Journal of Advanced Marine Engineering and Technology
/
v.32
no.3
/
pp.430-436
/
2008
Recently, there are many cases to use a ship's engine performance analyzer(SEPA) to measure pressure in cylinder and top dead center(TDC) of piston of engine, and analyze its performance such as fuel injection time and horsepower as well as wear of piston ring. But, SEPA needs TDC pulses($T(1){\sim}T(n)$) generated when pistons of engine are located to the TDC position ($TDC(1){\sim}TDC(n)$), these pulses are gathered from sensors connected to gear wheel of the propeller shaft in the remote distance from the measurement point. Therefore, operators need a long wire cable(WRC) to TDC detecting sensor to get these pulses, but this method is a very uncomfortable and expensive in case of installation, and it might decrease user's purchase desire. In this paper, we design and fabricate a small and inexpensive MODEM cable(M0C) so that it may be available to transmit TDC pulse generated from sensor in propeller shaft through existing power line. We also verify the facts that this MOC can be applied to SEPA and the effectiveness of the system through the experiments.
Xiphodynia is a term used to describe a painful xiphoid process, and this is a rare musculoskeletal disorder that can radiate to the anterior chest, epigastrium, neck, shoulders and back. Clinical awareness of xiphodynia is important for making its correct diagnosis. We report here on two cases of xiphodynia. The diagnosis was suggested by the reproduction of the anterior chest pain or/and the epigastrium pain with light pressure on the xiphoid process. The patient of case 1 had suffered from xiphodynia throughout the years, and this patient underwent surgical excision of the xiphoid process. The patient of case 2 received an injection of local anesthetic agent to the xiphoid process.
The compressibility of fracture in naturally fractured reservoir is larger than the compressibility of matrix in rock, although the compressibility of a typical rock is very small. The effective compressibility including the fracture compressibility should be considered to predict oil recovery correctly. It is hard to quantify changes of fracture aperture and pore volume in reservoir without the effective compressibility. In this study, oil recovery is analyzed by commercial simulator concerning the fracture compressibility based on fracture properties. We found that the effective compressibility affects oil recovery with change of polymer flooding factors such as polymer molar weight, concentration and injection rate. The estimated cumulative oil production is smaller with the effective compressibility than without it. Also, bottomhole pressure decreases rapidly without considering effective fracture compressibility.
Transactions of the Korean Society of Automotive Engineers
/
v.16
no.1
/
pp.14-21
/
2008
Synthetic gas is defined as reformed gas from hydrocarbon-based fuel and the major chemical species of the synthetic gas are $H_2$, CO and $N_2$. Among them, hydrogen from synthetic gas is very useful species in chemical process such as combustion. It is a main reason that many studies have been performed to develop an effective reforming device. Furthermore, other technologies have been studied for synthetic gas application, such as the ESGI(Exhaust Synthetic Gas Injection) technology. ESGI injects and burns synthetic gas in the exhaust pipe so that heat from hydrogen combustion helps fast warmup of the close-coupled catalyst and reduction of harmful emissions. However, it is very hard to understand combustion characteristic of hydrogen under low oxygen environment and complicated variation in chemical species in exhaust gas. This study focuses on the characteristics of hydrogen combustion under ESGI operating conditions using a CVC(Constant Volume Chamber). Measurements of pressure variation and flame speed have been performed for various oxygen and hydrogen concentrations. Results have been analyzed to understand ignition and combustion characteristics of hydrogen under lower oxygen conditions. The CVC experiments showed that under lower oxygen concentration, amount of active chemicals in the combustion chamber was a crucial factor to influence hydrogen combustion as well as hydrogen/oxygen ratio. It is also found that increase in volume fraction of oxygen is effective for the fast and stable burning of hydrogen by virtue of increase in flame speed.
Park, Soo-Seog;Jang, Yeon;Cho, Eun-Chung;Jee, Seung-Eun;Song, Ho-Kyung;Jung, Sung-Woo
The Korean Journal of Pain
/
v.11
no.2
/
pp.338-342
/
1998
Postural headache due to spontaneous intracranial hypotension occurs without any diagnostic lumbar puncture, myelography, cranial or spinal injury, or spinal anesthesia. The clinical characteristics of the syndrome are disappearance of the headache or a notable decrease in its severity with recumbency, the finding of meningeal enhancement and subdural fluid collection on brain MRI, the pleocytosis and the increased CSF protein concentration. We report a case of a 40-year-old woman who exhibited the signs and symptoms of postural headache due to low CSF pressure. Her headache started suddenly at the occiput and radiated to frontal head. Magnetic resonance imaging (MRI) of her brain showed enhancement of the meninges and subdural fluid collection. Intrathecal radionuclide cisternography showed the delayed appearance of the isotope in the cranium and the minimal CSF leak at the left upper thoracic region. Her headache was relieved completely after a lumbar (L2-L3) epidural injection of 12 ml of autologous blood and remained asymptomatic.
Although sound intensity is considered as one of important factors in auditory processing, its neural mechanism in auditory neurons with limited dynamic range of firing rates is still unclear. In this study, we examined the effect of sound intensity adaptation on the change of glucose metabolism in a rat brain using [F-18] micro positron emission tomography (PET) neuroimaging technique. In the experiment, broadband white noise sound was given for 30 minutes after the [F-18]FDG injection in order to explore the functional adaptation of rat brain into the sound intensity levels. Nine rats were scanned with four different sound intensity levels: 40 dB, 60 dB, 80 dB, 100 dB sound pressure level (SPL) for four weeks. When glucose uptake during the adaptation of a high intensity sound level (100 dB SPL) was compared with that during adaptation to a low intensity level (40 dB SPL) in the experiment, the former induced a greater uptake at bilateral cochlear nucleus, superior olivary complexes and inferior colliculi in the auditory pathway. Expectedly, the metabolic activity in those areas linearly increased as the sound intensity level increased. In contrast, significant decrease interestingly occurred in the bilateral auditory cortices: The activities of auditory cortex proportionally decreased with higher sound intensities. It may reflect that the auditory cortex actively down-regulates neural activities when the sound gets louder.
Proceedings of the Korean Society of Propulsion Engineers Conference
/
2011.11a
/
pp.981-984
/
2011
A high-resolution numerical study is carried out to investigate the transient process of the combustion and the shock-train developments in an ethylene-fueled direct-connect dual-mode scramjet combustor. Following the fuel injection, air-throttling is applied at the expansion part of the combustor to provide mass addition to block the flow to subsonic speed. The ignition occurs several ms later when the fuel and air are mixed sufficiently. The pressure build up by the combustion leads to the shock train formation in the isolator section that advances to the exit of the intake nozzle. Then, the air-throttling is deactivated and the exhaust process begins and the situation before the air-throttling is restored. Present simulation shows the detailed processes in the dual-mode scramjet combustor for better understanding of the operation regimes and characteristics.
Clonidine, ${\alpha}2$-adrenergic agonist, applied spinally or epidurally has been shown to be effective in blocking noxious stimuli in human applications. The purpose of this study is to evaluate the analgesic effect of epidurally administered clonidine. In 40 patients undergoing hemorrhoidectomy or anal fistulectomy, 1.33% lidocaine 15ml (Group I) or 1.33% lidocaine mixed with $75{\mu}g$ clonidine(Group II) administered epidurally through sacral hiatus. Intraoperative changes of vital signs and duration of postoperative analgesic effects were observed. The results were as follows : 1) In the group I, average analgesic duration was 2.42 hours. 2) In the group II, average analgesic duration was 7.32 hours. 3) After epidural clonidine injection, the decrease in heart rate and blood pressure was not significant without sedation. 4) Postoperatively, any complaints related clonidine were not reported. In conclusion, postoperative pain control with epidural clonidine was effective.
Kim, Se Hoon;Kim, Sang Min;Noh, Sang Ho;Kim, Jin Pyeong;Shin, Jae Hyuck;Sung, Si-Young;Jin, Jin Kwang;Kim, Taean
Journal of Powder Materials
/
v.22
no.3
/
pp.197-202
/
2015
In this study, porous stainless steel (STS316L) sintered body was fabricated by powder metallurgy method and its properties such as porosity, compressive yield strength, hardness, and permeability were evaluated. 67.5Fe-17Cr- 13Ni-2.5Mo (wt%) powder was produced by a water atomization. The atomized powder was classified into size with under $45{\mu}m$ and over $180{\mu}m$, and then they were compacted with various pressures and sintered at $1210^{\circ}C$ for 1 h in a vacuum atmosphere. The porosities of sintered bodies could be obtained in range of 20~53% by controlling the compaction pressure. Compressive yield strength and hardness were achieved up to 268 MPa and 94 Shore D, respectively. Air permeability was obtained up to $79l/min{\cdot}cm^2$. As a result, mechanical properties and air permeability of the optimized porous body having a porosity of 25~40% were very superior to that of Al alloy.
Kanagawa hemolysin (KH), an exotoxin produced from Kanagawa phenomenon-positive Vibrio parahemolyticus, has been shown to possess various biological activities including hemolysis, enterotoxicity, cytotoxicity, and cardiotoxicity. The aim of this study was to investigate the effect of KH on the cardiovascular system and its mechanism, employing in vivo and in vitro experiments of the rat. Intracerebroventricular (icv) administration of 100 mHU KH produced a marked and continuous pressor effect (icv KH-pressor effect), and the icv pressor effect was not repeatable. However, intravenous (iv) injection of the same dose of KH induced a prominent depressor effect (iv KH-depressor effect). The icv KH-pressor effect was inhibited by acid-denaturation, while the iv KH-depressor effect was not. Simultaneous icv administration of the three agents (ouabain, diltiazem, or bumetanide: $10{\mu}g/kg$ each) significantly reduced the pressor effect. The icv KH-pressor effect was inhibited by treatment with iv phentolamine or chlorisondamine, but was not affected by iv candesartan. The iv KH-depressor effect was repeatable and was attenuated by treatment with iv NAME or methylene blue. In vitro experiments using isolated thoracic aorta, $10^{-6}$ M phenylephrine (PE) and 50 mM KCl produced a sustained contraction. In rings contracted with either agents, KH showed relaxant responses in a concentration- dependent fashion and the relaxation (KH-vasorelaxation) was not dependent on the existence of the endothelium. The KH-vasorelaxation in the endothelium-intact rings contracted by PE was abolished by methylene blue treatment. In summary, the present findings suggest that in the icv KH-pressor effect the cation leak-inducing action of KH is implicated, which leads to the increased central sympathetic tone, that the iv KH-depressor effect results from the vasorelaxation via NO-guanylate cyclase system, and that the KH-vasorelaxation is independent of the endothelium and the guanylate cyclase system is involved in it. In conclusion, the mechanism of KH producing the icv pressor effect may not be identical to that of KH producing the iv depressor effect.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.