• Title/Summary/Keyword: primary loading

Search Result 366, Processing Time 0.023 seconds

The Calibration Method of Time Resolved Laser Induced Incandescence Using Carbon Black Particles for the Soot Measurement at Exhaust Tail Pipe in Engine (엔진 배기단 적용을 위한 Time Resolved Laser Induced Icandescence (TIRE-LII) 신호의 보정 : 카본 입자 이용)

  • Oh Kwang Chul;Kim Deok Jin;Lee Chun Hwan;Lee Chun Beom
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.12 s.243
    • /
    • pp.1335-1343
    • /
    • 2005
  • The calibration technique of Time Resolved Laser Induced Incandescence was investigated both experimentally and numerically by using standard-sized carbon black particles for the instantaneous soot measurement at exhaust tail pipe in engine. The carbon black particles (19nm, 25nm, 45nm and 58nm) used in this study are similar, though not identical, to soot particle generated from flame not only in morphology but also in micro-structure. The amount of soot loading in flow was controled by a diluted gas (nitrogen) and was measured by the gravimetric method at exhaust pipe in calibrator. The successful calibrations of primary particle size and soot mass fraction were carried out at the range from 19nm to 58nm and from $0.25mg/m^3$ to $37mg/m^3$ respectively. And based on these results the numerical simulation of LII signal was tuned and the effect of an exhaust temperature variation on the decay rate of LII signal was corrected.

Study on the Dynamic Analysis Based on the Reduced System (축소모델 기반 구조물의 동적해석 연구)

  • Kim, Hyung-Gi;Cho, Maeng-Hyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.5
    • /
    • pp.439-450
    • /
    • 2008
  • In this study, the reduced system for the dynamic analysis is proposed and the selection criterion of the primary degrees of freedom is presented considering the relation between natural frequency and external loading frequency. A well-constructed reduced system can assure the accurate representation of the dynamic behavior under arbitrary dynamic loads. For selecting the primary degrees of freedom of the reduced system, we employ the robust two-level condensation scheme of which the reliability has been proven through previous study. In the numerical examples, the reliability of the dynamic analysis based on the reduced system is demonstrated through comparing with those of global system.

Structural Optimization based on Equivalent Static Load for Structure under Dynamic Load (동하중을 받는 구조물의 등가정하중 기반 구조최적화 연구)

  • Kim, Hyun Gi;Kim, Eui young;Cho, Maenghyo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.236-240
    • /
    • 2013
  • Due to difficulty of considering dynamic load in side of a computer resource and computing time, it is common that external load is assumed as ideal static load. However, structural analysis under static load cannot guarantee the safety of structural design. Recently, the systematic method to construct equivalent static load from the given dynamic load has been proposed. Previous study has calculated equivalent static load through the optimization procedure under displacement constraints. And previously reported works to distribute equivalent static load were based on ad hoc methods. However, it is appropriate to take into account the stress constraint for the safety design. Moreover, the improper selection of loading position may results in unreliable structural design. The present study proposes the methodology to optimize an equivalent static which distributed on the primary DOFs, DOFs of the constraint elements, DOF of an external load as positions. In conclusion, the reliability of proposed method is demonstrated through a global optimization.

  • PDF

Clinical Comparison of Immediately Loaded and Delayed Loaded OSSTEM GS III Implant in Partially Edentulous Patients (자연치 부분 결손 환자에서 테이퍼 형태의 국산 임플란트(OSSTEM GS III)의 즉시하중 성공률에 대한 지연하중군과의 비교 임상연구)

  • Kwon, Min-Jung;Kim, Young-Kyun;Yeo, In-Sung;Yi, Yang-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.3
    • /
    • pp.267-275
    • /
    • 2011
  • This prospective study was designed to compare clinical outcomes of immediately loaded implant with delayed loaded implant in partially posterior edentulous patients. For test group, 42 GS III (Osstem, Korea) implants in 17 patients were loaded within 48 hours after the placement. Control group was 27 implants in 15 patients loaded at $2.6{\pm}1.7months$ from the placement surgery. Before loading, primary stability was evaluated by ISQ value. Clinical symptoms, mobility, soft tissue state was evaluated at baseline, 3 months, 6 months and 12 months of loading. Marginal bone level change was also measured with periapical radiographs. Mann-Whitney test (${\alpha}$=0.05) and repeated measured ANOVA (${\alpha}$=0.05) was used for marginal bone level change between two groups. At the baseline, mean ISQ value of test group and control group was $80.3{\pm}7.1$ and $69{\pm}17$ respectively. Test group showed 95.23% of success rate and 100% of control group was successful. At 3 and 6months of loading, significantly more bone resorption was observed in test group than in control group (p<0.05). However, there was no significant difference in the bone level change at 12months of loading between two groups (p>0.05). Marginal bone level change showed no significant difference with gender and location (p>0.05). Within the limitation of this study, when primary stability was obtained, immediate loading of GS III implant at posterior region could be predictable treatment option.

Retrospective clinical study of ultrawide implants more than 6 mm in diameter

  • Ku, Jeong-Kui;Yi, Yang-Jin;Yun, Pil-Young;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.30.1-30.6
    • /
    • 2016
  • Background: The prognosis of wide implants tends to be controversial. While wider implants were initially expected to result in a larger osseointegration area and have higher levels of primary stability, they were reported to have a relatively high rate of failure. The clinical outcome of ultrawide implants of more than 6 mm in diameter was evaluated through a retrospective study. Methods: The investigation was conducted on patients who had received ultrawide implant (${\geq}6mm$ diameter) placements in Seoul National University Bundang Hospital from January 2008 to December 2013. Complications were investigated during the maintenance period, and marginal bone loss was measured using periapical radiography. Primary stability immediately after the implant placement and second stability after second surgery or during impression were measured using $Osstell^{(R)}$ Mentor (Osstell, Sweden) as an implant stability quotient (ISQ). Results: Fifty-eight implants were placed in 53 patients (30 male, 23 female), and they were observed for an average of $50.06{\pm}23.49$ months. The average ISQ value increased from $71.22{\pm}10.26$ to $77.48{\pm}8.98$ (P < 0.005). The primary and secondary stability shows significantly higher at the mandible than at the maxilla (P < 0.001). However, mean survival rate shows 98.28 %. Average marginal bone loss of 0.018 and 0.045 mm were measured at 12 and 24 months after the loading and 0.14 mm at final follow-up date (mean 46.25 months), respectively. Also in this study, the bone loss amount was noticeably small compared to regular implants reported in previous studies. Conclusions: The excellent clinical outcome of ultrawide implants was confirmed. It was determined that an ultrawide implant can be used as an alternative when the bone quality in the posterior teeth is relatively low or when a previous implant has failed.

Evaluation of Age-Hardening Characteristics of Squeeze-Cast A356 Alloy by Using Micro/Nano Indenter with AFM (나노/마이크로 인덴터와 AFM을 이용한 스퀴즈 캐스트 A356 합금의 시효경화특성 평가)

  • Youn S.W.;Kim K.D.;Kang C.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1398-1401
    • /
    • 2005
  • The nano/microstructure, the aging response (in T5 heat treatment), and the mechanical/tribological properties of the eutectic regions in squeeze-cast A356 alloy were investigated using nano/micro-indentation and mechanical scratching, combined wit optical microscopy and atomic force microscope(AFM). Most eutectic Si crystals in the A356 alloy showed a modified morphology as fine-fibers. The loading curve for the eutectic region was more irregular than that of the primary Al region due to the presence of various particles of varying strength. In addition, the eutectic region showed lower pile-up and higher elastic recovery than the primary Al region. The aging responses of the eutectic regions in the squeeze-cast A356 alloys aged at $150^{\circ}C$ for different times(0, 2, 4, 8, 10, 16, 24, 36 and 72 h) were investigated. As the aging time increased, acicular Si particles in the eutectic regions gradually came to a fine structure. Both Vickers hardness ($H_V$) and indentation ($H_{IT}$) test results showed almost the same trend of aging curves, and the peak was obtained at the same aging time of 10 h. A remarkable size-dependence of the tests was found. The friction coefficient for the eutectic region was lower than that for the primary Al region.

  • PDF

Variability of Water Quality and Limiting Factor for Primary Production in Semi-enclosed Masan Bay, South Sea of Korea (한국 남해 마산만에서 수질환경의 계절적 변동과 기초생산 제한인자)

  • Lim, Dhong-Il;Kim, Young-Ok;Kang, Mi-Ran;Jang, Pung-Kuk;Shin, Kyoung-Soon;Jang, Man
    • Ocean and Polar Research
    • /
    • v.29 no.4
    • /
    • pp.349-366
    • /
    • 2007
  • Seasonal variations of various physicochemical components (temperature, salinity, pH, DO, COD, DOC, nutrients-silicate, DIN, DIP) and potential limiting factor for phytoplankton primary production were studied in the surface water of semi-enclosed Masan Bay. Seasonal variations of nutrient concentrations, with lower values in summer and winter, and higher in fall, are probably controlled by freshwater loadings to the bay, benthic flux and magnitude of occurrence of phytoplankton communities. Their spatial distributional patterns are primarily dependent on physical mixing process between freshwater and coastal seawater, which result in a decreasing spatial gradient from inner to outer part of the bay. In the fall season of strong wave action, the major part of nutrient inputs (silicate, ammonium, dissolved inorganic phosphorus) comes from regeneration (benthic flux) at sediment-water interface. During the summer period, high Si:DIN and Si:DIP and low DIN:DIP relative to Redfield ratios suggest a N- and secondarily P-deficiency. During other seasons, however, silicate is the potential limiting factor for primary production, although the Si-deficiency is less pronounced in the outer region of the bay. Indeed, phytoplankton communities in Masan Bay are largely affected by the seasonal variability of limiting nutrients. On the other hand, the severe depletion of DIN (relatively higher silicate level) during summer with high freshwater discharge probably can be explained by N-uptake of temporary nanoflagellate blooms, which responds rapidly to pulsed nutrient loading events. In Masan Bay, this rapid nutrient consumption is considerably important as it can modify the phytoplankton community structures.

The effect of the thread depth on the mechanical properties of the dental implant

  • Lee, Sun-Young;Kim, Sung-Jun;An, Hyun-Wook;Kim, Hyun-Seung;Ha, Dong-Guk;Ryo, Kyung-Ho;Park, Kwang-Bum
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.2
    • /
    • pp.115-121
    • /
    • 2015
  • PURPOSE. This study aimed to evaluate the effect of implant thread depth on primary stability in low density bone. MATERIALS AND METHODS. The insertion torque was measured by inserting Ti implants with different thread depths into solid rigid polyurethane blocks (Sawbones) with three different bone densities ($0.16g/cm^3$, $0.24g/cm^3$, and $0.32g/cm^3$). The insertion torque value was evaluated with a surgical engine. The static compressive strength was measured with a universal testing machine (UTM) and the Ti implants were aligned at $30^{\circ}$ against the loading direction of the UTM. After the static compressive strength test, the Ti implants were analyzed with a Measurescope. RESULTS. The Ti implants with deeper thread depth showed statistically higher mean insertion torque values (P<.001). Groups A and group B had similar maximum static compressive strengths, as did groups C and D (P>.05). After the static compressive strength, the thread shape of the Ti implants with deeper thread depth did not show any breakage but did show deformation of the implant body and abutment. CONCLUSION. The implants with deeper thread depth had higher mean insertion torque values but not lower compressive strength. The deep threads had a mechanical stability. Implants with deeper thread depth may increase the primary stability in areas of poor quality bone without decreasing mechanical strength.

Crack growth and cracking behavior of Alloy 600/182 and Alloy 690/152 welds in simulated PWR primary water

  • Lim, Yun Soo;Kim, Dong Jin;Kim, Sung Woo;Kim, Hong Pyo
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.228-237
    • /
    • 2019
  • The crack growth responses of as-received and as-welded Alloy 600/182 and Alloy 690/152 welds to constant loading were measured by a direct current potential drop method using compact tension specimens in primary water at $325^{\circ}C$ simulating the normal operating conditions of a nuclear power plant. The as-received Alloy 600 showed crack growth rates (CGRs) between $9.6{\times}10^{-9}mm/s$ and $3.8{\times}10^{-8}mm/s$, and the as-welded Alloy 182 had CGRs between $7.9{\times}10^{-8}mm/s$ and $7.5{\times}10^{-7}mm/s$ within the range of the applied loadings. These results indicate that Alloys 600 and 182 are susceptible to cracking. The average CGR of the as-welded Alloy 152 was found to be $2.8{\times}10^{-9}mm/s$. Therefore, Alloy 152 was proven to be highly resistant to cracking. The as-received Alloy 690 showed no crack growth even with an inhomogeneous banded microstructure. The cracking mode of Alloys 600 and 182 was an intergranular cracking; however, Alloy 152 was revealed to have a mixed (intergranular + transgranular) cracking mode. It appears that the Cr concentration and the microstructural features significantly affect the cracking resistance and the cracking behavior of Ni-base alloys in PWR primary water.

A PHOTOELASTIC STRESS ANALYSIS IN MANDIBULAR DISTAL - EXTENSION REMOVABLE PARTIAL DENTURES WITH VARIOUSLY DESIGNEO INDIRECT RETAINERS (간접유치장치 설계변화에 따른 하악유리단 국소의치의 광탄성 응력분석)

  • Kang, Seung-Jong;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.2
    • /
    • pp.183-197
    • /
    • 1990
  • The purpose of this study was to analyse the magnitude and distribution of stresses using a Photoelastic model from and distal - extension removable partial dentures With four designed indirect retainers. The designs of the indirect retainers were as follows : Design No. 1 : Aker's clasp on 1st bicuspid with no indirect retainer. Design No. 2 : Aker's clasp on 1st bicuspid with indirect retainer on canine. Design No. 3 : Extension of the reciprocal arm of Aker's clasp toward incisal rest on canine. Design No. 4 : Connection with the indirect retainer as in No. 2 and extension of reciprocal arm of Aker' s clasp. A photoelastic model was made of the epoxy resin(PL - 1) and hardner(PLH - 1) and coated with plastic cement -1(PC -1) at the lingual surface of the epoxy model and set with chrome - cobalt partial dentures. A unilateral vertical load of 10kg to the right 1st molar and a vertical load of 10kg to the middle portion of the metal bar crossing both the 1st molars of the right and left, were applied. With the use of specially designed jig, fixture; loading device and the reflective circular polariscope, we obtained the following results : 1. When the unilateral vertical load and the vertical load of the middle portion of the metal bar were applied, design No. 2, 3 and 4 exhibited the higher stress concentration at the root apices and their surrounding tissues of the primary and secondary abutment teeth. 2. When the unilateral vertical load applied to design No. 2,3 and 4 the root apices of the primary and secondary abutment teeth and their surrounding tissues and the nonloaded side of edentulous area exhibited and even stress distribution. 3. When the vertical load was applied, the stress concentration fringe in the primary and secondary abutment teeth was in the order of No. 1,4,2 and 3. 4. No.1 and 4 exhibited the higher distrorted stress concentration at the primary teeth and the edentulous area in the nonloaded side. 5. No.2 design reduced the stresses at the apices of the alveoli of the primary abutment teeth bilaterally as well as on the crest of the residual ridge on the nonloaded side. 6. No. 2 design exhibited the most favorable stress distribution.

  • PDF