• Title/Summary/Keyword: process measurement

Search Result 5,167, Processing Time 0.033 seconds

Method for Measuring Usability of Smart Television (스마트TV의 사용성 측정방법)

  • Byun, Dae-Ho
    • Journal of Digital Convergence
    • /
    • v.11 no.5
    • /
    • pp.31-39
    • /
    • 2013
  • Smart TV is a television set with internet capabilities, computing ability, and broadcasting service that increases user interactions. Usability has been regarded as one of the most important criteria for measuring and evaluating smart TV. To evaluate smart TV from the perspective of usability, we first need to develop a measurement model by determining the major factors affecting usability, which become a measurement the evaluation criteria of the model. The objective of this paper is to suggest an AHP(Analytic Hierarchy Process) model for measuring usability of smart TV. Factors affecting usability are described from the prior research. We show how the judgment data is acquired and the usability score is computed by an numerical example.

Synthesis of FDR-SPC Resin and PIV Measurement for Frictional Drag-reduction (마찰저항 저감을 위한 고분자 수지 합성 및 PIV 유동장 계측)

  • Chung, Sungwoo;Kim, Eunyoung;Chun, Ho Hwan;Park, Hyun;Lee, Inwon
    • Journal of the Korean Society of Visualization
    • /
    • v.12 no.1
    • /
    • pp.49-53
    • /
    • 2014
  • In this study, a novel FDR-SPC is first synthesized in this study. The drag reducing functional radical such as PEGMA (Poly(ethylene) glycol methacrylate) has been utilized to participate in the synthesis process of the SPC. The types of the baseline SPC monomers, the molecular weight and the mole fraction of PEGMA were varied in the synthesis process. The resulting SPCs were coated to the substrate plates for the subsequent hydrodynamic test for skin friction measurement. In a low-Reynolds number flow measurement using PIV (Particle Image Velocimeter), a significant reduction in Reynolds stress was observed in a range of specimen, with the maximum drag reduction being 15.9% relative to the smooth surface.

Generating Cartesian Tool Paths for Machining Sculptured Surfaces from 3D Measurement Data (3차원 측정자료부터 자유곡면의 가공을 위한 공구경로생성)

  • Ko, Byung-Chul;Kim, Kwang-Soo
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.19 no.3
    • /
    • pp.123-137
    • /
    • 1993
  • In this paper, an integrated approach is proposed to generate gouging-free Cartesian tool paths for machining sculptured surfaces from 3D measurement data. The integrated CAD/CAM system consists of two modules : offset surface module an Carteian tool path module. The offset surface module generates an offset surface of an object from its 3D measurement data, using an offsetting method and a surface fitting method. The offsetting is based on the idea that the envelope of an inversed tool generates an offset surface without self-intersection as the center of the inversed tool moves along on the surface of an object. The surface-fitting is the process of constructing a compact representation to model the surface of an object based on a fairly large number of data points. The resulting offset surtace is a composite Bezier surface without self-intersection. When an appropriate tool-approach direction is selected, the tool path module generates the Cartesian tool paths while the deviation of the tool paths from the surface stays within the user-specified tolerance. The tool path module is a two-step process. The first step adaptively subdivides the offset surface into subpatches until the thickness of each subpatch is small enough to satisfy the user-defined tolerance. The second step generates the Cartesian tool paths by calculating the intersection of the slicing planes and the adaptively subdivided subpatches. This tool path generation approach generates the gouging-free Cartesian CL tool paths, and optimizes the cutter movements by minimizing the number of interpolated points.

  • PDF

A Study on Photoelastic Fringe Patterns in Cutting Proces(I) (切削加工 의 光彈性的 現象 에 관한 硏究( I ))

  • 김정두;이용성
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.7 no.2
    • /
    • pp.161-167
    • /
    • 1983
  • In this study the phenomenon of cutting stress which arises on cutting tools and work pieces in cutting process is investigated by rake angle of cutting tools and feed for this measurement, P$_{s}$-1 (high modulus, photolastic Inc.) was used as a cutting tool, P$_{s}$-3 (medium modulus, photolastic Inc.) was used as work piece and reduction apparatus was attached to the head stock, and orthogonal cutting was adapted as a cutting method and transparent glass was used to block the strain in the orientation of thickness. The followings are the results of this study. (1) Photoelastic experimental equipments have made it possible to make dynamic measurement and analyze stress distribution in cutting tool and work piece surface which has hitherto been conducted only in static measurement and analyzing method. (2) The maximum stress arising at tools and work pieces in cutting process is on the tool edge tip, and the maximum stress arising on the tip of cutting tools is equal to that on the contacting area of work pieces in values. (3) The distributions of maximum shear stress on certain parts of the cutting tools and work pieces are as follows; for cutting tools, .alpha.=12.deg., .alpha.=0.deg., .alpha.=-12.deg. in order, and for work pieces, .alpha.=-12.deg., .alpha.=0.deg., .alpha.=12.deg. in opposite order.der.

Automatic Color Recognition System for Stockigt Sizing Test (I) - Bias of Stockigt sizing test based on observer's subjectiveness - (스테키히트 시험용 자동 발색 인지 시스템 개발을 위한 기초연구(I) - Stockigt 사이즈도 시험법에 영향을 주는 요인 분석 -)

  • 김재옥;김철환;박종열
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.36 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • One of the most frequently used method for measurement of the degree of sizing (viz., hydrophobicity) is the Stockigt test. However, the Stockigt test was influenced by various factors such as dropping height, dropping amount, dropping speed and viewing angle. The resultant data of the sizing degree on the same specimen also varied according to different testers. Thus, the Stockigt test should be modified to be regarded as a highly reliable and reproducible standard method. For modifying the Stockigt test, it was required to quantify red coloration by reaction between 1% ferric chloride and 2% ammonium thiocyante during Stockigt testing. The cameras capturing the serial images during the red coloration process were the CMOS (Complementary Metal Oxide Semiconductor)-type and CCD (Charge Coupled Device)-type cameras. For measurement based on KS M 7025, the CCD-type camera must be used due to its high resolution, and on the other hand, for measurement based on Tappi Useful Method 429, the CMOS-type camera may be used owing to its low resolution. It was needed to covert the RGB values of a droplet image into HSV(Hue, Saturation, and Value) values because the human eyes are much closer to HSV than RGB. Among HSV values, the Hue value was accepted as the most reliable index consistent with the red coloration process by excluding the surrounding conditions such as light, tester's movement etc.

Measurement of Public Research Outcomes: A Technology Valuation Method

  • Park, Jung-Min;Lim, Seong-Il;Seol, Sung-Soo
    • Asian Journal of Innovation and Policy
    • /
    • v.6 no.2
    • /
    • pp.206-224
    • /
    • 2017
  • This article proposes a logic model for assessing the performance of the outcome of public research as a technology valuation method. It consists of two parts and eight steps. The first part is a scoring system and the second part is a validation process of the performance index derived from scoring by valuation method. The scoring in the first part generally requires a focus group method to find out the value drivers and make an evaluation table. The reason why we call it the technology valuation method is that the first part is derived from the simple evaluation of technology value using checklists for value drive. The second part is the regular technology valuation process. The model is designed for the measurement of unquantifiable outcome. Is knowledge or scientific outcome comparable to the measured outcome? If possible, how big is the unquantifiable outcome? This model is based on financial valuation techniques with clear or acceptable market data. Therefore, it cannot work solely for unquantifiable outcomes without comparable measurable outcomes, unlike economic valuation.

A Study on the Performance Indicators of SME's International Marketing Program (중소기업 수출역량강화사업의 성과지표에 관한 연구)

  • Han, Min-Chung;Ahn, Byung-Soo
    • International Commerce and Information Review
    • /
    • v.16 no.3
    • /
    • pp.141-158
    • /
    • 2014
  • This research is intended to improve the performance of "small and medium companies international marketing program" by screening the performance indicators of the program. The program aims to prepare SMEs to penetrate foreign market and become global companies eventually. This research analyzed the current SMEs international marketing programs based on Logic Model to find the current performance measurement lacks in qualitative indicators and process evaluation with focusing on quantitative indicators and short term result evaluation. Therefore, the measurement indicators should be balanced between process and results including mid-term and long term results.

  • PDF

Minimum Pollution of Silicate Oxide in the CMP Process (CMP공정에 의한 실리케이트 산화막의 오염 최소화)

  • Lee, Woo-Sun;Kim, Sang-Yang;Choi, Gun-Woo;Cho, Jun-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.171-174
    • /
    • 2000
  • We have investigated the CMP slurry properties of silicate oxide thin films surface on CMP cleaning process. The metallic contaminations by CMP slurry were evaluated in four different oxide films, such as plasma enhanced tetra-ethyl-ortho-silicate glass(PE-TEOS), $O_3$ boro-phospho silicate giass( $O_3$-BPSG), PE-BPSG, and phospho-silicate glass(PSG). All films were polished with KOH-based slurry prior to entering the post-CMP cleaner. The Total X-Ray Fluorescence(TXRF) measurements showed that all oxide surfaces are heavily contaminated by potassium and calcium during polishing, which is due to a CMP slurry. The polished $O_3$-BPSG films presented higher potassium and calcium contaminations compared to PE-TEOS because of a mobile ions gettering ability of phosphorus. For PSG oxides, the slurry induced mobile ion contamination increased with an increase of phosphorus contents.

  • PDF

Indirect Method for Measurement of Tool Edge Roughness in flat End Mill (평 엔드밀 공구인선부 조도의 간접적인 측정법)

  • Kim, Jeon-Ha;Gang, Myeong-Chang;Kim, Jeong-Seok
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.10
    • /
    • pp.92-98
    • /
    • 2002
  • End mill is an essential tool to generate complex surface in workpiece and it has been developed with various materials and tool shapes. The most important factor to evaluate the performance of end mill is still the wear characteristics of flank face. In addition to the flank wear, the tool edge roughness generated by the chipping is another important factor in aspects of material property and machinability evaluation and affects the quality of machined surface. Up to now, there is no direct method for measurement of tool edge roughness. In this study, the tool edge roughness of flat end mill is indirectly measured along the axial direction of workpiece. The theoretical equation is derived in consideration of tool geometry. Finally, the optimal conditions to measure the tool edge roughness by the proposed method are presented through the theoretical review and experimental identification.

Development of a Transmission Error Measurement System and Its Adaptation to a Manufacturing Line (기어 전달오차 측정 시스템의 개발 및 라인 적용에 관한 연구)

  • Lee, Hyun Ku;Lee, Sang Hwa;Ku, Han Il;Yoo, Dong Kyu;Won, Kwang Min;Lee, Tae Hwi
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.4
    • /
    • pp.420-427
    • /
    • 2016
  • Diverse research on gearing systems have been made to resolve gear NVH problems for many decades, and transmission error (T.E.) has been identified as one of the main sources generating gear noises. While gear profiles and amounts of tooth modifications have influences on gear noise in the design aspect, it is found that bad manufacturing conditions such as burrs, bumps and damage, which result in improper gear operating conditions, produce gear noise with respect to manufacturing process. In this paper, T.E. measurement system was introduced to examine the gears damaged or improperly manufactured, while they are assembled, by comparing T.E. values and various gear conditions with theoretical ones. This T.E. measurement system, following grinding machining process, has been installed in a manufacturing line in 2014, and it results that the transmission rework to resolve manufacturing problems is not needed at the end of line.