Lead Exposure Status of Smelt Process Workers in Steelmaking using Scrap Iron (제강공장 고철 용해공정 근로자의 납 노출실태)

  • Gu, Dongchul;Lee, Jaehwan;Han, Areum;Kim, Hyunju;Lee, Suyeon;Yun, Soonyoung;Lee, Chae Kwan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.2
    • /
    • pp.164-168
    • /
    • 2013
  • Objectives: This study was aimed at the examination of the lead exposure status of smelting process workers in steelmaking using scrap iron. Methods: The study was conducted from July to September 2012 by means of measurements taken during the smelting process, with 45 minutes set for a one-time smelting work cycle when it comes to personal air sample and area air sample. As such, daily work hours were classified into 360 minutes for measurement. The analysis of lead concentration was conducted using AAs based on the NIOSH 7300 method. Results: In the case of the personal specimens that were subjected to periodical measurement 45 minutes per one session during the smelting process, 40 out of 42 specimens measured were found to contain lead, with an average concentration level of $0.028mg/m^3$ (Max: $0.182mg/m^3$, Min: $0.005mg/m^3$, TWA-more than 50%: 4 out of 6 units). In the case of regional specimens, lead was detected in 45 out of 48 specimens measured, with an average concentration level of $0.037mg/m^3$ (Max: $0.220mg/m^3$, Min: $0.007mg/m^3$ ). In the case of regional specimens subjected to measurement using a day as the work cycle, lead was detected in 15 out of 15 specimens measured, with an average concentration level of $0.049mg/m^3$ (Max: $0.478mg/m^3$, Min: $0.005mg/m^3$ ). Conclusions: It concluded that smelting process workers in steelmaking are exposed to lead because scrap iron is used as a raw material. It is thus necessary to introduce legal management to prevent occupation-related disease in smelting process workers in steelmaking.

Thermally Stimulated Current Analysis of (Ba, Sr)TiO$_3$ Capacitor ((Ba, Sr)TiO$_3$ 커패시터의 Thermally Stimulated Current분석)

  • Kim, Yong-Ju;Cha, Seon-Yong;Lee, Hui-Cheol;Lee, Gi-Seon;Seo, Gwang-Seok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.5
    • /
    • pp.329-337
    • /
    • 2001
  • It has been known that the leakage current in the low field region consists of the dielectric relaxation current and intrinsic leakage current, which cause the charge loss in dynamic random access memory (DRAM) storage capacitor using (Ba,Sr)TiO$_{3}$ (BST) thin film. Especially, the dielectric relaxation current should be seriously considered since its magnitude is much larger than that of the intrinsic leakage current in giga-bit DRAM operation voltage (~IY). In this study, thermally stimulated current (TSC) measurement was at first applied to investigate the activation energy of traps and relative evaluation of the density of traps according to process change. And, through comparing TSC to early methods of I-V or I-t measurement and analyzing, we identify the origin of the dielectric relaxation current and investigate the reliability of TSC measurement. First, the polarization condition such as electric field, time, temperature and heating rate was investigated for reliable TSC measurement. From the TSC measurement, the energy level of traps in the BST thin film has been investigated and evaluated to be 0.20($\pm$0.01) eV and 0.45($\pm$0.02) eV. Based on the TSC measurement results before and after rapid thermal annealing (RTA) process, oxygen vacancy is concluded to be the origin of the traps. TSC characteristics with thermal annealing in the MIM BST capacitor have shown the same trends with the current-voltage (I-V) and current-time (I-t) characteristics. This means that the TSC measurement is one of the effective methods to characterize the traps in the BST thin film.

  • PDF

Development of the Aircraft CO2 Measurement Data Assimilation System to Improve the Estimation of Surface CO2 Fluxes Using an Inverse Modeling System (인버스 모델링을 이용한 지표면 이산화탄소 플럭스 추정 향상을 위한 항공기 관측 이산화탄소 자료동화 체계 개발)

  • Kim, Hyunjung;Kim, Hyun Mee;Cho, Minkwang;Park, Jun;Kim, Dae-Hui
    • Atmosphere
    • /
    • v.28 no.2
    • /
    • pp.113-121
    • /
    • 2018
  • In order to monitor greenhouse gases including $CO_2$, various types of surface-, aircraft-, and satellite-based measurement projects have been conducted. These data help understand the variations of greenhouse gases and are used in atmospheric inverse modeling systems to simulate surface fluxes for greenhouse gases. CarbonTracker is a system for estimating surface $CO_2$ flux, using an atmospheric inverse modeling method, based on only surface observation data. Because of the insufficient surface observation data available for accurate estimation of the surface $CO_2$ flux, additional observations would be required. In this study, a system that assimilates aircraft $CO_2$ measurement data in CarbonTracker (CT2013B) is developed, and the estimated results from this data assimilation system are evaluated. The aircraft $CO_2$ measurement data used are obtained from the Comprehensive Observation Network for Trace gases by the Airliner (CONTRAIL) project. The developed system includes the preprocessor of the raw observation data, the observation operator, and the ensemble Kalman filter (EnKF) data assimilation process. After preprocessing the raw data, the modeled value corresponding spatially and temporally to each observation is calculated using the observation operator. These modeled values and observations are then averaged in space and time, and used in the EnKF data assimilation process. The modeled values are much closer to the observations and show smaller biases and root-mean-square errors, after the assimilation of the aircraft $CO_2$ measurement data. This system could also be used to assimilate other aircraft $CO_2$ measurement data in CarbonTracker.

Measurement of Dynamic Deformation for Structure Using Linear Scan Sensor (Linear Scan Sensor를 활용한 구조물 동적 변위 측정)

  • 김감래;김명배;곽강율;김주용
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.10a
    • /
    • pp.39-42
    • /
    • 2003
  • In order to Impose an effective check on the existing methode of measurement, this study make an attempt to attach sensor on a structure, which can perceive a laser beam sent out from a light source at any place. This system makes it possible to measure an absolute of dynamic displacement according to accurately survey an amount of fluctuation in process of time. This result of experiment to compare the products by means of each method was satisfactory for identification. Accordingly these facts attest to the possibility of accurate measurement owing to gauge an dynamic displacement amount of structure.

  • PDF

Measurement Technique for Sea Height of Burst Using Image Recognition

  • Park, Ju-Ho;Hong, Sung-Soo;Kang, Kyu-Chang;Joon Lyou
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.2 no.1
    • /
    • pp.76-83
    • /
    • 2000
  • A measurement technique of a sea height of burst is introduced for a proximate test using the image recognition of video cameras. In the burst of fuse on the ocean, the burst center of fuse, the sea surface level and the height of calibration poles are measured by the process of image obtained from cameras. Finally, the height of burst of fuse can be computed by Hough transform algorithm. The error compensation algorithms are proposed to eliminate the errors caused by camera level and environmental parameters. As a result of experiment, it has been proved that the proposed measurement system shows the recognition of the center point of the burst image with ${\pm}$0.5m error.

  • PDF

Measurement of Crystal Formation in Supersaturated Solution

  • Kim, Byung-Chul;Kim, Young-Han
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1196-1200
    • /
    • 2003
  • The degree of supersaturation is an important measure for the operation of crystallization processes, because it is directly related to the control of crystal size distribution and shape. A conventional technique utilizing solution composition and temperature has a variety of problems caused from the measurement error and the handling of analyzing samples. A monitoring system of the supersaturation using a quartz crystal sensor is proposed here, and its performance is examined applying different manipulations of coolant temperature. The experimental outcome and photographic examination indicate that the measurements of resonant frequency and resistance of the sensor can be used for the prediction of the formation and growth of solid crystal from the crystallization process. The monitoring system eliminates the intrinsic error source of the conventional system to give the improved measurement and on-line application availability.

  • PDF

Development of Precise Measuring System for Hot Strip Mill's Rolls (열간압연용 롤 정밀 측정시스템 개발)

  • 이성진;이영진
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.614-618
    • /
    • 2002
  • In hot strip mills, Portable Roll Scanner (the portable roll surface temperature and profile measuring device) can be used to calibrate on-line Process models for strip crown and flatness by measuring the thermal expansion and wear profile of the rolls. And the surface temperature measurement can be used to optimize the roll cooling system. Portable Roll Scanner consists of the measuring device, which has two contact inductive distance transducers for roll profile measurement and one infrared Pyrometer for surface temperature measurement, and computer-based controller that is equipped with the measuring device. By the wireless data communication, the data is transferred to the memory of notebook for further analysis. After roll extraction from mills, Portable Roll Scanner measure the roll profile and surface temperature simultaneously along the work roll face and display the results in the TFT color monitor of notebook. Portable Roll Scanner is useful at mill-side and roll grinding shop.

  • PDF

Monitoring of Grinding Processes by Using On-the-machine Measurement of Surface Roughness (기상에서의 표면 거칠기 측정에 의한 연삭 공정 모니터링)

  • Kim, Hyun-Soo;Hong, Seong-Wook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.1 s.94
    • /
    • pp.167-173
    • /
    • 1999
  • This paper presents results of monitoring grinding processes with on-the-machine measurement of surface roughness by using nux ratios of scattered lights. A compact, on-the-machine surface roughness sensor. which consists of a diodelaser and several optic units. is developed. The control unit is also developed. The developed sensor together with the controller is applied for monitoring grinding processes of two different grinding machines. Experimental results show that the nux ratios and their standard deviations measured by the developed sensor over the entire ground surface are useful for monitoring grinding conditions. In particular, the sensor and the control unit are proved to be useful for monitoring grinding processes in order to detect abnormal grinding conditions and dressing time.

  • PDF

A Study on the Parameter Measurement of Three Phase Brushless DC Moto (삼상 브러시리스 직류전동기의 파라미터 측정에 관한 연구)

  • 임영철;장영학;조경영;정영국
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.5 no.3
    • /
    • pp.54-63
    • /
    • 1991
  • This paper describes an effort to develope a microcomputer-based parameter measurement system for a brushless DC motor. Back EMF equation is derived from back EMF waveform of a brushless DC motor. To minimize error the due to the ripple component in the measured armature current, digital averaging filter is employed. The whole identification process of signal generation, measurement parameter determination is fully automated. A new identification algorithm for the brushless DC motor parameters is developed. New parameter correction method is proposed using the deadzone current and the time to reach the peak current. In the proposed correction method, the measured current is in excellent agreement with the estimated current.

  • PDF

Development of Measurement and Evaluation Technique for Software Quality in Design Phase (설계단계에서의 소프트웨어 품질측정과 평가기법 개발)

  • 장영숙;권영식
    • Journal of Korean Society for Quality Management
    • /
    • v.27 no.3
    • /
    • pp.94-112
    • /
    • 1999
  • It is booming to use computer and information owing to the information society. As software applications have grown, so too has the importance of software quality. Therefore, software quality measurement and evaluation are necessary to satisfy the users who are using computers. The ISO/IEC 9126 defines six quality characteristics and twenty-one subcharacteristics including forty inter quality characteristics. We developed software measurement and evaluation technique using the check list in accordance with the ISO/IEC 9126 in design phase. We applied idea and concept of Total Quality Management in order to evaluate and measure the quality of software. Namely, it is the concept such as "you should do it right the first time." or "you have to build quality in the process." We executed the quantitative evaluation of software, also had shown the distinctive result in order that users and developers can find the errors easily. We evaluated the quality of academic softwares in order to verify developing technique at S college. As a result of the evaluation, this college has found it necessary to maintain the software as soon as possible because academic systems are not adequate for users at this present time.