diffusion 기반의 프롬프트 엔지니어링을 통해 가상 면접관 생성에 대한 연구 결과를 제시한다. 프롬프트 엔지니어링은 Stable Diffusion 모델이 생성하는 결과의 품질을 향상시킬 수 있으며 다양한 조건에 따른 실험 결과를 제시한다.

  • PDF

Performance of a Compton Suppression Spectrometer of the SNU-KAERI PGAA Facility

  • Sun Gwang Min;Park Chang Su;Choi H.D.
    • Nuclear Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.347-355
    • /
    • 2003
  • The \gamma-ray spectrometer of the PGAA (Prompt Gamma Activation Analysis) facility constructed at HANARO of the Korea Atomic Energy Research Institute was upgraded to the multi-mode spectrometer including the single mode, the Compton suppression mode and the pair mode. The performance of the spectrometer was tested and summarized. The background count rate and the uncertainty of the detection efficiency were reduced greatly in comparison with those before the new installation.

Development of Dual-mode Signal Processing Module for Multi-slit Prompt-gamma Camera (다중 슬릿 즉발감마선 카메라를 위한 이중모드 신호처리 모듈 개발)

  • Park, Jong Hoon;Lee, Han Rim;Kim, Sung Hun;Kim, Chan Hyeong;Shin, Dong Ho;Lee, Se Byeong;Jeong, Jonh Hwi
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.37-45
    • /
    • 2016
  • In proton therapy, in vivo proton beam range verification is very important to deliver conformal dose to the target volume and minimize unnecessary dose to normal tissue. For this purpose, a multi-slit prompt-gamma camera module made of 24 scintillation detectors and 24-channel signal processing system is under development. In the present study, we have developed and tested a dual-mode signal processing system, which can operate in the energy calibration mode and the fast data acquisition mode, to process the signals from the 24 scintillation detectors. As a result of performance test, using the energy calibration mode, we were able to perform energy calibration for the 24 scintillation detectors at the same time and determine the discrimination levels for the detector channels. Further, using the fast data acquisition mode, we were able to measure a prompt-gamma distribution induced by a 45 MeV proton beam. The measured prompt gamma distribution was found similar to the proton dose distribution at the distal fall-off region, and the estimated beam range was $17.13{\pm}0.76mm$, which is close to the proton beam range of 16.15 mm measured by an EBT film.

A Plan for a Prompt Disaster Response System Using a 3D Disaster Management System Based on High-Capacity Geographic and Disaster Information (고용량 지리정보 및 재난 정보 기반 3차원 재난 관리 시스템을 활용한 신속한 재난 대응 체계 방안 제시)

  • GANG, Su-Myung;KIM, Do-Ryeong;CHOUNG, Yun-Jae;PARK, Ju-Sung;KIM, Jin-Man;JO, Myung-Hee
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.19 no.1
    • /
    • pp.180-196
    • /
    • 2016
  • To minimize the damage from disasters, various aspects of prevention, preparation, and response, etc. are being managed. Even though prevention and preparation are well conducted, irresistible calamities such as natural disasters may cause unexpected damage. Therefore, a system that can share the identical disaster information based on prompt disaster management and prediction must be developed and constructed for integrated disaster management. Especially, for a prompt disaster response, the same information needs to be shared between the related organization and the disaster prevention personnel such as on-site officials. Recent disaster management systems use high-capacity geographic information or other various factors for accurate disaster predictions. In case of using a recently constructed or researched 3D GIS, the system may not be used in some cases due to conflicts with hardware, etc. Thus, even though response information is secured using prediction simulation in advance, it is essentially difficult in some cases to share the common information when the system cannot be utilized or the extension of the corresponding data cannot be read. Therefore, this study aims to construct a system for dealing with disasters that shares the same prompt and accurate information in compliance with common data formats. The system is expected to reduce the existing disaster response time and minimize human and physical damage by assisting decision making through prompt responses.

Daily adaptive proton therapy: Feasibility study of detection of tumor variations based on tomographic imaging of prompt gamma emission from proton-boron fusion reaction

  • Choi, Min-Geon;Law, Martin;Djeng, Shin-Kien;Kim, Moo-Sub;Shin, Han-Back;Choe, Bo-Young;Yoon, Do-Kun;Suh, Tae Suk
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.3006-3016
    • /
    • 2022
  • In this study, the images of specific prompt gamma (PG)-rays of 719 keV emitted from proton-boron reactions were analyzed using single-photon emission computed tomography (SPECT). Quantitative evaluation of the images verified the detection of anatomical changes in tumors, one of the important factors in daily adaptive proton therapy (DAPT) and verified the possibility of application of the PG-ray images to DAPT. Six scenarios were considered based on various sizes and locations compared to the reference virtual tumor to observe the anatomical alterations in the virtual tumor. Subsequently, PG-rays SPECT images were acquired using the modified ordered subset expectation-maximization algorithm, and these were evaluated using quantitative analysis methods. The results confirmed that the pixel range and location of the highest value of the normalized pixel in the PG-rays SPECT image profile changed according to the size and location of the virtual tumor. Moreover, the alterations in the virtual tumor size and location in the PG-rays SPECT images were similar to the true size and location alterations set in the phantom. Based on the above results, the tumor anatomical alterations in DAPT could be adequately detected and verified through SPECT imaging using the 719 keV PG-rays acquired during treatment.

Implementation and design of Improved Evaluation Tool for Web Accessibility (개선된 웹 접근성 평가도구의 설계 및 구현)

  • Moon, Kyung-Sil;Choi, Jung-Yun;Park, Su-Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.375-378
    • /
    • 2008
  • 웹 접근성(Web Accessibility) 평가를 위하여 웹 접근성 표준 가이드라인에 기반 한 120여개의 자동화 평가 도구들이 존재한다. 국외 평가도구는 WCAG 1.0과 미국 재활법 508조를 기준으로 만들어진 A-Prompt, Bobby 등이 있으며, 국내에는 KWCAG 1.0에 기반하여 한국정보문화진흥원에서 제작한 KADO-WAH가 유일한 자동화 웹접근성 평가도구이다. KADO-WAH는 국외 평가도구와 비교하여 상세한 검사를 진행하지 않으며 자동화 평가 범위가 한정되어 있어 상당부분 전문가 평가를 필요로 한다. 이를 보완하기 위하여 개선된 웹 접근성 평가도구의 개발이 필요하다. 본 논문에서는 국내 자동화 평가도구인 KADO-WAH의 기능을 향상시키기 위하여 국외 자동화 평가도구와 비교 분석을 통해 KADO-WAH의 문제점을 제시하고, 이 문제점을 개선한 웹 접근성 평가도구를 구현한다.

  • PDF

Preliminary Study for Imaging of Therapy Region from Boron Neutron Capture Therapy (붕소 중성자 포획 치료에서 치료 영역 영상화를 위한 예비 연구)

  • Jung, Joo-Young;Yoon, Do-Kun;Han, Seong-Min;Jang, HongSeok;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.151-156
    • /
    • 2014
  • The purpose of this study was to confirm the feasibility of imaging of therapy region from the boron neutron capture therapy (BNCT) using the measurement of the prompt gamma ray depending on the neutron flux. Through the Monte Carlo simulation, we performed the verification of physical phenomena from the BNCT; (1) the effects of neutron according to the existence of boron uptake region (BUR), (2) the internal and external measurement of prompt gamma ray dose, (3) the energy spectrum by the prompt gamma ray. All simulation results were deducted using the Monte Carlo n-particle extended (MCNPX, Ver.2.6.0, Los Alamos National Laboratory, Los Alamos, NM, USA) simulation tool. The virtual water phantom, thermal neutron source, and BURs were simulated using the MCNPX. The energy of the thermal neutron source was defined as below 1 eV with 2,000,000 n/sec flux. The prompt gamma ray was measured with the direction of beam path in the water phantom. The detector material was defined as the lutetium-yttrium oxyorthosilicate (Lu0,6Y1,4Si0,5:Ce; LYSO) scintillator with lead shielding for the collimation. The BUR's height was 5 cm with the 28 frames (bin: 0.18 cm) for the dose calculation. The neutron flux was decreased dramatically at the shallow region of BUR. In addition, the dose of prompt gamma ray was confirmed at the 9 cm depth from water surface, which is the start point of the BUR. In the energy spectrum, the prompt gamma ray peak of the 478 keV was appeared clearly with full width at half maximum (FWHM) of the 41 keV (energy resolution: 8.5%). In conclusion, the therapy region can be monitored by the gamma camera and single photon emission computed tomography (SPECT) using the measurement of the prompt gamma ray during the BNCT.

A Case Study of Dispute Mediations on Construction Noise and Vibration Damages (건설소음진동 피해분쟁조정 사례분석에 관한 연구)

  • 곽광수;김재수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.108-113
    • /
    • 2001
  • Recently people have come to demand more pleasant environments as the quality and right of life have been improved. Along with industrial development, the tendency is causing a growing number of disputes concerning environmental damages. Of many kinds of environmental damages, noise and vibration pollution rising at construction fields are particularly the most common subjects of public grievance. Thus the government launched the Environmental Dispute Mediation Committee in 1991, purposing to utilize fully the promptness and expertise of administrative institutes and to resolve environmental damage disputes promptly and fairly by interfering in them actively. With the prompt and fair dispute mediations of the committee, people came to be able to get fair and prompt remedies for damages in their health and fortune by environmental pollution. Therefore, by analyzing dispute mediation cases on construction noise and vibration damages, we will suggest basic material on which efficient actions can be taken for public grievances happening in the future.

  • PDF