• Title/Summary/Keyword: prefabricated system

Search Result 138, Processing Time 0.047 seconds

All-on-4 implant restoration with full-digital system preserving existing occlusion: A case report (완전 디지털 시스템으로 기존 교합을 보전한 All-on-4 임플란트 수복증례)

  • Kim, Kyoung Hee;Jeong, Seung-Mi;Lee, Ye Chan;An, Xue Yin;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.330-337
    • /
    • 2018
  • In edentulous patients, implant - supported fixed prosthesis treatment has been proved to be useful, but involves complex treatment process. On the other hand, in the modern dentistry, digital technology has been developed day by day and it has expanded its range to the implant restoration of edentulous patients. In this case, a digital system was used for all stages of diagnosis, surgery, design and fabrication of provisional implants fixed prosthesis restoration in 66-year-old mandibular edentulous patients. In the preoperative diagnosis stage, a provisional restoration was designed based on the mucosal scan using the intraoral scanner and the stable occlusion of prefabricated complete denture of the patient. After flapless implant surgery using the surgical guide, the prefabricated interim restoration was connected to the implant and used as immediate provisional restoration. The final restoration was designed and fabricated by transferring the vertical dimension and the centric relation of the provisional restoration with stable occlusion using digital technology. We report a simple protocol of implant treatment in edentulous patients by using digital techniques to preserve the patient's vertical dimension and occlusion.

The effects and follow-up of early preorthdontic trainer treatment on class II malocclusions (2급 부정교합에서 교정 전 Trainer를 이용한 조기치료 효과와 예후관찰)

  • Shim, Youn-Soo;Kim, Ah-Hyeon;An, So-Youn
    • Journal of Digital Convergence
    • /
    • v.11 no.4
    • /
    • pp.303-309
    • /
    • 2013
  • TRAINER for Kids ($T4K^{TM}$, Myofunctional. Research Co, Australia) is a prefabricated myofunctional orthodontic appliance recommended to ClassII division1 malocclusion patients who have bad oral habits such as mouth breathing, tongue thrusting, inappropriate tongue position, thumb sucking and so on. Trainer has a soft texture and a small volume so that those advantages lead to an increase in the agreement rate of young patients of its use. This presentation is to analyze clinical efficacy of Trainer. The analysis is based on a result of regular follow-up on Class II division1 malocclusion patients who has been completely treated by Trainer in the Sanbon Dental Hospital of Wonkwang university. This case report is to present the satisfactory results gained by using Trainer on Class II patients. First, Trainer was applied in Class II malocclusion patients of mixed dentition with expected space insufficient to gain facial improvement. Second, excessive overjet, overbite were improved. Third, main effects are regarded to have been achieved by development of lingual slant of upper jaw, labial slant of lower jaw, and lower part of jaw bone.

Geotechnical Characteristics of Prefabricated Vertical Drain System for Contaminated Soil Remediation (오염토양 복원을 위한 연직배수시스템의 지반공학적 특성)

  • Shin, Eunchul;Park, Jeongjun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.5
    • /
    • pp.5-14
    • /
    • 2007
  • The quantity of noxious wastes generated by the growth in industrialization and population in all over the world and its potential hazards in subsurface environments are becoming increasingly significant. The extraction of the contaminant from the soil and movement of the water are restricted due to the low permeability and adsorption characteristics of the reclaimed soils. Incorporated technique with PVDs have been used for dewatering from fine-grained soils for the purpose of ground improvement by means of soil flushing and soil vapor extraction systems. This paper is to evaluate several key parameters that affected to the performance of the PVDs specifically with regard to: well resistance of PVD, zone of influence, and smear effects. In the feasibility of contaminant remediation was evaluated in pilot-scale laboratory experiments. Well resistance is affected on the vertical discharge capacity of the PVDs under the various vacuum pressures. The discharge capacity increases consistently in areal extents with higher applied vacuum up to a limiting vacuum pressure. The head values for each piezometer at different vacuum pressures show that the largest head loss occurs within 14 cm of the PVD. Air flow rates and head losses were measured for the PVD placed in the model test box and the gas permeability of the silty soils was calculated. Increasing the equivalent diameter results in a decrease in the calculated gas permeability. It is concluded that the gas permeability determined over the 1,500 to 2,000 $cm^3/s$ flow rates are the most accurate values which yields gas permeability of about 3.152 Darcy.

  • PDF

Experimental Study on the Load Transfer Behavior of Steel Grid Composite Deck Joint (격자형 강합성 바닥판 이음부의 하중전달 거동에 관한 실험적 연구)

  • Shin, Hyun-Seop
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.10-21
    • /
    • 2014
  • The joint of prefabricated steel grid composite deck is composed of concrete shear key and high-tension bolts. The flexural and shear strength of the joint were experimentally evaluated only by the bending and push-out test of the joint element. In this study the lateral load transfer behavior of the joint in deck structure system is experimentally evaluated. Several decks connected by the joint are prefabricated and loaded centrically and eccentrically. In the case of centrically loaded specimens, the analysis results show that for the same loading step the rotation angle of the joint with 4 high-tension bolts is larger than the case of the joint with 9 high-tension bolts. Consequently, flexural stiffness of deck and lateral load transfer decrease in the case of specimen with 4 high-tension bolts. But, in the case of eccentrically loaded specimens, it is found that there are no significant differences in the load transfer behavior. The further analysis results about the structural behavior of the joint show that lateral load transfer can be restricted by the load bearing capacity of the joint as well as punching shear strength of the slab. Furthermore, considering that high-tension bolts in the joint didn't reach to the yielding condition until the punching shear failure, increase in the number of high-tension bolts from 4 to 9 has a greater effect on the flexural stiffness of the joint and deck system than the strength of them.

A Study on the Characteristics of RTA Furniture and Development of Seminar Table (RTA가구의 특성과 세미나 테이블 개발에 관한 연구)

  • Lee, Nak Hyun;Kim, Mi Sook
    • Journal of the Korea Furniture Society
    • /
    • v.28 no.4
    • /
    • pp.259-267
    • /
    • 2017
  • Furniture should change according to space. Therefore, it is important that the flexibility of the furniture, the functional efficiency, the economical efficiency and the convenience of the furniture of today. These characteristics are also important for seminar tables that are used temporarily by a large number of people. The seminar furniture currently in use has no shielding plate, there are two forms of table and shielding plate folding table. Therefore, in this research, furniture design and product development that can complement the shortcomings of the seminar furniture currently in use were done. Analysis of problems through overseas investigation and domestic market research, design planning and design, and prototyping. We have sought to optimize the volume by applying the characteristics of RTA furniture to develop a lightweight, lightweight, lightweight, easy to install and easy to use shielding plate, and open and closed system. Basically developed two types of shielding board seminar table basic shape and Roll Screen type, we expanded the scope of application such as each color and pattern. In order to reduce the weight, we replaced the parts such as anchor bolts and hinges and the shielding plate with Roll Screen and pursued volume optimization. As a result of this research, it is expected that the system of mechanisms such as packaging standardization and damage prevention for weight reduction and volume optimization will contribute to building competitiveness by domestic office prefabricated furniture industry's original technology.

Field instrumentation and settlement prediction of ground treated with straight-line vacuum preloading

  • Lei, Huayang;Feng, Shuangxi;Wang, Lei;Jin, Yawei
    • Geomechanics and Engineering
    • /
    • v.19 no.5
    • /
    • pp.447-462
    • /
    • 2019
  • The vacuum preloading method has been used in many countries for ground improvement and land reclamation works. A sand cushion is required as a horizontal drainage channel for conventional vacuum preloading. In terms of the dredged-fill foundation soil, the treatment effect of the conventional vacuum preloading method is poor, particularly in Tianjin, China, where a shortage of sand exists. To solve this problem, straight-line vacuum preloading without sand is widely adopted in engineering practice to improve the foundation soil. Based on the engineering properties of dredged fill in Lingang City, Tianjin, this paper presents field instrumentation in five sections and analyzes the effect of a prefabricated vertical drain (PVD) layout and a vacuum pumping method on the soft soil ground treatment. Through the arrangement of pore water pressure gauges, settlement marks and vane shear tests, the settlement, pore water pressure and subsoil bearing capacity are analyzed to evaluate the effect of the ground treatment. This study demonstrates that straight-line vacuum preloading without sand can be suitable for areas with a high water content. Furthermore, the consolidation settlement and consolidation degree system is developed based on the grey model to predict the consolidation settlement and consolidation degree under vacuum preloading; the validity of the system is also verified.

Lateral-resisting Structural Systems for Tall Modular Buildings (모듈러 건축물의 수평력 저항 구조시스템)

  • Lee, Chang-Hwan;Chung, Kwang-Ryang
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.2
    • /
    • pp.79-88
    • /
    • 2016
  • Modular buildings are constructed by assembling modular units which are prefabricated in a factory and delivered to the site. However, due to a problem of noise between floors, concrete slab is usually poured at the top or bottom level of a modular unit in Korea. This greatly increases the weight of buildings, but designing vertical members of modular units to resist overall gravity loads is very inefficient. In this study, considering domestic building construction practices, feasible structural systems for tall modular buildings are proposed in which separate steel frames and reinforced concrete core walls are designed to resist gravity and lateral loads. To verify performance, a three-dimensional structural analysis has been performed with two types of prototype buildings, i.e., a residential building and a hotel. From the results, wind-induced lateral displacements and seismic story drifts are examined and compared with their limit values. Between the two kinds of buildings, the efficiency of the proposed system is also evaluated through a comparison of the weight of structural components. Finally, the effect of a floor diaphragm on the overall behavior is analyzed and discussed.

Research on cold-formed steel connections: A state-of-the-art review

  • Qin, Ying;Chen, Zhihua
    • Steel and Composite Structures
    • /
    • v.20 no.1
    • /
    • pp.21-41
    • /
    • 2016
  • Cold-formed steel structures are increasingly attractive due to their benefits of good mechanical performance and constructional advantages. However, this type of construction is still not fully exploited as a result of the acknowledged difficulties involved in forming construction-efficient and cost-effective connections. Furthermore, there is a lack of information on the structural behavior of the cold-formed steel connections. In this study, the research on various cold-formed steel connections was comprehensively reviewed from both fundamental and structural points of view, based on the available experimental and analytical data. It reveals that the current design codes and guidelines for cold-formed steel connections tend to focus more on the individual bearing capacity of the fasteners rather than the overall structural behavior of the connections. Significant future work remains to be conducted on the structural performance of cold-formed steel connection. In addition, extensive previous research has been carried out to propose and evaluate an economical and efficient connection system that is obtained from the conventional connecting techniques used in the hot-rolled industry. These connecting techniques may not be suitable, however, as they have been adopted from hot-rolled steel portal frames due to the thinness of the sheet in cold-formed steels. The review demonstrates that with the increasing demand for cold-formed steel constructions throughout the world, it is crucial to develop an efficient connection system that can be prefabricated and easily assembled on site.

A Development of Explicit Algorithm for Stress-Erection Analysis of STRARCH System (스트라치 시스템의 긴장응력해석을 위한 명시적 해석법의 개발)

  • Lee, Kyoung-Soo;Han, Sang-Eul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.5
    • /
    • pp.513-520
    • /
    • 2011
  • In this paper, the advanced explicit algorithm is proposed to simulate the stress-erection process analysis of Strarch system. The Strarch(Stressed-Arch) system is a unique and innovative structural system and member prestress comprising prefabricated plane truss frames which are erected by a post-tensioning stress-erection procedure. The flexible bottom chord which have sleeve and gap detail are closed by the reaction force of prestressing tendon. The prestress imposing to the tendon will make the Strarch system to be erected. This post tensioning process is called as "stress-erection process". During the stress-erection process, the plastic rigid body rotation is occurred to the flexible top chord by the excessive amount of plastic strain, and the structural characteristic becomes to be unstable. In this study, the large deformational beam-column element with plastic hinge is used to model the flexible top chord, and the advanced Dynamic Relaxation method(DRM) are applied to the unstable problem of stress-erection process of Strarch system. Finally, the verification of proposed explicit algorithm is evaluated by analysing the stress-erection of real project of Strarch system.

The behaviour of a new type of connection system for light-weight steel structures applied to roof trusses

  • Kaitila, Olli;Kesti, Jyrki;Makelainen, Pentti
    • Steel and Composite Structures
    • /
    • v.1 no.1
    • /
    • pp.17-32
    • /
    • 2001
  • The Rosette-joining system is a completely new press-joining method for cold-formed steel structures. One Rosette-joint has a shear capacity equal to that of approximately four screws or rivets. The Rosette thin-walled steel truss system presents a new fully integrated prefabricated alternative to light-weight roof truss structures. The trusses are built up on special industrial production lines from modified top hat sections used as top and bottom chords and channel sections used as webs which are joined together with the Rosette press-joining technique to form a completed structure easy to transport and install. A single web section is used when sufficient but can be strengthened by double-nesting two separate sections or by using two lateral profiles where greater compressive axial forces are met. An individual joint in the truss can be strengthened by introducing a hollow bolt into the joint hole. The bolt gives the connection capacity a boost of approximately 20%. A series of laboratory tests have been carried out in order to verify the Rosette truss system in practice. In addition to compression tests on individual sections of different lengths, tests have also been done on small structural assemblies and on actual full-scale trusses of a span of 10 metres. Design calculations have been performed on selected roof truss geometries based on the test results, FE-analysis and on the Eurocode 3 and U.S.(AISI) design codes.