• Title/Summary/Keyword: process measurement

Search Result 5,167, Processing Time 0.037 seconds

An Experimental Investigation of Air Fuel Ratio Measurement using Laser Induced Acetone Fluorescence (아세톤 형광을 이용한 공연비 측정 기법 연구)

  • Park Seungjae;Huh Hwanil;Oh Seungmook
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.353-356
    • /
    • 2002
  • Planar laser induced fluorescence(PLIF) has been widely used to obtain two dimensional fuel distribution. Preliminary investigation was performed to measure quantitative air excess ratio distribution in an engine fueled with LPG. It is known that fluorescence signal from acetone as a fluorescent tracer is less sensitive to oxygen quenching than other dopants. Acetone was excited by KrF excimer laser (248nm) and its fluorescence image was acquired by ICCD camera with a cut-of filter to suppress Mie scattering from the laser light. For the purpose of quantifying PLIF signal, an image processing method including the correction of laser sheet beam profile was suggested. Raw images were divided by each intensity of laser energy and profile of laser sheet beam. Inhomogeneous fluorescence images scaled with the reference data, which was taken by a calibration process, were converted to air excess ratio distribution. This investigation showed instantaneous quantitative measurement of planar air excess ratio distribution for gaseous fuel.

  • PDF

Three-dimensional Flow Structure inside a Plastic Microfluidic Element (미소유체요소 내부유동의 3차원 측정 및 수치해석)

  • Lee Inwon;An Kwang Hyup;Nam Young Sok;Lee In-seop
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.419-422
    • /
    • 2002
  • A three-dimensional inlet flow structure inside a microfluidic element has been investigated using a micro-PIV(particle image velocimetry) measurement as well as a numerical analysis. The present study employs a state-of-art micro-PIV system which consists of epi-fluorescence microscope, 620nm diameter fluorescent seed particles and an 8-bit megapixel CCD camera. For the numerical analysis, a commercial software CFD-ACE+(V6.6) was employed for comparison with experimental data. Fixed pressure boundary condition and a 39900 structured grid system was used for numerical analysis. Velocity vector fields with a resolution of $6.7{\times}6.7{\mu}m$ has been obtained, and the attention has been paid on the effect of varying measurement conditions of particle diameter and particle concentration on the resulting PIV results. In this study, the microfluidic elements were fabricated on plastic chips by means of MEMS processes and a subsequent melding process.

  • PDF

PIV measurements of a microfluidic elements fabricated in a plastic chip (플라스틱 미소유체요소 내부유동의 PIV 측정)

  • Lee, In-Won;Choi, Jay-Ho;Lee, In-Seop
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.400-404
    • /
    • 2001
  • A micro-PIV(particle image velocimetry) measurement has been conducted to investigate flow fields in such microfluidic devices as microchannels and micronozzle. The present study employs a state-of-art micro-PIV system which consists of epi-fluorescence microscope, 620nm diameter fluorescent seed particles and an 8-bit megapixel CCD camera. Velocity vector fields with a resolution of $6.7\times6.7{\mu}m$ has been obtained, and the attention has been paid on the effect of varying measurement conditions of particle diameter and particle concentration on the resulting PIV results. In this study, the microfluidic elements were fabricated on plastic chips by means of MEMS processes and a subsequent molding process. Flow fields in a variety of microchannels as well as micronozzle have been investigated.

  • PDF

Development of high efficiency impeller for the process of ABS resin cohesion by using flow measurement (유동계측을 이용한 ABS 수지 응집 공정 혁신을 위한 고성능 교반기 임펠러 개발)

  • Kim, Jung-Hwan;Park, Jae-Hyoun;Lee, Hyun-Sik;Ok, Pyeong-Kweon;An, Ik-Jin
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.325-326
    • /
    • 2006
  • 현 화학플랜트에서 사용되고 있는 ABS 수지 응집 공정의 경우 교반기 내부의 불균일한 유동분포와 유동메커니즘의 문제점은 공정 제품의 생산성을 저하 시키는 원인으로 작용하고 있다. 그러나 우수한 성능의 산업용 교반기를 설계하기 위해선 반드시 교반성능에 영향을 미치는 다양한 내부의 유동특성의 정량적인 실험 데이터 확보가 필요하나, 3차원적 비정상 특성을 나타내는 복잡한 구조의 내부 유동특성에 관한 정량적 해석은 현재까지도 상당한 어려운 문제로 남아있다. 이에 이런 문제점을 개선하여 생산성을 향상시키기 위해서는 PIV 기법을 이용한 교반기 내부의 유동분포와 유동메커니즘을 규명하여 교반기 내부의 최적화된 유동을 형성시키는 임펠러의 형상을 개발하고자 한다.

  • PDF

Study on the multi-channel dosimetry system with microprocessor and its application to radition therapy (마이크로 프로세서를 이용한 선량측정 장치의 제작과 그 응용에 관한 연구)

  • 강정구;이정옥;김승곤;김부길;김진기
    • Progress in Medical Physics
    • /
    • v.3 no.1
    • /
    • pp.19-24
    • /
    • 1992
  • We have desingned multi channel dosimetry system with Intel single-chip microprocessor. We considered that this system is very useful for patient dose measurement, measurement of sealed source dose distribution and calibration of small field for stereotatic radiosurgery system We have designed that this system use commercially available semicondutor detector and personal computer can control this system and process data through RS-232C serial port.

  • PDF

공작기계의 가공 시 열변형에 의한 오차 예측 시스템 개발

  • 안경기;조동우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.257-262
    • /
    • 1997
  • A compact measurement system is developed to measure in-process errors due to thermal deformation of a machine tool, this system is composed of a gauge, 5gap-sensors and a PC. The gauge is made of invar, which is a material that has a very low thermal expansion coefficient. A new neural network model is constructed to estimate thermally induced machine tool errors based on the measured data,the given data,that is a width of cut,a depth of cut, a feed rate, a spindel speed etc, and the calculated data. The detail of the model proposed is described in the paper together with the experimental methodologies using a proposed compact measurement system to examine the validity of the proposed approach.

Study on the High Speed WIM(Weigh-in-Motion) Measurement with Optical Fiber Sensor System (광섬유센서를 이용한 고속주행 트럭의 축중 측정에 관한 연구)

  • 조성규;김기수;배병우
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.04a
    • /
    • pp.451-460
    • /
    • 2003
  • In this paper, high speed fiber optic sensor weigh-in motion (WIM) system is proposed. Bragg gratings which have several advantages such as good reproducibility and good multiplicity compare to other optical fiber sensors are used for the system. Fabry-Perot filter for the signal process, which cannot be used in the high speed measurement because of the limitation in fast operation of PZT, is excluded. A new signal processing system which employs bandwidth filter is proposed and bridge type new sensor package design is also proposed. Design of the mold supporter is modified to round shape and then supporting points do not change. The data from the fiber sensors show identical and linear behavior to the axle weight. The proposed fiber optic WIM system is tested in the laboratory and experimented with actual trucks. The new concept of calibration is introduced and calculated by the experiments. The calibrated weight data show good approximations to real axial weights regardless the velocities of the truck.

  • PDF

Study on the upgrade reliability of inkjet droplet measurement using machine vision (머신비젼을 이용한 잉크젯 드랍 측정 시스템의 신뢰성 향상에 대한 연구)

  • Kim, Dong-Eok;Lee, Jun-Ho;Jeong, Seong-Uk
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2007.07a
    • /
    • pp.365-366
    • /
    • 2007
  • Micro jetting drop inspection system is essential to measuring micro drop volume. Measuring pico-liter drop volume is useful for new LCD color filter product process that is based on inkjet printing technology. To upgrade the reliability in drop measurement system, we use the auto focusing & multi drop reiteration & blurring average algorism. First of all we used standard mark for gage R&R in the vision system. Finding the most suitable threshold for multi blurring drop, is the main key of this research. Sensitivity of vision system is a standard in measuring the upgrade system level. So, suitable threshold can upgrade the performance of jetting drop inspection system.

  • PDF

Local stereo matching using combined matching cost and adaptive cost aggregation

  • Zhu, Shiping;Li, Zheng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.1
    • /
    • pp.224-241
    • /
    • 2015
  • Multiview plus depth (MVD) videos are widely used in free-viewpoint TV systems. The best-known technique to determine depth information is based on stereo vision. In this paper, we propose a novel local stereo matching algorithm which is radiometric invariant. The key idea is to use a combined matching cost of intensity and gradient based similarity measure. In addition, we realize an adaptive cost aggregation scheme by constructing an adaptive support window for each pixel, which can solve the boundary and low texture problems. In the disparity refinement process, we propose a four-step post-processing technique to handle outliers and occlusions. Moreover, we conduct stereo reconstruction tests to verify the performance of the algorithm more intuitively. Experimental results show that the proposed method is effective and robust against local radiometric distortion. It has an average error of 5.93% on the Middlebury benchmark and is compatible to the state-of-art local methods.

Development of Ultra-Precision Machining Technology for V-Shape Micropatterns with 32" Large Surface Area (32" 대면적 V-형상 미세 패턴을 위한 초정밀 가공기술 개발)

  • Lee, Sung-Gun;Kim, Hyun-Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.3
    • /
    • pp.315-322
    • /
    • 2011
  • High-accuracy micropatterns such as V-shaped microgrooves are increasingly in demand for various engineering areas. And the technical trend goes for large surface areas in precision machining technology. So micropatterns with large surface areas are expected to play an increasingly important role in today's manufacturing technology In this study, we focused on developing machining technologies. First, a machine vision system for precise tool setting is developed. Second, an on-machine measurement (OMM) system for large-area measurement is implemented. And also software for tool path generation and simulation is developed. With these technologies we fabricated large-surface micropatterns in an electroless nickel-plated workpiece with single-crystal diamond tools and a 32-in, $675mm{\times}450mm$ mold with tens of V-and pyramid-shaped micropatterns.