• Title/Summary/Keyword: process water

Search Result 9,553, Processing Time 0.036 seconds

Evaluations of Coagulation Process for Membrane Pre-treatment using Floc Growth Rate Analyzer (응집 플록 성장률 측정기를 이용한 멤브레인 공정의 전처리 응집공정 평가)

  • Son, Hee-Jong;Kim, Sang-Goo;Kim, Do-Hwan;Kang, So-Won;Choi, Young-Ik
    • Journal of Environmental Science International
    • /
    • v.25 no.2
    • /
    • pp.231-238
    • /
    • 2016
  • In this study, we have investigated to find optimal pre-treatment flocculation condition by analyzing the floc growth rate with mixing conditions and the membrane permeation flux for pre-treatment step of the membrane process. The higher mixing intensity showed a constant floc size index (FSI) values, and lower mixing intensity increased the degree of dispersion of the FSI values. Results of comparing the distribution characteristics of the FSI value and the permeation flux were more effective in increasing flux when the FSI values were 0.2 or higher. The degree of dispersion of FSI was relatively large in 40 rpm mixing condition compared to 120 rpm. In 40 rpm mixing condition, it decreased the permeation flux compared to 120 rpm because various sizes of flocs were distributed. Coagulation-UF membrane process enhanced 30%~40% of the flux rate compare to UF alone process, and the coagulation-MF process increased up to 5% of the flux rate compare to MF alone process. Pre-treatment, that is, coagulation process, has been found to be less effects on relatively larger pore size for MF membrane. For UF membrane, the flux was a little bit same when applying only the rapid mixing process or rapid mixing with slow mixing processes together. In case of MF membrane, the flux was improved when rapid mixing process applied with slow mixing process together.

A study for the recovery molybdenum from the dissolved liquid of Mo. with a clean technology (몰리브덴 용해액에서 금속의 몰리브덴회수에 대한 청정기술에 관한 연구)

  • Hong Jong-Soon
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.1 s.55
    • /
    • pp.76-83
    • /
    • 2005
  • The process of reusing the treated water generated during this process and that of recovery of molybdenum from the excessive water were studied. The results were as follows. Molybdenum recollection 1. Reusing processing water generated after dissolving process on FL/20 type, the following were the remaining Mo.'s weights after the 1st, 2nd, 3rd, 4th, 5th, & 6th dissolutions respectively. 1) The result of measuring the quantity of Mo. in processing water(the 1st solving water) generated after the 1st dissolving Mo. process was $369g/\ell$ 2) The result of measuring the quantity of Mo. in processing water(the 2nd solving water) generated after the 1st dissolving Mo. process reusing the 1st solving water was $627.3g/\ell$ 3) The result of measuring the quantity of Mo. in processing water(the 3rd solving water) generated after the dissolving Mo. process reusing the 2nd solving water was $808.11g/\ell$ 4) The result of measuring the quantity of Mo. in processing water(the 4th solving water) generated after the dissolving Mo. process reusing the 3rd solving water was $934.68g/\ell$ 5) The result of measuring the quantity of Mo. in processing water(the 5th solving water) generated after the dissolving Mo. process reusing the 4th solving water was $1023.27g/\ell$ 6) The result of measuring the quantity of Mo. in processing water(the 6th solving water) generated after the dissolving Mo. process reusing the 5th solving water was $1085.29g/\ell$ 2. The followings were the results of recollectings Mo. in processing water respectively generated after dissolving Mo. to produce complete goods df FL/20 type filament. 1) the percentage of recollecting Mo. in the 1st solving water was $93.0\%$ 2) the percentage of recollecting Mo. in the 2nd solving water was $94.5\%$ 3) the percentage of recollecting Mo. in the 3rd solving water was $95.5\%$ 4) the percentage of recollecting Mo. in the 4th solving water was $96.0\%$ 5) the percentage of recollecting Mo. in the 5th solving water was $96.2\%$ 6) the percentage of recollecting Mo. in the 6th solving water was $96.4\%$ 3. The followings were the results of analyzing, with ICP, holding quantities of Mo. in the 6 processing waters to produce FL/20 type filament after passing a 3 staged solid-liquid separator through, dehydrating and drying for more than 3 hours in a dryer to recollect solving Mo. in them 1) the Mo. holding percentage in the 1st solving water was $76.6\%$ 2) the Mo. holding percentage in the 2nd solving water was $76.6\%$ 3) the Mo. holding percentage in the 3rd solving water was $76.6\%$ 4) the Mo. holding percentage in the 4th solving water was $76.6\%$ 5) the Mo. holding percentage in the 5th solving water was $76.6\%$ 6) the Mo. holding percentage in the 6th solving water was $76.6\%$ It was noted that with the number of times the recollecting Mo. percentage become higher, and in spite of much recollecting, without any large effect on the goods the solving water could be reused as the processing water. Because the collected Mo. holding percentages were more than $76\%$, it is considered they are very good one than Chinese Mo. ores with $50\%$ degrees of purity, worthy of recollecting Mo.

Distribution of Acanthamoeba spp. in Raw Water and Water Treatment Process (상수원수 및 정수처리공정별 가시아메바 분포특성에 관한 연구)

  • Jung, Eun-Young;Jung, Mi-Eun;Park, Hong-Gi;Jung, Jong-Moon;Rho, Jae-Sun;Ryu, Pyung-Jong
    • Journal of Environmental Science International
    • /
    • v.17 no.10
    • /
    • pp.1121-1127
    • /
    • 2008
  • The free-living amoeba and Acanthamoeba sp. are widely distributed in fresh water, soil, air and dust in the world. We studied distribution of amoeba from low Nakdong River(Mulgum and Maeri) and removal efficiency in water treatment process of Busan metropolitan city. During this investigation, water quality showed pH $7.4{\sim}9.6({\pm}1.1)$, water temperature $2.0{\sim}29.0({\pm}17)^{\circ}C$, turbidity $4.8{\sim}27.4({\pm}11.0)$ NTU, chlorophyll-a $10.3{\sim}109.0({\pm}44.3)\;mg/m^{3}$, BOD $1.7\sim4.9({\pm}2.6)$ mg/L, COD $3.1\sim-6.9({\pm}5.0)$ mg/L and total coliform $17\sim920({\pm}200.5)$ MPN/100 mL. The free-living amoeba were detected highly than Acanthamoeba sp., 11 out of 22 in raw water samples were positive (50%) for Acanthamoeba sp. from February 2005 to December 2005. The seasonal characteristics of tree-living amoeba and Acanthamoeba sp. in raw water were mainly distributed through the spring to the early fall. When tree-living amoeba and Acanthamoeba sp. were passed through the water treatment of pilot-plant, approximately 80% was sure to be removed through pre-ozonation, sedimentation, send filtration. 100% was removed after post-ozonation process. All of the isolated amoebas from Nakdong River were Acanthamoeba sp. AC311 18S ribosomal RNA gene with 98% nucleotide sequence homology.

Evaluation of Haloacetic Acid Formation Potential in Drinking Water Treatment Process by Fraction Technique (정수처리 공정에서 용존 유기물질 분류에 의한 haloacetic acid 생성능 평가)

  • Son, Hee-Jong;Hwang, Young-Do;Ryu, Dong-Choon;Jung, Chul-Woo;Lee, Gun;Son, Hyeng-Sik
    • Journal of Environmental Science International
    • /
    • v.23 no.9
    • /
    • pp.1655-1662
    • /
    • 2014
  • A comprehensive fractionation technique was applied to a set of water samples obtained along drinking water treatment process with ozonation and biological activated carbon (BAC) process to obtain detailed profiles of dissolved organic matter (DOM) and to evaluate the haloacetic acid (HAA) formation potentials of these DOM fractions. The results indicated that coagulation-sedimentation-sand filtration treatment showed limited ability to remove hydrophilic fraction (28%), while removal of hydrophobic and transphilic fraction were 57% and 40%, respectively. And ozonation and BAC treatment showed limited ability to remove hydrophobic fractions (6%), while removal of hydrophilic and transphilic fractions were 25% and 18%. The haloacetic acid formation potential (HAAFP)/dissolved organic carbon (DOC) of hydrophilic fraction was the highest along the treatment train and HAAFP/DOC of hydrophilic fraction was higher than hydrophobic and transphilic fraction as 23%~30%, because of better removal for hydrophobic fraction both in concentration and reactivity.

Determination of soil water characteristic curve and permeability equation of unsaturated soils using modified triaxial apparatus (변형된 삼축시험장치를 이용한 불포화토의 함수특성곡선과 투수계수방정식의 결정)

  • Kim, Suk-Nam;Park, Chi-Won;Mok, Young-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.362-369
    • /
    • 2005
  • Studying unsaturated soil mechanics, determination of soil water characteristic curve and permeability equation is an essential factor but it is not easy. In this research a new testing apparatus was developed to determine soil water characteristic curve and permeability equation. The testing to get saturated permeability coefficients and soil water characteristic curves for two soils was performed by using the developed testing apparatus. First, a saturated permeability testing was performed and then the testing to get soil water characteristic curve of a drying process was performed. Next, the testing to get soil water characteristic curve of a wetting process was performed. Testing results showed hysteresis phenomena between soil water characteristic curve of a drying process and soil water characteristic curve of a wetting process. The permeability equations were determined by a theoretical method where a saturated permeability coefficient and a soil water characteristic curve were used.

  • PDF

Water Treatment Process for Removal of Free Ammonia in Bank Filtrated Water (암모니아성 질소제거를 위한 강변여과수에서의 수처리 공정)

  • Choo Tae-Ho;Lee Jung-Suk
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2005.11a
    • /
    • pp.123-128
    • /
    • 2005
  • Buk-myeon area in Changwon is located near Nakdong river and not short of quantity of river but the water quality and quantity is changed extremely by seasons, and Fe, Mn, Cu are found at the base rock underground water. Therefore, bank filtrated water developing is settled. At this research, Pilot-Plant is built to find out Fe and Mn are detected and eliminated by biological process and the ammonia is exceeded the drinking water quality criteria at the bank filtrated water while designing and facilitating the local water supply facilities at Buk-myeon area. Also, check results of the changed treatment process of automatic precipitating filter, which is producing and supplying drinking water, and analyzing the Biological Process Effectiveness by building and running Buk-myeon Water Treatment Facility, which could provide $10,000m^3/day$.

  • PDF

Basic study on development of drinking water treatment process simulators (정수처리공정 시뮬레이터 개발 기초연구)

  • Byun, Yong-Hoon;Shin, Hwi-Su;Kim, Ho-Yong;Jung, Nahm-Chung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.5
    • /
    • pp.351-365
    • /
    • 2021
  • Water treatment process simulator is the tool for predicting sequential changes of water quality in a train of unit processes. This predicts the changes through governing equations that represent physicochemical performance of each unit processes with an initial and boundary conditions. Since there is no operational data for the design of a water treatment facility, there is no choice but to predict the performance of the facility by assuming initial and boundary conditions in virtual reality. Therefore, a simulator that can be applied in the design stage of a water treatment facility has no choice but to be built as a numerical analysis model of a deductive technique. In this study, we had conducted basic research on governing equations, inter-process data-flow, and simulator algorithms for the development of simulators. Lastly, this study will contribute to design engineering tool development research in the future by establishing the water treatment theory so that it can be programmed in a virtual world and suggesting a method for digital transformation of the water treatment process.

Microstructure and Mechanical Properties of Hot-Stamped 3.2t Boron Steels according to Water Flow Rate in Direct Water Quenching Process (3.2t 보론강 판재 직수냉각 핫스탬핑시 냉각수 유량에 따른 미세조직 및 기계적 특성)

  • Park, Hyeon Tae;Kwon, Eui Pyo;Im, Ik Tae
    • Korean Journal of Materials Research
    • /
    • v.30 no.12
    • /
    • pp.693-700
    • /
    • 2020
  • Direct water quenching technique can be used in hot stamping process to obtain higher cooling rate compared to that of the normal die cooling method. In the direct water quenching process, setting proper water flow rate in consideration of material thickness and the size of the area directly cooled in the component is important to ensure uniform microstructure and mechanical properties. In this study, to derive proper water flow rate conditions that can achieve uniform microstructure and mechanical properties, microstructure and hardness distribution in various water flow rate conditions are measured for 3.2 mm thick boron steel sheet. Hardness distribution is uniform under the flow condition of 1.5 L/min or higher. However, due to the lower cooling rate in that area, the lower flow conditions result in a drastic decrease in hardness in some areas in the hot-stamped part, resulting in low martensite fraction. From these results, it is found that the selection of proper water flow rate is an important factor in hot stamping with direct water quenching process to ensure uniform mechanical properties.

MIXING PROCESS FLOW ANALYSIS OF PDM AND HYDRAULIC MIXING BASIN SYSTEM USING CFD (CFD를 이용한 펌프확산 및 수리낙차 방식의 혼화공정 흐름 분석)

  • Lee, S.W.;Chang, S.M.;Cho, Y.
    • Journal of computational fluids engineering
    • /
    • v.22 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • The mixing of water and chemicals is an important process in the water purification plant. In this paper, we compare PDM(pump diffusion mixer) and hydraulic mixer at the basin in the mixing process. The proper flow rates are predicted and compared in both mixers using CFD technique. As a result, the flow rate of purifier chemical liquid should be 5% of that of water for the optimal performance of mixing process. The characteristics of the two mixing methods are compared with each other for strong and weak points on the operation of the purification system, discussed in the view point of CFD simulations.

Models for drinking water treatment processes

  • Jusic, Suvada;Milasinovic, Zoran;Milisic, Hata;Hadzic, Emina
    • Coupled systems mechanics
    • /
    • v.8 no.6
    • /
    • pp.489-500
    • /
    • 2019
  • With drinking water standards becoming more rigorous and increasing demands for additional water quantities, while water resources are becoming more polluted, mathematical models became an important tool to improve water treatment processes performance in the water supply system. Water treatment processes models reflect the knowledge of the processes and they are useful tools for water treatment process optimization, design, operator training for decision making and fundamental research. Unfortunately, in the current practice of drinking-water production and distribution, water treatment processes modeling is not successfully applied. This article presents a review of some existing water treatment processes simulators and the experience of their application and indicating the main weak points of each process. Also, new approaches in the modeling of water treatment are presented and recommendations are given for the work in the future.