• Title/Summary/Keyword: profile measurement

Search Result 912, Processing Time 0.028 seconds

A Study on Determination of the Area Function of Nano Indenter Tip with AFM (AFM을 이용한 나노 인덴터 팁의 면적함수 결정에 관한 연구)

  • 박성조;이현우;한승우
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.6
    • /
    • pp.145-152
    • /
    • 2004
  • Depth-sensing indentation is wifely used for evaluation of mechanical properties of thin films. It is generally accepted that the most significant source of uncertainty in nanoindentation measurement is the geometry of the indenter tip. Therefore the successful application of the technique requires accurate calibration of the indenter tip geometry. The direct measurement of geometry of a Berkovich indenter was determined using a atomic force microscope. The indentation geometrical calibration of contact area was performed by analyzing the indenter tip profile. The equations of area functions were proposed for nanoscale thin films..

A Study on the Distribution of Friction Heat generated by CMP Process (CMP 공정에서 발생하는 연마온도 분포에 관한 연구)

  • 김형재;권대희;정해도;이용숙;신영재
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.3
    • /
    • pp.42-49
    • /
    • 2003
  • In this paper, we provide the results of polishing temperature distribution by way of infrared ray measurement system as well as polishing resistance, which can be interpreted as tribological aspects of CMP, using force measurement system. The results include the trend of polishing temperature, its distribution profile and temperature change during polishing. The results indicate that temperature affects greatly to the removal rate. Polishing temperature increases gradually and reaches steady state temperature and the period of temperature change occurs first tens of seconds. Furthermore, the friction force also varies as the same pattern with polishing temperature from high friction to low. These results suggest that the first period of the whole polishing time greatly affects the nonuniformity of removal rate.

$CO_2$ Laser Absorption Measurement of $CH_3CH_2Br$ using Photoacoustic Method

  • Jang Soo Shin;Kyung Hoon Jung;Cheol Jung Kim
    • Bulletin of the Korean Chemical Society
    • /
    • v.13 no.5
    • /
    • pp.553-556
    • /
    • 1992
  • The ${CO}_2$ laser absorption measurement of ${CH}_3{CH}_2Br$ utilizing photoacoustic (PA) technique was performed using a cw and a pulsed ${CO}_2$ lasers. The absorption profile in the ${CO}_2$ laser wavelength region (9-10 ${\mu}$m) and the macroscopic small signal absorption cross section at 10P(20) (10.59 ${\mu}$m, 944 $cm^{-1}$) laser line were measured using a cw ${CO}_2$ laser. The laser fluence dependence on infrared multiphoton absorption (IRMPA) was also studied with a pulsed TEA ${CO}_2$ laser at 10P(20) laser line. In view of monotonic increase of PA signal with the rise of laser fluence, it was suggested that the anharmonicity in pumped vibration mode did not restrict ir multiphoton absorption in ${CH}_3{CH}_2Br$ system as found in large molecular system.

An Evaluation Model for Analyzing the Overlay Error of Computer-generated Holograms

  • Gan, Zihao;Peng, Xiaoqiang;Hong, Huajie
    • Current Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.277-285
    • /
    • 2020
  • Computer-generated holograms (CGH) are the core devices to solve the problem of freeform surface measurement. In view of the overlay error introduced in the manufacturing process of CGH, this paper proposes an evaluation model for analyzing the overlay error of CGH. The detection method of extracting CGH profile information by an ultra-depth of field micro-measurement system is presented. Furthermore, based on the detection method and technical scheme, the effect of overlay error on the wavefront accuracy of CGH can be evaluated.

Long-term measurement of physiological cardiovascular parameters using telemetry system in dosgs.

  • Kim, Eun-Joo;Seo, Joung-Wook;Choi, Gyu-Kap;Park, Eun-Kyung;Kim, Ki-Suk;Shin, Won-Ho;Han, Sang-Seop
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.87.1-87.1
    • /
    • 2003
  • With the issuance of the ICH “Guidance for industry S7A Safety Pharmacology Studies For Human Pharmaceuticals” in July 2001 came the preference for the use of unanesthetized animals when evaluation the safety profile of new pharmaceutical agents. Telemetry provides a means of obtaining measurements of physiological functions in conscious animals without the problems associated with classical cardiovascular measuring methods. The Korea Institute of Toxicology (KIT) established the telemetric measurement of cardiovascular parameters, such as Blood pressure, Heart rate, ECG (PR, RR, QRS, QT and QTcB interval) under GLP conditions. (omitted)

  • PDF

A Study on the In-Process Measurement of Rotary Body by Optical Technique (광학적 기법을 이용한 회전체 인프로세스 측정에 관한 연구)

  • So, Eui-Yeorl;Im, Young-Ho;Ryu, Bong-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.5
    • /
    • pp.148-156
    • /
    • 1996
  • Automatic product system is gradually increasing according to development of industrial society. On-line measurement makes a important role in view of economic and effective side in industrial product system. Syncronization system is developed to measure screw thread which is rotating. In-process measuring of rotating body have a lot of difficuties even thoufht using various method containing high speed camera. So, now we suggest one of the new method which is not so expansive. In this study, digital value was produced through the image processing algorithm from acquired orignal image. As a result, we have a good agreement between measuring values calculated from image conture and measuring values acquired from profile project by means of experiment, respectively.

  • PDF

Partial Spectrum Detection and Super-Gaussian Window Function for Ultrahigh-resolution Spectral-domain Optical Coherence Tomography with a Linear-k Spectrometer

  • Hyun-Ji, Lee;Sang-Won, Lee
    • Current Optics and Photonics
    • /
    • v.7 no.1
    • /
    • pp.73-82
    • /
    • 2023
  • In this study, we demonstrate ultrahigh-resolution spectral-domain optical coherence tomography with a 200-kHz line rate using a superluminescent diode with a -3-dB bandwidth of 100 nm at 849 nm. To increase the line rate, a subset of the total number of camera pixels is used. In addition, a partial-spectrum detection method is used to obtain OCT images within an imaging depth of 2.1 mm while maintaining ultrahigh axial resolution. The partially detected spectrum has a flat-topped intensity profile, and side lobes occur after fast Fourier transformation. Consequently, we propose and apply the super-Gaussian window function as a new window function, to reduce the side lobes and obtain a result that is close to that of the axial-resolution condition with no window function applied. Upon application of the super-Gaussian window function, the result is close to the ultrahigh axial resolution of 4.2 ㎛ in air, corresponding to 3.1 ㎛ in tissue (n = 1.35).

Development of a Stereo Vision Sensor-based Volume Measurement and Cutting Location Estimation Algorithm for Portion Cutting (포션커팅을 위한 스테레오 비전 센서 기반 부피 측정 및 절단 위치 추정 알고리즘 개발)

  • Ho Jin Kim;Seung Hyun Jeong
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.19 no.5
    • /
    • pp.219-225
    • /
    • 2024
  • In this study, an algorithm was developed to measure the volume of meat products passing through the conveyor line of a portion cutter using a stereo vision sensor and calculate the cutting position to cut them into the same weight unit. Previously, three or more laser profile sensors were used for this purpose. However, in this study, the volume was measured using four stereo vision sensors, and the accuracy of the developed algorithm was verified to confirm the applicability of the technique. The technique consists of stereo correction, scanning and outlier removal, and cutting position calculation procedures. The comparison between the volume measured using the developed algorithm and the results measured using an accurate 3D scanner confirmed an accuracy of 91%. Additionally, in the case of 50g target weight, where the cutting position calculation is crucial, the cutting position was calculated at a speed of about 2.98 seconds, further confirming the applicability of the developed technique.

Accuracy Analysis of Close-Range Digital Photogrammetry for Measuring Displacement about Loading to Structure (하중에 따른 구조물 변위계측을 위한 근접수치사진측량의 정확도 분석)

  • Choi, Hyun;Ahn, Chang Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4D
    • /
    • pp.545-553
    • /
    • 2009
  • This paper describes the result of study on measurement of displacement of structure by means of non-contacting method, close-range digital photogrammetry using digital camera. To apply close-range digital photogrammetry to displacement measurement of structure, correction of lens distortion that interferes geometrical analysis has been carried out and then measuring displacement was performed on load regulated-rahmen. For enhanced applicability of displacement measurement, MIDAS which is a structural analysis program was used for modeling and the result was taken from comparative analysis. As a result of the study, it is showed that close-range digital photogrammetry could supplement several weaknesses of LVDT and cable displacement meter and, especially, economy in the perspective of measuring time could be realized. Close-range digital photogrammetry using digital camera can be applied to the area where requires visual analysis such as 3D modeling of structure, profile replication of measurement of structure as well as measurement of displacement of structure.

Principles and Applications of Multi-Level H2O/CO2 Profile Measurement System (다중 수증기/이산화탄소 프로파일 관측 시스템의 원리와 활용)

  • Yoo, Jae-Ill;Lee, Dong-Ho;Hong, Jin-Kyu;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.11 no.1
    • /
    • pp.27-38
    • /
    • 2009
  • The multi-level profile system is designed to measure the vertical profile of $H_2O$ and $CO_2$ concentrations in the surface layer to estimate the storage effects within the plant canopy. It is suitable for long-term experiments and can be used also in advection studies for estimating the spatial variability and vertical gradients in concentration. It enables the user to calculate vertical fluxes of water vapor, $CO_2$ and other trace gases using the surface layer similarity theory and to infer their sources or sinks. The profile system described in this report includes the following components: sampling system, calibration and flow control system, closed path infrared gas analyzer(IRGA), vacuum pump and a datalogger. The sampling system draws air from 8 inlets into the IRGA in a sequence, so that for 80 seconds air from all levels is measured. The calibration system, controlled by the datalogger, compensates for any deviations in the calibration of the IRGA by using gas sources with known concentrations. The datalogger switches the corresponding valves, measures the linearized voltages from the IRGA, calculates the concentrations for each monitoring level, performs statistical analysis and stores the final data. All critical components are mounted in an environmental enclosure and can operate with little maintenance over long periods of time. This report, as a practical manual, is designed to provide helpful information for those who are interested in using profile system to measure evapotranspiration and net ecosystem exchanges in complex terrain.