• Title/Summary/Keyword: precision vaporizer

Search Result 9, Processing Time 0.028 seconds

The Isoflurane Concentration of Precision Vaporizer Goldman Vaporizer According to Room Temperature and Carrier Gas Flow Rate (온도 및 유량에 따른 흡입 마취제 전용 기화기와 Goldman 기화기의 isoflurane 농도 변화)

  • 김성미;장화석;이정선;최치봉;임희란;최준철;김휘율
    • Journal of Veterinary Clinics
    • /
    • v.21 no.3
    • /
    • pp.270-275
    • /
    • 2004
  • Anesthetic machines may be equipped with either a precision or nonprecision vaporizer. A precision vaporizer is designed to deliver an exact concentration of anesthetic agent. Goldman vaporizer is a low-flow, closed-circle circuit with a low resistance vaporizer, in circuit. Vaporizers used within circle system(VIC) are not usually temperature compensated and this is generally thought to be a disadvantage. As the volatile agent is vaporized, heat is extracted from the liquid and temperature decreases. This cooling of the liquid leads to a decrease in concentration of the anaesthetic agent delivered by the vaporizer. The purpose of this study is to examine the mechanical consistency of the delivery of isoflurane from Goldman vaporizer and precision vaporizer at various gas flow rates and temperatures. And we first studied isoflurane concentration according to room temperature changes delivered by a Goldman vaporizer and precision vaporizer using different gas flow. The room temperature of $15^{\circ}C,$ $20^{\circ}C,$ $28^{\circ}C$ and fresh gas flow rates of 0.5, 1.0, 1.5, 2.0, 3.0 l/min were used. The inspired agent concentration was measured using a Datex-Ohmeda multigas analyzer. As rose in room temperature, the isoflurane concentration of precision vaporizer approximated the dial setting. On the other hand, at a dial setting concentration of 5.0 percent the delivered isoflurane concentration of precision vaporizer was more than the dial setting in high temperature. The isoflurane concentration of precision vaporizer remained constant despite the increase in temperature. The isoflurane concentration of Goldman vaporizer was increased with rise in room temperature and decreased with rise in gas flow.

Optimum Design of Vaporizer Fin with Liquefied Natural Gas by Numerical Analysis

  • Jeong Hyo-Min;Chung Han-Shik;Lee Sang-Chul;Kong Tae-Woo;Yi Chung-Seub
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.545-553
    • /
    • 2006
  • Generally, the temperature drop under $0^{\circ}C$ on vaporizer surface creates frozen dews. This problem seems to increase as the time progress and humidity rises. In addition, the frozen dews create frost deposition. Consequently, heat transfer on vaporizer decreases because frost deposition causes adiabatic condition. Therefore, it is very important to solve this problem. This paper aims to study of the optimum design of used vaporizer at local LNG station. In this paper, experimental results were compared with numerical results. Geometries of numerical and experimental vaporizers were identical. Studied parameters of vaporizer are angle between two fins $(\Phi)$ and fin thickness $(TH_F)$. Numerical analysis results were presented through the correlations between the ice layer thickness $(TH_{ICE})$ on the vaporizer surface to the temperature distribution of inside vaporizer $(T_{IN})$, fin thickness $(TH_F)$, and angle between two fins $(\Phi)$. Numerical result shows good agreement with experimental outcome. Finally, the correlations for optimum design of vaporizer are proposed on this paper.

Study on the Effect of Season Conditions to the Performance of Longitudinally-Finned Air-Heating Vaporizer

  • Djajadiwinata, Eldwin;Lee, Yong-Hun;Kim, Pil-Hwan;Park, Gi-Tae;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2321-2326
    • /
    • 2007
  • To return LNG to a gaseous state, it is fed into a regasification plant. For inland area, where pipelines do not exist or difficult to construct, the LNG is delivered to the inland-receiving terminal available at that area, regasified and delivered to consumers. At inland-receiving terminal, air-heating vaporizer type is usually used. To contribute in developing an efficient air-heating vaporizer, experiment on finned type air-heating vaporizer using 8 fins, 50 mm fin length (8fin50le) and 4 fins, 75 mm fin length (4fin75le) were conducted. The experiments were conducted by varying the ambient condition and the length of the vaporizer. The ambient air was controlled so that it has the same condition with air condition in every season available. $LN_2$ is used to substitute LNG because of safety reason. The results show that characteristics of the finned type 4fin75le vaporizer are comparable to finned type 8fin50le vaporizer at all season.

  • PDF

Experimental Study on the Gasification Characteristics of Liquefied Gas Vaporizer with Various Shape (다양한 형상을 갖는 액화가스 기화기의 기화특성에 관한 실험적 연구)

  • Lee Yong-Hun;Lee Sang-Chul;Jeong Hyo-Min;Chung Han-Shik
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.2 no.1
    • /
    • pp.1-7
    • /
    • 2006
  • This paper was studied for optimum design of the used vaporizer at a satellite station. Generally, the cold air is created by temperature drop on the vaporizer surface. In addition, the frost creates ice deposit layer, therefore, heat transfer on vaporizer decreases into the adiabatic condition. By this reason, recent vaporizer system is installed as parallel type, and it takes three times of vaporizer capacity. But this vaporizer system requires much installation costs and restricted by some space. It is very important to solve this problem. This study paper is regarding $LN_2$ vaporizer where the utilization increases recently. There are three variable conditions which are used in this study research. First, fin lengths of 4000mm, 6000mm, 8000mm and 0, 4, 8 fin types were applied rut each vaporizer. Second, we applied four season condition which consist of humidity, temperature and air velocity to the experimental environment. Finally, pressure was applied to get flow rate during experiment. This paper objective is to propose vaporizer type and length data for best performance of vaporizer through experiment.

  • PDF

Simultaneous Determination of Pesticides in Water Using a GC/MS Coupled with Micro Extraction by Packed Sorbent (MEPS-GC/MS를 이용한 농약류 동시 수질분석)

  • Lee, Ki-chang;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.5
    • /
    • pp.262-268
    • /
    • 2015
  • This study established an analytical method to simultaneously determine six organophosphorous pesticides [methyldemetone-S, diazinon, fenitrothion, parathion, phentoate, and O-ethyl O-(4-nitrophenyl) phenylphosphonothioate (EPN)] and carbaryl in water using a gas chromatography/mass spectrometry (GC/MS) system coupled with on-line micro extraction by packed sorbent (MEPS) and programmed temperature vaporizer (PTV) injector. Polystyrene divinylbenzene (PDVB) was used as a sorbent of MEPS. The effects of elution solvents, pH, elution volume and draw-eject cycles of samples on sample pretreatment process were investigated. Also, quality assurance and quality control (QA/QC) and the recovery of the pesticides in environmental samples were evaluated. The elution was performed using $30{\mu}L$ of a mixed solvent (acetone : dichloromethane = 80 : 20 (v/v)). Sample pretreatment processes were optimized with seven cycles of draw-eject of sample (1 mL) spiking an internal standard and sulfuric acid. At lower pH, the analytical sensitivity of diazinon decreased, but that of carbaryl increased. The method detection limit and the limit of quantification for this method were 0.02~0.18 and $0.08{\sim}0.59{\mu}g/L$, respectively. The method precision and accuracy were 1.5~11.5% and 83.3~129.8%, respectively, at concentrations of $0.5{\sim}5.0{\mu}g/L$. The recovery rates for all the pesticides except carbaryl in various environmental samples ranged 75.7~129.3%. The recovery rate of carbaryl in effluent sample was over 200% whereas carbaryl in drinking water, groundwater, and river water were in the acceptable range.