• Title/Summary/Keyword: process measurement

Search Result 5,168, Processing Time 0.038 seconds

Dielectric Properties of Plasma Polymerized ppMMA Thin Film (플라즈마 증합법으로 증착된 ppMMA 박막의 유전특성)

  • Lim, J.S.;Shin, P.K.;Nam, K.Y.;Kim, J.S.;Hwang, M.H.;Kim, J.T.;Lee, Y.H.;Kang, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1408-1409
    • /
    • 2006
  • In this paper, poly methyl methacrylate thin films were deposited on a ITO glass substrate using a plasma polymerization technique. In order to investigate the influence of the plasma coupling method and plasma conditions on the plasma polymerized poly methyl methacrylate (ppMMA) thin film properties, inductively coupled (ICP) and capacitively coupled plasma (CCP) were used to generate the plasma and the plasma parameters were varied. Molecular structures of the ppMMAs were investigated using a Fourier Transform Infrared (FT-IR) spectroscopy. Dielectric constants of the ppMMA thin films were investigated using a impedance analyzer (HP4192A, LF Impedance Analyzer). Current-Voltage (I-V) characteristics of the ppMMA thin films were investigated using a source measurement unit (SMU: Keithley 2400). Relationship between the plasma coupling technique/process parameter and ppMMA thin films properties were investigated.

  • PDF

Design and Manufacture of Multi-layer VCO by LTCC (저온 동시소성 세라믹을 이용한 적층형 VCO의 설계 및 제작)

  • Park, Gwi-Nam;Lee, Heon-Yong;Kim, Ji-Gyun;Song, Jin-Hyung;Rhie, Dong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.291-294
    • /
    • 2003
  • The circuit substrate was made from the Low Temperature Cofired Ceramics(LTCC) that a $\varepsilon_\gamma$ was 7.8. Accumulated Varactor and the low noise transistor which were a Surface Mount Device-type element on LTCC substrate. Let passive element composed R, L, C with strip-line of three dimension in the multilayer substrate circuit inside, and one structure accumulate band-pass filter, resonator, a bias line, a matching circuit, and made it. Used Screen-Print process, and made Strip-line resonator. A design produced and multilayer-type VCO(Voltage Controlled Oscillator), and recognized a characteristic with the Spectrum Analyzer which was measurement equipment. Measured multilayer structure VCO is oscillation frequency 1292[MHz], oscillation output -28.38[dBm], hamonics characteristic -45[dBc] in control voltage 1.5[V], A phase noise is -68.22[dBc/Hz] in 100 KHz offset frequency. The oscillation frequency variable characteristic showed 30[MHz/V] characteristic, and consumption electric current is approximately 10[mA].

  • PDF

A study on the Band Gap Energy Measurement of Liquid Phase Photocatalytic Sols (액상 광촉매 졸의 밴드갭 에너지 측정 연구)

  • Yoon, Cho-Rong;Qamar, Mohamad;Oh, Hyo-Jin;Hwang, Jong-Seon;Kim, Sun-Jae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.12a
    • /
    • pp.39-42
    • /
    • 2006
  • Titania sols or powders were are very promising materials for environment as photocatalyst. The band gap energy of $TiO_2$ has been known to be 2.8 to 3.2 eV. But the measuring system of its band gap is usually depend on absorption properties. Thus, in this study, absorption properties of $TiO_2$ sols prepared by hydrothermal process were researched with the effect of various particle sizes and concentrations. The mean particle size in $TiO_2$ sols increased as 15 nm to 60 nm, absorption graph measured by UV-Vis spectrometer shows to move red-shift. When dilute solution added with $2^n$ in $TiO_2$, the band gap energy increases as linear function.

  • PDF

Research of $tan{\delta}$ Measurement on Pole Transformer Using DSP (DSP를 이용한 주상변압기 $tan{\delta}$ 측정기법 연구)

  • Lee, Bo-Hoo;Kim, Jae-Chul;Yoon, Yong-Han;Rim, Sung-Jung;Kim, Oun-Seok;Lee, Su-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.462-463
    • /
    • 1996
  • This study describes the dissipation factor measuring techniques of insulating oil on the operating, transformer by using digital signal processing. After applying voltage to the sensor which is installed in a transformer, acquiring source voltage and current of sensor and using cross-correlation techniques, we can check the dissipation factor of insulating oil. To improve measuring accuracy and the speed of process, we use hardware such as TMS320C31 DSP board and analog filter and software such as fast cross-correlation techniques, rectangular window, and digital filtering techniques. We simulated the measuring accuracy and the degree of the noise effect of this new measuring techniques by computer simulation, and compared the simplified measuring devices with Schering Bridge on degraded insulating oil. The result showed that this measuring technique can be used as diagnostic method on the pole transformers.

  • PDF

Research of $Tan{\delta}$ Measurement on pole Transformer Using DSP (DSP를 이용한 주상변압기 $Tan{\delta}$ 측정기법 연구)

  • Lee, Bo-Hoo;Kim, Jae-Chul;Lee, Su-Kil;Yoon, Yong-Han;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.270-272
    • /
    • 1996
  • This paper describes the dissipation factor measuring techniques of insulating oil on operating pole transformer by using digital signal processor. After applying voltage to the electrodes which is installed in a transformer, acquiring source voltage and current of electrodes and using cross-correlation techniques, we can check the dissipation factor of insulating oil. To improve measuring accuracy and the speed of process, we use hardware such as TMS320C31 DSP board and software such as cross-correlation techniques and rectangular window techniques. We simulated the measuring accuracy and the degree of the noise effect of this new measuring techniques by using computer simulation, and compared the simplified measuring devices with schering bridge on degraded insulating oil. The result showed that this measuring technique can be used as diagnostic method on the pole transformers.

  • PDF

Fabrication of Composite Powders by Mechanical Alloying of Magnetite-M (M = Ti, Al) Systems (마그네타이트와 금속(Ti, Al)의 기계적 합금화에 의한 복합분말의 합성)

  • 홍대석;이성희;이충효;김지순;권영순
    • Journal of Powder Materials
    • /
    • v.11 no.3
    • /
    • pp.247-252
    • /
    • 2004
  • Recently, it has been found that mechanical alloying (MA) facilitates the nanocomposites formation of metal-metal oxide systems through solid-state reduction during ball milling. In this work, we studied the MA effect of Fe$_{3}$O$_{4}$-M (M = Al, Ti) systems, where pure metals are used as reducing agents. It is found that composite powders in which $Al_{2}$O$_{3}$ and TiO$_{2}$ are dispersed in $\alpha$-Fe matrix with nano-sized grains are obtained by mechanical alloying of Fe$_{3}$O$_{4}$ with Al and Ti for 25 and 75 hours, respectively. It is suggested that the large negative heat associated with the chemical reduction of magnetite by aluminum is responsible for the shorter MA time for composite powder formation in Fe$_{3}$O$_{4}$-Al system. X-ray diffraction results show that the reduction of magnetite by Al and Ti if a relatively simple reaction, involving one intermediate phase of FeAl$_{2}$O$_{4}$ or Fe$_{3}$Ti$_{3}$O$_{10}$. The average grain size of $\alpha$-Fe in Fe-TiO$_{2}$ composite powders is in the range of 30 nm. From magnetic measurement, we can also obtain indirect information about the details of the solid-state reduction process during MA.

Development and Validation of a Scale to Measure Engineering Empathy (공학적 공감능력 검사도구 개발 및 타당화 연구)

  • Choi, Sung-Youn;Ma, Eunjeong
    • Journal of Engineering Education Research
    • /
    • v.23 no.5
    • /
    • pp.51-60
    • /
    • 2020
  • The purpose of this study is to develop and validate an Engineering Empathy Instrument. Engineering empathy is defined as the ability that encompasses the following three qualities, a skill to interpret social issues and phenomenon that may occur in the process of interactions between human beings and engineering systems, a practical orientation that enables one to take stakeholders' perspectives to carry out an engineering project, and a professional way of being that acknowledges empathic skills and associated practice orientations. Based on this notion, we develop a scale to measure engineering empathy and have surveyed 429 engineering students. Evidence for the validity and reliability of the scale is presented. In conclusion, we find that engineering empathy can be measured and conceptualized as three domains: a Learnable Skill (ELS), a Practical Orientation (EPO), and a Professional Way (EPW). We also find that sophomores show the highest level of engineering empathy as compared with other graders. While students accumulate technical knowledge, their understanding about engineering in social and interpretational contexts gets weakened. This implies that engineering education necessarily emphasizes the impacts of engineering solutions in interpersonal, societal, technologies, and environmental contexts.

Development of QCM dew point sensor and its sensing characteristics study (수정미소저울 노점센서 제작 및 반응특성 연구)

  • Kwon, Su-Yong;Kim, Jong-Chul;Choi, Byung-Il
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.269-276
    • /
    • 2006
  • This paper represents development of quartz crystal microbalance (QCM) and usage as a dew point sensor. The temperature of a quartz resonator was controlled precisely from $20^{\circ}C$ to $-30^{\circ}C$ with the ramping rate of $0.1^{\circ}C/s$ by using a custom-made crystal holder housing the quartz resonator associated with a thermoelectric cooler (Peltier cooler), which results in the working range from $15.2^{\circ}C$ to $-24.0^{\circ}C$ based on an accurate holder temperature compensation and temperature effect compensation process. The developed QCM dew point sensor and analysis techniques show very good sensing characteristics at measurement of moist air with the relative humidity from 10 %R.H. to 90 %R.H. generated by a divided-type humidity generator and the dew point temperatures were determined with an accuracy of less than ${\pm}0.18^{\circ}C$, which also showed good agreement with reference values in their error range.

A SPICE-Compatible Model for a Gate/Body-Tied PMOSFET Photodetector With an Overlapping Control Gate

  • Jo, Sung-Hyun;Bae, Myunghan;Choi, Byoung-Soo;Choi, Pyung;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.353-357
    • /
    • 2015
  • A new SPICE-compatible model for a gate/body-tied PMOSFET photodetector (GBT PD) with an overlapping control gate is presented. The proposed SPICE-compatible model of a GBT PD with an overlapping control gate makes it possible to control the photocurrent. Research into GBT PD modeling was proposed previously. However, the analysis and simulation of GBT PDs is not lacking. This SPICE model concurs with the measurement results, and it is simpler than previous models. The general GBT PD model is a hybrid device composed of a MOSFET, a lateral bipolar junction transistor (BJT), and a vertical BJT. Conventional SPICE models are based on complete depletion approximation, which is more applicable to reverse-biased p-n junctions; therefore, they are not appropriate for simulating circuits that are implemented with a GBT PD with an overlapping control gate. The GBT PD with an overlapping control gate can control the sensitivity of the photodetector. The proposed sensor is fabricated using a $0.35{\mu}m$ two-poly, four-metal standard complementary MOS (CMOS) process, and its characteristics are evaluated.

Mobile u-healthcare system in IEEE 802.15.4 WSN and CDMA network environments

  • Toh, Sing-Hui;Lee, Seung-Chul;Lee, Hoon-Jae;Do, Kyeong-Hoon;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.337-342
    • /
    • 2009
  • This paper describes a robust mobile u-healthcare system with multiple physiological signs measurement capability in real time with integration of WSN(wireless sensor network) technology and CDMA(code division multiple access) network. A cellular phone receives health data in WSN and performs local physiological signs analysis at a phone processor, and then transmits abnormal data to server for further detail or precise health signal evaluation by a medical doctor over a CDMA network. Physiological signs of the patients are continuously monitored, processed and analyzed locally at cellular phone process to produce useful medical information for diagnosis and tracking purposes. By local simple analysis in cellular phone processor we can save the data transmission cost in CDMA network. By using the developed integrate ubiquitous healthcare service architecture, patients can realize self-health checking so that the prevention actions can be taken earlier. Appropriate self-monitoring and self-management can cure disease and relieve pain especially for patients who suffer from chronic diseases that need long term observation.