• Title/Summary/Keyword: process measurement

Search Result 5,167, Processing Time 0.033 seconds

A Convergency Study on the Gas Turbine Rotation Axis Temperature Sensor for Power Plants (발전소용 가스터빈 회전축 온도 센서 융합연구)

  • Lee, Jeongl-Ick;Na, Gi-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.12
    • /
    • pp.293-298
    • /
    • 2019
  • The global market for temperature sensors for power plants is estimated at around 35 billion won, of which South Korea relies on imported products for more than 95 percent. This study is that a temperature measurement device for gas turbine rotators for power plants and can be applied to more than 800 of 100 MW gas turbine generators operating in Korea. This study has improved durability by changing the shape of the measuring part, structure of the connecting part, and material changes, and is a component technology applicable to other measuring devices such as humidity, gas and hydraulic pressure used in precision chemical process and plant export industry. As a result of this study, temperature sensors designed as three types of sensors for measuring the temperature of the gas turbine for power plants met Class 1 temperature accuracy in the range of 0℃ to 300℃, and improved durability significantly compared to similar products.

Design of the 1.9-GHz CMOS Ring Voltage Controlled Oscillator using VCO-gain-controlled delay cell (이득 제어 지연 단을 이용한 1.9-GHz 저 위상잡음 CMOS 링 전압 제어 발진기의 설계)

  • Han, Yun-Tack;Kim, Won;Yoon, Kwang-Sub
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.4
    • /
    • pp.72-78
    • /
    • 2009
  • This paper proposes a low phase noise ring voltage controlled oscillator(VCO) with a standard $0.13{\mu}m$ CMOS process for PLL circuit using the VCO-gain-controlled Delay cell. The proposed Delay cell architecture with a active resistor using a MOS transistor. This method can reduced a VCO gain so that improve phase noise. And, Delay cell consist of Wide-Swing Cascode current mirror, Positive Latch and Symmetric load for low phase noise. The measurement results demonstrate that the phase noise is -119dBc/Hz at 1MHz offset from 1.9GHz. The VCO gain and power dissipation are 440MHz/V and 9mW, respectively.

Latch-Up Prevention Method having Power-Up Sequential Switches for LCD Driver ICs (LCD 구동 IC를 위한 Power-Up 순차 스위치를 가진 Latch-Up 방지 기술)

  • Choi, Byung-Ho;Kong, Bai-Sun;Jun, Young-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.6
    • /
    • pp.111-118
    • /
    • 2008
  • In this paper, novel latch-up prevention method that employs power-up sequential switches has been proposed to relieve latch-up problem in liquid crystal display (LCD) driver ICs. These sequential switches are inserted in the 2'nd and 3'rd boosting stages, and are used to short the emitter-base terminals of parasitic p-n-p-n circuit before relevant boosting stages are activated during power-up sequence. To verily the performance of the proposed method, test chips were designed and fabricated in a 0.13-um CMOS process technology. The measurement results indicated that, while the conventional LCD driver If entered latch-up mode at $50^{\circ}C$ accompanying a significant amount of excess current, the driver IC adopting the proposed method showed no latch-up phenomenon up to $100^{\circ}C$ and maintained normal current level of 0.9mA.

Development of Long Term Flow Duration Curves for the Management of Total Maximum Daily Loads - in the Nakdong River Basin - (수질오염총량관리 단위유역 장기유황곡선 구축 -낙동강수계를 대상으로-)

  • Kim, Gyeong hoon;Kwon, Heon gak;Ahn, Jung min;Kim, Sanghun;Im, Tae hyo;Shin, Dong seok;Jung, Kang-Young
    • Journal of Environmental Science International
    • /
    • v.26 no.8
    • /
    • pp.939-953
    • /
    • 2017
  • For the development of flow duration curves for the management of 41 Total Maximum Daily Load (TMDL) units of the Nakdong River basin, first, an equation for estimating daily flow rates as well as the level of correlation (correlation and determination coefficients) was extrapolated through regression analysis of discrete (Ministry of Environment) and continuous (Ministry of Land, Infrastructure and Transportation) measurement data. The equation derived from the analysis was used to estimate daily flow rates in order to develop flow duration curves for each TMDL unit. By using the equation, the annual flow duration curves and flow curves, for the entire period and for each TMDL unit of the basin, were developed to be demonstrated in this research. Standard flow rates (abundant-, ordinary-, low- and drought flows) for major flow duration periods were calculated based on the annual flow duration curves. Then, the flow rates, based on percentile ranks of exceedance probabilities (5, 25, 50, 75, and 95%), were calculated according to the flow duration curves for the entire period and are suggested in this research. These results can be used for feasibility assessment of the set values of primary and secondary standard flow rates for each river system, which are derived from complicated models. In addition, they will also be useful for the process of implementing TMDL management, including evaluation of the target level of water purity based on load duration curves.

The TDDB Characteristics of Thin $SiO_2$ with Stress Voltage Polarity (스트레스전압 극성에 따른 얇은 산화막의 TDDB 특성)

  • Kim, Cheon-Soo;Yi, Kyoung-Soo;Nam, Kee-Soo;Lee, Jin-Hyo
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.5
    • /
    • pp.52-59
    • /
    • 1989
  • The reliability of the thin thermal oxide was investigated by using constant current stress method. Polysilicon gate MOS capacitors with oxide thickness range of 20-25nm were used in this experiment. Automatic measurement and statistical data analysis which were essential in reliability evaluation of VLSI process preformed by HP 9000 computer. Based on TDDB results, defect density, breakdown charge (Qbd) and lifetime of oxide film were evaluated. According to the polarity of the stress, some different characteristics were shown. Defect density was 62/$cm^2$ at negative gate injection. The value of Qbd was about 30C/$cm^2$ at positive gate injection, and about 21C/$cm^2$ at negative. The current density acceleration factor was 1.43$cm^2$/A for negative gate injection, and 1.25$cm^2$/A for positive gate injection.

  • PDF

3D Display Method for Moving Viewers (움직이는 관찰자용 3차원 디스플레이 방법)

  • Heo, Gyeong-Mu;Kim, Myeong-Sin
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.37 no.4
    • /
    • pp.37-45
    • /
    • 2000
  • In this paper we suggest a method of detecting the two eyes position of moving viewer by using images obtained through a color CCD camera, and also a method of rendering view-dependent 3D image which consists of depth estimation, image-based 3D object modeling and stereoscopic display process. Through the experiment of applying the suggested methods, we could find the accurate two-eyes position with the success rate of 97.5% within the processing time of 0.39 second using personal computer, and display the view-dependent 3D image using Fl6 flight model. And through the similarity measurement of stereo image rendered at z-buffer by Open Inventor and captured by stereo camera using robot, we could find that view-dependent 3D picture obtained by our proposed method is optimal to viewer.

  • PDF

Evaluating Carbon Dioxide Emission from Cadastral Category based on Tier 3 Approach (Tier 3 방식에 의거한 지목별 온실가스 배출 실태평가)

  • Kim, Dae-Ho;Um, Jung-Sup
    • Spatial Information Research
    • /
    • v.19 no.3
    • /
    • pp.11-22
    • /
    • 2011
  • It is usual for the carbon dioxide emission to be calculated by official energy consumption statistics produced from a number of specialized industrial process such as refinery, power plant etc. The aim of this research was to evaluate potential of cadastral system in monitoring carbon dioxide emitted from land use. An empirical study for a cadastral category was conducted to demonstrate how a on-site measurement can be used to assist in estimating the carbon dioxide emission in terms of land use specific settings. The cadastral category based analysis made it possible to identify area-wide patterns of carbon dioxide emission, which cannot be acquired by traditional Government statistics. It was possible to identify successively increasing trends in the human-related parcels such as housing land while decreasing trends of carbon dioxide in sink parcels(eg. forest). The results indicate that the cadastral parcel could be used not only as a tool to monitor carbon dioxide emission, but also as an evidence to restrict initiation of development activities causing negative influence to carbon dioxide emission such as road construction. As a result, the research findings have established the new concept of "carbon dioxide emission monitoring based on cadastral category", proposed as an initial aim of this paper.

Analysis of surface form change after performing prophylaxis procedure on implant surface using various oral hygiene instruments (다양한 구강위생기구를 이용하여 임플란트 표면의 Prophylaxis 시행시 표면형태의 변화분석)

  • Lee, Sun-Goo;Lim, Sung-Bin;Chung, Chin-Hyung;Kwon, Sang-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.1
    • /
    • pp.1-17
    • /
    • 2004
  • It is improtant that performing prophylaxis procedure on an infected implant surface in order to treat peri-implantitis should not change the surface roughness and composition, so that the surface can be recovered to almost same condition as initial implant surface. This thesis, therefore, studied an effect of various oral hygiene instrument on implant surface. A surface roughness measurement instrument and an infection electron microscope were used to observe a change on surface. The purpose of this study was to obtain a clinical guidelines during implant care and peri-implantitis treatment. The result were as follows 1. Ra values (surface roughness value) at experimental group 1, group 2, and group 5 were increased significantly as compared with comparison group(p<0.05). 2. When compared experimental group 1 with each experimental groups at which prohylaxis procedure was performed, mean values of Ra at experimental group 2, group 3, group 6, and group 7 were decreased significantly(p<0.05). 3. Mean value of Ra was lowest at experimental group 2, and highest at experimental group 2, and highest at experimental group 5. 4. Analysis of SEM showed that was significant surface change at experimental group 2, group 3, group 4, group 5, and group 6 as compared with comparison group(X1000). 5. Analysis fo EDX showed that a quantity of Ti on surface for experimental group 6 was very similar to that for comparison group. In conclusion, air-powder abrasive and citric acid, plastic instrument are safe methods to use for performing prophylaxis procedure on implant care or for cleaning and sterilization process on treatment of peri-implantitis, based on the result that those method did not affect implant surface roughness and Ti composition.

On the Design of High Order Transformer Circuit Using the Genetic Algorithm and Its Application to the Wheeler Cap Measurement (유전자 알고리즘을 사용한 안테나 고차 변압 회로 구성과 변압 회로를 사용한 Wheeler Cap 효율 측정법)

  • Cho Chi-Hyun;Choo Ho-Sung;Park Ik-Mo;Kang Jin-Seob
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.8 s.111
    • /
    • pp.753-759
    • /
    • 2006
  • Generally, the Wheeler cap method is used to measure the efficiency of small antennas. This method often gives an unreliable efficiency when the antenna has a complicated operating principle. However, if the high-order circuit model which more closely represents the input impedance of the antenna is used in Wheeler cap method, then more accurate efficiency can be achieved. In this paper, we propose a novel method that can build the high-order circuit model using transformer circuits with the genetic algorithm(GA). To efficiently reduce the searching space in the GA and improve the convergence of the GA process, we suggest a novel scheme that finds appropriate initial values. Finally we verify the proposed method by measuring the efficiency of some passive RFID tag antennas.

Design of Absorptive Type SPST MMIC Switch for MSM of Satellite Communication (위성통신용 MSM을 위한 흡수형 SPST MMIC 스위치의 설계 및 제작)

  • Yom In-Bok;Ryu Keun-Kwan;Shin Dong-Hwan;Lee Moon-Que;Oh Il-Duck;Oh Seung-Hyeub
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.10 s.101
    • /
    • pp.989-994
    • /
    • 2005
  • A MMIC(Monolithic Microwave Integrated Circuit) switch chip using InGaAs/GaAs p-HEMT process has been designed for MSM(Microwave Switch Matrix) of satellite communication system. An absorptive type MMIC switch is adopted for good reflection coefficients performances of input and output ports at both on and off states. And, a quarter wavelength impedance transformer is realized with lumped elements of MIM capacitor and spiral inductor for 3 GHz band to reduce the chip size. This MMIC switch covers the frequency range of $3.2\~3.6\;GHz$. According to the on-wafer measurement, the fabricated MMIC switch with miniature size of $1.6\;mm{\times}1.3\;mm$ demonstrates insertion loss below 2 dB and isolation above 56.8 dB, and the performance coincides with simulation results.