• Title/Summary/Keyword: printing technology

Search Result 1,526, Processing Time 0.027 seconds

Fabrication and characteristics of alcohol sensor using Fe2O3 (Fe2O3후막을 이용한 alcohol sensor 제작 및 감응특성)

  • Lee, Y.S.;Song, K.D.;Lee, S.M.;Shim, C.H.;Choi, N.J.;Joo, B.S.;Lee, D.D.;Huh, J.S.
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.77-83
    • /
    • 2002
  • In order to get low cost and portability, semiconductor gas sensor need to have low operating temperature and high sensitivity. $Fe_2O_3$ based sensors which were doped with metal oxide catalysts($MoO_3$, $V_2O_5$, $TiO_2$, and CdO) were fabricated by screen printing method. To improve electrical stability of sensors, the $Fe_2O_3$ sensors were annealed in $N_2$ at $700^{\circ}C$ for 2 hours. The $V_2O_5$ doped $Fe_2O_3$ sensor showed about $80{\sim}90%$ sensitivity at alcohol 1,000 ppm and have good selectivity to hydrocarbon gas and tobacco odors. The fabricated sensor and PIC-chip were employed for portable alarm system.

$CO_{2}$ sensing characteristics of solid electrolyte gas sensor with the sensing membrane prepared by the mixture of alkali metal carbonate and binder (알카리 금속 탄산염과 결착제의 혼합물을 감지물질로 하는 고체전해질 가스센서의 $CO_{2}$ 감응 특성)

  • Chai, Yu-Sug;Song, Kap-Duk;Kang, Bong-Hwi;Seo, Moo-Gyo;Lee, Duk-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.111-116
    • /
    • 1998
  • The simple solid electrolyte carbon dioxide sensor with heaters were fabricated by using Li ionic conductor. Two Au electrodes were used for the reference and sensing electrode respectively. Two types of gas sensors, type ( I ) and type (II), were fabricated. Type ( I ) sensor was fabricated by the method of melting and crystallizing alkali metal carbonate at the temperature of $420{\sim}500^{\circ}C$. The sensing membrane of type (II) sensor was formed by the printing method on sensing electrode after metal carbonate was mixed with binder. The response characteristics of sensors fabricated for the carbon dioxide were investigated for a range of $CO_{2}$ concentration from 950 ppm to 9,950 ppm at operating temperature $420^{\circ}C$. Type ( I ) sensor and type (II) sensor showed the sensitivity of 62 mV/decade and 65 mV/decade respectively. The emf/decade of type (II) sensor tested at $420^{\circ}C$ almost followed the theoretical value of Nernst's equation and showed stable response characteristics with the fast response time of $15{\sim}20$ sec. Also type (II) sensor showed excellent stability and reproduction properties for 60 days.

  • PDF

A Study on Application of Kinetic Typography on the Internet Banner Advertising (인터넷 배너광고에서의 키네틱 타이포그래피의 표현에 관한 연구)

  • Kim, Chang-Rea
    • Archives of design research
    • /
    • v.17 no.4
    • /
    • pp.269-278
    • /
    • 2004
  • Modern high technology has developed from a printing type-oriented culture to sight and hearing-oriented one. Such changes helped raise users' interests and desires on being seen and heard, encouraging research for various usages and types. In particular, with the common use of high speed Internet and firmer standing of Internet as advertising media, Internet banner advertisement has been growing twice as much as the previous year, every year. With this accelerated development of multimedia Kinetic Typography has been used for a variety of forms. During this series of process, the most important one is the expression of the movement of Kinetic Typography. Information able to obtain from the existing way of reading became transferred to the process of multi-dimensional process of obtaining such as seeing and hearing. Accordingly, more effective expression with interesting factors considered together with more activeness for users' obtaining information through Internet, can expect more positive effects. Towards this goal, more various new tries should be made for Internet banner advertisement. In particular, with the larger role in Kinetic Typography to play the role of users' reading for information obtainment, the principles & factors of expression for Internet banner advertisement would be studied, and expression types and structure would be considered, and data from them would be collected and analyzed, to suggest the direction of development.

  • PDF

Synthesis and Water Repellency of Polymers with Fluorinated Alkyl Group and Isocyanate Group (불소화 알킬기와 이소시아네이트기를 가지는 고분자의 합성과 발수성)

  • Baek Chang-Hoon;Kong Jong-Yun;Hyun Seok-Hee;Lim Yong-Jin;Kim Woo-Sik
    • Polymer(Korea)
    • /
    • v.29 no.5
    • /
    • pp.433-439
    • /
    • 2005
  • The copolymers were prepared by the emulsion copolymerization of fluoroalky lacrylate-stearylacrylate-m-isopropenyl-${\alpha},\;{\alpha}'$-dimethylbenzyl isocyanate (TMI) in order to obtain water repellent polymers. The respective copolymerization rates of the three monomers considerably depended upon the use of the nonionic emulsifier and the nonionic-cationic mixed emusifier, and the optimum conditions were obtained. The particle sizes of the copolymers were in the range of 105 to 222nm. The particle sizes of the copolymers prepared by the use of the mixed emulsifiers were smaller than those of the copolymers prepared by the use of the nonionic emulsifier. The reactions of both TMI-N-methyl acetamide and TMI-cellobiose did not take place. However, the reaction of TMI-n-butylamine occurred. The water contact angles before and after washing three times for nylon and poly(ethylene terephthalate) (PET) fabrics coated with the copolymer prepared by the use of mixed emulsifier were about $139^{\circ}\;and\;133^{\circ}$ Therefore, the copolymer showed good durable repellency for nylon and PET.

Measurement of Width and Step-Height of Photolithographic Product Patterns by Using Digital Holography (디지털 홀로그래피를 이용한 포토리소그래피 공정 제품 패터닝의 폭과 단차 측정)

  • Shin, Ju Yeop;Kang, Sung Hoon;Ma, Hye Joon;Kwon, Ik Hwan;Yang, Seung Pil;Jung, Hyun Chul;Hong, Chung Ki;Kim, Kyeong Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.1
    • /
    • pp.18-26
    • /
    • 2016
  • The semiconductor industry is one of the key industries of Korea, which has continued growing at a steady annual growth rate. Important technology for the semiconductor industry is high integration of devices. This is to increase the memory capacity for unit area, of which key is photolithography. The photolithography refers to a technique for printing the shadow of light lit on the mask surface on to wafer, which is the most important process in a semiconductor manufacturing process. In this study, the width and step-height of wafers patterned through this process were measured to ensure uniformity. The widths and inter-plate heights of the specimens patterned using photolithography were measured using transmissive digital holography. A transmissive digital holographic interferometer was configured, and nine arbitrary points were set on the specimens as measured points. The measurement of each point was compared with the measurements performed using a commercial device called scanning electron microscope (SEM) and Alpha Step. Transmission digital holography requires a short measurement time, which is an advantage compared to other techniques. Furthermore, it uses magnification lenses, allowing the flexibility of changing between high and low magnifications. The test results confirmed that transmissive digital holography is a useful technique for measuring patterns printed using photolithography.

Effect of lead-free frit and RuO2 on the electrical properties of thick film NTC thermistors for low temperature co-firing (저온 동시 소성용 후막 NTC 서미스터의 전기적 특성에 미치는 무연계 프릿트 및 RuO2의 영향)

  • Koo, Bon Keup
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.31 no.5
    • /
    • pp.218-227
    • /
    • 2021
  • A thick film NTC thermistor for low temperature co-firing was manufactured by printing and sintering a paste prepared using NTC powder of Mn1.5Ni0.4Co0.9Cu0.4O4 composition, lead free frit, and RuO2 on a 96 % alumina substrate. The effect of frit and RuO2 on the electrical properties of thick film NTC thermistor was studied. The resistance of the thick film NTC thermistor was higher than that of the bulk phase sintered at the same temperature, but it was found that the negative resistance temperature characteristic appeared more clearly and linearly in the resistance - temperature characteristic. On the other hand, the area resistance decreased as the sintering temperature increased, and the area resistance increased as the amount of frit added increased. The B constant of the thick film NTC thermistor was 3000 K or higher. Among them, it was found that the B constant of the thick film NTC thermistor made of paste with 5 wt% of frit added and sintered at 900℃ showed the highest B constant. Also, it can be seen that the area resistance decreased with the addition of RuO2, and the change in the area resistance decrease of the thick film NTC thermistor obtained by sintering the paste containing 5 wt% of RuO2 at 900℃ is the most obvious.

A Study on the Fabrication of bone Model X-ray Phantom Using CT Data and 3D Printing Technology (CT 데이터와 3D 프린팅 기술을 이용한 뼈 모형 X선 팬텀 제작에 관한 연구)

  • Yun, Myeong Seong;Han, Dong-Kyoon;Kim, Yeon-Min;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.879-886
    • /
    • 2018
  • A 3-dimensional (D) printer is a device capable of outputting a three-dimensional solid object based on data modeled in a computer. These features are utilized in the bone model X - ray phantom production etc using CT data by fusing with the radiation science field. A bone model phantom was made using data obtained by CT scan of an existing Pelvis phantom, using PLA, Wood, XT-CF20, Glow fill, Steel filaments which are materials of Fused Filament Fabrication (FFF) 3D printer.Measure Hounsfield Unit (HU) with images obtained by CT scan of the existing Pelvis phantom and five material phantoms made with 3D printer under the same conditions,SI and SNR were measured using a diagnostic X-ray generator, and each phantom was compared and analyzed.As a result, the X - ray phantom in the X - ray examination condition of the limb was found to be most suitable for the glow fill filament.The characteristics of the filament can be known to the base of this research and the practicality of X - ray phantom fabrication was confirmed.

Full-mouth rehabilitation using digital method to transfer provisional restoration to final fixed implant restoration (디지털 방법을 활용하여 임시수복물을 최종 고정성 임플란트 수복물로 이행한 완전 구강 회복 증례)

  • Cho, Eunhan;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock;Noh, Kwantae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.362-373
    • /
    • 2022
  • For a full-mouth fixed prosthetic treatment of the edentulous patient, it is essential to confirm the proper tooth position and thorough evaluation of the remaining alveolar bone and soft tissue before surgery. CAD-CAM dentistry and guided implant surgery have such advantages of providing simultaneous planning of surgery and prosthetic treatment to ensure pre-knowledge of the treatment. In this clinical case, using the digital technology, digital temporary denture fabrication, esthetic evaluation before fixed prostheses treatment, and guided surgery planning was possible. After the surgery, previously obtained data was used for fabricating fixed temporary prostheses. Definitive zirconia prostheses transferred from the provisional prostheses were fabricated and functionally and esthetically satisfying results were obtained.

Expansion of Personal Identification to Vitalize the Use of Unmanned Civil Service Issuing Machines for Gongju-si (공주시 무인민원발급기 이용 활성화를 위한 신분 확인 확대 방안)

  • Kim, Eui Seok;Jung, Hanmin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.156-158
    • /
    • 2021
  • An initial local government center received direct asking from citizens, wrote the documents by hand, and issued them. Later the appearance of computers, printers, and faxes made it possible to handle civil complaints through copying. Since 2010, as the e-government has started, entering civil service requests into computers after identification by themselves and printing the results has become established. In addition, with the introduction of unmanned administrative services, civil services become available in various places, which causes the increased satisfaction of citizens. One of the services is an unmanned civil service issuing machine, and more than 20 kinds of documents, including a copy of resident registration, can be issued directly. Of course, additional help may be needed if citizens are not familiar with the latest technologies. However, the unmanned civil service issuing machine is a highly satisfactory way in that it is less time-limited as citizens can visit a community center or city hall after the end of work. However, the main problem is that resident registration numbers and fingerprint recognition are required depending on the type of issuance, which increases the inconvenience of handling citizen complaints and is shunned. To solve this problem, we aim to study a method for improving the fingerprint recognition method of unmanned civil service issuing machines by expanding personal identification.

  • PDF

Development of electrochemical biosensor for determination of galactose (4갈락토오즈 측정을 위한 전기화학적 바이오센서 개발)

  • Park, Kap Soo;Cho, Soon Sam;Quan, De;Lee, Jae Seon;Cha, Geun Sig;Nam, Hakhyun
    • Analytical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.393-399
    • /
    • 2007
  • In principle, the blood galactose level may be determined conveniently with a strip-type biosensor similar to that for glucose. In this study, we describe the development of a disposable galactose biosensor strip for point-of-care testing. The sensor strip is constructed with screen-printed carbon paste electrode (SPCE) and sample amount (< $100{\mu}L$). The developed strip the galactose level in less than 90 s using bienzymatic system of galactose oxidase (GAO) and horseradish peroxidase (HRP). The effects of pH, mediator (1,1-ferrocenedimethanol) concentration, ratio of enzymes, and applied potential were determined preliminarily with glassy carbon electrodes, and optimized further with the strip-type electrodes. The sensor exhibits linear response in the range of $0{\sim}400{\mu}M$ ($r^2$ = 0.997, S/N = 3). Since a low working potential, in principle, the fabricated disposable galactose biosensor has -100 mV (vs. Ag/AgCl), it is applied for the detection of galactose, interfering responses from common interferents such as ascorbic acid, uric acid and acetaminophen could be minimized. The sensor has been used to determine the total galactose level in standard samples with satisfactory reproducibility (CV = 5 %).