• Title/Summary/Keyword: process measurement

Search Result 5,167, Processing Time 0.029 seconds

An Empirical Study of the Analytical Measurement Range in Clinical Chemistry (분석측정범위의 실증적 평가)

  • Chang, Sang-Wu;Lee, Sang-Gon;Kim, Young-Hwan;Song, Eun-Young;Park, Yong-Won;Park, Byong-Ok;Lyu, Jae-Gi
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.38 no.2
    • /
    • pp.117-124
    • /
    • 2006
  • The analytical measurement range (AMR) is the range of analyte values that a method can directly measure on a specimen without any dilution, concentration, or other pretreatment not part of the usual assay process. The linearity of the AMR is its ability to obtain test results which are directly proportional to the concentration of analyte in the sample from the upper and lower limit of the AMR. The AMR validation is the process of confirming that the assay system will correctly recover the concentration or activity of the analyte over the AMR. The test specimen must have analyte values which, at a minimum, are near the low, midpoint, and high values of the AMR. The AMR must be revalidated at least every six months, at changes in major system components, and when a complete change in reagents for a procesure is introduced; unless the laboratory can demonstrate that changing the reagent lot number does not affect the range used to report patient test results. The AMR linearity was total protein (0-16.6), albumin (0-8.1), total bilirubin (0-18.1), alkaline phosphatase (0-1244.3), aspartate aminotransferase (0-1527.9), alanine aminotransferase (0-1107.9), gamma glutamyl transpeptidase (0-1527.7), creatine kinase (0-1666.6), lactate dehydrogenase (0-1342), high density lipoprotein cholesterol (0.3-154.3), sodium (35.4-309), creatinine (0-19.2), blood urea nitrogen (0.5-206.2), uric acid (0-23.9), total cholesterol (-0.3-510), triglycerides (0.7-539.6), glucose (0-672.7), amylase (0-1595.3), calcium (0-23.9), inorganic phosphorus (0.03-17.0), potassium (0.1-116.5), chloride (3.3-278.7). We are sure that materials for the AMR affect the evaluation of the upper limit of the AMR in the process system.

  • PDF

IN-LINE NIR SPECTROSCOPY AS A TOOL FOR THE CONTROL OF FERMENTATION PROCESSES IN THE FERMENTED MEATS INDUSTRY

  • Tamburini, Elena;Vaccari, Giuseppe;Tosi, Simona;Trilli, Antonio
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3104-3104
    • /
    • 2001
  • The research described here was undertaken with the aim of monitoring, optimizing and ultimately controlling the production of heterofermentative microbes used as starters in the salami industry. The use of starter cultures in the fermented meats industry is a well-established technique used to shorten and standardize the ripening process, and to improve and control the organoleptic quality of the final product. Starter cultures are obtained by the submerged cultivation of suitable microorganisms in stirred, and sometimes aerated, fermenters where monitoring of key physiological parameters such as the concentration of biomass, substrates and metabolites suffers from the general lack of real-time measurement techniques applicable to aseptic processes. In this respect, the results of the present work are relevant to all submerged fermentation processes. Previous work on the application of on-line NIR spectroscopy to the lactic acid fermentation (Dosi et al. - Monreal NIR1995) had successfully used a system based on a measuring cell included in a circulation loop external to the fermenter. The fluid handling and sterility problems inherent in an external circulation system prompted us to explore the use of an in-line system where the NIR probe is immersed in the culture and is thus exposed to the hydrodynamic conditions of the stirred and aerated fluid. Aeration was expected to be a potential source of problems in view of the possible interference of air bubbles with the measurement device. The experimental set-up was based on an in-situ sterilizable NIR probe connected to the instrument by means of an optical fiber bundle. Preliminary work was carried out to identify and control potential interferences with the measurement, in particular the varying hydrodynamic conditions prevailing at the probe tip. We were successful in defining the operating conditions of the fermenter and the geometrical parameters of the probe (flow path, positioning, etc.) were the NIR readings were reliable and reproducible. The system thus defined was then used to construct and validate calibration curves for tile concentration of biomass, carbon source and major metabolites of two different microorganisms used as salami starters. Real-time measurement of such parameters coupled with the direct interfacing of the NIR instrument with the PC-based measurement and control system of the fermenter enabled the development of automated strategies for the interactive optimization of the starter production process.

  • PDF

Standardization of work environment measurement information for constructing exposure surveillance system (노출감시체계 구축을 위한 작업환경측정 정보 표준화)

  • Choi, Sangjun;Jeong, Jee Yoen;Im, Sungguk;Lim, Daesung;Koh, Dong-Hee;Park, Donguk;Park, YunKyung;Kim, Soyeon;Chung, Eunkyo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.3
    • /
    • pp.322-335
    • /
    • 2019
  • Objectives: The goal of this study is to standardize industry, process, and job within work environment measurement information. Methods: We selected 180 work environment measurement reports on 30 industries from a database monitored from 2014 to 2016 by the Korea Industrial Health Association. Ten industrial hygienists, each with over five years of experience in measurement, conducted a primary standardization of 180 reports. Two professional industrial hygienists with more than 20 years of experience each reviewed and revised the results of the primary standardization. We also examined the validity on the usefulness of the standardized database by the two industrial hygienists. Results: The final standardization results were classified into eight major categories, 23 sub-major categories, 39 minor categories, 53 unit categories and 70 sub-unit categories in the Korean Standard Industrial Classification (KSIC) 10th revision. A total of 161 processes were standardized, and there were 148 processes with K2B codes. Standard job was coded into 13 job groups including operator, automobile maintenance, nurse, maintenance, manager, excavating machine operator, forklift driver, radiologist, clinical pathologist, signer, researcher, kitchen assistant, and concrete reinforcement ironworker. Conclusions: Although the standardized information in this study may be only a part of the total information, it can be useful for improvement of the K2B system. Additional research is needed for an ongoing clean-up of data in the K2B and re-calibration and reclassification of standard processes until the future national exposure monitoring system is fully established.

A Study on the Reliability and Validity of the Collection of the Ethnography Method of Service Experience Data - Focusing on I know You_AI Service - (서비스경험데이터의 에스노그라피 방식 수집에 대한신뢰성과 타당성 연구 - I know you_AI 서비스를 중심으로 -)

  • Ahn, Jinho;Lee, Jeungsun
    • Journal of Service Research and Studies
    • /
    • v.10 no.4
    • /
    • pp.43-55
    • /
    • 2020
  • Recently, as the importance of experience data increases, there are many attempts to deal with experience data from a data science perspective. In the case of approaching as a collection method of a quantitative survey method that seeks to quantify numerically such as big data, it is difficult to interpret the value of experience in a wide range, and it is relatively expensive and time consuming, and personal information infringement There is a limit to the analysis due to the risk of However, since ethnography, a procedure for collecting experience data based on qualitative research, is mainly carried out in the natural real environment of future customers from the perspective of users, it is possible to confirm the nature that customers face with a small sample. In addition, it is also easy to interpret the relational dimension of the empirical data. Although the ethnography method of collecting experiential data is economical and efficient, it is important to reduce errors in the collection process because the lack of scientific procedures for the data collection process can be a problem. It is important to secure the validity of whether the correct measurement tool is used for ethnography-based experiential data collection and to secure the reliability of the use of a valid measurement tool and method by accurately selecting the measurement target. From this point of view, it is necessary to verify the reliability of the research method that clearly selects the measurement target and secures the validity for the development of the correct measurement method and tool for the collection of ethnography experience data. Therefore, in this study, a verification study was conducted on the data and methodology cases of the'I know you_AI' service that analyzes the customer experience of self-employed based on the ethnography method of collecting experience data..

Development of Wireless Measurement System for Bridge Using PDA and Fiber Optical Sensor (PDA와 광섬유 센서를 이용한 교량의 무선계측 시스템 개발)

  • Kwak, Kae-Hwan;Hwang, Hae-Sung;Jang, Hwa-Sup;Kim, Woo-Jong;Kim, Hoi-OK
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.1 s.53
    • /
    • pp.88-96
    • /
    • 2009
  • This study proposes a wireless measurement system that is a new safety management system by using an FBG sensor and a PDA. The sensor part has many advantages of implementing a wireless measurement system, and the study emploies an FBG-LVDT sensor, FBG-STRAIN sensor, FBG-TEMP sensor, and FBG-ACC sensor, using FBG sensors. Also, the study show a configuration of a signal process system for operating a wireless transmission system of FBG sensors applied to the signal process system, and engrafted the cutting edge information technology industry in order to display from a remote distance using a PDA. In order to verify the applicability of the developed FBG sensors and wireless measurement monitoring system to the field, their accuracy, and usability, the study has conducted a static and dynamic test to a bridge in the field. The study made an assessment of service for the vibration of the bridge by applying dynamic data measured by an FBG-LVDT sensor and FBG-ACC sensor to Meister's curve and prepared methods for assessing the vibration of the bridge by proposing a standard of vibration limitation given the service of vibration of the bridge. As a follow up for this study, it would be necessary to set up an overall model for the standard of service assessment established in this study.

The Process Reference Model for the Data Quality Management Process Assessment (데이터 품질관리 프로세스 평가를 위한 프로세스 참조모델)

  • Kim, Sunho;Lee, Changsoo
    • The Journal of Society for e-Business Studies
    • /
    • v.18 no.4
    • /
    • pp.83-105
    • /
    • 2013
  • There are two ways to assess data quality : measurement of data itself and assessment of data quality management process. Recently maturity assessment of data quality management process is used to ensure and certify the data quality level of an organization. Following this trend, the paper presents the process reference model which is needed to assess data quality management process maturity. First, the overview of assessment model for data quality management process maturity is presented. Second, the process reference model that can be used to assess process maturity is proposed. The structure of process reference model and its detail processes are developed based on the process derivation approach, basic principles of data quality management and the basic concept of process reference model in SPICE. Furthermore, characteristics of the proposed model are described compared with ISO 8000-150 processes.

An Objective Image Quality Measurement Considering Skipped & Estimated Positions of Pixels in Image Scaling (영상 크기 변환에서 화소들의 생략 및 추정 위치를 고려한 객관적 영상 화질 측정)

  • Kim, Won-Hee;Moon, Kwang-Seok;Kim, Jong-Nam
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.8
    • /
    • pp.934-942
    • /
    • 2013
  • Image scaling is used for a variety of real-life applications. In order to evaluate the performance of transform functions, the image quality are compared together before and after processing. For the objective evaluation of the transform functions, the exact criterion of image quality is required, and various aspects approaches are practically performed. However, few researches have been conducted on image quality measurement considering the position of pixels that are skipped or newly generated in the process of the image scaling. Therefore this paper focuses on the objective image quality measurement for positions of skipped or estimated pixels in the image scaling. The proposed method generated new image quality measure considering the positional changes using a conventional measure and evaluated sensitivity about positional changes. Through this experiments, it is observed that conventional image quality measurement is definitely affected by positional changes of a skipped and estimated pixels. It is also confirmed that the proposed method is an objective criterion to represent image quality for positional changes of skipped or estimated pixels. The proposed method can be used as a criterion to evaluate the performance of image restoration or enhancement functions.

Evaluation of Human Factors for the Next-Generation Displays: A Review of Subjective and Objective Measurement Methods

  • Mun, Sungchul;Park, Min-Chul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.2
    • /
    • pp.207-215
    • /
    • 2013
  • Objective: This study aimed to investigate important human factors that should be considered when developing ultra-high definition TVs by reviewing measurement methods and main characteristics of ultra-high definition displays. Background: Although much attention has been paid to high-definition displays, there have been few studies for systematically evaluating human factors. Method: In order to determine human factors to be considered in developing human-friendly displays, we reviewed subjective and objective measurement methods to figure out the current limitations and establish a guideline for developing human-centered ultra-high definition TVs. In doing so, pros and cons of both subjective and objective measurement methods for assessing humans factors were discussed and specific aspects of ultra-high definition displays were also investigated in the literature. Results: Hazardous effects such as visually-induced motion sickness, visual fatigue, and mental fatigue in the brain caused by undesirable TV viewing are induced by not only temporal decay of visual function but also cognitive load in processing sophisticated external information. There has been a growing evidence that individual differences in visual and cognitive ability to process external information can make contrary responses after exposing to the same viewing situation. A wide vision, ultra-high definition TVs provide, can has positive and negative influences on viewers depending on their individual characteristics. Conclusion: Integrated measurement methods capable of considering individual differences in human visual system are required to clearly determine potential effects of super-high vision displays with a wide view on humans. All of brainwaves, autonomic responses, eye functions, and psychological responses should be simultaneously examined and correlated. Application: The results obtained in this review are expected to be a guideline for determining optimized viewing factors of ultra-high definition displays and accelerating successful penetration of the next-generation displays into our daily life.

A Study on Designing Method of Framework for NGN QoS Management (NGN 운용과정의 QoS 관리를 위한 프레임워크 설계방법)

  • Noh, Si-Choon;Bang, Kee-Chun
    • Journal of Digital Contents Society
    • /
    • v.9 no.1
    • /
    • pp.101-107
    • /
    • 2008
  • The level of transference of NGN is beginning as the operation of Access Gateway in korea at present, but NGN will keep developing continuously to the NGN integrated network until 2010. This research is finding the meaning and assignment of NGN QoS to deduct how to manage the control system and presenting the QoS control process and trial framework. The trial framework is the modeling of the QoS measurement metrics, the measurement time schedule, the section, hierarchy, instrument, equipment and method of measurement and the series of cycle & the methodology about analysis of the result of measurement. The objective standard of quality in communication service is guaranteed not by itself but by controlling and measuring continuously. Especially it's very important time to maintain the research about NGN QoS measurement and control because the big conversion of new network technology paradigm is now spreading.

  • PDF

Measurement and Validation of Infrared Signature from Exhaust Plume of a Micro-Turbo Engine (마이크로 터보 엔진 배기 플룸에서의 적외선 신호 측정 및 검증)

  • Gu, Bonchan;Baek, Seung Wook;Jegal, Hyunwook;Choi, Seongman;Kim, Won Cheol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.12
    • /
    • pp.1054-1061
    • /
    • 2016
  • Development of an accurate infrared signature (IR) measurement system is expected to contribute in the development of low observable technology and the spectroscopic analysis of electromagnetic radiation. Application of a spectroradiometer (SR) allows for the measurement of detailed infrared signature from the exhaust plume due to its own heat source. Establishment of a measurement system using a micro-turbo engine is intended to simulate the modelling of the aircraft plume. The engine was installed on a test stand to measure the engine performance. The IR signature was measured by placing the SR perpendicular to the axis line of the exhaust plume. Reference data from the blackbody were also measured to calibrate the raw data, and the infrared signature of the background was also measured for comparison with that of the plume. The calibrated spectral radiance was obtained through the data reduction process and the results were analyzed in specific bands. The experiments revealed that the measurement system established here showed sufficient performance for further comprehensive analysis.