• Title/Summary/Keyword: problems of green school

Search Result 173, Processing Time 0.028 seconds

A Consideration of the Correlation Between the Change of Surface Temperature on the Roof and the Adoption of the Green Roof vs Non Green Roof -Application in DaeJeon Area- (옥상녹화와 비 옥상녹화 표면의 온도변화 상관관계 고찰 -대전지역을 중심으로-)

  • Lee, Eung-Jik;Kim, Jun-Hui
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.134-140
    • /
    • 2012
  • With rapid modernization and industrialization, many urban areas are becoming overcrowded at a rapid pace and such urban ecological problems as heat island effect are becoming serious due to the reduced green zones resulted from the indiscriminate development. To solve this problem, ecological park, constructed wetlands, and greening on the elevation, balcony, and roof of a building that have the structure and function very close to the state of nature are currently being promoted at the urban or regional level. Especially green roof will be able to not only provide the center of a city with a significant portion of green area but also help to relive heat island effect and improve micro climate by preventing concrete of a building from absorbing heat. According to a recent study, the temperature of green roof in the summer season shows a lower temperature than the outdoor temperature, but inversely the concrete surface shows a higher temperature. Accordingly, this study measured the surface temperature of buildings with green roof in Daejeon area in order to determine how the green roof system would have an impact on the distribution of surface temperature and did a comparative analysis of the distribution of the surface temperature of green roof vs non-green roof based on these theoretical considerations. As a result, it was found that the surface temperature of green roof was lower by $4{\sim}7^{\circ}C$ than that of non-green roof. This is expected to contribute to the mitigation of urban heat island effects.

A Study on the Necessary Spaces and Area Standards of Integration Facility for Early Childhood Education and Care (영유아 교육·보육 통합시설의 필요 공간과 면적기준에 관한 연구)

  • Cho, Jin Il;Choi, Hyeong Ju
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.17 no.2
    • /
    • pp.22-37
    • /
    • 2018
  • This study suggests desirable disaster safety education curriculum through analyzing the operational status of the school disaster safety management training course and demand survey of school staff. First, the problem of the disaster safety training course of the school is not connected with the lack of law and system and the school disaster safety job. Second, improvement of law and system and variety of training should be made to acquire professional knowledge. Third, it is necessary to divide curriculum into the following four categories, according to educational needs of public officials ; Educational administration officers course focused on facility safety, maintenance and disaster countermeasure. Educational officials in technical post course addressing approval and permission of school facility projects, seismic reinforcement of school building, etc. Educational supervisors course covering roles and responsibilities of the school safety supervisors in the event of disaster. Teaching staffs course focused on safety instructions for students. Fourth, it is found that lectures and experiential learning methods are the most desirable methods of teaching and learning, and the major ranks are earthquake disaster, fire, gas, typhoon, school road, and electrical safety.

Proposal of Singularity-Circumvented Green's Functions for 2D Periodic Structures in Homogeneous Medium (특이점이 제거된 2 차원 단일매질 주기구조에 대한 그린함수의 제안)

  • Kahng, Sung-Tek;Kim, Hyeong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.133-134
    • /
    • 2006
  • In this paper, a novel method is presented for efficient calculation of the spatial-domain Green's functions of 2D electromagnetic problems. This method combines spectral and spatial domain calculation schemes and prevents the Green's functions from diverging at the singularities that complicate the process of the Method of Moment(MoM) application. For the validation of this proposed method, fields will be evaluated along the spatial distance including zero distance for 2D free-space and periodic homogeneous geometry. The numerical results show the validity of the prosed method and correspondng physics.

  • PDF

A calculation method for finite depth free-surface green function

  • Liu, Yingyi;Iwashita, Hidetsugu;Hu, Changhong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.7 no.2
    • /
    • pp.375-389
    • /
    • 2015
  • An improved boundary element method is presented for numerical analysis of hydrodynamic behavior of marine structures. A new algorithm for numerical solution of the finite depth free-surface Green function in three dimensions is developed based on multiple series representations. The whole range of the key parameter R/h is divided into four regions, within which different representation is used to achieve fast convergence. The well-known epsilon algorithm is also adopted to accelerate the convergence. The critical convergence criteria for each representation are investigated and provided. The proposed method is validated by several well-documented benchmark problems.

Application and Analysis of 2D FRI (Finite Rate of Innovation) Super-resolution Technique in Vision Navigation (영상 항법에서의 2D FRI (Finite Rate of Innovation) Super-resolution 기법 적용 및 분석)

  • Yoo, Kyungwoo;Kong, Seung-Hyun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.1
    • /
    • pp.1-10
    • /
    • 2015
  • In urban area, since multipath and signal attenuations frequently occur due to street trees, street lights and buildings, it is difficult to obtain accurate navigation solution using GPS. As these problems also impact negatively on the INS/GPS coupled system, implementing advanced transportation systems such as autonomous navigation system and Intelligent Transportation System (ITS) become quite hard. For this reason, to alleviate deterioration of navigation system performance in urban area, direction information extraction algorithm using vision system is proposed in this paper. 2D Finite Rate of Innovation (FRI) technique is applied to extract lane edges. The proposed technique is simulated using road images and feasibility of proposed technique is analyzed through the simulation results.

Improvement Directions for the G-SEED System from the Resident's Perspective - Focused on Certification Assessment Criteria for Apartment Buildings -

  • Choi, Yeo Jin;Lhee, Sang Choon
    • KIEAE Journal
    • /
    • v.14 no.4
    • /
    • pp.19-26
    • /
    • 2014
  • The building section is providing immediate causes for global climate change problems since it takes about 50% of carbon emission, 20~50% of waste discharge, 33% of energy consumption, 40% of resource use, and 17% of water consumption. So, many countries over the world have developed and implemented green building certification systems to assess sustainable performances of buildings since the early 1990s. In korea, the green building certification system to induce the diffusion of sustainable buildings was first introduced in 2002 and developed as an improved version of the G-SEED(Green Standard for Energy and Environmental Design) system in 2013 after major revisions of related legislations. This research conducts a survey targeting residents on an apartment building that was certified as green building and examines the importance of assessment criteria on apartment buildings to certify green buildings using the Analytic Hierarchy Process(AHP) method. And it proposes a new direction on certification assessment standards from the resident's prospective. As a result, assessment criteria such as indoor environment, ecological environment, energy & environment pollution, and maintenance management among 7 main ones turned out important on assessing the G-SEED system for apartment buildings, while criteria such as material & resource, water circulation management, and land use & transportation did relatively unimportant.

Environmental Performance Evaluation for Song-do City Constructions by using Green Building Certification Criteria (친환경건축물(親環境建築物) 인증기준(認證基準)을 이용(利用)한 송도국제도시(松島國際都市) 건축물(建築物)의 친환경성(親環境性) 평가(評價))

  • Park, Tae-Bum;Kim, Yong-Shik
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.3
    • /
    • pp.111-117
    • /
    • 2006
  • Song-do City is a newly constructed city built on land reclaimed from the seaside and the surrounding area. Its development involved a long process since the basic plans for reclamation of the publicly owned seaside area in Song-do were drawn up in September 1979. However, if we take a look at the overall status of the project as it is carried on at present, it is hard to deny that the project is trapped inside the same legal restrictions as are all other existing cities, which permits Song-do City to meet only very minimum standards. This study intends to analyze and assess the Song-do City's environmentally friendly construction and to rate its current development status, exposing any problems and offering alternative solutions. In this paper, the current state of constructions in Song-do City were reviewed. Then a quantitative analysis and assessment for the Song-do City constructions of apartments, complex buildings, office buildings, and school facilities were conducted by using green building certification criteria. Finally the synthetic results of environmental performance evaluation for Song-do city constructions and follow-up suggestions were described.

The measured field survey for the improvement of the working environment of workers in the plant factory (식물공장 근로자의 작업 환경개선을 위한 현장실측 연구)

  • Kwo, Hyuk-Min;Jeong, Seok-Hwan;Kang, Joo-Won;Yang, Jeong-Hoo
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.5
    • /
    • pp.43-52
    • /
    • 2014
  • A plant factory system is getting the spotlight as alternatives to cope with the weather anomaly and food crisis because of the global warming. A study on 'Plant Processing Factory System' has been proceeded to develope 'low-carbon green growth' since our government selected it as the green technologies in 2010. The plant factory has played a major role in growth industries connected to many other fields like low-carbon as well as lighting and automated system. This study is aimed to solve the problems on low productivity and health problem of plant workers caused by highly concentrated carbon dioxide and low temperature in each process in the plant factory. It is aimed to research data to understand the actual conditions of plant workers and improve the thermal environment.

Study on Surface Temperature Change of PV Module Installed on Green Roof System and Non-green Roof System (옥상녹화와 비 옥상녹화 평지붕에 설치 된 PV모듈의 표면온도 변화 고찰)

  • Yoo, Dong-Chul;Lee, Eung-Jik;Lee, Doo-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.214-219
    • /
    • 2011
  • Today, various activities to save energy are being conducted around the world. Even in our country, carbon reduction policy is being conducted for low carbon green growth and with this movement, effort to replace energy sources by recognizing the problems on environment pollution and resource exhaustion due to the indiscrete usage of fossil fuel is being made. Therefore, active study on renewable energy is in progress as part of effort to replace the energy supply through fossil fuel and solar ray industry has rapidly developed receiving big strength of renewable energy policies. The conclusion of this study measuring the surface temperature change of single crystal and polycrystalline PV module in green roof system and non-green roof system aspect are as follows. There was approximately $4^{\circ}C$ difference in PV module temperature in green roof system and non-green roof system aspect and this has the characteristic to decrease 0.5% when the temperature rises by $1^{\circ}C$ when the front side of the module is $20^{\circ}C$ higher than the surrounding air temperature following the characteristic of solar cells. It can be concluded that PV efficiency will be come better when it is $4^{\circ}C$ lower. Also, in result of temperature measurement of the module back side, there was $5^{\circ}C$ difference of PV module installed on the PV module back side and green roof system side on the 5th, $3^{\circ}C$ on the 4th, $2^{\circ}C$ on the 5th to show decreasing temperature difference as the air temperature dropped, but is judged that there will be higher temperature difference due to the evapotranspiration latent heat effect of green roof system floor side as the temperature rises. Based on this data, it is intended to be used as basic reference to maximize efficiency by applying green roof system and PV system when building non-green roof system flat roof.

  • PDF

Analysis of Isolation, Connection and Circulation with the Neighborhood park in Daegu

  • Ryu, Yeon-Su;Ra, Jung-Hwa;Cho, Hyun-Ju;Kim, Jin-Hyo;Kwon, Oh-Sung
    • Current Research on Agriculture and Life Sciences
    • /
    • v.30 no.1
    • /
    • pp.13-25
    • /
    • 2012
  • Major and reckless development which have been continued during the last half century, have caused decrease and damage of urban green spaces in the point of qualitative and quantitative view. Particularly, it brought about reduction to urban neighborhood park which has taken the main role for landscape ecological value. Recently, neighborhood park planning based on the landscape ecological results has been increasing gradually. Most of all, diverse attempts such as the application of shape character analysis and the step of landscape ecological planning in urban park planning have been proposed. Today, we recognize the importance of comprehensive approach in urban green planning and neighborhood park planning, but landscape ecological approach which is analyzing character and making proposal with isolation, connection and circulation is still insufficient. Most of neighborhood parks in Korea are surrounded by buildings and isolated from adjacent green spaces. Besides, these parks have landscape ecological problems such as reduction of size, isolation from adjacent green spaces, decline of nature, and excessive pavement which we ignored during urban development process. We have sympathy for understanding landscape ecological characters and considering improvement proposals for neighborhood parks Therefore, the purpose of this study was to 1) select five neighborhood parks in Daegu, 2) analyze landscape ecological characters with isolation, connection and circulation, and 3) compare data. It is certain that these results should be the main data for the arrangement of improvement proposals which landscape ecological characters were appled to.

  • PDF