• Title/Summary/Keyword: pressure waveform

Search Result 160, Processing Time 0.03 seconds

The Prediction of Fatigue Damage for Pressure Vessel Materials using Shear Horizontal Ultrasonic Wave (SH(shear horizontal) 초음파를 이용한 압력용기용 재료의 피로손상 예측)

  • Kang, Yong-Ho;Chung, Yong-Keun;Song, Jung-Il
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.6
    • /
    • pp.90-96
    • /
    • 2009
  • Ultrasonic method using SH(shear horizontal) wave has been developed to determine the surface damage in fatigued material. Fatigue damages based on propagation energy were analyzed by multi-regression analysis in interrupted fatigue test specimen including CrMoV and 12Cr alloy steel. From the test results, as the fatigue damage increased the propagation time of the launched waves increased and amplitude of wavelet decreased. Also, analysis for the waveform modulation showed a reliable estimation, with confidence limit of 97% for 12Cr steel and 95% for CrMoV steel, respectively. Therefore, It is thought that SH ultrasonic wave technique can be applied to determine fatigue damage of in-service component nondestructively.

Dielectric Characteristics of $SF_6$ Gas in Inhomogeneous Field (불평등 전계중에서 $SF_6$가스의 절연특성)

  • Lee, Chang-Jun;Lee, Bok-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1870-1872
    • /
    • 1996
  • This paper presents dielectric characteristics of $SF_6$ gas stressed by the non-oscillating and oscillating impulse voltages in inhomogeneous fields disturbed by metallic protrusion. The propose of this investigation is to present the predischarge development and dielectric characteristics of $SF_6$ gas under VFTOs. The experiments were carried out using a needle-to-plane and two needles-to-plane gap geometries in the gas pressure ranges from 0.1 to 0.5 MPa. The gap separation was 22 mm and the needle-shaped protrusions were made of stainless steel 10 mm in length and 1.0 mm in diameter. As a result, it was found that the breakdown mechanism and predischarge current are principally dependent on applied voltage waveform and polarity.

  • PDF

Real Time Estimation of the Left Ventricular Diastolic Relaxation Rate using Intraventricular Pressure Waveform (압력 파형을 이용한 좌심실 확장 이완율의 실시간 추정)

  • Chun, H.G.;Kim, H.C.;Sohn, D.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.415-419
    • /
    • 1997
  • The left ventricular relaxation rate is used as a golden standard which describes the left ventricular diastolic unction. So far, to get the rate of relaxation one should calculate the data after full recording, that is, off-line method. Therefore one cannot get the rate of relaxation in real-time while changing loading condition or infusing drug. But real time monitoring of the relaxation rate is necessary while changing loading condition or infusing drug to control the mechanics of heart and to get more information. We propose a new criterion to get the left ventricular relaxation rate and a real time algorithm. By comparison, it was turned out that our criterion outperforms others criterion.

  • PDF

Dielectric Characteristics of $SF_6$ Gas Stressed by VFTO in inhomogeneous Field (불평등전계중에서 VFTO에 의한 $SF_6$가스의 방전특성)

  • Lee, B.H.;Lee, C.J.;Ahn, C.H.;Lee, K.O.;Ha, S.C.
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.282-284
    • /
    • 1996
  • This paper presents prebreakdown characteristics of $SF_6$ gas stressed by the non-oscillating and oscillating impulse voltages in inhomogeneous fields disturbed by metallic protrusion. The purpose of this investigation is to present the predischarge development and dielectric characteristics of $SF_6$ gas under VFTOs. The experiments were carried out using a needle-to-plane gap geometries in the gas pressure ranges from 0.1 to 0.5 MPa. The gap separation was22 mm, and the needle-shaped protrusions were made of stainless steel 10 mm in length and 1.0 mm in diameter. As a result, it was found that the breakdown mechanism and predischarge current are principally dependent on applied voltage waveform and polarity.

  • PDF

Characteristics of Magnetic Field Generated by Operating Low Pressure Discharge Lamp (저압방전등의 사용중에 발생하는 자계특성)

  • 이복희;전덕규;길경석;백용현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.05a
    • /
    • pp.63-66
    • /
    • 1994
  • This paper describes the developed sensor for measuring the time-varying magnetic fields and presents the characteristics of the magnetic fields and presents the characteristics of the magnetic field generated by lighting a fluorescent lamp. The frequency bandwidth of magnetic field measurement system is kknown as 40 Hz∼100 kHz by means of calibration experiment. The magnetic field waveform which originates from the various lighting systems was measured and the frequency components were analyzed by fast Fourier transformation technique. The magnetic field generated during the operation of the fluorescent lamp mainly includes the odd harmonics, and in the case\ulcorner of push button switch and high frequency starter types the fast transient component is occurred in an instant of lighting.

  • PDF

Dynamic Property Evaluation of Friction Pendulum Isolation Bearing (마찰진자 베어링의 동적 특성평가)

  • 이경진;김갑순;서용표
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.465-472
    • /
    • 2003
  • The main concept of base isolation system is to reduce the member forces by decreasing the earthquake forces transmitted to superstructure instead of the conventional techniques of strengthening the structural members. There are two important advantages in friction pendulum systems. The functions of carrying the vertical load and of providing horizontal stiffness are effectively separated. This results in a more stable system that eliminates the need of a fail-safe mechanism. Friction pendulum systems are less sensitive to variations in the frequency content of ground excitation and tend to limit the intensity of the farce imparted to the superstructure. This study investigates the friction coefficients on the FPS test specimens according to the velocity, bearing pressure and test waveform.

  • PDF

The Development of Pc Based EGG-NIBP Patient Monitor (PC 기반의 심전도-비관혈식 혈압 환자감시장치의 개발)

  • 김남현;김경하;주기춘;라상원;송광석;한민수;김성민;이건기;최태영
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.4
    • /
    • pp.461-469
    • /
    • 1999
  • In this paper, an ECG-NIBP patient monitor is designed. This is an essential equipment to measure and monitor patient's physical condition - electrocardiogram(ECG) wave, heart rate(HR), and noninvasive blood pressure(NIBP) - in ICU, CCU, and operating room. The ECG is an electrical waveform produced by relaxation and contraction of the cardiac muscle. Most physicians diagnose patient's cardiac states from ECG pattern. A blood pressure is one of the clinical indexes measured in a emergency room or operating room. In this paper, the blood pressure is measured in artery by using the nonivasive oscillometric method. The developed patient monitor was inspected and compared with other instruments in operating rooms. The results were 1bpm of maximum difference in the heart rate, 15mmHg in the systolic pressure, 16mmHg in the diastolic pressure, and 25mmHg in the mean blood pressure. But the total results were 0.15bpm of the mean difference in the heart rate, 5mmHg in the systolic pressure, 10mmHg in the diastolic pressure, and 9mmHg in the mean blood pressure. The designed ECG-NIBP patient monitor can measure the ECG wave, HR, and BP. And the multi-tasking module of pulse oximetry . respiration . temperature monitor will be added in the near future.

  • PDF

Impulse Breakdown Behaviors of Dry Air as an Alternative Insulation Gas for SF6

  • Li, Feng;Yoo, Yang-Woo;Kim, Dong-Kyu;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.3
    • /
    • pp.24-32
    • /
    • 2011
  • [ $SF_6$ ]gas, which has an excellent dielectric strength and interruption performance, is used in various applications such as gas insulated switchgear (GIS) in substations. However, since $SF_6$ has a high global warming potential (GWP), it is necessary to find an eco-friendly alternative insulation gas. In order to examine the possibility of using alternative insulation gases for $SF_6$ in power distribution system equipment, the dielectric strength and physical phenomena of dry air in a quasi-uniform electric field are investigated experimentally in this paper. As a result, the breakdown voltages for positive polarity are higher than those for negative polarity under impulse voltage applications. The negative 50[%] flashover voltage, $V_{50}$ of dry air under conditions above 0.4[MPa] gas pressure, is higher than 150[kV], that is the basic impulse insulation level of distribution equipment. The $V_{50}$ increases linearly with increasing the gas pressure, regardless of the waveform and polarity of the applied impulse voltages. The voltage-time curves are dependent on the rise time of the impulse voltage and gas pressure. Furthermore, streamer discharge was observed through light emission images by an ICCD camera under impulse voltage applications.

Structural Analysis for Constructing a Balloon Type Extracoporeal Membrane Oxygenator using CFD Analysis (CFD 해석을 이용한 Balloon형 인공심폐기 설계를 위한 구조적 해석)

  • Park, Young-Ran;Shim, Jeong-Yeon;Kim, Gi-Beum;Kim, Shang-Jin;Kang, Hyung-Sub;Kim, Jin-Shang;Kim, Min-Ho;Hong, Chul-Un;Kim, Seong-Jong
    • Korean Chemical Engineering Research
    • /
    • v.49 no.2
    • /
    • pp.238-243
    • /
    • 2011
  • In this study, we attempted a structural analysis in order to design a balloon type extracorporeal membrane oxygenator that can induce blood flow without using blood pumps for the purpose of complementing the weakness in the existing extracorporeal membrane oxygenator. To analyze the flow characteristic of the blood flow within the virtual model of extracorporeal membrane oxygenator, computational fluid dynamics(CFD) modeling method was used. The operating principle of this system is to make the surface of the extracorporeal membrane oxygenator keep contracting and dilating regularly by applying pressure load using a balloon, and the 'ime Function Value'that changes according to the time was applied by calculating a half cycle of sine waveform and a cycle of sine.waveform Under the assumption that the uni-directional blood flow could be induced if the balloon type extracorporeal membrane oxygenator was designed as per the method described above, we conducted a structural analysis accordingly. We measured and analyzed the velocity and pressure of blood flow at both inlet and outlet of the extracorporeal membrane oxygenator through CFD simulation. As a result of the modeling, it was confirmed that there was a flow in accord with the direction of the blood by the contraction/dilation. With CFD simulation, the characteristics of blood flow can be predicted in advance, so it is judged that this will be able to provide the most optimized design in producing an extracorporeal membrane oxygenator.

Analysis of the Impact of Reflected Waves on Deep Neural Network-Based Heartbeat Detection for Pulsatile Extracorporeal Membrane Oxygenator Control (반사파가 박동형 체외막산화기 제어에 사용되는 심층신경망의 심장 박동 감지에 미치는 영향 분석)

  • Seo Jun Yoon;Hyun Woo Jang;Seong Wook Choi
    • Journal of Biomedical Engineering Research
    • /
    • v.45 no.3
    • /
    • pp.128-137
    • /
    • 2024
  • It is necessary to develop a pulsatile Extracorporeal Membrane Oxygenator (p-ECMO) with counter-pulsation control(CPC), which ejects blood during the diastolic phase of the heart rather than the systolic phase, due to the known issues with conventional ECMO causing fatal complications such as ventricular dilation and pulmonary edema. A promising method to simultaneously detect the pulsations of the heart and p-ECMO is to analyze blood pressure waveforms using deep neural network technology(DNN). However, the accurate detection of cardiac rhythms by DNNs is challenging due to various noises such as pulsations from p-ECMO, reflected waves in the vessels, and other dynamic noises. This study aims to evaluate the accuracy of DNNs developed for CPC in p-ECMO, using human-like blood pressure waveforms reproduced in an in-vitro experiment. Especially, an experimental setup that reproduces reflected waves commonly observed in actual patients was developed, and the impact of these waves on DNN judgments was assessed using a multiple DNN (m-DNN) that provides accurate determinations along with a separate index for heartbeat recognition ability. In the experimental setup inducing reflected waves, it was observed that the shape of the blood pressure waveform became increasingly complex, which coincided with an increase in harmonic components, as evident from the Fast Fourier Transform results of the blood pressure wave. It was observed that the recognition score (RS) of DNNs decreased in blood pressure waveforms with significant harmonic components, separate from the frequency components caused by the heart and p-ECMO. This study demonstrated that each DNN trained on blood pressure waveforms without reflected waves showed low RS when faced with waveforms containing reflected waves. However, the accuracy of the final results from the m-DNN remained high even in the presence of reflected waves.