• Title/Summary/Keyword: probe design

Search Result 473, Processing Time 0.031 seconds

Design of an electrostatic 2-axis MEMS stage with large area platform (대면적 플랫폼을 갖는 정전형 2 축 MEMS 스테이지의 설계)

  • 정일진;전종업;백경록;박규열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.373-378
    • /
    • 2004
  • Recently the electrostatic 2-axis MEMS stages have been fabricated for the purpose of an application to PSD (Probebased Storage Device). However, most of them have low area efficiency, which is undesirable as data storage devices, since all of the components (springs, comb electrodes, anchors, platform, etc.) are placed in-plane. In this paper, we present a novel structure of electrostatic 2-axis MEMS stage that is characterized by having large area platform. For large area efficiency, the actuator part consisting of mainly comb electrodes and springs is placed right below the platform. In this article, the structures and operational principle of the MEMS stages are described, followed by design procedure, structural and modal analysis using FEM(Finite Element Method). The area efficiency of the MEMS stage was designed to be about 55%, that is very large compared with conventional ones having a few percentage.

  • PDF

Design and manufacture of mini loop coil magnetic curer for peripheral nervous system treatment (말초신경계 치료를 위한 미니 Loop - 코일 삽입형 자기치료시스템의 설계 및 제작)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.153-155
    • /
    • 2007
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Design and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of roof object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse form and treatment pulse form etc. variously Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development Go amplitude treatment pulse (traditional magneto-therapy of greatly great that strong.) does curative effect greatest at short time and becomes thought that demand is magnified greatly at the future in this research.

  • PDF

Design Method of Noise Performance of CMOS Preamplifier for the Active Semiconductor Neural Probe (신경신호 기록용 능동형 반도체 미세전극을 위한 CMOS 전치증폭기의 잡음특성 설계방법)

  • Kim, Kyung-Hwan;Kim, Sung-June
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.209-210
    • /
    • 1998
  • Noise characteristics of preamplifier, the most essential part of on-chip signal processing circuitry for the active semiconductor neural probe, is the important factor determining the overall signal-to-noise-ratio (SNR). We present a systematic design method for the optimization of SNR, based on the spectral characteristics of the electrode, circuit noise and extracelluar action potential. Analytical expression is derived to calculate total output noise power. Output SNR of 2-stage CMOS preamplifier is tailored to meet the given specification while the layout area is minimized.

  • PDF

Effects of Maximum Probe Spacing of Wenner Method on Substation Grounding (변전소 접지설계를 위한 대지저항율 측정시 전극간격이 해석결과에 미치는 영향)

  • Choi, J.K.;Kee, H.C.;Jung, G.J.;Kim, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2355-2357
    • /
    • 1999
  • Estimating equivalent soil model which represents an actual soil structure and its electrical characteristics, is extremely improtant for good substation grounding system design and analysis. Since the equivalent soil model is deduced based on the measured apparent soil resistivity - generally obtained from Wenner's 4-point method, reasonable and accurate measuring technique and procedure guarantee good grounding system design and analysis. The paper aims to show the importance of reasonable enough probe spacing by presenting the influence of soil modelling to estimation and measurement of grounding resistance of substation grounding grid.

  • PDF

The Design of Broadband Patch Antenna with Microstrip Line-Probe Feeder (마이크로스트립 라인-프로브 급전구조를 갖는 광대역 패치 안테나의 설계)

  • 박종열;이윤경;윤현보
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.7
    • /
    • pp.687-692
    • /
    • 2002
  • The design of broadband patch antenna with the new feeder structure is proposed in this paper. The antenna operates in the center frequency 5.8 GHz. Proposed the new feeder structure has also broadband characteristic and reduced antenna size. To confirm broadband characteristic, compared with probe feeder antenna. After designing and manufacturing, the antenna bandwidth enhanced by 34.5 % and the patch size reduced by 45 %.

Design of Pitot-Tube Configuration Using CFD Analysis and Optimization Techniques (CFD 해석 및 최적화 기법을 이용한 피토관 형상설계)

  • Kim, Do-Jun;Cheon, Young-Seong;Myong, Rho-Shin;Park, Chan-Woo;Cho, Tae-Hwan;Park, Young-Min;Choi, In-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.5
    • /
    • pp.392-399
    • /
    • 2008
  • Accurate measurement of speed and altitude of flying vehicles in air data system remains a critical technical issue. A highly reliable Pitot-static probe is required to obtain air data such as total pressure and static pressure. In this study, an analysis of the characteristics of flowfield around the Pitot-static probe was performed by using a Navier-Stokes CFD code. In addition, for the purpose of finding an optimal configuration, a technique based on the response surface method is applied to the problem with design parameters including shape of the nose section and cone angle. It is shown that the optimal configuration fulfills the MIL specification in wider range of high angles of attack.

Design of U-slot Array for OCS Base Station (PCS 기지국용 U-슬롯 어레이 안테나 설계)

    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.1
    • /
    • pp.117-124
    • /
    • 2001
  • In this paper, the design of a U-slot array antenna for PCS base station has been implemented and studied. The U-slot antenna is a single layer type with an antenna volume smaller but a bandwidth lager than the designs utilizing parasitic patches, which exceed 17 % bandwidth, for the probe fed case. Designed U-slot array antenna has stable radiation patterns and an average gain above 12 dB across the PCS frequency band. In this paper, through the designing of a U-slot array antenna, we have presented the availability for PCS base station antenna.

  • PDF

Optimal Design of Electrical Probe of Record Device using Electric Field (전계를 이용한 기억장치 전극의 최적 설계)

  • Lee Sung-Gu;Chol Jae-Hak;Kim Yong-Su;Lee Ju;Choi Seung-Kil
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.899-901
    • /
    • 2004
  • This paper analyzes recording density according to the shape variation of Electric Probe writer, and present a shape design method for improving recording density in perpendicular electric recording device. The gradient of electric field has to be steep to improve recording density because transition region on the media becomes wider when recording. The optimum shape of electrode could be archived by using Response Surface Methodology and 2-Dimensional Finite Element Method.

  • PDF

Implementation of Cost-effective Common Path Spectral Domain Free-hand Scanning OCT System

  • Shoujing Guo;Xuan Liu;Jin U. Kang
    • Current Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.176-182
    • /
    • 2023
  • Optical coherence tomography (OCT) is being developed to guide various ophthalmic surgical procedures. However, the high cost of the intraoperative OCT system limits its availability mostly to the largest hospitals and healthcare systems. In this paper, we present a design and evaluation of a low-cost intraoperative common-path free-hand scanning OCT system. The lensed fiber imaging probe is designed and fabricated for intraocular use and the free-hand scanning algorithm that could operate at a low scanning speed was developed. Since the system operates at low frequencies, the cost of the overall system is significantly lower than other commercial intraoperative OCT systems. The assembled system is characterized and shows that it meets the design specifications. The handheld OCT imaging probe is tested on multilayer tape phantom and ex-vivo porcine eyes. The results show that the system could be used as an intraoperative intraocular OCT imaging device.