• Title/Summary/Keyword: pressure safety valve

Search Result 220, Processing Time 0.027 seconds

Property Prediction of Rupture Disc by Using Finite Element Analysis (유한요소해석을 이용한 파열판의 특성 예측)

  • Han, Chang-Yong;Lee, Seong-Beom;Jung, Hee-Suk;Kim, Tae-Gu
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.3
    • /
    • pp.1-6
    • /
    • 2009
  • High pressure devices are used widely. Interest in rupture disc to people is the increases in protect of facilities and people. A rupture disc consists of mainly three parts: holder, plate and vacuum support. Rupture discs are rusted or destroyed by diverse environments. Rupture discs are made from STS 316L stainless steel because of its high corrosion resistance and yield strength. In this study, modeling of a rupture disc by CATIA V5 and finite element analysis by ANSYS were carried out. The finite element analysis results executed to predict properties of the rupture disc with thickness and height.

  • PDF

Proposal of Analyis Method for PICV Characteristics Curve Using CFD in Hydronic System (밀폐형 수배관시스템에서 CFD를 활용한 복합밸브 특성곡선 해석 방법 제안)

  • Do, Gahyeon;Kim, Jinho;Park, Woopyeng;Min, Joonki
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.2
    • /
    • pp.20-29
    • /
    • 2021
  • In this study, it is proposed that an analysis method using charatersistics curve of PICV in the CFD simulation for hydronic system. From the results, the pressure drop characteristics appeared in the region of PICV at a specified flow rate. And the CFD results are in good agreement with the experimental results. Proposed analysis method is proved that the characteristics of PICV applied to the hydronic system were properly applied in the flow analysis. This result can be applied to PICV in the complex hydronic systems. Therefore, the optimal selection of PICV in hydronic system contribute the building energy saving.

The Reasonable SIL Determination by LOPA for HIPS Design of Flare Stack (LOPA분석에 의한 Flare Stack용 HIPS의 합리적 SIL결정)

  • Park, Jinhyung;Park, Kyoshik
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.221-221
    • /
    • 2023
  • 1969년에 발간된 API521 1st edition에서는 Flare Load 저감용으로 적용되는 HIPS (High Integrity Protection System)는 모두 Pressure Safety Valve의 고장확률보다 낮은 SIL 3 (Safety Integrity Level)등급을 적용할 것을 요구하고 있다. Flare Stack 저감용 HIPS는 주로 압축기 출력압력상승, Reboiler Steam 과다주입, 전력공급중단냉각펌프고장 등에 의한 Flare 발생을 예방하기 위한 기능을 가진 SIF (Safety Instrumented Function)로 구성된다. 하지만 2007년도 발간된 API521 5th edition에서는 LOPA (Layer Of Protection Analysis) 분석을 통해 Target SIL을 도출하는 것으로 요구사항을 변경했다. 이에 따라 이번 연구에서는 Flare Load에 가장 큰 영향을 미치는 시나리오 중 대표적인 시나리오를 대상으로 HAZOP(Hazard and Operability Study)과 LOPA분석을 실시해서 Target SIL이 어떻게 도출되는지를 연구했다. Flare Stack에서 Flare를 발생시키는 대표적인 시나리오들에 대해 LOPA분석을 실시한 결과 압축기 출력압력상승은 SIL 2, Reboiler Steam 과다주입은 SIL 3, 전력공급중단은 SIL 0, 냉각펌프고장은 SIL 0로 모두가 SIL 3 가 나오지는 않았다. SIF 설계 시 Target SIL을 만족시키는 것도 중요하지만 운전 시 SIL 등급이 계속 유지되게 하지 위해 인적오류, 시스템적 고장, 하드웨어고장 등에 의해 SIF 기능불능화가 되는 것을 예방하기 위한 기능안전관리시스템 (FSMS)를 적용하는 것도 중요하다.

  • PDF

Performance of Decompression Orifices Attached to Indoor Hydrant Discharge Outlets (옥내소화전 방수구에 부착되는 감압오리피스의 감압성능에 관한 연구)

  • Park, Bong-Rae;Lee, Meng-Ro;Jang, Kyung-Nam;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.29 no.3
    • /
    • pp.6-12
    • /
    • 2015
  • Indoor hydrant facilities are used to fight initial fires before more intense fire extinguishing activities. Fire extinguishing facilities should ensure good fire extinguishing performance and the safety of users. Indoor hydrant facilities are mostly installed in buildings and facilities, and users must manipulate valves, hoses, and nozzles manually. When the discharge pressure is higher than 0.70 MPa, there is a high possibility that problems with manipulation and hose breakdown can occur. To prevent these problems, a method to attach orifice-type decompression valves to the angle valves of indoor hydrant discharge outlets has frequently been used for decompression methods. However, the decompression performance was reduced due to structural problems of the decompression valves over time. Accordingly, based on three-stage initial pressures, applicable pressure ranges were selected by measuring the decompression performance according to the diameter of the decompression orifices. Based on the data, stable decompression valve models are proposed. These models have the lowest decrease in decompression performance, regardless of time.

The Development of Straddle Packer Hydraulic Testing Equipment to Characterize Permeability in Deep Boreholes (장심도 시추공 정밀수리시험 장비 구축)

  • Kim, Kyung-Su;Park, Kyung-Woo;Ji, Sung-Hoon
    • The Journal of Engineering Geology
    • /
    • v.20 no.2
    • /
    • pp.213-220
    • /
    • 2010
  • The permeability characterization on the natural barrier for deep geological disposal of radioactive waste is very critical to evaluate total safety and performance assessment of disposal site. However, the confidence level in using previous hydraulic testing equipments consist of simple components to estimate rock mass permeability is not high enough to reflect in situ condition. The purpose of this research is to establish an advanced hydraulic testing equipment, which is applicable to deep borehole (up to 1,000 m), through the improvement of technical problems of previous packer systems. Especially, the straddle packer hydraulic testing equipment was designed to adopt both the hydraulic downhole shut-in valve(H-DHSIV) to minimize the wellbore storage effect and the real time data acquisition system to measure the pressure changes of test interval including its upper and lower parts. The results from this research lead to not only improve current technical level in the field of hydraulic testing but also provide important information to radioactive waste disposal technology development and site characterization project.

Experiment Study on Field Applicability of Siphon as a Intake Facility of Agricultural Reservoir for Disaster Prevention (재해대비 농업용저수지 취수시설로서 사이폰의 현장적용성에 관한 실험적 연구)

  • Yang, Young Jin;Lee, Tae Ho;Oh, Sue Hoon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.2
    • /
    • pp.103-110
    • /
    • 2018
  • Most of the intake facilities of small agricultural reservoirs are conduits and they are regarded as serious defects due to the structural weakness that penetrates the body of the dam, and countermeasures are needed. This study suggests the application method of siphon type water intake facility by hydraulic model test and physical scale model test of siphon type water intake facility which has high safety and easy maintenance. Experimental results show that sufficient flow rate can be secured for the purpose of intaking water according to the differential head between the reservoir and the discharge part, and the flow rate can be controlled by the valve. The negative pressure was -31.5 kPa, and vibration and noise did not occur during the operation of the siphon. The maximum flow velocity in the discharge outlet was 1.11 m/s which meets the criterion for irrigation canals. Therefore, scour risk would be very low. As a result of the inflow distribution experiment, even if the inflow part is separated by only about 0.8 m, the flow velocity is remarkably decreased, so that the clogging by debris would not appear. When the pump was operated only once for the first time and the inside of the siphon was filled with water, continuous operation was possible by only valve operation. The results of this study are expected to be used for the design guidelines of the water intake facilities and improve safety and maintenance convenience of agricultural reservoirs.

An Analytical Study on the Improvement of the Performance of Swivel Valve Tube Couplers (스위벨 밸브 튜브 커플러 개발을 위한 해석 연구)

  • Lee, Jun-Ho;Sung, Jae-Kyeong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.3
    • /
    • pp.1-6
    • /
    • 2011
  • This study focused on the localization of swivel type tube couplers, which all depend on imports. In this study, a computer application analysis was performed using a finite element method as a preliminary study. In the major developments related to the objective of this study, the air brake system produced by car makers represents a different in the installation point of an air tank according to the type of cars or in the length and direction of its hoses and that leads to cause lots of problems. For solving such problems, the design of the major elements in a swivel type tube coupler was analyzed using a finite element method, and its validity was also verified. In the process that verifies the validity of this study, it was necessary to investigate how much external force affects the desorption of the tube support, which is the most important element in swivel type tube couplers. For achieving the investigation, a pressure test was implemented for the tube support according to the Federal Motor Vehicle Safety Standards(FMVSS). In the results of the pressure test, all samples satisfied the FMVSS. In addition, several tests were implemented by installing the sample of the developed swivel type tube coupler to an actual vehicle. In particular, rotation tests with various angles were applied by welding the swivel type coupler to an air tank through an argon welding process. In the results of the installing test for an actual vehicle, it was verified that the designed structure was determined as a structure that is able to endure the eccentric torque and deformation pressure applied to several directions that are the major problems in such fixed type tube couplers. Therefore, in the comparison of the performance of the developed product with the product of PARKER, it was possible to verify that the localized swivel type tube coupler developed in this study shows more excellent than that of the existing products by PARKER.

Cost-Benefit Analysis in order to Select the Reasonably Practical Risk Reduction Measures(RRMs) on High Pressure Urban Gas Pipelines (도시가스 고압배관의 합리적인 위험감소조치 선정을 위한 비용-편익분석)

  • Ryou, Young-Don;Kim, Young-Seob;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.2
    • /
    • pp.40-46
    • /
    • 2011
  • The purpose of CBA(cost-benefit analysis) in risk assessment is to show whether the benefits of implementing additional risk reduction methods(RRMs) derived through risk assessment outweigh its costs and it is proper to implement the methods. In this paper CBA has been conducted in order to select the most effective and reasonable RRM as implementing the RRM derived after QRA for the high pressure urban gas pipelines. As conducting QRA again by applying the derived RRMs, No. 10 measure which includes pipeline corrosion monitoring, MOV(motor operated valve) installation and the method to protect pipeline damage caused by third-party mechanical interference has showed the highest risk reduction effect. Also it has been considered to be reasonably practicable by conducting CBA and then is selected as the most effective and reasonable RRM on the objects of this paper.

Risk Assessment and Safety Measures for Methanol Separation Process in BPA Plant (BPA 공장의 메탄올 분리공정에서 위험성 평가 및 안전대책)

  • Woo, In-Sung;Lee, Joong-Hee;Lee, In-Bok;Chon, Young-Woo;Park, Hee-Chul;Hwang, Seong-Min;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.3
    • /
    • pp.22-28
    • /
    • 2012
  • For a methanol separation column of the BPA (Bisphenol A) plant, HAZOP (hazard and operability) assessment was performed and damage ranges were predicted from the accident scenarios for the fire and the explosion. As a result, the damage range of the jet fire was 20 m in the case of rupture of the discharge pipe (50 mm diameter) of safety valve, and that of the flash fire was 267 m in the case of catastrophic rupture. Also, the damage ranges of the unconfined vapor cloud explosion (UVCE) for the rupture of the discharge pipe and for the catastrophic rupture were 22 m and 542 m, respectively. For the worst case of release scenarios, safety measures were suggested as follows: the pressure instruments, which can detect abnormal rise of the internal pressure in the methanol separation column, should be installed by the 2 out of 3 voting method in the top section of the column. Through the detection, the instruments should simultaneously shut down the control and the emergency shut-off valves.

A Theoretical Analysis of the Weak Shock Waves Propagating through a Bubbly Flow (기액 이상류를 전파하는 약한 충격파에 관한 이론해석적 연구)

  • Jun, Gu-Sik;Baek, Seung-Cheol;Kim, Heuy-Dong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1617-1622
    • /
    • 2004
  • Two-phase flow of liquid and gas through pipe lines are frequently encountered in nuclear power plant or industrial facility. Pressure waves which can be generated by a valve operation or any other cause in pipe lines propagate through the two-phase flow, often leading to severe noise and vibration problems or fatigue failure of pipe line system. It is of practical importance to predict the propagation characteristics of the pressure waves for the safety design for the pipe line. In the present study, a theoretical analysis is performed to understand the propagation characteristics of a weak shock wave in a bubbly flow. A wave equation is developed using a small perturbation method to analyze the weak shock wave through a bubbly flow with comparably low void fractions. It is known that the elasticity of pipe and void fraction significantly affect the propagation speed of shock wave, but the frequency of relaxation oscillation which is generated behind the shock wave is not strongly influenced by the elasticity of pipe. The present analytical results are in close agreement with existing experimental data.

  • PDF