• Title/Summary/Keyword: process measurement

Search Result 5,167, Processing Time 0.039 seconds

Utilizing 3D Laser Scanning Technology for Remodeling Work of Building Inside

  • Lee, Jin-Duk;Han, Seung-Hee;Lee, Jae-Bin
    • International Journal of Contents
    • /
    • v.5 no.3
    • /
    • pp.19-23
    • /
    • 2009
  • Laser scanning technology is a maturing measurement technology which is capable of obtaining 3D measurement data of objects with high-accuracy, high-resolution and in a short time. Laser scanners are used more and more as surveying instruments for various applications. This paper describes the procedure of 3D data acquirement using terrestrial LiDAR and section drawing extraction through a series of processing for remodeling the interior of a department building. Accurate drawings are needed for improvement construction of building interior. However if the design drawings of that time of construction work were lost or damaged or actual dimensions of drawings differ from those of design drawings, the interior should be resurveyed. In this study, the extraction process of interior plane figures were suggested through using laser scanning and related reverse engineering software

On Apparent Density and Flow Rate Measurement at Elevated Temperature for Powder Mixes Intended for Warm Compacting (온간성형용 분말의 고온 유동도와 겉보기 밀도 측정에 관하여)

  • Lee Jeong-Keun;Kim Soon-Wook
    • Journal of Powder Materials
    • /
    • v.13 no.1 s.54
    • /
    • pp.52-56
    • /
    • 2006
  • The aim of this work was to establish an optimal condition for determination of apparent density and flow rate for warm compacting powder. For this purpose it was evaluated uncertainty on them according to ISO Guide to the Expression of Uncertainty in Measurement. This evaluation example would be useful even in powder fluidity measurement at room temperature.

Development of a Concentration Measurement System for Pickling Line Control (산세라인 자동화를 위한 농도 측정 시스템 개발)

  • Park, Hyoung-Kuk;Lee, Jong-Hyun;Noh, Ill-Hwan
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.10
    • /
    • pp.891-895
    • /
    • 2013
  • This paper proposes the development of a new method for online analysis which measured acid concentration in a pickling line. Pickling is the most important step to remove surface scale layers and is strongly depending on the exactly controlled pickling liquor composition. Today, there is no feasible system available for the online control of pickling lines. Within this paper, new methods for online analysis of pickling liquors have been tested and implemented into an overall pickling process control tool. This method measured simultaneously the hydrochloric acid and iron ion concentration in a solution of hydrochloric acid by measuring the ultrasonic speed, the solution temperature, and the electrical conductivity. Experimental results showed excellent precision and the measurement error was ${\pm}2g/l$ compared with the neutralization titration measurement.

Implementation of OLED's Brightness Aging Measurement System (OLED의 노화에 따른 밝기 감쇠측정 시스템)

  • Yoon, Hyun-Don;Hong, Jeong
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.439-440
    • /
    • 2006
  • This paper presents precise measurement system for the lifetime of OLED. The proposed system collects the data for using voltage drop across the OLED Panels, and then the computer program makes an analysis of the data. In this process of measurement, the current across OLED material must be amplified because the current is very small. However, amplifying the current causes the amplification of noise. Therefore, the proposed system measures the current using an algorithm which minimizes the noise.

  • PDF

Accurate Measurement of Twist Angle for Analysis of Azimuthal Anchoring Energy and Rubbing Direction of LC Panels of IPS Mode

  • Baek, S.H.;Rho, B.G.;Oh, J.M.;Dong, W.S.;Yang, B.K.;Kim, J.S.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.531-533
    • /
    • 2007
  • A new method is developed for the measurement of twist angles of LC molecules in an LC panel with angular resolution of 0.01degree, which allows measurement of LC panels with small twist angles. The method is based on the analysis of the change in polarization state of a light beam as it passes through the LC panel in test is rotated in-plane. Compared to other traditional method, including the analysis of transmittance change, our method is more sensitive and more precise. This method allows accurate determination of anchoring energy and close analysis of the rubbing process in the fabrication of IPS mode LC panels.

  • PDF

The Measurement System of Space Charge Distribution in Polymer Dielectric Materials by the PEA Method (펄스정전응력법(PEA)을 이용한 고분자 유전체 내의 공간전하분포 측정시스템)

  • Hwang, Bo-Seung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.6
    • /
    • pp.1403-1411
    • /
    • 2012
  • In this paper, we have evaluated theoretically the PEA method which is the most popular methods for the non-destructive measurement of space charge distribution in polymer dielectric materials and is recently one of big issues in DC high voltage cables. On the basis of theoretical evaluation, we have developed the space charge measurement system in polymer dielectrics under DC appled voltage and improved the accuracy of space charge distribution by applying the deconvolution process for distorted signals.

A Method of Wood Section Measuring and the Image Calibration Using Line Laser (Line Laser 를 이용한 목재단면 측정 및 영상보정 방법)

  • Kim, Gi Hwan;Park, Min Su;Kim, Do Yeop;Lee, Suk Yong;Lee, Eung Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.8
    • /
    • pp.641-646
    • /
    • 2016
  • The best method of measuring wood diameter is a contact-type device: however, obtaining an accurate result can be problematic under certain circumstances. In this study, we used a laser beam and a CCD camera that did not require contact with wood. The wood is illuminated by the laser beam, and the CCD camera captures this illumination. The measurement results were determined by processing of the captured image sequences. This paper explains the use of image processing and laser systems for measurement of wood under circumstances in which physical contact is impossible.

Learning City Performance Measurement and Performance Measure Weighting Decision based on DEA Method (DEA를 활용한 성과평가 지표의 가중치 결정모형 구축 : 평생학습도시 성과평가 지표 적용 사례를 중심으로)

  • Lim, Hwan;Sohn, Myung-Ho
    • Journal of Information Technology Services
    • /
    • v.9 no.4
    • /
    • pp.109-121
    • /
    • 2010
  • Most organizations adopt their own performance measurement systems. Those organizations select performance measures to meet their goals. Organizations can give only limited description of what performance measures are. Kaplan and Norton suggest that the Balanced Scorecard (BSC) to complement the conventional performance measures. The BSC can provide management system with a comprehensive strategic vision and integrates non-financial measures with financial measures. The BSC is widely used for measuring corporate performance. This paper investigates how the BSC-based performance measures can be applied to Learning City. The Learning City's performance measures and strategy map on the basis of the BSC are suggested in this research. This paper adopt the AR(assurance region)-DEA model which could limit the range of weight on performance measures to prevent each viewpoint of BSC from having unlimited elasticity. The proposed model is based on CCR model including a property of unit invariance to use the data without normalization process.

PCB Integrated Spiral Pattern Pick-up Coil Current Measurement Scheme with High Sensitivity for WBG Devices (WBG 소자를 위한 높은 측정 감도를 가지는 PCB 내장형 Spiral 패턴 Pick-up Coil 전류 측정 기법)

  • Kim, Kyeong-Mo;Cha, Hwa-Rang;Kim, Rae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.3
    • /
    • pp.162-170
    • /
    • 2020
  • In this paper, we report our study of the current measuring technique by implementing a pick-up coil in the PCB pattern instead of the current measuring sensor in a power converter using a WBG device. The proposed PCB pattern coil structure has a higher mutual inductance value than the conventional pattern by constructing the coil using the multi layer board. It has high sensitivity and is configured without additional process outside the PCB. In the current measurement, the integrator is measured by integrating the coil at the back end and the current waveform measured using proposed pick-up coil is confirmed by comparing it with the original current waveform through DPT simulation.

The Implementation of A Therapy Radiation Dose Measurement System Using A Microcomputer (마이크로컴퓨터를 이용한 치료방사선 선량측정 시스템의 구현)

  • Lee, D.H.;Kwon, O.S.;Hong, J.P.;Chae, C.S.;Hong, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.15-17
    • /
    • 1996
  • In this paper, the therapy radiation dose measurement system has been implemented by using a microcomputer after radiation was irradiated on diodes from the MM22 microtron accelerator. We have displayed 7-channel diode output values on the LCD after processing those in the 80196 MCU(Micro Computer Unit). Signal processing has been performed in the pulse mode because we can process the signal fast and use it to perform portal image by increasing a number of diode channels in the future. In order to verify the microcomputer based radiation measurement system of diodes, diode output values were compared with that of semiconductor.

  • PDF