• 제목/요약/키워드: pressure jump

검색결과 77건 처리시간 0.027초

On the numerical simulation of perforated bluff-bodies: A CFD study on a hollow porous 5:1 rectangular cylinder

  • Xu, Mao;Patruno, Luca;Lo, Yuan-Lung;de Miranda, Stefano;Ubertini, Francesco
    • Wind and Structures
    • /
    • 제34권1호
    • /
    • pp.1-14
    • /
    • 2022
  • In this work the flow through a hollow porous 5:1 rectangular cylinder made of perforated plates is numerically investigated by means of 2D URANS based simulations. Two approaches are adopted to account for the porous surfaces: in the first one the pores are explicitly modeled, so providing a detailed representation of the flow. In the second one, the porous surfaces are modeled by means of pressure jumps, which allow to take into account the presence of pores without reproducing the flow details. Results obtained by using the two aforementioned techniques are compared aiming at evaluating differences and similarities, as well as identifying the main flow features which might cause discrepancies. Results show that, even in the case of pores remarkably smaller than the immersed body, their arrangement can lead to local mechanisms able to affect the global flow arrangement, so limiting the accuracy of pressure jumps based simulations. Despite that, time-averaged fields often show a reasonable agreement between the two approaches.

박스형 모델에 의한 슬로싱 하중에 관한 실험적 연구 (An Experimental Study on Rectangular Box Sloshing)

  • 정동우;전수성;박준수;권순홍;장택수
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.386-391
    • /
    • 2006
  • This study presents experimental results of sloshing phenomenon done on rectangular box. A simple harmonic excitation was done on the box. Two kinds of filling ratio, 20% and 30% of height, were tested. A total of 15 pressure sensors were installed to monitor the impact pressure. Each test was repeated for 20 times to ensure the repeatability. The high speed camera captured the flaw filed and the corresponding pressure were synchronize with video signal so that the video image can help the interpretation of the impact pressure. The two filling ratio made difference in the flaw characteristic and impact pressure. The use of high speed camera made it possible to understand the bubble generation mechanism. The pressure time histories were presented.

  • PDF

토러스형 돌기의 흡착접촉 유한요소해석 (Finite Element Analysis of Adhesive Contact of Torus-Shaped Bumps)

  • 조성산;양승민
    • Tribology and Lubricants
    • /
    • 제18권4호
    • /
    • pp.249-254
    • /
    • 2002
  • Adhesive contact characteristics of torus-shaped bumps were analyzed using the finite element technique considering the adhesive force. Analyses focused on the effect of rim and bump radii on the adhesive contact behavior such as the jump-to-contact behavior, adhesion hysteresis, pull-off forces, contact region and pressure, and surface and subsurface stresses. Analysis results in the absence of adhesive force were also included to examine the effect of adhesive force. The applicability of torus-shaped bumps to the MEMS structure for reduction of friction is discussed.

토러스 형상 돌기의 흡착특성 유한요소해석

  • 조성산;양승민
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 제35회 춘계학술대회
    • /
    • pp.179-184
    • /
    • 2002
  • Adhesive contact characteristics of torus-shaped bumps, which are commonly used to reduce friction and stiction in hard disks, are analyzed to examine the applicability to the MEMS structure. The analysis is conducted with the finite element technique considering the adhesive force. Torus-shaped bumps of various rim and bump radii are analyzed. The jump-to-contact behavior, adhesion hysterisis, pull-off forces, contact region and pressure, and surface and subsurface stresses are presented and discussed. Analysis results in the absence of adhesive force are also presented to identify the effect of adhesive force.

  • PDF

A UNIFIED STABILIZED FINITE VOLUME METHOD FOR STOKES AND DARCY EQUATIONS

  • Boukabache, Akram;Kechkar, Nasserdine
    • 대한수학회지
    • /
    • 제56권4호
    • /
    • pp.1083-1112
    • /
    • 2019
  • In this paper, we present and analyze a cell-centered collocated finite volume scheme for incompressible flows to compute solutions simultaneous to Stokes and Darcy equations by applying a pressure jump stabilization term to avoid locking. We prove that the new stabilized FV formulation satisfies a discrete inf-sup condition and error estimates for both problems. Finally, we present some numerical examples confirming this analysis.

2007년 3월 31일 서해에서 발생한 기상해일에 대한 기상학적 분석 (Atmospheric Analysis on the Meteo-tsunami Case Occurred on 31 March 2007 at the Yellow Sea of South Korea)

  • 김현수;김유근;우승범;김명석
    • 한국환경과학회지
    • /
    • 제23권12호
    • /
    • pp.1999-2014
    • /
    • 2014
  • A meteo-tsunami occurred along the coastline of South Korea on 31 March 2007, with an estimated maximum amplitude of 240 cm in Yeonggwang (YG). In this study, we investigated the synoptic weather systems around the Yellow sea including the Bohai Bay and Shandong Peninsula using a weather research and forecast model and weather charts of the surface pressure level, upper pressure level and auxiliary analysis. We found that 4-lows passed through the Yellow sea from the Shandung Peninsula to Korea during 5 days. Moreover, the passage of the cold front and the locally heavy rain with a sudden pressure change may make the resonance response in the near-shore and ocean with a regular time-lag. The sea-level pressure disturbance and absolute vorticity in 500 hPa projected over the Yellow sea was propagated with a similar velocity to the coastline of South Korea at the time that meteo-tsunami occurred.

배플에 의한 개방챔버 내부 유동의 영향에 관한 연구 (A Study on Effects of the Fluid Flow Inner the Open Chamber by Baffle)

  • 노병수;최주열;정하균;최상범
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권3호
    • /
    • pp.255-260
    • /
    • 2015
  • 플래시증발현상은 개방챔버 내의 온도, 압력, 수위 그리고 배플 등에 영향을 받는다. 이 연구에서 PIV 실험은 최적의 배플 위치와 높이에 대한 개방챔버 내의 유동특성을 확실하게 시행하였다. 배플은 개방챔버 내의 재순환 흐름, 수력 도약 그리고 유동특성에 상당한 영향을 주었다. 그리고 레이놀즈수의 영향은 미미하였다. 최적의 배플높이는 h/H=1.5였고, 최적의 배플위치는 개방챔버 내부 입구로부터 x/H=1.5부근 이었다.

Reflections of shocks in nonequilibrium flow of air

  • Park, Tae-Hoon
    • 대한수학회논문집
    • /
    • 제10권3호
    • /
    • pp.767-781
    • /
    • 1995
  • In this paper we present computation of a reflected shock in the hypersonic flow of air with chemical reactions. We consider two dimensional steady inviscid hypersonic flow of air around bodies including chemical reaction effects. At a high Mach number, a strong shock is formed in front of the body when a wedge is placed against the flow. In front of the shock, temperature and pressure increase greatly and the flow is in nonequilibrium state. If the shock hits a wall, then a reflected shock is formed in the nonequilibrium flow region. Behind this reflected shock, the temperature and pressure are very high. We carry out the computation of the reflected shock and the flow behind it. The jump conditions at the reflected shock are presented. A technique combining smooth transforms of domain and implicit difference methods is used to overcome numerical difficulties associated with the lack of resolution behind the shock and near the body.

  • PDF

STABILIZED-PENALIZED COLLOCATED FINITE VOLUME SCHEME FOR INCOMPRESSIBLE BIOFLUID FLOWS

  • Kechkar, Nasserdine;Louaar, Mohammed
    • 대한수학회지
    • /
    • 제59권3호
    • /
    • pp.519-548
    • /
    • 2022
  • In this paper, a stabilized-penalized collocated finite volume (SPCFV) scheme is developed and studied for the stationary generalized Navier-Stokes equations with mixed Dirichlet-traction boundary conditions modelling an incompressible biological fluid flow. This method is based on the lowest order approximation (piecewise constants) for both velocity and pressure unknowns. The stabilization-penalization is performed by adding discrete pressure terms to the approximate formulation. These simultaneously involve discrete jump pressures through the interior volume-boundaries and discrete pressures of volumes on the domain boundary. Stability, existence and uniqueness of discrete solutions are established. Moreover, a convergence analysis of the nonlinear solver is also provided. Numerical results from model tests are performed to demonstrate the stability, optimal convergence in the usual L2 and discrete H1 norms as well as robustness of the proposed scheme with respect to the choice of the given traction vector.

Correlation between the Pressure Pain Threshold and Sonography and Spontaneous Electrical Activity in Myofascial Trigger Points

  • Kim, Hyun-Jin;Kim, Myung-Hoon;Kim, Su-Hyon;Oh, Seok;Choi, Ji-Ho;Kim, Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • 제22권3호
    • /
    • pp.17-21
    • /
    • 2010
  • Purpose: This study was designed to investigate possibilities for quantitative analysis using the electromyography and sonography. For better understanding, we evaluated the correlation between the pressure pain threshold and sonography, spontaneous electrical activity in trigger points located in the upper trapezius muscle. Methods: Thirty three active subjects volunteered to participate in this study (n=33). They had a palpable taut band, exquisite spot tenderness of a nodule in a taut band, spontaneous pain, referred pain, jump sign, local twitch response, and a painful limit to full stretch range of motion. We measured Pressure pain threshold, density, white area index, root mean square, and reaction. Pearson’s correlation coefficient was calculated to estimate the relationship between the pressure pain threshold and other variables including density, white area index, root mean square, and reaction time. Results: There were significant correlations between pressure pain threshold and density (r=-0.75, p<0.01), and between pressure pain threshold and white area index (r=-0.74, p<0.01). A significant correlations between pressure pain threshold and root mean square (r=-0.59, p<0.01). The significant correlation was found between pressure pain threshold and reaction time (r=-0.64, p<0.01). Conclusion: These should indicate whether quantitative analysis can be done using the characteristics of electromyography and sonography.