• 제목/요약/키워드: premolar

검색결과 985건 처리시간 0.029초

치아매식술에 이용한 혈소판 유래 성장인자 함유 흡수성 차폐막의 골유도 재생효과 (Guided Bone Regeneration with a PDGF-BB-Ioaded Resorbable Membrane in the Dehisced Implant of the Beagle Dog)

  • 권영혁;박준봉;허익;정종평;한수부;이승진
    • Journal of Periodontal and Implant Science
    • /
    • 제28권3호
    • /
    • pp.431-451
    • /
    • 1998
  • 4 beagle dogs aged over one and half years and weighed 15 to 16 Kg were utilized in this study. Experimental dehiscent defects were made in the mandibular edentulous area after removal of lower premolar. e-PTFE membrane resorbable membrane, and PDGF-BB-loaded resorbable membrane were covered at the dehiscent defects around the dental implants respectively. Animal was sacrificed at 1, 2, 3 months respectively. Non-decalicifed specimens were made and mutiple-stained for light microscopic study. The results were as follows: 1. Dehiscent defects around the implant installed in the beagle dog were an excellent defect model for studying guided bone regeneration. 2. Fibroblasts penetrated into expanded-PTFE membrane was observed and inflammatory cell infiltration was also observed around the membrane. 3. Resorbable membrane was degradaded and resorbed at 1 month after application to the dehiscent defect. Though multinucleated giant cells were observed adjacent to the membrane, that had no reverse effect on the boe regeneration. 4. PDGF-BB-Ioaded resorbable membrane was same capability as the resorbable membrane and e-PTFE membrane in the guided bone regeneration. 5. PDGF-BB-Ioaded resorbable membrane-applied site was better than resorbable membrane-applied site in the speed and maturity of bone formation. Within the above results, it was suggested that PDGF-BB-Ioaded resorbable membrane might have same bone regeneration capacity as nonresorbable membrane in the dehisced implant of the beagle dog and potentiality to use in human subjects.

  • PDF

지각과민증에 대한 미세결정형 수산화인회석 함유 치약의 임상적 효과 (The effects of microcrystalline hydroxyapatite containing toothpaste in the control of tooth hypersensitivity)

  • 박정주;박준봉;권영혁;허익;정종혁
    • Journal of Periodontal and Implant Science
    • /
    • 제35권3호
    • /
    • pp.577-590
    • /
    • 2005
  • The purpose of this study was to evaluate the effects of toothpaste containing hydroxyapatite for patients who complained dental hypersensitivity. Before baseline of application of toothpaste with hydroxyapatite, tooth brushing instruction was done respectively and the several indices were measured at baseline, 2, 4, 8 weeks. Clinical indices were estimated, and responses to cold, compressive air, tactile stimulus were evaluated with verbal rating score. Relief effects and visual analogue scale were also evaluated. The results of this study were as follows 1. The occurrence rate of hypersensitivity in upper jaw was higher than that of lower jaws, and molar area showed more hypersensitivity than premolar and incisor area. Buccal site was hypersensitive followed by interproximal and lingual site. 2. Plaque index, gingival index and probing depth reduction were gradually improved after Tooth Brushing Instruction and using toothpaste. 3. Subjects showed most sensitive response to cold stimuli than compressive air and tactile stimuli. 4. The relief effect was increased during using tooth paste and complete relief was increased especially at 8 weeks. 5. Visual analogue scale was increased. In conclusion, it was confirmed that toothpaste containing microcrystalline hydroxyapatite have the relief effect of tooth hypersensitivity. During 8 weeks, stimulus responses were decreased and hypersensitivity relief effect was increased.

매식체 주위 열개형 골결손부에서 차단막과 골 이식술의 사용이 골 형성에 미치는 영향에 대한 임상 및 조직병리학적 연구 (Clinical and histopathological study on the effect of Nonresorbable membrane with Demineralized freeze dried bone graft for Guided Bone Regeneration in Implant Dehiscence Defects)

  • 권칠성;홍기석;임성빈;정진형;이종헌
    • Journal of Periodontal and Implant Science
    • /
    • 제35권3호
    • /
    • pp.687-702
    • /
    • 2005
  • The purpose of this study is to examine the effect of non-resorbable membrane such as e-PTFE which was used with DFDB in bone regeneration on dehiscence defect in peri-implant area. Amomg the patients, who have recieved an implant surgery at the department of Periodontics in Dan Kook University Dental Hospital, 12 patients showed implant exposure due to the dehiscence defect and 15 implants of these 22 patients were the target of the treatment. Periodontists randomly applied $Gore-Tex^{(R)}$ to the patients and treated them with antibiotics for five days both preoperatively and postoperatively. Reentry period was 26 weeks on average in maxilla and 14 weeks on average in mandible. The results were as follows : 1. Dehiscence bone defect frequently appeared in premolar in mandible and anterior teeth in maxilla respectively. 2. Among 15 cases, 1 membrane exposure was observed and in this case, regenerated area was decreased. 3. In non-resorbable membrane, bone surface area $9.25{\pm}4.84$ preoperatively and significantly increased to $11.48{\pm}7.52$ postoperatively(0.05). 4. The increase of bone surface area in non-resorbable membrane was $2.23{\pm}3.38$. 5. As a result of histopathological finding, DFDB surrounded by new bone formation and lamellate bone, resorption of DFDB and bone mineralization was found. Also, fibrosis of connective tissue beneath the membrane was found. This study shows that the surgical method using DFDB and non-resorbable membrane on dehiscence defect in peri-implant area is effective in bone regeneration.

Long-term cumulative survival and mechanical complications of single-tooth Ankylos Implants: focus on the abutment neck fractures

  • Shim, Hye Won;Yang, Byoung-Eun
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권6호
    • /
    • pp.423-430
    • /
    • 2015
  • PURPOSE. To evaluate the cumulative survival rate (CSR) and mechanical complications of single-tooth $Ankylos^{(R)}$ implants. MATERIALS AND METHODS. This was a retrospective clinical study that analyzed 450 single $Ankylos^{(R)}$ implants installed in 275 patients between December 2005 and December 2012. The main outcomes were survival results CSR and implant failure) and mechanical complications (screw loosening, fracture, and cumulative fracture rate [CFR]). The main outcomes were analyzed according to age, sex, implant length or diameter, bone graft, arch, and position. RESULTS. The 8-year CSR was 96.9%. Thirteen (2.9%) implants failed because of early osseointegration failure in 3, marginal bone loss in 6, and abutment fracture in 4. Screw loosening occurred in 10 implants (2.2%), and 10 abutment fractures occurred. All abutment fractures were located in the neck, and concurrent screw fractures were observed. The CSR and rate of screw loosening did not differ significantly according to factors. The CFR was higher in middle-aged patients (5.3% vs 0.0% in younger and older patients); for teeth in a molar position (5.8% vs 0.0% for premolar or 1.1% for anterior position); and for larger-diameter implants (4.5% for 4.5 mm and 6.7% for 5.5 mm diameter vs 0.5% for 3.5 mm diameter) (all P<.05). CONCLUSION. The $Ankylos^{(R)}$ implant is suitable for single-tooth restoration in Koreans. However, relatively frequent abutment fractures (2.2%) were observed and some fractures resulted in implant failures. Middle-aged patients, the molar position, and a large implant diameter were associated with a high incidence of abutment fracture.

Poly(alpha-hydroxy acids) 제제 생분해성 차폐막의 치주조직 재생유도능력에 관한 조직학적 장기관찰 (The long-term study on the guided tissue regeneration with poly(${\alpha}-hydroxy\;acid$} membranes in beagle dogs)

  • 류인철;구영;정종평;한수부;최상묵
    • Journal of Periodontal and Implant Science
    • /
    • 제27권3호
    • /
    • pp.633-645
    • /
    • 1997
  • The recent trend of research and development on guided tissue regeneration focuses on the biodegradable membranes, which eliminate the need for subsequent surgical removal. They have demonstrated significant and equivalent clinical improvements to the ePTFE membranes. This study evaluate guided tissue regeneration wound healing in surgically induced intrabony periodontal defects following surgical treatment with a synthetic biodegradable membranes, made from a copolymer of glycolide and lactide, in 8 beagle dogs. After full thickeness flap reflection, exposed buccal bone of maxillary and mandibular canine and premolar was removed surgically mesiodistally and occlusoapically at $6mm{\times}6mm$ in size for preparation of periodontal defects. In experimental sites a customized barrier was formed and fitted to cover the defect. Flap was replaced slightly coronal to CEJ and sutured. Plaque control program was initiated and maintained until completion of the study. In 4, 8, 16 and 24 weeks after surgery, the animals were sacrificed and then undecalcified specimens were prepared for histologic evaluation. Histologic examination indicated significant periodontal regeneration characterized by new connective tissue attachment, cementum formation and bone formation. These membranes showed good biocompatibility throughout experiodontal period. The barriers had been completely resorbed with no apparent adverse effect on periodontal wound healing at 24 weeks. These results implicated that present synthetic biodegradable membrane facilitated guided tissue regeneration in periodontal defect.

  • PDF

The effect of zirconia framework design on the failure of all-ceramic crown under static loading

  • Urapepon, Somchai;Taenguthai, Pakamard
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권2호
    • /
    • pp.146-150
    • /
    • 2015
  • PURPOSE. This in vitro study aimed to compare the failure load and failure characteristics of two different zirconia framework designs of premolar crowns when subjected to static loading. MATERIALS AND METHODS. Two types of zirconia frameworks, conventional 0.5 mm even thickness framework design (EV) and 0.8 mm cutback of full contour crown anatomy design (CB), were made for 10 samples each. The veneer porcelain was added on under polycarbonate shell crown made by vacuum of full contour crown to obtain the same total thickness of the experiment crowns. The crowns were cemented onto the Cobalt-Chromium die. The dies were tilted 45 degrees from the vertical plane to obtain the shear force to the cusp when loading. All crowns were loaded at the lingual incline of the buccal cusp until fracture using a universal testing machine with cross-head speed 0.5 mm/min. The load to fracture values (N) was recorded and statistically analyzed by independent sample t-test. RESULTS. The mean and standard deviations of the failure load were $1,170.1{\pm}90.9$ N for EV design and $1,450.4{\pm}175.7$ N for CB design. A significant difference in the compressive failure load was found (P<.05). For the failure characteristic, the EV design was found only cohesive failures within veneering porcelain, while the CB design found more failures through the zirconia framework (8 from 10 samples). CONCLUSION. There was a significant difference in the failure load between two designs, and the design of the framework influences failure characteristic of zirconia crown.

치면열구전색제 도포 후 광중합 할 때까지의 경과시간이 전색제 침투에 미치는 영향 (EFFECT OF TIME ELAPSED FROM APPLICATION TO CURING ON THE PENETRATION OF SEALANT)

  • 최선아;이창섭;이상호;이난영
    • 대한소아치과학회지
    • /
    • 제32권3호
    • /
    • pp.491-498
    • /
    • 2005
  • 치면열구전색제 도포 후 시간에 따른 열구 내 침투율을 알아보고자 발치된 소구치 192개를 이용하여 전색제 도포 후 광중합 할 때까지 경과시간 3초, 5초, 10초, 20초별로 침투율을 비교 분석하였다. 여기에 추가적으로 상악과 하악, filled sealant와 unfilled sealant군으로 나누어 시간대별로 침투율에 차이가 있는지도 비교분석하였다. 그 결과 시간이 경과할수록, filled sealant군보다 unfilled sealant군에서, 상악보다는 하악에서 전색제의 침투율이 증가하였다. 이상의 결과에서 임상에서 치면열구전색을 시행할 때 이 결과를 임상적 지침으로 적용하면 유용하리라고 여겨진다.

  • PDF

하악 제2소구치 결손과 연관된 치아 결손 및 발육지연 (Tooth Agenesis and Delay in Patients with Agenesis of Mandibular Second Premolars)

  • 박민지;김성오;송제선;이제호
    • 대한소아치과학회지
    • /
    • 제45권4호
    • /
    • pp.484-491
    • /
    • 2018
  • 선천적 치아의 결손은 비교적 흔한 치아 발육장애이며 하악 제2소구치의 결손은 치아 결손 중 가장 많이 나타나는 것으로 알려져 있다. 이 연구의 목적은 하악 제2소구치 결손과 연관되어 나타나는 다른 치아의 결손 및 치아의 발육 지연에 대해 조사하는 것이다. 이 연구는 2014년부터 2016년까지 연세대학교 치과대학을 내원하여 파노라마 방사선을 찍은 만 9세-15세의 소아청소년 중 하악 제2소구치 결손이 있는 환자를 대상으로 시행되었다. 하악 제2소구치의 결손을 가진 125명의 환자들 중 다른 치아의 결손은 58명(46.4%)에서 나타났으며 발육이 지연된 치아는 38명(30.4%)에서 나타났다. 이번 연구에서 하악 제2소구치의 결손을 가진 환자는 그렇지 않은 어린이와 비교하였을 때 치아 결손 및 치아 발육지연의 유병률이 높게 나타났다.

한국인 하악치아의 수평적인 위치관계에 관한 연구 (A Study on Horizontal Relationship of Mandibular Teeth in Korean Adults)

  • 최승민;최대균;최부병
    • 구강회복응용과학지
    • /
    • 제19권3호
    • /
    • pp.153-168
    • /
    • 2003
  • It is very important to arrange the artificial teeth correctly in bucco-lingual (labio- lingual) relation in reconstrcting dentition. Although many anatomic landmarks and techniques have been reported over the years, they are based on westerns. So this study was performd to examine the horizontal relations of mandibular teeth in Korean dentulous adults. 200 volunteers(mean age 22.9) who had natural dentition were selected. The impressions were taken with irreversible hydrocolloid impression material and mandibular study models were fabricated using class I dental stone. Then they were measured with 3-dimensional measuring device specially designed for this study. The results were as follows ; It is better to consider the lingual cusps of the lower posterior teeth as a guide than the linguoaxial surfaces of the lower posterior teeth, arranging the lower posterior teeth buccally to the line which starts from the mesial aspect of the lower canine and continue backward to the lingual aspect of the retromolar pad. It is better to arrange the fossae of the lower posterior teeth buccally to the line which starts from the cusp tip of the lower canine and continue backward to the top of the retromolar pad. The positions of the lower posterior teeth in the denture-bearing area ; considering the fossa as a guide, the 2nd premolar was positioned in center. considering the buccal cusp as a guide, the 1st molar and the 2nd molar were positioned in center. the distance ratio(d/a) was incresed constantly from the lower canine to the 2nd molar d ; the distance between the buccal vestibule(the lowest point) and the buccal cusp tips of the lower posterior teeth. a ; the distance between the buccal vestibule(the lowest point) and the lingual vestibule(the lowest point). The lower canine was positioned lingually($0.11{\pm}0.13$) than the labial vestibule, and the central incisor and the lateral incisor were positioned almost in the imaginary perpendicular plane of the labial vestibule(the lowest point).

내부연결방식 임플랜트 시스템의 삼차원 유한요소법적 연구 (THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF INTERNALLY CONNECTED IMPLANT SYSTEMS)

  • 김유리;조혜원;이재봉
    • 대한치과보철학회지
    • /
    • 제44권1호
    • /
    • pp.85-102
    • /
    • 2006
  • Statement of problem: Currently, there are some 20 different geometric variations in implant/abutment interface available. The geometry is important because it is one of the primary determinants of joint strength, joint stability, locational and rotational stability. Purpose: As the effects of the various implant-abutment connections and the prosthesis height variation on stress distribution are not yet examined this study is to focus on the different types of implant-abutment connection and the prosthesis height using three dimensional finite element analysis. Material and method. The models were constructed with ITI, 3i TG, Bicon, Frialit-2 fixtures and solid abutment, TG post, Bicon post, EstheticBase abutment respectively. And the super structures were constructed as mandibular second premolar shapes with 8.5 mm, 11 mm, 13.5 mm of crown height. In each model, 244 N of vertical load and 244 N of $30^{\circ}$ oblique load were placed on the central pit of an occlusal surface. von Mises stresses were recorded and compared in the crowns, abutments, fixtures. Results: 1. Under the oblique loading, von Mises stresses were larger in the crown, abutment, fixture compared to the vertical loading condition. 2. The stresses were increased proportionally to the crown height under oblique loading but showed little differences with three different crown heights under vertical loading. 3. In the crown, the highest stress areas were loading points under vertical loading, and the finish lines under oblique loading. 4. Under the oblique loading, the higher stresses were located in the fixture/abutment interface of the Bicon and Frialit-2 systems compared to the ITI and TG systems. Conclusions: The stress distribution patterns of each implant-abutment system had difference among them and adequate crown height/implant ratio was important to reduce the stresses around the implants.