• Title/Summary/Keyword: premolar

Search Result 985, Processing Time 0.031 seconds

A STUDY OF VON-MISES YIELD STRENGTH AFTER MANDIBULAR SAGITTAL SPLIT RAMUS OSTEOTOMY (하악지시상분할골절단술 시행 후 von-Miese 항복강도에 대한 유한요소법적 연구)

  • Yoon, Ok-Byung;Kim, Yeo-Gab
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.3
    • /
    • pp.196-204
    • /
    • 2002
  • For the study of its stability when the screw has been fixed after sagittal split ramus osteotomy(SSRO) of the mandible, the methods of screw arrangement are classified into two types, triangular and straight. The angles of screws to the bone surface are classified as perpendicular arrangements, the $60^{\circ}$ anterioinferior screw, known as triangular, and the most posterior screw, called straight arrangement, thus there are four types. The finite element method model has been made by using a three dimensional calculator and a supercomputer. The load directions are to the anterior teeth, premolar region, and molar region, and the bite force is 1 Kgf to each region. The distribution of stress, the von-Mises yield strength, and safety of margin refer to the total sum of transformed energy have been studied by comparison with each other. The following conclusion has been researched : 1. When shear stress is compared, in the triangular arrangement in the form of "ㄱ", the anterosuperior screw is seen at contributing to the support of the bone fragment. In the straight arrangement, substantial stress is seen to be concentrated on the most posterior angled screw. 2. When the von-Mises yield strength is compared, it seemed that the stress concentration on the angled anteroinferior screw is higher, it shows a higher possibility of fracture than any other screw. In the straight arrangement, stress appeared to be concentrated on the most posteriorly angled screw. 3. When the safety margins of the transfomed energy are compared, the energy conduction is much greater in the case of the angled screw than in the case of the perpendicular screw. The triangular arrangement in the form of "ㄱ" shows a superior clinical sign to that of the straight arrangement. Judging from the above results, when the screw fixation is made after SSRO in practical clinical cases, two screws should be inserted in the superior border of mandibular ramus and a third screw of mandibular inferior border should be inserted in the form of triangular. All screws on the bony surface should be placed perpendicularly-$90^{\circ}$ angles apparently best promote bony support and stability.

CLINICAL STUDY OF SURGICALLY ASSISTED RAPID MAXILLARY EXPANSION (외과적 술식을 동반한 급속 상악 확장술의 임상 연구)

  • Yang, Chan-Young;Min, Seung-Ki;Oh, Sung-Hwang;Kwon, Kyung-Hwan;Lee, Jun;Cha, Jae-Won
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.1
    • /
    • pp.60-69
    • /
    • 2005
  • Orthopedic rapid maxillary expansion(RME) has been a common treatment modality used to widen narrow maxillae in young children. However, since more skeletally matured adolescents or adults has closed midpalatal suture, the result of RME was undesirable because of dental tipping with little or no basal skeletal movement and resulted to many other complications. After such treatment, complications often occurred such as alveolar bending, compression of periodontal ligament, extrusion, buccal tipping, and severe relapse. Thus, surgically assisted rapid maxillary expansion(SA-RME) is required, especially for patients over 14 years old, to skeletally release maxillary expansion. We used two methods of maxillary expansion surgery. Surgically assisted rapid maxillary expansion(SA-RME) & surgically assisted posterior segmental expansion(SA-PSE) were used for narrow maxilla. The study was divided into two groups(SA-RME group and SA-PSE group). SA-RME group was consisted of 2 males and 4 females, and the ages of materials ranged from 15 years to 25 years with a mean of 20.2 years. SA-PSE group was consisted of 1 male and 5 females, and the ages ranged from 13 years to 23 years with a mean of 18.7 years. Dental study models were fabricated before starting the expansion and immediately after the expansion was completed. It was fabricated again 1 month later, 3 months later when the expansion device was removed, and 6 months later after the expansion was completed. A repeated measures analysis of variance(ANOVA) test was applied to assess changes between each groups over time. The amount of expansion and the amount of tipping movement each in both groups were compared by using paired t-test and it was also compared between each subjects within the group by using independent t-test. Both SA-RME and SA-PSE group showed stable results, but SA-PSE group showed statical significance in tipping movement of second premolar. We compared 6 patients who recieved SA-RME with 6 patients who received SA-PSE, and appraised the clinical usefulness.

CLINICAL AND RADIOGRAPHICAL EVALUATION OF IMPLANT-SUPPORTED FIXED PARTIAL PROSTHESES (임플랜트 지지 고정성 국소의치의 임상적, 방사선학적 평가)

  • Seo Ji-Young;Shim June-Sung;Lee Jae-Hoon;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.394-404
    • /
    • 2006
  • Statement of problem: A conventional 3-unit fixed partial denture design with a pontic between two retainers is the most commonly used. However in cases where the mental nerve is in close proximity to the second premolar, a cantilever design can be considered. As such, logical and scientific evidence is lacking for the number and position of implants to be placed for partially edentulous patients, and no clear-cut set of treatment principles currently exist. Purpose : The purpose of this study was to evaluate prognosis of implant-supported fixed partial dentures and to compare changes in bone level which may rise due to the different factors. Material and method : The present study examined radiographical marginal bone loss in patients treated with implant-supported fixed partial dentures (87 prostheses supported by 227 implants) and evaluated the influence of the span of the pontic, type of the opposing dentition. Clinical complications were studied using a retrospective method. Within the limitation of this study. the following result were drawn Result, 1. Seven of a total of 227 implants restored with fixed prostheses failed, resulting in a 96.9% success rate. 2. Complications encountered during recall appointments included dissolution of temporary luting agent (17 cases), porcelain fracture (8 cases), loosened screws (5 cases), gingival recession (4 cases), and gingival enlargement (1 case). 3. Marginal bone loss, 1 year after prosthesis placement, was significant(P<0.05) in the group that underwent bone grafting, however no difference in annual resorption rate was observed afterwards. 4. Marginal bono loss, 1 year post-placement, was greater in cantilever-type prostheses than in centric pontic protheses (P<0.05). 5. Marginal bone loss was more pronounced in posterior regions compared to anterior regions (P<0.05). 6. The degree of marginal bone loss was proportional to the length of the pontic (P<0.05). Conclusion: The success rate of implant-supported fixed partial dentures, including marginal bone loss, was satisfactory in the present study. Factors influencing marginal bone loss included whether bone graft was performed, location of the pontic (s), location of the surgical area in the arch pontic span. Long-term evaluation is necessary for implant-supported fixed partial dentures, as are further studies on the relationship between functional load and the number of implants to be placed.

A STUDY ON THE STABILITY OF 5 DIFFERENT SURFACE TREATMENT METHODS TO DENIAL IMPLANT USING RESONANCE FREQUENCY AND HISTOMORPHOMETRIC ANALYSIS (표면처리가 다른 5종 임플랜트의 안정성에 관한 연구)

  • Kim Sun-Jong;Shin Sang-Wan;Jung Sung-Min;Ryu Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.78-94
    • /
    • 2005
  • Purpose. The purpose of this study was to compare the effects of various surface treatments by measuring resonance frequency and histomorphometric analyses. Material and methods. In 5 adult dogs, the mandibular premolar were extracted. Six months later, 30 screw titanium implants (Dentium Co., Seoul, Korea) 6mm in length and 3.4mm in diameter, were placed in the mandibles of 5 dogs. Implants were divided into five groups following to surface treatment methods ; Group 1 is machined controls, Group 2 is sandblasted with large grit and acid-etched (SLA), Group 3 is anodized (Autoelectric Co., Korea, 660Hz, Duty10), Group 4 is hydroxyapatite(HA) coated by ion beam assisted deposition(E-beam), Group 5 is hydroxyapatite(HA) coated with Sol-gel coating process. Resonance frequency was measured implant placement immediately, and 3, 6 weeks and 10 weeks of healing perods. With the animal subject's sacrifice 10 weeks after implantation, implants were removed on bloc and histologic and computer-based histomorphometric analyses were performed. Histomorphometric analysis involved quantification of the entire bone to metal contact around the implants. Statistical analyses were performed using the SPSS for Windows (ver. 9.0 SPSS Inc.) Statistical differences were considered significant at P<0.05. Results. The results were as follows : 1) In five groups, mean value of resonance frequency analysis(RFA) were highest in group 5 (Sol-gel implant) at implantation and those of group 4 (E-beam)was highest at 10 weeks . but there was no correlation between surface treatments and RFA. 2) In all surface treatment groups, the RFA values of implants decreased until 3 weeks and increased to 10 weeks. 3) The percentage of direct bone-to-implant contact (BIC) had statistical significance between five groups in cancellous bone, (P<0.05) the percentage of bone density inside the thread had no statistical significance between five groups. (P>0.05) 4) There was a significant difference between cortical bone and cancellous bone in BIC. (P<0.05) and bone density. (P<0.05) 5) There was a correlation between the RFA value of implants at 10 weeks and BIC in cancellous bone, and between the RFA value of implants at 10 weeks and bone density in cortical bone. (P<0.05). Conclusions. These results indicate that surface treatment does not affect the implant stability in case of good bone quality.

The factors related with the failure in GBR and GTR technique (차폐막을 이용한 치주조직 및 골조직 유도재생술의 실패요인에 대한 고찰)

  • Yeom, Hey-Ri;Ku, Young;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.1
    • /
    • pp.117-128
    • /
    • 1997
  • Using barrier membrane, guided bone regeneration(GBR) and guided tissue regeneration(GTR) of periodontal tissue are now widely studied and good results were reported. In bone regeneration, not all cases gained good results and in some cases using GTR, bone were less regenerated than that of control. The purpose of this study is to search for the method to improve the success rate of GBR and GTR by examination of the cause of the failure. For these study, rats and beagle dogs were used. In rat study, 5mm diameter round hole was made on parietal bone of the rat and 10mm diameter of bioresorbable membrane was placed on the bone defects and sutured. In 1 ,2, 4 weeks later, the rats were sacrificed and Masson-Trichrome staining was done and inspected under light microscope for guided bone regeneration. In dog study, $3{\times}4mm^2$ Grade III furcation defect was made at the 3rd and 1th premolar on mandible of 6 beagle dogs. The defects were covered by bioresorbable membrane extending 2-3mm from the defect margin. The membrane was sutured and buccal flap was covered the defect perfectly. In 2, 4. 8 weeks later. the animals were sacrificed and undecalcified specimens were made and stained by multiple staining method. In rats. there was much amount of new bone formation at 2 weeks. and in 4 weeks specimen, bony defect was perfectly dosed and plenty amount of new bone marrow was developed. In some cases, there were failures of guided bone regeneration. In beagle dogs, guided tissue regeneration was incomplete when the defect was collapsed by the membrane itself and when the rate of resorption was so rapid than expected. The cause of the failure in GBR and GTR procedure is that 1) the membrane was not tightly seal the bony defects. If the sealing was not perfect, fibrous connective tissue infiltrate into the defect and inhibit the new bone formation and regeneration. 2) the membrane was too tightly attached to the tissue and then there was no space to be regenerated. In conclusion, the requirements of the membrane for periodontal tissue and bone regeneration are the biocompatibility, degree of sealingness, malleability. space making and manipulation. In this animal study. space making for new bone and periodontal ligament, and sealing the space might be the most important point for successful accomplishment of GBR and GTR.

  • PDF

A STUDY OF PRECISE FIT OF THE CAM ZIRCONIA ALL-CERAMIC FRAMEWORK (CAM Zirconia 완전도재 구조물의 정밀 적합도에 관한 연구)

  • Jeon Mi-Hyeon;Jeon Young-Chan;Jeong Chang-Mo;Lim Jang-Seop;Jeong Hee-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.5
    • /
    • pp.611-621
    • /
    • 2005
  • State of problem: Zirconia all-ceramic restoration fabricated with CAM system is on an increasing trend in dentistry. However, evaluation of the marginal and internal fits of zirconia bridge seldomly have been reported. Purpose: This study was to evaluate the at of margin and internal surface in posterior 3-unit zirconia bridge framework fabricated with CAM system(DeguDent, Germany). Material and Method: Preparations of secondary premolar and secondary molar on artificial resin model were performed for fabrication of 3-unit posterior bridge framework. Fits of 5 zirconia bridge framework were compared with 5 precious ceramo-metal alloy framework(V-GnathosPlus, Metalor, Switzerland), and prepared margins were designed to chamfer and shoulder finishing line. Each framework was cemented to epoxy resin model with reinforced glass ionomer(FujiCEM, GC Co., Japan), embedded in acrylic resin and sectioned in two planes, mesio-distal and buccolingual. Samples were divided into six pieces by sectioning and had two pieces of each surface(i.e mesial, distal, buccal and lingual surface) per abutment, so there were eight measuring points in each abutment. External gap was measured at the margin and internal gaps were measured at the margin, axial and occlusal surface. Gaps were observed under the measuring microscope(Compact measuring microscope STM5; Olympus, Japan) at a magnification of $\times100$. T-test were used to determine the statistic significance of the different gaps between zirconia and metal framework. Results and Conclusion: 1. External and internal marginal gaps of zirconia and metal framework were in clinically acceptable range. External marginal gaps were not different significantly between zirconia$(81.9{\mu}m)$ and metal $(81.3{\mu}m)$ framework and internal marginal gaps of zirconia $(44.6{\mu}m)$ were smaller than those of metal framework $(58.6{\mu}m)$. 2. Internal axial gaps of zirconia framework$(96.7{\mu}m)$ were larger than those of metal frame-work$(78.1{\mu}m)$ significantly and adversely, internal occlusal gaps of zirconia frame-work$(89.4{\mu}m)$ were smaller than those of metal framework $(104.9{\mu}m)$ significantly. 3. There were no significant differences in external and internal marginal gaps between chamfer and shoulder finish line when zirconia frameworks were fabricated.

STRESS DISTRIBUTION OF PERIODONTALLY INVOLVED TEETH RESTORED WITH VAR10US POSTS -THREE-DIMENSIONAL FINITE ELEMENT STUDY- (치주 지지가 감소된 소구치에서 포스트가 치근 응력 분포에 미치는 영향에 대한 3차원 유한요소법적 연구)

  • Jeong, Hye-Jin;Yoo, Jae-Heung;Oh, Nam-Sik;Kim, Han-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.567-578
    • /
    • 2007
  • Statement of problem: The endodontically treated tooth is generally restored with post and core, owing to the brittle and the loss of large amount of tooth structure. As periodontal treatment was developed, there are many cases that periodontally involved teeth used in prosthetic treatment. Purpose: The purpose of this study was to analyze the stress distribution in the dentin and post structures by the various post materials and the amount of remaining alveolar bone height. Material and method: The 3-dimensional finite element models of mandible 1st premolars were divided into six types according to the various amount of remaining alveolar bone and post type. All types were modeled using equal length, diameter and shape of the post. Three types of post and core materials were used: prefabricated titaniumpost and amalgam core, prefabricated stainless steel post and amalgam core, and cast gold post and core. 300 Newton force was applied to functional cusp of mandible 1st premolar. Results: The results were as follows: First, there was no apparent difference in the pattern of stress distribution according to the alveolar bone condition concentrate on the post middle area. Second, there was difference in pattern of stress distribution according to the core materials, gold post and core generated same than amalgam core. Third, there was no apparent difference in the pattern of stress distribution within the dentin according to the post and core materials. But a cast gold post and core generated the lowest maximum stress value, a stainless steel post generated the highest maximum stress value. Fourth, in the reduced alveolar bone model, maximum stress value is 1.5 times than that of the normal alveolar bone model. Conclusion: Within the limitations of this study, to provide minimal stress to the root with alveolar bone reduced, the post length may be as long as apical seal was not destroyed. To prevent fracture of tooth, it is rational to use gold alloy which material was good for stress distribution for post materials.

Fracture resistance of endodontically treated maxillary premolars restored by silorane-based composite with or without fiber or nano-ionomer

  • Shafiei, Fereshteh;Tavangar, Maryam Sadat;Ghahramani, Yasamin;Fattah, Zahra
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.3
    • /
    • pp.200-206
    • /
    • 2014
  • PURPOSE. This in vitro study investigated the fracture resistance of endodontically treated premolars restored using silorane-or methacrylate-based composite along with or without fiber or nano-ionomer base. MATERIALS AND METHODS. Ninety-six intact maxillary premolars were randomly divided into eight groups (n = 12). G1 (negative control) was the intact teeth. In Groups 2-8, root canal treatment with mesio-occlusodistal preparation was performed. G2 (positive control) was kept unrestored. The other groups were restored using composite resin as follows: G3, methacrylate-based composite (Z250); G4, methacrylate composite (Z250) with polyethylene fiber; G5 and G6, silorane-based composite (Filtek P90) without and with the fiber, respectively; G7 and G8, methacrylate-and silorane-based composite with nano-ionomer base, respectively. After aging period and thermocycling for 1000 cycles, fracture strength was tested and fracture patterns were inspected. The results were analyzed using ANOVA and Tukey HSD tests (${\alpha}$=0.05). RESULTS. Mean fracture resistance for the eight groups (in Newton) were G1: $1200{\pm}169^a$, G2: $360{\pm}93^b$, G3: $632{\pm}196^c$, G4: $692{\pm}195^c$, G5: $917{\pm}159^d$, G6: $1013{\pm}125^{ad}$, G7: $959{\pm}148^d$, G8: $947{\pm}105^d$ (different superscript letters revealed significant difference among groups). Most of the fractures in all the groups were restorable, except Group 3. CONCLUSION. Silorane-based composite revealed significantly higher strength of the restored premolars compared to that of methacrylate one. Fiber insertion demonstrated no additional effect on the strength of both composite restorations; however, it increased the prevalence of restorable fracture of methacrylate-based composite restored teeth. Using nano-ionomer base under methacrylate-based composite had a positive effect on fracture resistance and pattern. Only fiber-reinforced silorane composite restoration resulted in a strength similar to that of the intact teeth.

MESIODENS IN THE VAULT OF THE PALATE (상악 구개측 중앙부에 매복된 과잉치)

  • Min, Sung-Jin;Kim, Seong-Oh;Lee, Jae-Ho;Kwak, Ji-Youn;Choi, Byung-Jai;Choi, Hyung-Jun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.4
    • /
    • pp.670-674
    • /
    • 2005
  • Supernumerary tooth develops as a result of abnormal proliferation of the dental lamina during the initiation stage of dental development. It could be a sporadic occurrence or a hereditary transmission. Supernumerary tooth occurs with a frequency of 1 to 3%. Generally, there is a 2:1 preference for boys. It is usually found in the anterior portion of the maxilla and may be associated with complications such as impaction, malposition of permanent teeth, formation of diastema, cysts and eruption into nasal cavity, The position of supernumerary tooth found in the anterior portion of the maxilla is determined by the axis of the tooth. One third of supernumerary tooth in the anterior portion of the maxilla has no possibility of eruption due to its invertedly impacted position. However, as long as the coronal part of the follicle remains intact, migration of supernumerary tooth is possible. The migration may occur into the palate, the premolar region, the sinus or the nasal cavity. Also, growth of vertical dimension of maxilla could make surgical approach difficult as time goes by For this reason, we have found invertedly impacted mesiodens moved to the vault of the palate in the two cases, and extracted supernumerary tooth surgically.

  • PDF

DENTAL MANAGEMENT OF CEMENTO-OSSIFYING FIBROMA: A CASE REPORT (백악질 골화성 섬유종의 치과적 접근 : 증례보고)

  • Han, Ji-Hye;Baik, Byeong-Ju;Yang, Yeon-Mi;Lee, Sun-Young;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.2
    • /
    • pp.200-206
    • /
    • 2005
  • Cemento-ossifying fibroma of the jaws is well circumscribed, generally slow-growing, benign lesions which enlarge in an expansile manner. Clinically it presents as a slowly enlarging lesion commonly in the premolar-molar area of the mandible and only occasionally in the maxilla and other locations. It occurs twice as often in females and primarily in the 20 to 30 year age group. Differential diagnosis should be peformed, preferably with other fibro-osseous lesions such as fibrous dysplasia. A faster growing and more destructive variant of cemento-ossifying fibroma sometimes occurs in patients under age 15 and is termed juvenile (aggressive) ossifying fibroma. Treatment is surgical removal with the extent depending on the size and location of the individual lesion. Recurrence is considered rare. A case involving a 12-year-old male patient with delayed eruption of right mandibular canine is discussed. Following an incisional biopsy, the histopathologic diagnosis established was cemento-ossifying fibroma. After the surgical enucleation of the lesion, no sign of recurrence was detected.

  • PDF