• Title/Summary/Keyword: prescriptive

Search Result 126, Processing Time 0.023 seconds

State of Practice of Performance-Based Seismic Design in Indonesia

  • Sukamta, Davy;Alexander, Nick
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.3
    • /
    • pp.211-220
    • /
    • 2012
  • The current 2002 Indonesian Seismic Code consists of prescriptive criteria that are intended to result in buildings capable of providing certain levels of performance. However, the actual performance capability of buildings is not assessed as part of the code procedures. Several analysis procedures are allowed, and the state of practice is to use the RSA with six-zone seismic map developed for 475-year earthquake. This code is being revised and will adopt many of the ASCE7-10 provisions and 2475-year earthquake for MCE. The growth of tall buildings compels engineers to look for more optimal lateral system. The use of RC core wall as single system has been adopted by very few engineering firms, which is allowed in the current code but will no longer be the case if the new one is in effect. Other innovative structural system such as core wall and outrigger is not addressed in the proposed new code. Engineers must then resort to NLRHA. Currently, one 50-story building under construction using RC core wall and outrigger has been designed with RSA and employing capacity design principles, then evaluated using NLRHA per TBI Guidelines. Based on the evaluation, the performance of the 50-story building generally still meets the criteria of the TBI Guidelines. The result of the case study is presented in this paper.

State of Practice of Performance-Based Seismic Design in Korea

  • Lee, Dong-Hun;Kim, Taejin;Kim, Jong-Ho;Kang, Dae-Eon
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.3
    • /
    • pp.195-201
    • /
    • 2012
  • Today, a great effort to develop PBSD procedure to be utilized in Korea is given by domestic structural engineers, academics, and governmental organizations. After Great East Japan Earthquake (2011) took place, lots of clients in Korea became to concern of their buildings so that requests of seismic performance evaluation and seismic rehabilitation for existing buildings have been gradually increased. Such interests in seismic events initiated a rapid development of a series of guidelines for seismic performance evaluation and seismic performance enhancement. For new buildings, however, design guidelines for PBSD are yet well prepared in Korea and prescriptive design methods are dominant design procedure still. Herein, seismicity demands used in seismic performance evaluation and some important design parameters in NLRH are introduced. Some project examples for seismic performance evaluation and rehabilitation applying passive energy dissipation devices are also described in the latter part of paper.

Performance Based Seismic Design - State of Practice 2012 in the United States of America

  • Klemencic, Ron;Fry, J. Andrew;Hooper, John;Baxter, Robert;Morgen, Brian;Solberg, Kevin;Zaleski, Krzysztof
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.3
    • /
    • pp.149-154
    • /
    • 2012
  • This paper presents a summary of the state of the practice for Performance Based Seismic Design (PBSD) in the United States. While it is not included in the prescriptive provisions of the United States' building codes, the PBSD procedure has been successfully implemented for two decades. The recent publication of the Guidelines for Performance-Based Seismic Design of Tall Buildings by the Pacific Earthquake Engineering Research Center (PEER) illustrates the fact that the engineering community has embraced this procedure and provides a thoughtful set of recommendations to building designers who intend to implement PBSD. The key parameters currently required for a PBSD also are outlined, such as seismic hazard definition, modeling procedures, and acceptance criteria. These Guidelines will serve as the basis for many PBSD projects in the coming years and as such are a common reference used throughout this paper. Finally, a brief summation of recent PBSD projects in the United States is presented.

Development of a Fully-Coupled, All States, All Hazards Level 2 PSA at Leibstadt Nuclear Power Plant

  • Zvoncek, Pavol;Nusbaumer, Olivier;Torri, Alfred
    • Nuclear Engineering and Technology
    • /
    • v.49 no.2
    • /
    • pp.426-433
    • /
    • 2017
  • This paper describes the development process, the innovative techniques used and insights gained from the latest integrated, full scope, multistate Level 2 PSA analysis conducted at the Leibstadt Nuclear Power Plant (KKL), Switzerland. KKL is a modern single-unit General Electric Boiling Water Reactor (BWR/6) with Mark III Containment, and a power output of $3600MW_{th}/1200MW_e$, the highest among the five operating reactors in Switzerland. A Level 2 Probabilistic Safety Assessment (PSA) analyses accident phenomena in nuclear power plants, identifies ways in which radioactive releases from plants can occur and estimates release pathways, magnitude and frequency. This paper attempts to give an overview of the advanced modeling techniques that have been developed and implemented for the recent KKL Level 2 PSA update, with the aim of systematizing the analysis and modeling processes, as well as complying with the relatively prescriptive Swiss requirements for PSA. The analysis provides significant insights into the absolute and relative importances of risk contributors and accident prevention and mitigation measures. Thanks to several newly developed techniques and an integrated approach, the KKL Level 2 PSA report exhibits a high degree of reviewability and maintainability, and transparently highlights the most important risk contributors to Large Early Release Frequency (LERF) with respect to initiating events, components, operator actions or seismic component failure probabilities (fragilities).

Application of Instruction Consulting to Improve the Elementary Preservice Teachers' Professionalism for Inquiry-based Classes (초등 예비 교사들의 탐구 수업 지도 전문성 향상을 위한 수업 컨설팅의 적용)

  • Park, Jae-Keun;Noh, Suk-Goo
    • Journal of Korean Elementary Science Education
    • /
    • v.30 no.2
    • /
    • pp.152-161
    • /
    • 2011
  • The purpose of this study is to diagnose difficulties and problems that the preservice teachers experience when teaching inquiry-based classes in elementary science and to improve their professionalism through prescriptive instruction consulting utilizing PDRE (preparation, diagnosis, reflective implementation, evaluation) model. The result of this study was as follows. First, preservice teachers considered themselves to be lack of scientific knowledge, but this study confirmed that the application of instruction consulting improved their understandings in scientific concepts and principles and corrected their misconceptions. Second, preservice teachers experienced difficulties in variables that might influence the results of experiments, cautions for the experiments and unexpected results of experiments, and this consulting allowed them to gain instruction ability to cope with such circumstances and solve problems effectively. Third, preservice teachers experienced difficulties in applying instructional model into their classes and preparing lesson plans, but consulting actually made limited but positive changes in their abilities. However, from a longer-term perspective, quantitative increase in their teaching opportunities, the development and distribution of example manuals, and the utilization of various class materials provided by the assistant centers for teaching and learning should be achieved side by side.

Trends of Nursing Science Inquiry in Doctoral Dissertations (박사학위논문에 나타난 간호학 탐구경향)

  • 김의숙;김광숙;김대란;김은정;성경미;신현숙;신혜경;이영자;정석희
    • Journal of Korean Academy of Nursing
    • /
    • v.34 no.2
    • /
    • pp.315-323
    • /
    • 2004
  • Purpose: The purpose of this study was to identify the theoretical characteristics and direction of inquiry in the discipline of nursing by analyzing doctoral dissertations. Method: The materials used in this study were 277 doctoral dissertations from five universities in Korea. The framework for the study was derived from Kim's(l993) alternative linkage among philosophy, theory, and method in nursing science. Result: Of the 277 dissertations it was found that there were 13 types of linkages out of a possible 54 types. Most of the dissertations (128 of 277) were done within the linkage of realism/etic/quantitative/explanatory knowledge type. Of the 218 dissertations within scientific realism, 42 were within relativism, and 17 within practicism. There were 134 dissertations of the explanatory knowledge type, 112 descriptive ones, and 31 prescriptive ones. Studies done within the etic quantitative methodology included 209 dissertations and within the emic perspective, 43 with qualitative methodology, and 7 with quantitative. Conclusion: The results show that it is necessary to develop more alternative linkages for nursing practice and this will lead to expanding nursing knowledge.

Evaluation of Limiting Temperatures of Rectangular Hollow Sections (각형 강관기둥부재의 한계온도 평가 연구)

  • Kwon, In-Kyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.331-332
    • /
    • 2012
  • Structural steel has been used as a primary materials to columns and beams since 1960's in Korea with an advantages of excellent of load-bearing capacity and design flexibility, and faster construction. However, if the steel columns made of structural steel exposed to fire the load-bearing capacity is going down steadily and finally reach to collapse. Therefore, building regulation requires fire resistance according to building occupation, scales. The fire resistance can be evaluated two categories. One is prescriptive method that is based on building regulation, specification and so on and the other is performance-based fire engineering method. The latter can be designed based on scientific and engineering consequences. The easiest evaluation way using the fire engineering design is comparing to the limiting temperature and maximum temperature calculated based on heat transfer theory. If the limiting temperature of a column exceeds the maximum temperature of it, the column can carry the load during the fire. Therefore, the database of limiting temperature is very essential for evaluation of column. In this paper, to build the database of column made of rectangular hollow sections 8 fire tests with loading were conducted and the relation between the limiting temperature and the applied loads showed in reverse proportion.

  • PDF

Fire Hazard Analysis and Performance Based Fire safety Design for the Clean Room in Semiconductor Factory (반도체공장 Clean Room에 대한 화재요인 분석 및 성능위주 화재안전설계)

  • Han, Su-Jin;Kang, Kyung-Sik
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2006.11a
    • /
    • pp.325-336
    • /
    • 2006
  • This research analyzes clean room major fire prevention standard of clean Room (FM, IRI, and NFPA Code), the structure of Performance-Based Fire Safety Design (PBD) applied the korean fire industry situation. Performance-Based Fire Safety can operate effectively the performance of fire protection equipment & building design, so the fitness of fire safety system can be embodied by operating this. moreover, cost to be consume fire safety of real building can reduce and Performance-Based Fire Safety is considered to important technique in fire protection field. A fire in a clean room may cause a serious loss by spreading smoke particles. We will be investigated by using a computational fluid dynamics, for loss prevention by smoke spreading from one fire area to another for clean room and compared the Performance-Based Fire Safety Design with the prescriptive code design. The methodology of fire safety performance-based fire safety design and guarantee of many kinds design skill of fire system and developing design procedure will be very serious one in order to improve efficiency of domestic system. Therefore, This research will be contributing to secure safety of clean room and to set up the performance-based fire safety design in Korea by regulation for the performance-based fire safety design effectively.

  • PDF

Fire Hazard Analysis and Performance Based Fire safety Design for the Clean Room in Semiconductor factory(1) (반도체공장 Clean Room에 대한 화재요인 분석 및 성능위주 화재안전설계(1))

  • Han, Su-Jin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.5
    • /
    • pp.211-229
    • /
    • 2006
  • This research analyzes clean room major fire prevention standard of clean Room(FM, IRI, and NFPA Code), the structure of Performance-Based Fire Safety Design(PBD) applied the korean fire industry situation. Performance-Based Fire Safety can operate effectively the performance of fire protection equipment & building design, so the fitness of fire safety system can be embodied by operating this. moreover, cost to be consume fire safety of real building can reduce and Performance-Based Fire Safety is considered to important technique in fire protection field. A fire in a clean room may cause a serious loss by spreading smoke particles. We will be investigated by using a computational fluid dynamics, for loss prevention by smoke spreading from one fire area to another for clean room and compared the Performance-Based Fire Safety Design with the prescriptive code design. The methodology of fire safety performance-based fire safety design and guarantee of many kinds design skill of fire system and developing design procedure will be very serious one in order to improve efficiency of domestic system. Therefore, This research will be contributing to secure safety of clean room and to set up the performance-based fire safety design in Korea by regulation for the performance-based fire safety design effectively.

Design and Construction Problems of Semi-Shield Method (SEMI-SHIELD 공법의 설계 및 시공상 문제점)

  • Kim, Jong-In;Jung, Sung-Nam;Park, Yeong-Geon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1275-1282
    • /
    • 2009
  • The tunnel excavations are used for construction of common utility tunnel, electric tunnel, communication line tunnel, water supply and public sewerage pile line in urban area. The trench cut methods were mainly used in the past, but now, tunneling method is more being used. The tunnel excavation method like as NATM, Messer-Shield, Semi-Shield Methods are being applied to small section tunnel in Korea. The actual construction results of seme-shield method are increasing due to simplified construction process and reduced noise and vibration. And also this method is being used frequently in waterway tunnel and construction of prevention flooding recently. The seme-shield method design guideline is absence except for electric line tunnel construction in Korea, because of the semi-shield method was developed in Europe and Japan. In the prescriptive design, engineer's subjects are tending to intervene, because of absence of standard and specification for details. Therefore, Design and Construction Problems of Semi-Shield Method were described and construction trouble was introduced for exam. These problem and construction troubles have to be examined thoroughly in advance.

  • PDF