• Title/Summary/Keyword: pressure testing

Search Result 1,061, Processing Time 0.025 seconds

Development of Automatic Ultrasonic Testing Techniques of Low Pressure Turbine Blade of Nuclear Power Plants (원자력 발전소 저압 터빈 동익 자동 초음파 검사 기술 개발)

  • Yang, Seung-Han;Lee, Jeong-Bin;Kim, Young-Ho;Yoon, Byung-Sik;Kim, Yong-Sik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.371-377
    • /
    • 2004
  • As the turbine running duration in nuclear power plants increases, cracks have been found in the pin finger type blade root area. The nondestructive examination for the blade root area has been carried out by manual ultrasonic examination during the overhaul period, but because of necessity to improve the reliability, we developed an automatic ultrasonic examination system and technique. To demonstrate the performance of the developed automatic ultrasonic examination system, low pressure turbine blades in the 2nd and 3rd stages of nuclear power plants were examined using the developed system. Its applicability nuclear power plant turbine roots of various types was also confirmed.

Usability Testing of Digital Pressure Bio-feedback for Spinal Rehabilitation Exercise (척추재활운동을 위한 디지털 압력바이오피드백 장치의 사용성 평가)

  • Kim, Tea-Ho;Oh, Do-Bong;Kim, Da-Yeon
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.3
    • /
    • pp.119-126
    • /
    • 2017
  • In the clinical setting, the pressure bio-feedback device is used for the spinal rehabilitation of patients with back pain, but it has several disadvantages. The purpose of this study was to develop a digitalized pressure biofeedback system that provides precise exercise method and posture in real time during the spinal rehabilitation exercise by sensing and monitoring body movements and balance of users and providing biofeedback to users. After that, the usability testing for a digitalized pressure biofeedback system will be conducted to identify problems such as safety, performance, operability, and satisfaction, and suggest improvement directions. A total of 33 subjects were participated in the usability testing. The experts group and the users group evaluated the developed digitalized pressure biofeedback system on a scale of 5 points after using the equipment. In the user group, safety was 3.59, operability was 4.38, satisfaction was 4.49. In the expert group, safety was 2.86, operability was 3.91, and performance was 4.28. Based on the usability evaluation, if the problems of stability of the cradle for tablet PC, air injection, screen display, etc. are solved, it becomes a exercise device capable of accurately exercising and evaluating the function of the spine by checking its own motion state while the spinal stabilization exercise.

Characteristics of wind loads on roof cladding and fixings

  • Ginger, J.D.
    • Wind and Structures
    • /
    • v.4 no.1
    • /
    • pp.73-84
    • /
    • 2001
  • Analysis of pressures measured on the roof of the full-scale Texas Tech building and a 1/50 scale model of a typical house showed that the pressure fluctuations on cladding fastener and cladding-truss connection tributary areas have similar characteristics. The probability density functions of pressure fluctuations on these areas are negatively skewed from Gaussian, with pressure peak factors less than -5.5. The fluctuating pressure energy is mostly contained at full-scale frequencies of up to about 0.6 Hz. Pressure coefficients, $C_p$ and local pressure factors, $K_l$ given in the Australian wind load standard AS1170.2 are generally satisfactory, except for some small cladding fastener tributary areas near the edges.

Studies on the Thin Rubber Coated Fabrics. (Part. 1) Physical Properties of the Coated Fabrics of Natural Rubber and of Butadiene-Styrene Rubber (박막(薄膜) Rubber Coated Fabrics에 관(關)한 연구(硏究) (제1보(第1報)) 천연(天然) 및 합성(合成)고무를 각종(各種) 원반(原反)에 도포(塗布)했을 때의 물리적성능(物理的性能)에 대(對)하여)

  • Kim, Joon-Soo;Lee, Myung-Whan;Yum, Hong-Chan;Lee, Sook-Ja;Rhim, Kwang-Kew
    • Elastomers and Composites
    • /
    • v.1 no.1
    • /
    • pp.41-48
    • /
    • 1966
  • The physical properties of rubber coated fabrics, treated by means of spreading and topping process were studied. 1. The tearing strength of the rubber coated fabrics has shown decreasing tendency in comparison with fabric itself 2. Generally, the tearing strength is inversely proportional to the adhesion. 3. The value of hydrostatic pressure is in proportion to the density and tensile strength of the fabrics. 4. The topping process shows greater difference in adhesion initial and after water immersion than spreading process.

  • PDF

A Study on Structural Analysis of High-Pressure Pipeline Retainer-Type Ball Valve by Pressure Testing of the Industrial Standard (산업용 표준의 압력시험 방법에 의한 고압 배관용 리테이너형 볼밸브의 구조해석에 관한 연구)

  • Kim, Chul Kyu;Yoon, Joon Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.5
    • /
    • pp.13-18
    • /
    • 2015
  • This study has been performed to evaluate the safety of the retainer-type ball valve for a high-pressure pipeline to a district heating plant. The retainer-type ball valve is an improved design for conventional ball valves, such as the floating ball valve and the trunnion ball valve. Numerical analysis of the valve design verification has been applied to investigate the safety factor and seat leakage of the DN300 and DN400 sizes. The given condition to solve the structural analysis was based on the international standard for ISO 5208. In this study, the methods for structural analysis are described in detail. The structural analysis results present the deformations, the equivalent stresses, and the safety factors. Through these results, this study successfully demonstrates the safety and seat leakage of the retainer-type ball valve. They also streamline the process of development for valve manufacturing.

Evaluating the Accuracy of Blood Pressure Measurement (혈압측정의 정확성 평가)

  • Cho, Sung-Hyun;Hwang, Jeong-Hae;Kim, Eun-Gyung;Oh, Byung-Hee;Kim, Chang-Yup
    • Quality Improvement in Health Care
    • /
    • v.3 no.1
    • /
    • pp.94-103
    • /
    • 1996
  • Background : Blood pressure is an important indicator in diagnosis and assessing treatment of a patient. Clinical staffs use blood pressure on the assumption that measured value is accurate and reliable. However, whether measured blood pressure is accurate has been rarely investigated in Korea. Objectives : The aims of this study are to evaluate clinical staffs' knowledge and technique as well as accuracy of sphygmomanometer. Also the program to improve the measurement is developed. Methods : Seventy-three registered nurses were asked nine multiple choice questions including Korotkoff sound, cuff size, and deflation rate. Simultaneously characteristics of nurses were examined, age, working place, duration of employment and academic degree. A testing videotape(Standardizing Measurement Video-Tutored Course) was used for evaluating the accuracy of measurement. Testees were to read and record the 12 cases of blood pressure measurement, watching a falling mercury column and hearing Korotkoff sounds. After 10 minutes' education, they were again tested with the same cases. Additionally, 83 mercury sphygmomanometers were checked to find defects such as inaccurate calibration and zero setting, leaky bladder, etc. Results: For the knowledge testing correct response rate was 41.1%. They were the lowest in selecting the proper cuff size and Korotkoff sound. In examining accuracy of blood pressure with videotape, nurses had 67.7% correct response rate. The correct response rate was significantly improved by a session of education. About 23% of sphygmomanometers was without discernable defects. Conclusion : The knowledge and skill of clinical staffs along with the accuracy of equipment have to be improved. A properly designed education program would contribute to the accuracy improvement of blood pressure measurement. Also, more concerns should be given to the precision and maintenance of equipment.

  • PDF

Agreement of Manual Muscle Testing and Test-Retest Reliability of Hand Held Dynamometer for the Posterior Gluteus Medius Muscle for Patients With Low Back Pain (요통 환자를 대상으로 후중둔근 도수근력검사의 일치도 및 휴대용 근력계 측정 방법의 신뢰도 검사)

  • Park, Kyue-Nam;Kim, Hyun-Sook;Choi, Houng-Sik;Lee, Won-Hwee;Ha, Sung-Min;Kim, Su-Jung
    • Physical Therapy Korea
    • /
    • v.18 no.3
    • /
    • pp.67-75
    • /
    • 2011
  • The purpose of this study was to assess the agreement of manual muscle testing (MMT) and test-retest reliability of a hand held dynamometer for the posterior gluteus medius muscle, with and without lumbar stabilization, using a pressure biofeedback unit for patients with low back pain. The pressure biofeedback unit was used to minimize the substitute motion of the lumbopelvic region during hip abduction in patients lying on their side. Fifteen patients with low back pain participated in this study. A tester determined the MMT grades of the posterior gluteus medius with and without the pressure biofeedback unit. Active hip abduction range of motion with an inclinometer and the strength of their posterior gluteus medius using a hand held dynamometer were measured with and without the pressure biofeedback unit in the MMT position. The agreement of the grade of muscle strength in the MMT, and intra-rater reliability of both the active hip abduction range of motion and the strength of posterior gluteus medius were analyzed using the weighted kappa and intraclass correlation coefficient (ICC), respectively. The agreement of MMT with the pressure biofeedback unit (weighted kappa=.92) was higher than the MMT (weighted kappa=.34)(p<.05). The inclinometer with pressure biofeedback unit measurement of the active hip abduction range of motion had an excellent intra-rater reliability (ICC=.90). Also, the hand held dynamometer with pressure biofeedback unit measure of strength of the posterior gluteus medius had a good intra-rater reliability (ICC=.85). Therefore, the test for muscle strength with pressure biofeedback unit will be a reliable method for the determination of the MMT grades or amount of posterior gluteus medius muscle strength and the measurement of the range of motion for hip abduction in patients with low back pain.

Defects Classification with UT Signals in Pressure Vessel Weld by Fuzzy Theory (퍼지이론을 이용한 압력용기 용접부 초음파 결함 특성 분류)

  • Sim, C.M.;Choi, H.L.;Baik, H.K.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.17 no.1
    • /
    • pp.11-22
    • /
    • 1997
  • It is very essential to get the accurate classification of defects in primary pressure vessel and piping welds for the safety of nuclear power plant. Ultrasonic testing has been widely applied to inspect primary pressure vessel and piping welds of nuclear power plants during PSI / ISI. Classification of flaws in weldments from their ultrasonic scattering signals is very important in quantitative nondestructive evaluation. This problem is ideally suited to a modern ultrasonic Pattern recognition technique. Here, a brief discussion on systematic approach to this methodology is presented including ultrasonic feature extraction, feature selection and classification. A stronger emphasis is placed on Fuzzy-UTSCS (UT signal classification system) as efficient classifiers for many practical classification problems. As an example Fuzzy-UTSCS is applied to classify flaws in ferrite pressure vessel weldments into two types such as linear and volumetric. It is shown that Fuzzy-UTSCS is able to exhibit higher performance than other classifiers in the defect classification.

  • PDF

Testing Investigation of Protective Coatings for Downhole Oil Tube

  • Zhang, Liping;Zhang, Qibin;Zhang, Yanjun;Xie, Beibei;Zhang, Yingying
    • Corrosion Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.13-15
    • /
    • 2008
  • Aiming at the corrosion circumstances and corrosion prevention needs of downhole oil tubes, series protective coatings for downhole oil tubes have been developed in the authors' laboratory, including a baked type coating YG-01 and an air curing type coating YG-03, etc. The performance investigation of the coatings has been done for testing their corrosion resistance, mainly including salt fog test, immersion test in oil-field waste water and various acid solutions, high temperature and high pressure test in alkali solution or $H_2S/CO_2$ environment, as well as some other performances. The investigation results show that oil tube anti-corrosion coatings developed here can endure over 4000 hrs salt fog test, over 1000 hrs immersion in various acid solutions at room temperature and in boiling oil-field waste water. In addition, the coatings can keep intact after experiencing test in alkali solution under 70 MPa pressure at $150^{\circ}C$ for 24 hrs, and in simulative sour gas environment under the total pressure of 32 MPa ($P_{H_{2}S}=3.2MPa$, $P_{CO_{2}}=3.2MPa$) at $90^{\circ}C$ for 168 hrs, which show that the coatings can be used for corrosion prevention in downhole environments with specific high temperature and high pressure, such as sour gas wells. The other testing results show the oil tube protective coatings have excellent comprehensive performance.

Burst pressure tests of axial part-through-wall steam generator tubes (증기발생기 축방향 부분관통균열 전열관의 파열 압력 시험)

  • Lee, Kuk-Hee;Kim, Hong-Deok;Kang, Yong-Seok;Nam, Min-Woo;Cho, Nam-Cheoul
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.10 no.1
    • /
    • pp.56-63
    • /
    • 2014
  • In this research, burst tests for axial notched steam generator tubes were conducted. To measure the burst pressure of notched tubes, a burst testing system was manufactured. The tests were conducted under internal pressure at room temperature. Part-through-wall and through-wall notches which have various geometries with different depths and lengths were machined by electro-discharged-machined(EDM) method. The burst pressure decreased exponentially with increasing notch length and decreased almost linearly with increasing notch depth. A comparison of the burst pressure with existing burst pressure solutions for cracked tube show that the existing solution agree well with the test results.