• 제목/요약/키워드: premolar

검색결과 984건 처리시간 0.028초

Comparative evaluation of molar distalization therapy using pendulum and distal screw appliances

  • Caprioglio, Alberto;Cafagna, Alessandra;Fontana, Mattia;Cozzani, Mauro
    • 대한치과교정학회지
    • /
    • 제45권4호
    • /
    • pp.171-179
    • /
    • 2015
  • Objective: To compare dentoalveolar and skeletal changes produced by the pendulum appliance (PA) and the distal screw appliance (DS) in Class II patients. Methods: Forty-three patients (19 men, 24 women) with Class II malocclusion were retrospectively selected for the study. Twenty-four patients (mean age, $12.2{\pm}1.5years$) were treated with the PA, and 19 patients (mean age, $11.3{\pm}1.9years$) were treated with the DS. The mean distalization time was 7 months for the PA group and 9 months for the DS group. Lateral cephalograms were obtained at T1, before treatment, and at T2, the end of distalization. A Mann-Whitney U test was used for statistical comparisons of the two groups between T1 and T2. Results: PA and DS were equally effective in distalizing maxillary molars (4.7 mm and 4.2 mm, respectively) between T1 and T2; however, the maxillary first molars showed less distal tipping in the DS group than in the PA group ($3.2^{\circ}$ vs. $9.0^{\circ}$, respectively). Moreover, significant premolar anchorage loss (2.7 mm) and incisor proclination ($5.0^{\circ}$) were noted in the PA group, whereas premolar distal movement (1.9 mm) and no significant changes at the incisor ($0.1^{\circ}$) were observed in the DS group. No significant sagittal or vertical skeletal changes were detected between the two groups during the distalization phase. Conclusions: PA and DS seem to be equally effective in distalizing maxillary molars; however, greater distal molar tipping and premolar anchorage loss can be expected using PA.

3-dimensional reconstruction of mandibular canal at the interforaminal region using micro-computed tomography in Korean

  • Jeon, Yong Hyun;Lee, Chul Kwon;Kim, Hee-Jung;Chung, Jae-Heon;Kim, Heung-Joong;Yu, Sun-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권6호
    • /
    • pp.470-475
    • /
    • 2017
  • PURPOSE. The purpose of this study was to identify the complex course of the mandibular canal using 3D reconstruction of microCT images and to provide the diagram for clinicians to help them understand at the interforaminal region in Korean. MATERIALS AND METHODS. Twenty-six hemimandibles obtained from cadavers were examined using microCT, and the images were reconstructed. At both the midpoint of mental foramen and the tip of anterior loop, the bucco-lingual position, the height from the mandibular inferior border, the horizontal distance between two points, and position relative to tooth site on the mandibular canal were measured. The angle that the mental canal diverges from the mandibular canal was measured in posterior-superior and lateral-superior direction. RESULTS. The buccal distance from the mandibular canal was significantly much shorter than lingual distance at both the mental foramen and the tip of anterior loop. The mandibular canal at the tip of anterior loop was significantly located closer to buccal side and higher than at the mental foramen. And the mental canal most commonly diverged from the mandibular canal below the first premolar by approximately $50^{\circ}$ posterior-superior and $41^{\circ}$ lateral-superior direction, which had with a mean length of 5.19 mm in front of the mental foramen, and exited to the mental foramen below the second premolar. CONCLUSION. These results suggest that it could form a hazardous tetrahedron space at the interforaminal region, thus, the clinician need to pay attention to the width of a premolar tooth from the mental foramen during dental implant placement.

Gap comparison between single crown and three-unit bridge zirconia substructures

  • Anunmana, Chuchai;Charoenchitt, Masnisa;Asvanund, Chanavut
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권4호
    • /
    • pp.253-258
    • /
    • 2014
  • PURPOSE. To compare marginal and internal gaps of zirconia substructure of single crowns with those of three-unit fixed dental prostheses. MATERIALS AND METHODS. Standardized Co-Cr alloy simulated second premolar and second molar abutments were fabricated and subsequently duplicated into type-III dental stone for working casts. After that, all zirconia substructures were made using $Lava^{TM}$ system. Marginal and internal gaps were measured in 2 planes (mesial-distal plane and buccal-palatal plane) at 5 locations: marginal opening (MO), chamfer area (CA), axial wall (AW), cusp tip (CT) and mid-occlusal (OA) using Replica technique. RESULTS. There were significant differences between gaps at all locations. The $mean{\pm}SD$ of marginal gap in premolar was $43.6{\pm}0.4{\mu}m$ and $46.5{\pm}0.5{\mu}m$ for single crown and 3-unit bridge substructure respectively. For molar substructure the $mean{\pm}SD$ of marginal gap was $48.5{\pm}0.4{\mu}m$ and $52.6{\pm}0.4{\mu}m$ for single crown and 3-unit bridge respectively. The largest gaps were found at the occlusal area, which was $150.5{\pm}0.5{\mu}m$ and $154.5{\pm}0.4{\mu}m$ for single and 3-unit bridge premolar substructures respectively and $146.5{\pm}0.4{\mu}m$ and $211.5{\pm}0.4{\mu}m$ for single and 3-unit bridge molar substructure respectively. CONCLUSION. Independent-samples t-test showed significant differences of gap in zirconia substructure between single crowns and three-unit bridge (P<.001). Therefore, the span length has the effect on the fit of zirconia substructure that is fabricated using CAD/CAM technique especially at the occlusal area.

상악 소구치 과잉치와 하악 절치 과잉치에 대한 치험례 (CASE REPORT: SUPERNUMERARY TEETH ON MAXILLARY PREMOLAR AND MANDIBULAR INCISAL AREA)

  • 오민형;김대업;라지영;이광희
    • 대한소아치과학회지
    • /
    • 제33권3호
    • /
    • pp.529-533
    • /
    • 2006
  • 과잉치란 정상적인 치식과 비교했을 때 정상에 비하여 많은 수의 치아를 일컫는 것으로 유치열에 비하여 영구치열에서 더 흔하게 나타난다. 과잉치는 상악과 하악 모두에서 발생이 되지만 주로 상악에서 발생한다. 상악에서도 90% 가량이 상악의 전방부에서 발생하며, 일반적으로 알려진 과잉치의 발생 부위에 따른 빈도는 상악 중절치 및 상악 정중부, 상악 측절치, 하악 소구치, 상악 소구치, 상악 견치, 하악 견치, 하악 중절치의 순서를 따른다. 본 증례보고에서는 상악 소구치 과잉치와 하악 절치 과잉치의 흔치 않은 두 증례에 대해 보고한다. 첫 번째 증례에서는 하악 우측 측절치와 하악 우측 제1소구치 사이에 위치한 과잉치로 인하여 하악 우측 견치의 순측 맹출 양상 및 총생의 양상을 보였으며 두 번째 증례에서는 상악 좌측 제 1소구치와 제2소구치 사이에 위치한 과잉치로 인하여 상악 좌측 제2유구치의 치근 흡수와 제2소구치 치배의 비정상적인 위치를 보였다. 두 증례 모두 해당 과잉치의 발거를 시행하였으며 양호한 치료 결과를 얻었기에 보고하는 바이다.

  • PDF

Posterior dental compensation and occlusal function in adults with different sagittal skeletal malocclusions

  • Hwang, Soonshin;Choi, Yoon Jeong;Jung, Sooin;Kim, Sujin;Chung, Chooryung J.;Kim, Kyung-Ho
    • 대한치과교정학회지
    • /
    • 제50권2호
    • /
    • pp.98-107
    • /
    • 2020
  • Objective: The aim of this study was to compare posterior tooth inclinations, occlusal force, and contact area of adults with different sagittal malocclusions. Methods: Transverse skeletal parameters and posterior tooth inclinations were evaluated using cone beam computed tomography images, and occlusal force as well as contact area were assessed using pressure-sensitive films in 124 normodivergent adults. A linear mixed model was used to cluster posterior teeth into maxillary premolar, maxillary molar, mandibular premolar, and mandibular molar groups. Differences among Class I, II, and III groups were compared using an analysis of variance test and least significant difference post-hoc test. Correlations of posterior dental inclinations to occlusal function were analyzed using Pearson's correlation analysis. Results: In male subjects, maxillary premolars and molars had the smallest inclinations in the Class II group while maxillary molars had the greatest inclinations in the Class III group. In female subjects, maxillary molars had the smallest inclinations in the Class II group, while maxillary premolars and molars had the greatest inclinations in the Class III group. Occlusal force and contact area were not significantly different among Class I, II, and III groups. Conclusions: Premolar and molar inclinations showed compensatory inclinations to overcome anteroposterior skeletal discrepancy in the Class II and III groups; however, their occlusal force and contact area were similar to those of Class I group. In subjects with normodivergent facial patterns, although posterior tooth inclinations may vary, difference in occlusal function may be clinically insignificant in adults with Class I, II, and III malocclusions.

하악골 골염도의 정량적 평가에 관한 비교연구 (A Comparative Study of Quantitative Assessment of Bone Mineral Density of the Mandible)

  • 박원길;최의환;김재덕
    • 치과방사선
    • /
    • 제29권1호
    • /
    • pp.161-173
    • /
    • 1999
  • This study was performed to compare the bone mineral densities measured at mandibular premolar area by copper-equivalent image and hydroxyapatite phantom with those measured at radius by dual energy absorptiometry and to evaluate the clinical usefulness of Digital system with slide scanner, copper-equivalent image, and hydroxyapatite phantom. For experiment. intraoral radiograms of 15 normal subjects ranged from 20 years old to 67 old were taken with copper-step wedge at mandibular premolar area and bone mineral densities calculated by conversion equation to bone mineral density of hydroxyapatite were compared with those measured at radius distal 1/3 area by Hologic QDR-1000. Obtained results as follows: 1) The conversion equation was Y=5.97X-0.25 and its determination coefficient was 0.9967. The coefficient of variation in the measurement of copper-equivalent value ranged from 4% to 8% and showed high reproducibility. 2) The coefficient of variation in the measurement of bone mineral density by the equation ranged from 7% to 8% and showed high reproducibility. 3) The bone mineral densities ranged from 0.35 to 0.79g/cm2 at mandibular premolararea. 4) The correlation coefficient between bone mineral densities at mandibular premolar area and those at radius distal 1/3 area was 0.8965. As summary, digital image analyzing system using copper-equivalent image and hydroxyapatite phantom appeared to be clinically useful to measure the bone mineral density at dental area.

  • PDF

치과용 콘빔전산화단층영상에서 치조골과 치아의 협설경사 비교 (Comparison of the buccolingual inclination in alveolar bone and tooth using dental CBCT)

  • 김성은;김진수;김재덕
    • Imaging Science in Dentistry
    • /
    • 제38권1호
    • /
    • pp.17-22
    • /
    • 2008
  • Purpose: It is important to determine the bucco-lingual inclination of implants on radiographs before the implant surgery. The purpose of this study was to compare the buccolingual inclination in alveolar bone and the tooth with dental cone beam CT and to prepare the standard for the buccolingual inclination of implant. Materials and Methods: Axial, panoramic, and buccolingually sectioned images of 80 implant cases with stent including straight marker using CB $Mercuray^{TM}$ (Hitachi, Japan) were evaluated. The comparison of the buccolingual inclination of remained alveolar bone with the tooth and the marker on butcolingually sectioned views was performed statistically. Results: The average buccolingual inclination of remained alveolar bone and tooth was $82.8{\pm}4.6^{\circ}\;and\;85.8{\pm}4.7^{\circ}$ (p<0.05, r=0.96) at the 1st molar area and $76.4{\pm}1.7^{\circ}\;and\;82.7{\pm}1.7^{\circ}$ respectively (p>0.05, r=0.12) at the 2nd premolar area in upper jaw. The average buccolingua1 inclination of remained alveolar bone and tooth was $81.3{\pm}8.3^{\circ}\;and\;87.5{\pm}6.3^{\circ}$ (p>0.05, r=0.85) at the lower 2nd premolar area and $94.3{\pm}6.6^{\circ}\;and\;93.3{\pm}7.2^{\circ}$ respectively (p>0.05, r=0.91) at the 1st molar area in lower jaw. The inclinations of markers were very different from those of remained bone at the most of areas except the upper 2nd premolar area (r=0.79). Conclusion: We recommend dental CBCT analysis for determining the buccolingual inclination of dental implant, because of significant difference, in average, between the bucco1ingual inclination of remained alveolar bone and tooth.

  • PDF

성견 치조골 결손부에 자가골이식과 조직유도재생막을 이용한 치주치료시 치유효과에 관한 비교연구 (COMPARATIVE STUDY OF AUTOGENOUS BONE GRAFT AND GUIDED TISSUE REGENERATION IN THE TREATMENT OF PERIODONTAL DEFECT IN DOGS)

  • 홍기석;김종여;정진형
    • Journal of Periodontal and Implant Science
    • /
    • 제24권1호
    • /
    • pp.205-216
    • /
    • 1994
  • The goal of periodontal therapy is the regeneration of the periodontium lost by periodontal disease. The purpose of this study was to evaluate the regenerative potential of the autogenous bone graft and guided tissue regeneration in the treatment of periodontal bony defect in dogs. Experimental periodontitis were induced in the mandibular left 3rd premolar and right 3rd and 4th premolars of 5 dogs using orthodontic ligature wire. After 6 weeks, the ligature wire removed, surgical procedure were performed as follows. 1) control group : Flap operation(Mn.Lt 3rd premolar) 2) experimental group I : Flap operation + autogenous bone graft (Mn.Rt. 3rd premolar) 3) experimental group II : Flap operation + Gore-Tex membrane (Mn.Rt. 4th premoalr) Thereafter, dogs were sacrificed on the 1,2,4,8,16th week and the specimens were prepared and stained with hematoxyline-eosin stain for the light microscopic examination. The results of this study were as follows. 1. The apical migration of junctional epithelium was most remarkable in the flap operation and the experimental group II was less than the experimental group I. 2. In the formation of new alveolar bone, it was found in experimental group I,II and experimental group I is more than II. In the control group, few bone formation was found. 3. In the formation of new cementum, it was found in experimental group I,II and experimental group II is more than I. So, the periodontal therapy combined with autogenous and guided tissue regeneration will be produce the periodontal regeneration.

  • PDF

성견 열개형 수평 결손부에서 Calcium Sulfate 차단막이 치주조직 치유에 미치는 영향 (The Effects of Calcium sulfate Membrane on the Periodontal Wound Repair of Horizontal Dehiscence defects in Dogs)

  • 최성호;조규성;문익상;채중규;김종관
    • Journal of Periodontal and Implant Science
    • /
    • 제27권1호
    • /
    • pp.249-262
    • /
    • 1997
  • The present study investigates the effects of calcium sulfate graft on the periodontal healing in intrabony periodontal defects of dogs. Following the general anesthesia with 30mg/kg pentobarbital injected intravenously, the first premolar was extracted and full-thickness periodontal flap was elevated from the second premolar to the fourth premolar. The portion of premolars coronal to the alveolar crest was removed and mesial and distal roots were separated. Exposed root canals were sealed with Caviton and covered completely with flaps sutured. Following the healing period of 12 weeks, the surgical sited were uncovered and $4{\times}4mm$ intrabony defects were surgically created. Those defects with calcium sulfate graft following the root planing was designated as the test sites and those with flap surgery-only were designated as control sites. The animals were sacrificed after 8 weeks and the healing was histologically analyzed. The results were as follows. 1. No foreign body reaction or inflammation were observed in either groups. Calcium sulfate was completely resorbed in the test sites. 2. New cementum was observed coronal to the notch in both groups. Connective tissue fibers were oriented parallel to the root surface in the controls. Connective tissues were formed in large amount in the sites. 3. Test sites showed marked amount of new bone formation while the control sites showed minimal bone gain. 4. Root resorption was observed in coronal portions of th control Sites. The results suggest that calcium sulfate is a biocompatible graft material with a potential for new bone and cementum formation.

  • PDF

Accuracy of 3D white light scanning of abutment teeth impressions: evaluation of trueness and precision

  • Jeon, Jin-Hun;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권6호
    • /
    • pp.468-473
    • /
    • 2014
  • PURPOSE. This study aimed to evaluate the accuracy of digitizing dental impressions of abutment teeth using a white light scanner and to compare the findings among teeth types. MATERIALS AND METHODS. To assess precision, impressions of the canine, premolar, and molar prepared to receive all-ceramic crowns were repeatedly scanned to obtain five sets of 3-D data (STL files). Point clouds were compared and error sizes were measured (n=10 per type). Next, to evaluate trueness, impressions of teeth were rotated by $10^{\circ}-20^{\circ}$ and scanned. The obtained data were compared with the first set of data for precision assessment, and the error sizes were measured (n=5 per type). The Kruskal-Wallis test was performed to evaluate precision and trueness among three teeth types, and post-hoc comparisons were performed using the Mann-Whitney U test with Bonferroni correction (${\alpha}=.05$). RESULTS. Precision discrepancies for the canine, premolar, and molar were $3.7{\mu}m$, $3.2{\mu}m$, and $7.3{\mu}m$, respectively, indicating the poorest precision for the molar (P<.001). Trueness discrepancies for teeth types were $6.2{\mu}m$, $11.2{\mu}m$, and $21.8{\mu}m$, respectively, indicating the poorest trueness for the molar (P=.007). CONCLUSION. In respect to accuracy the molar showed the largest discrepancies compared with the canine and premolar. Digitizing of dental impressions of abutment teeth using a white light scanner was assessed to be a highly accurate method and provided discrepancy values in a clinically acceptable range. Further study is needed to improve digitizing performance of white light scanning in axial wall.