• Title/Summary/Keyword: problem analysis

Search Result 16,365, Processing Time 0.041 seconds

Dishes Contributing to Sodium Intake of Elderly Living in Rural Areas (농촌 노인의 나트륨 섭취에 기여하는 음식 분석)

  • Moon, Hyun-Kyung;Choi, Soon-Ok;Kim, Jung-Eun
    • Korean Journal of Community Nutrition
    • /
    • v.14 no.1
    • /
    • pp.123-136
    • /
    • 2009
  • Sodium is a necessary element for the body. Excessive intake of sodium is known as one of the risk factors for chronic diseases. Recently, increasing numbers of people in Korea are suffering from chronic diseases. Major causes of deaths were chronic degenerative disease with the rising aging population. Especially, the population of rural areas is growing older fast. In rural areas, it is known that under nutrition and high sodium intake were major nutritional problems. For sodium intake, there were some studies about contributing food items. They were not enough to show diets relate to sodium intakes. Thus, this study analyzed dishes contributing to sodium intakes of elderly living in rural areas. Dietary intakes using "the 24hour recall method" were used. For the analysis for sodium intakes, "Can-pro3.0" was used. Ranking of dishes by contributions of sodium intakes were Korean cabbage, kimchi (19.6%), seasoned soybean paste (5.3%), soybean paste (4.6%), soybean paste soup dried radish leaves (3.5%), hot pork and kimchi stew (3.4%) in order. Ranking of dish groups by sodium intakes was kimchies (28.3%), soup and hot soups (22.8%), stews and casseroles (9.7%), seasonings (8.2%),and seasoned vegetables (6.0%) in order. One-dish meals among cooked rice, wheat noodles among noodle and mandu, soups using the soybean paste, stews using soybean paste and kimchi, salted fish among grilled foods, stir-fried anchovy among stir-fried foods, seasoned spinach, and Korean cabbage kimchi contributed to sodium intakes. As the nutrition deficiency of the elderly living in rural areas could be a problem, and excessive sodium intakes is threatening to their health, it is needed for the senior citizens to have adequate knowledge for diets containing less sodium. And recipes for healthy food and nutrition education based on their diets are needed.

A Study and Design on security ticket based CERT system for quantified incident management (정량적 침해사고 관리를 위한 Security Ticket 기반의 침해사고 관리시스템(CERT) 설계 및 관리방안 연구)

  • Kim, Sun-Tae;Jun, Moon-Seog;Park, Dea-Woo
    • KSCI Review
    • /
    • v.15 no.1
    • /
    • pp.141-150
    • /
    • 2007
  • There's been a difficulty for general corporate to adopt recent incident response study because those studies focus on nation wide CERT Coordination Center or large organization aspect. This study is focus on study and design on security ticket based CERT system through analysis Security management's threat element, attack element. response element and it also help general corporate establish incident response process that is adjusted on IT operation. Confirmed CERT model's effectiveness and effect of quantitative Security incident management wav that propose executing Security incident response experiment on the basis of this way. This study which Provides general corporate oriented CERT model can be used to improve corporate's capability of responding incident by quantified management technique and select incident response SLA indicator. Already, formation which operate CERT can heighten corporation's information protection level by measure Security incident response result as metrical and analyze and improve problem continuously.

  • PDF

Evaluation of Crack-tip Cohesive Laws for the Mode I Fracture of the Graphene from Molecular Dynamics Simulations (그래핀의 모드 I 균열에 대한 분자동역학 해석으로부터 균열 선단 응집 법칙의 평가)

  • Kim, Hyun-Gyu
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.5
    • /
    • pp.393-399
    • /
    • 2013
  • In this paper, a novel approach to estimate cohesive laws for the mode I fracture of the graphene is presented by combining molecular dynamic simulations and an inverse algorithm based on field projection method and finite element method. The determination of crack-tip cohesive laws of the graphene based on continuum mechanics is a non-trivial inverse problem of finding unknown tractions and separations from atomic simulations. The displacements of molecular dynamic simulations in a region far away from the crack tip are transferred to finite element nodes by using moving least square approximation. Inverse analyses for extracting unknown cohesive tractions and separation behind the crack tip can be carried out by using conservation nature of the interaction J- and M-integrals with numerical auxiliary fields which are generated by systematically imposing uniform surface tractions element-by-element along the crack surfaces in finite element models. The preset method can be a very successful approach to extract crack-tip cohesive laws from molecular dynamic simulations as a scale bridging method.

Toward a Possibility of the Unified Model of Cognition (통합적 인지 모형의 가능성)

  • Rhee Young-Eui
    • Journal of Science and Technology Studies
    • /
    • v.1 no.2 s.2
    • /
    • pp.399-422
    • /
    • 2001
  • Models for human cognition currently discussed in cognitive science cannot be appropriate ones. The symbolic model of the traditional artificial intelligence works for reasoning and problem-solving tasks, but doesn't fit for pattern recognition such as letter/sound cognition. Connectionism shows the contrary phenomena to those of the traditional artificial intelligence. Connectionist systems has been shown to be very strong in the tasks of pattern recognition but weak in most of logical tasks. Brooks' situated action theory denies the. notion of representation which is presupposed in both the traditional artificial intelligence and connectionism and suggests a subsumption model which is based on perceptions coming from real world. However, situated action theory hasn't also been well applied to human cognition so far. In emphasizing those characteristics of models I refer those models 'left-brain model', 'right-brain model', and 'robot model' respectively. After I examine those models in terms of substantial items of cognitions- mental state, mental procedure, basic element of cognition, rule of cognition, appropriate level of analysis, architecture of cognition, I draw three arguments of embodiment. I suggest a way of unifying those existing models by examining their theoretical compatability which is found in those arguments.

  • PDF

IN VITRO EVALUATION OF FRACTURE RESISTANCE OF VARIOUS THICKNESS FIBER- REINFORCED COMPOSITE INLAY FPD

  • Yi Yang-Jin;Yoon Dong-Jin;Park Chan-Jin;Cho Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.6
    • /
    • pp.762-771
    • /
    • 2003
  • Statement of problem. In dentistry, the minimally prepared inlay resin-bonded fixed partial denture (FPD) made of new ceromer / fiber-reinforced composite (FRC) was recently introduced. However, the appropriate dimensions for the long-term success and subsequent failure strength are still unknown. Purpose. The aim of this study was to investigate the most fracture-resistible thickness combination of the ceromer / FRC using a universal testing machine and an AE analyzer. Material and Methods. A metal jig considering the dimensions of premolars and molars was milled and 56-epoxy resin dies, which had a similar elastic modulus to that of dentin, were duplicated. According to manufacturer's instructions, the FRC beams with various thicknesses (2 to 4 mm) were constructed and veneered with the 1 or 2 mm-thick ceromers. The fabricated FPDs were luted with resin cement on the resin dies and stored at room temperature for 72 hours. AE (acoustic emission) sensors were attached to both ends, the specimens were subjected to a compressive load until fracture at a crosshead speed of 0.5 mm/min. The AE and failure loads were recorded and analyzed statistically. Results. The results showed that the failure strength of the ceromer/FRC inlay FPDs was affected by the total thickness of the connectors rather than the ceromer to FRC ratio or the depth of the pulpal wall. Fracture was initiated from the interface and propagated into the ceromer layer regardless of the change in the ceromer / FRC ratio. Conclusion. Within the limitations of this study, the failure loads showed significant differences only in the case of different connector thicknesses, and no significant differences were found between the same connector thickness groups. The application of AE analysis method in a fiber-reinforced inlay FPD can be used to evaluate the fracture behavior and to analyze the precise fracture point.

A SHEAR BOND STRENGTH OF RESIN CEMENTS BONDED TO PRESSABLE PORCELAIN WITH VARIOUS SURFACE TREATMENTS

  • Lee Jong-Yeop;Im Eui-Bin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.379-386
    • /
    • 2003
  • Statement of problem. Resin cements are widely used in adhesive dentistry specially on all ceramic restorations. It is needed to find out adequate bonding strength between different porcelain surface treatments, commercially available porcelains, and different resin cement systems. Purpose. The purpose of this study was to evaluate shear bond strength of resin cements bonded to porcelains in three different modalities; 5 different porcelain surface treatments, 3 different resin cement systems and 3 different commercially available pressable porcelains. Material and Method. This study consisted of 3 parts. Part I examined the effect of five different surface treatments on the pressable porcelain. Fifty discs (5 mm in diameter and 3 mm in height) of Authentic porcelain were randomly divided into 5 groups (n = 10). The specimens were sanded with 320 grit SiC paper followed by 600 grit SiC paper. The specimens were treated as follow: Group 1-Sandblasting (aluminum oxide) only, Group 2 - sandblasting/ silane, Group 3 - sandblasting/ acid etching/ silane, Group 4 - acid etching only, Group 5 - acid etching/ silane. Part II examined the shear bond strength of 3 different resin cement systems (Duolink, Variolink II, Rely X ARC) on acid etching/ silane treated Authentic pressable porcelain. Part 3 examined the shear bond strength of Duolink resin cement on 3 different pressable porcelains (Authentic, Empress I, Finesse). All cemented specimens were stored in distilled water for 2 hours and tested with Ultradent shear bond strength test jig under Universal Instron machine until fracture. An analysis of variance(ANOVA) test was used to evaluate differences in shear bond strength. Result. The shear bond strength test resulted in the following: (1) Acid etched porcelains recorded greater shear bond strength values to the sandblasted porcelains. (2) Silane treated porcelains recorded greater shear bond strength values to non-silane treated porcelains. (3) There was no significant difference between sandblasting/ acid etching/ silane treated and acid etching/ silane treated porcelains. However those values were much higher than other three groups. (4) The shear bond strength with Variolink II was lower than the value of Duolink or Rely X ARC. (5) The shear bond strength of Finesse was lower than the value of Authentic or Empress I.

Histomorphometry and stability analysis of early loaded implants with two different surface conditions in beagle dogs

  • Kim, Dong-Seok;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.10-18
    • /
    • 2009
  • STATEMENT OF PROBLEM. Despite an improved bone reactions of Mg-incorporated implants in the animals, little yet has been carried out by the experimental investigations in functional loading conditions. PURPOSE. This study investigated the clinical and histologic parameters of osseointegrated Mg-incorporated implants in early loading conditions. MATERIAL AND METHODS. A total of 36 solid screw implants(diameter 3.75 mm, length 10 mm) were placed in the mandibles of 6 beagle dogs. Test groups included 18 Mg-incorporated implants. Turned titanium implants served as control. Gold crowns were inserted 4 weeks after implant placement and the dogs were immediately put on a food diet. Implants were observed for 10 weeks after loading. Radiographic assessments and stability tests were performed at the time of fixture installation, $2^{nd}$ stage surgery, 4 weeks after loading, and 10 weeks after loading. Histological observations and morphometrical measurements were also performed. RESULTS. Of 36 implants, 33 displayed no discernible mobility, corresponding to successful clinical function. There was no statistically significant difference between test implants and controls in marginal bone levels(P=.46) and RFA values. The mean BIC % in the Mg-implants was $54.5{\pm}8.4%$. The mean BIC % in the turned implant was $45.3{\pm}12.2%$. These differences between the Mg-implant and control implant were statistically significant(P=.005). CONCLUSIONS. The anodized, Mg-incorporated implant demonstrated significantly more bone-to-implant contact(BIC) in early loading conditions. CLINICAL IMPLICATIONS. The results of this study in beagle dogs suggest the possibility of achieving predictable stability of early loaded free-standing dental implants with Mg-incorporated surface.

The change of rotational freedom following different insertion torques in three implant systems with implant driver

  • Kwon, Joo-Hyun;Han, Chong-Hyun;Kim, Sun-Jai;Chang, Jae-Seung
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.37-40
    • /
    • 2009
  • STATEMENT OF PROBLEM. Implant drivers are getting popular in clinical dentistry. Unlike to implant systems with external hex connection, implant drivers directly engage the implant/abutment interface. The deformation of the implant/abutment interface can be introduced while placing an implant with its implant driver in clinical situations. PURPOSE. This study evaluated the change of rotational freedom between an implant and its abutment after application of different insertion torques. MATERIAL AND METHODS. Three kinds of internal connection implants were utilized for the current study($4.5{\times}12\;mm$ Xive, $4.3{\times}11.5\;mm$ Inplant Magicgrip, $4.3{\times}12\;mm$ Implantium MF). An EstheticBase, a 2-piece top, a Dual abutment was used for its corresponding implant system. The rotational freedom between an implant and its abutment were measured before and after applying 45, 100 Ncm insertion torque. Repeated measures ANOVA was used for statistical analysis. RESULTS. Under 45 Ncm insertion torque, the rotational freedom between an implant and its abutment was significantly increased in Xive(P = .003). However, no significant change was noted in Inplant Magicgrip and Implantium MF. Under 100 Ncm torque, both in Xive(P = .0005) and Implatium MF(P = .03) resulted in significantly increased rotational freedom between the implant and its abutment. DISCUSSION. The design of the implant/implant driver interface effectively prevented the deformation of implant/abutment interface. Little change was noted in the rotational freedom between an implant and its abutment, even though the insertion torque was far beyond clinical application. CONCLUSIONS. The implant/abutment joint of internally connecting implants were quite stable under insertion torque in clinical situation.

A Study on Human Resources Management for Hotel Kitchen (호텔주방 인적자원관리 방안에 관한 연구 -서울지역 특급호텔 중심으로-)

  • 엄영호
    • Culinary science and hospitality research
    • /
    • v.7 no.2
    • /
    • pp.25-48
    • /
    • 2001
  • Since 1998 IMF economic crisis, hotel companys have made an operation innovation in generally to reinforce a competitive power. Never ther less, a structural depression with high expense of costs-low degree of efficiency and high price of commodities-low degree of growth during the last few years. And hotel companys were doing endeavor for conquer this depression with reshuffle of the personnal system and that systematizing an enterprise and production control. Hotel has more increase personnel expenses percents than increase sold price percents so that hotel reducing cook and as result, hotel has a problem from production selling of foodservice because that is insufficient of cook man power. On studying this research, an importancy of cusine department in inquire hotel and an efficiency man power control of cusine department influence on hotel marketing were made use of analysis for hotel kitchen management. The result of this study is like that. First, the quality of a hotel employee is directly related to that of hotel service, which is functioned as a principle factor on which success or failure of tie hotel very largely depends, Second, fair evaluation of merits. Third, cognition for job as expert. Fourth, the roles and competences of the employees were affected much by the inner or outer environmental changes surrounding the hotel enterprises. Fifth, do not underestimate an intelligent ability and will power of employee, and hotel company have to manage that the employees consult themselves about their things of department and improve with the master sense for job. Sixth, pay increase and intensive system. This system can raise the will to achievement for employee's job, and company can get many benefits from government. Seventh, the employees should be encouraged to have memberships of academic organizations, to actively participate in academic meetings, workshops, conferences, and forums in the area of job performance.

  • PDF

Factors Related to Vision Disturbances in the Elementary School-Age Children (학령기 아동의 시력저하 실태 및 관련 요인)

  • Shin Hee-Sun;Oh Jin-Joo
    • Child Health Nursing Research
    • /
    • v.8 no.2
    • /
    • pp.164-173
    • /
    • 2002
  • The vision disturbances of school-age children has been recognized as and important school health problem. The purpose of this study is to describe the current status of the visual health and to explore the related factors for the decrease in visual acuity in the elementary school age children. The study subjects were 697 children (Boys: 338, Girls: 359) of 4th to 6th grade in two school in urban area. The visual acuity data of the school health examination in 1999 and 2000 were utilized for analysis. The questionnaire for children and parents was used for survey. The findings were as follows. 1. The prevalance rate of the children with the visual acuity less than 0.7 on the left eye were 26.84% ( Grade 4), 31.30% (Grade 5), and 38.39% (Grade 6). The rate on the right eye were 28.31% (Grade4), 30.37% (Grade 5), and 37.92% (Grade 6). There was a significant difference in the rate of the visual acuity less than 0.7 according to grade (p<.01). 2.The rate of visual acuity decrease was 40.12%. 3. The factors related to the decrease in the visual acuity were grade, sex, genetic factor, posture, and the awareness of the visual acuity. There was more decrease in the visual acuity when the children were in higher grade (O.R= 1.06), girls (O.R=2.29). Children having parents with better vision (Father: O.R=1.26; Mother O.R= 1.25) showed better vision. On the other hand, when the children have siblings with glasses, there was more decrease in the visual acuity (O.R=2.31). Students with good posture during study (sitting on the chair) and watching TV to the lower direction showed less decrease in the visual acuity. Also, when the students know their visual acuity, the rate of decrease were lower. The variables which odds ratio were statistically significant were sex (p<.01), siblings with glasses (p <.01), and awareness of visual acuity (p<.01).

  • PDF