• Title/Summary/Keyword: process water

Search Result 9,553, Processing Time 0.034 seconds

Water and mass balance analysis for hydrological model development in paddy fields

  • Tasuku, KATO;Satoko, OMINO;Ryota, TSUCHIYA;Satomi, TABATA
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.238-238
    • /
    • 2015
  • There are demands for water environmental analysis of discharge processes in paddy fields, however, it is not fully understood in nutrients discharge process for watershed modeling. As hydrological processes both surface and ground water and agricultural water managements are so complex in paddy fields, the development of lowland paddy fields watershed model is more difficult than upland watershed model. In this research, the improvement of SWAT (Soil and Water Assessment Tool) model for a paddy watershed was conducted. First, modification of surface inundated process was developed in improved pot hole option. Those modification was evaluated by monitoring data. Second, the monitoring data in river and drainage channel in lowland paddy fields from 2012 to 2014 were analyzed to understand discharge characteristics. As a case study, Imbanuma basin, Japan, was chosen as typical land and water use in Asian countries. In this basin, lowland paddy fields are irrigated from river water using small pumps that were located in distribution within the watershed. Daily hydrological fluctuation was too complex to estimate. Then, to understand surface and ground water discharge characteristics in irrigation (Apr-Aug) and non-irrigation (Sep-Mar) period, the water and material balance analysis was conducted. The analysis was composed two parts, watershed and river channel blocks. As results of model simulation, output was satisfactory in NSE, but uncertainty was large. It would be coming from discharge process in return water. The river water and ground water in paddy fields were exchanged each other in 5.7% and 10.8% to river discharge in irrigation and non-irrigation periods, respectively. Through this exchange, nutrient loads were exchanged between river and paddy fields components. It suggested that discharge from paddy fields was not only responded to rainfall but dynamically related with river water table. In general, hydrological models is assumed that a discharge process is one way from watershed to river. However, in lowland paddy fields, discharge process is dynamically changed. This function of paddy fields showed that flood was mitigated and temporally held as storage in ground water. Then, it showed that water quality was changed in mitigated function in the water exchange process in lowland paddy fields. In future, it was expected that hydrological models for lowland paddy fields would be developed with this mitigation function.

  • PDF

The effect of physicochemical factors on the coagulation process (응집에 영향을 미치는 물리-화학 인자)

  • Kim, Sung-Goo;Ryu, Jae-Ick;Ryou, Dong-Choon;Kim, Jeong-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.1
    • /
    • pp.81-87
    • /
    • 1997
  • Coagulation is very important process in water works. The subsequent processes are directly affected by this process. Many factors such as turbidity, alkalinity, pH, hardness, total organic carbon(TOC), velocity gradient and flocculation time effect on coagulation process. Among these factors, specially TOC is being concerned target substance to be removed due to trihalomenthanes(THMs) precursor and alkalinity is being one of the major parameter for removing TOC. We have researched the consumption of coagulant with TOC alkalinity concentration of water and removal efficiency of residual TOC and turbidity with alkalinity. Furthermore we have investigated particle size distributions with velocity gradient and alkalinity. The consumption of coagulant was proportionally increased to TOC and alkalinity concentration and the removal of TOC in Nakdong river water was very difficult more than 150 mg/l in alkalinity but large morecular weight organic such as humic acid could be removed easily. Coagulation of low alkalinity water was more rapidly occured than of high alkalinity water by analyzing the particle size distributions. High alkalinity water needed higher mixing energy for a good coagulation within limited flocculation time.

  • PDF

Substitutability of coagulation process by pre-treatment of coagulation·flotation using natural algae coagulant (천연조류제거제를 활용한 응집·부상 전처리공정의 기존 응집공정 대체 가능성)

  • Jang, Yeo-Ju;Jung, Jin-Hong;Lim, Hyun-Man;Chang, Hyang-Youn;Kim, Weon-Jae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.1
    • /
    • pp.39-50
    • /
    • 2017
  • In the coagulation/sedimentation (C/S) process of the water treatment process, the inflow of massive algal bloom causes many problems including fouling of filter media. This study was conducted to find out the way to remove the algae's harmful effects by addition of pre-treatment prior to C/S process. Many Jar-tests were conducted such as (1) ACF (Algae Coagulation Flotation) process using natural algae coagulant (Water $Health^{(R)}$), (2) ACF + C/S process and (3) C/S process with a variety of conditions using cultured algae. The average values of turbidity were (1) 0.42 NTU for ACF process, (2) 0.13 NTU for ACF + C/S process and (3) 0.25 NTU for C/S process. It was shown that the treatment efficiency of ACF process could get low turbidity results, and ACF + C/S process could achieve more efficient results than those of C/S process. Any negative effects of ACF process to the efficiency of C/S process were not observed in ACF + C/S process. In order to reduce the unfavorable effects of algae, it was found out that the introduction of ACF process in the forms of (1) ACF or (2) ACF + C/S could be one of the effective and alternative solutions.

Assesment of Powdered Activated Carbon Effect on PAC+MF Hybrid Membrane Process (분말활성탄(PAC)+막여과(MF) 조합공정에서 PAC의 영향 평가)

  • Kim, Byung S.;Wang, Chang K.;Lim, Jae L.;Kim, Chung H.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.5
    • /
    • pp.517-522
    • /
    • 2008
  • This study aims at an assessment of the effectiveness of taste & odor removal and transmembrane pressure changes in a pilot membrane plant(500m3/day) by adding PAC to MF process, and at providing a basis for applying it to the advanced water treatment process. The transmembrane pressure showed, in low turbidity of raw water, a tendency to decrease when PAC was injected at the Flux of 1, $1.5m^3/m^2{\cdot}d$, while it increased in high Flux($1.5m^3/m^2{\cdot}d$) in high turbidity of raw water. in addtion, it is shown that the fouling could be reduced more when PAC is injected together with appropriate amount of coagulant, than when PAC is solely injected. Taste & Odor-causing 2-MIB may not be detected in membrane filtered water, if the amount of PAC injection is increased in accordance with the increasing concentration of 2-MIB. Hence, PAC injection, as a pre-treatment process in MF membrane filtering, is supposed to be a suitable process for reducing fouling as well as for improvement effectiveness of taste & odor treatment.

Characteristics of Adsorption and Biodegradation of Tetracycline Antibiotics by Granular Activated Carbon and Biofiltration Process (Tetracycline계 항생물질들의 활성탄 흡착 및 생물여과 공정에 의한 생분해 특성)

  • Son, Hee-Jong;Yeom, Hoon-Sik;Ryu, Dong-Choon;Jang, Seung-Ho;Son, Hyung-Sik
    • Journal of Environmental Science International
    • /
    • v.23 no.3
    • /
    • pp.379-386
    • /
    • 2014
  • Adsorption and biodegradation performance of tetracycline antibiotic compounds such as ttetracycline (TC), oxytetracycline (OTC), minocycline (MNC), chlortetracycline (CTC), doxycycline (DXC), meclocycline (MCC), demeclocycline (DMC) on granular activated carbon (GAC) and anthracite-biofilter were evaluated in this study. Removal efficiency of seven tetracycline antibiotic compounds showed 54%~97% by GAC adsorption process (EBCT: 5~30 min). The orders of removal efficiency by GAC adsorption were tetracycline, demeclocycline, oxytetracycline, chlortetracycline, doxytetracycline, meclocycline and minocycline. Removal efficiencies of seven tetracycline antibiotic compounds showed 1%~61% by anthracite biofiltration process (EBCT: 5~30 min). The highest biodegradable tetracycline antibiotic compound was minocycline, and the worst biodegradable tetracycline antibiotic compounds were oxytetracycline and demeclocycline.

Hazardous event analysis in drinking water production using aquifer storage transfer and recovery (대수층 저장·이동 및 회수에 의한 음용수 생산과정에서의 위해사건분석)

  • Lee, Sang-Il;Ji, Hyon-Wook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.1
    • /
    • pp.23-31
    • /
    • 2015
  • Aquifer storage transfer and recovery (ASTR) is a type of managed aquifer recharge which entails injecting water into a storage well and recovering it from a different well. It has effects of natural purification when injected water passes through aquifer medium, and can be a good way of supplying water especially in a region with poor surface water quality. This study is about an on-going effort to introduce ASTR as a solution to source water problems in coastal areas. A pilot study is being conducted in the delta of the Nakdong River. A proactive management system is incorporated to ensure the water qulity in the process of drinking water process. The system is based on the Hazard Analysis and Critical Control Point (HACCP) which is a tool originated from the food industry in order to assess hazards and establish control systems for the safety of food product. In this paper, we analyze hazardous events which can occur in the entire water supply system using ASTR as a first step to the incorporation of HACCP to drinking water production process.

Development of Index for Assessment of Water Resources Sustainability Using Analytic Hierarchy Process (Analytic Hierarchy Process 기법을 이용한 수자원 지속가능성 지수 개발)

  • Kang, Min-Goo;Lee, Gwang-Man
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1486-1490
    • /
    • 2005
  • 지속가능한 수자원 개발 및 관리를 위해서는 유역 내에서 진행되고 있는 수자원에 관련된 활동들이 지속가능한 개발의 개념에 부합하는지 여부를 판단해야 한다. 이를 위해서는 국가, 유역, 지자체 등의 수문, 수질, 사회, 경제, 환경적인 요인들을 고려한 다변수 평가 지수가 필요하다. 본 연구에서는 유역의 수자원을 평가할 수 있는 지표들을 선정하고 이들 간의 중요도는 계층적 분석기법(Analytic Hierarchy Process, AHP)을 사용하여 산정하였으며 이들을 종합한 수자원 지속가능성 지수(WRSI, Water Resources Sustainability Index)를 개발하였다. WRSI는 경제적 효율성 세부지수, 사회적 공평성 세부지수, 환경 보전성 세부지수, 유지관리능력 세부지수로 구성하였다. 지표들과 세부지수들 간의 중요도는 전문가들에 대한 설문조사를 통하여 산정하였다. 개발된 WRSI 구성지표들의 표준화는 이들의 적정 확률분포를 선정한 후 누가확률을 사용하여 산정하는 방법을 개발하여 사용하였다.

  • PDF

Treatment of Ballast Water By Filtration -Ultraviolet radiation-Electrolytic Process (FUE 공정에 의한 Ballast Water처리)

  • 박상호;김억조;박성진;김인수
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.8 no.2
    • /
    • pp.23-27
    • /
    • 2002
  • Reballasting at sea, as recommended by the IMO guidelines, currently provides the best-available measure to reduce the risk of transfer of harmful aquatic organisms, but is subject to serious ship-safety limits. It is therefore extremely important that alternative, effective ballast water management and treatment methods are developed as soon as possible, to replace reballasting at sea. Filtration-Ultraviolet radiation-Electrolytic process (FUE) was evaluated for disinfection of seawater used In ballast water Optimal current density and UV light intensity were 2.0A/dm$^2$ and, 220㎼/$\textrm{cm}^2$/m with which 100% reduction time was 2sec in a Ultraviolet radiation-Electrolytic process. This study showed that FUE process was effective for the disinfection of commonly isolated bacteria and bacillus from ballast water.

  • PDF

Production of Water for Injection by Membrane Process

  • Murakami, Daikichiro
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.06a
    • /
    • pp.177-189
    • /
    • 1996
  • Raverase osmosis or ultrafiltration systems have generally been regarded as hard to validate about WFI production. Though the Japanese and US Pharmacopoeias have allowed distillation and RO to be applied to WFI production process, only water stills, especially multiple effects have practically been employed for parenteral water production. On the other hand, the latest analysis has shown that even distillate contains such volatile organic matters as trihalomethanes and traces of heavy metals at a little higher concentration than supposed. The JP requires TOC to be monitored in WFI process based on RO or UF systems to control the concentration below 300ppb, but very few monographs or papers have so far been published about the concentrations of organic volatile matters in distillate. (See table 1-1) Therefore, this paper proposes a new applicable WFI systems based on the result of purified water analysis with some membranes used in the process. A well combined membrane system with other units could be expected to provide less amount of impurities in membrane-treated water than in distillate.

  • PDF

Cost comparison of pretreatment processes in large SWRO desalination plant (대규모 해수담수화 플랜트에서의 전처리공정 비용 분석)

  • Kim, Youngmin;Kim, Jin-Ho;Lee, Sangho;Lee, Chang-Kyu;Park, Kwang Duk;Choi, June-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.555-560
    • /
    • 2013
  • A cost analysis method for pretreament processes of a large scale seawater desalination plant was considered using a cost estimation model, WaTER (Water Treatment Estimation Routine). This model is based on cost functions of U.S. EPA to conduct economic analysis of water treatment facilities. A virtual seawater desalination plant which has pretreatment production capacity of $100,000m^3$ per day was chosen as a model plant. Dual media filtration and microfiltration systems were compared as pretreatment process, and the following reverse osmosis process was modeled. As a result, microfiltration showed a price competitiveness in condition of operating with reverse osmosis process by reducing the loads of water treatment and membrane cleaning despite it's high annual cost.