• Title/Summary/Keyword: precision motion control

Search Result 587, Processing Time 0.029 seconds

A Design Control System of Hybrid Underwater Glider and Performance Test (하이브리드 수중 글라이더의 제어 시스템 설계 및 성능 시험)

  • Ji, Dae-hyeong;Choi, Hyeung-sik;Kim, Joon-young;Jung, Dong-wook;Jeong, Seong-hoon
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.1
    • /
    • pp.21-29
    • /
    • 2017
  • In this paper, we studied the control of the hybrid underwater glider (HUG), which has the advantage of high precision route search function and long-term mission capability. Dynamic modeling of HUG is based on numerical model of the attitude controller and buoyancy engine, thruster. We designed the control part considering the smooth control and precise sailing of HUG. A buoyancy engine capable of inhaling water is designed to control the buoyancy of HUG. And mass shifter carrying the battery was designed for controlling pitching motion of HUG. A control system for controlling the buoyancy engine and the attitude controller was constructed. In order to verify performance, we performed water tank test using manufactured HUG.

Flow Analysis and Experimental Study of Globe Valve for Precision Control (정밀 제어 글로브 밸브의 유동해석 및 실험적 연구)

  • Choi, Ji-Won;Park, Sun-Hyung;Lee, Kwon-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.734-739
    • /
    • 2016
  • The globe valve is a linear motion valve that is designed primarily to stop, start, and regulate flow. The disk of a globe valve can be removed totally from the flow path or it can completely close the flow path. In this study, numerical analysis using ANSYS-CFX was initially performed to predict the flow coefficient and build a prototype model of a globe valve. The flow coefficient is the volume of water at $15.6^{\circ}C$ that will flow per minute through a valve with a pressure drop of 1 psi across the valve. In other words, it is an important factor for determining the size of the valve. From the analysis results, the fluid flux of water and flow coefficient of the valve were extracted. From the numerical results, a prototype of ultra-fine precision control valve, which can regulate the fluid flow of range 0 ~ 0.1 gal per min, was developed. The experimental results were compared with the numerical results using the flow coefficient ($C_v$) graph. From the comparative results, the flow coefficient ($C_v$) error percentage between the numerical and experimental results was very low, which is acceptable, proving that the proposed prototype model is convincing. In addition, it is possible to predict the flow coefficient using only numerical analysis.

Development and Preliminary Performance Analysis of a fast and high precision Tracking Mount for 1m Satellite Laser Ranging (1m급 인공위성 레이저추적 시스템용 고속·고정밀 추적마운트 개발 및 예비 성능분석)

  • Choi, Man-Soo;Lim, Hyung-Chul;Lee, Sang-Jung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.11
    • /
    • pp.1006-1015
    • /
    • 2016
  • This paper presents preliminary design and performance analysis of a fast and high precision Tracking Mount for 1m Satellite Laser Ranging(SLR) which is development by Korea Astronomy and Space science Institute(KASI). SLR is considered to be the most accurate technique currently available for the precise orbit determination of Earth satellites. The SLR technique measures the time of flight between pulses emitted from laser transmitter and pulses returned from satellites with laser retro-reflector array. It provides millimeter level precision of range measurements between SLR stations and satellites. A fast and high precision Tracking Mount for SLR which is proposed in this research should be capable of day and nighttime laser tracking about the satellites with laser reflectors from 200 km to 36,000 km altitude(geosynchronous orbit). In order to meet this requirement, we performed mechanical design and structural analysis for Tracking Mount. Also we designed the motion control system and conducted pre-performance analysis to obtain good performance results for a fast and high precision Tracking Mount.

Real-Time Determination of Relative Position Between Satellites Using Laser Ranging

  • Jung, Shinwon;Park, Sang-Young;Park, Han-Earl;Park, Chan-Deok;Kim, Seung-Woo;Jang, Yoon-Soo
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.4
    • /
    • pp.351-362
    • /
    • 2012
  • We made a study on real-time determination method for relative position using the laser-measured distance data between satellites. We numerically performed the determination of relative position in accordance with extended Kalman filter algorithm using the vectors obtained through nonlinear equation of relative motion, laser simulator for distance measurement, and attitude determination of chief satellite. Because the spherical parameters of relative distance and direction are used, there occur some changes in precision depending on changes in relative distance when determining the relative position. As a result of simulation, it was possible to determine the relative position with several millimeter-level errors at a distance of 10 km, and sub-millimeter level errors at a distance of 1 km. In addition, we performed the determination of relative position assuming the case that global positioning system data was not received for long hours to see the impact of determination of chief satellite orbit on the determination of relative position. The determination of precise relative position at a long distance carried out in this study can be used for scientific mission using the satellite formation flying.

Development of a Redundant Shoulder Complex Actuated by Metal Wire Tendons (텐던 구동 기반 여유자유도를 가지는 로봇의 어깨 메커니즘 구현)

  • Choi, Taeyong;Kim, Doohyung;Do, Hyunmin;Park, Chanhun;Park, Dongil
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.10
    • /
    • pp.853-858
    • /
    • 2016
  • Cooperation and collaboration with robots are key functions of robotic utility that are currently developing. Thus, robots should be safe and resemble human beings to cope with these needs. In particular, dual-arm robots that mimic human kinetics are becoming the focus of recent industrial robotics research. Their size is similar to the size of a human adult; however, they lack natural, human-like motion. One of the critical reasons for this is the shoulder complex. Most recent dual-arm robots have only 2 degrees of freedoms (DOFs), which significantly limits the workspace and mobility of the shoulders and arms. Therefore, a redundant shoulder complex could be very important in new developments that enable new capabilities. However, constructing a kinematically redundant shoulder complex is difficult because of spatial constraints. Therefore, we propose a novel, redundant shoulder complex for a human-like robot that is driven by flexible wire tendons. This kinematically redundant shoulder complex allows human-like robots to move more naturally because of redundant DOFs. To control the proposed shoulder complex, a hybrid control scheme is used. The positioning precision has also been considered, and the ability of the shoulder complex to perform several human-like motions has been verified.

A Study on Kinematical Modeling and Analysis of Double Side Wafer Polishing Process (실리콘 웨이퍼 양면 연마 공정의 기구학적 모델링과 해석에 관한 연구)

  • Lee, Sang-Jik;Jeong, Suk-Hoon;Lee, Hyun-Seop;Park, Sun-Joon;Kim, Young-Min;Jeong, Hae-Do
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.485-485
    • /
    • 2009
  • Double side polishing process has been used for various industrial applications, such as polishing of semiconductor substrates and flat panel display glasses. In wafer manufacturing, double side polishing process is applied to improve wafer flatness and to minimize particle generation from wafers in device manufacturing processes, which is recognized as one of the most important processes. Whereas the kinematical modeling and analysis results of single side polishing, extensively used for chemical-mechanical polishing (CMP) in device manufacturing, are well investigated, the studies in conjunction with double side polishing are barely carried out, due to the complication of polishing system and the uncertainty of wafer motion in the carrier. This paper suggests the derivation of kinematical model with consideration of carrier and wafer motion in double side polishing, and then presents the effect of kinematical parameters on material removal amount and its non-uniformity. The kinematical analysis results help to understand the double side polishing process and to control the polishing results.

  • PDF

The Design of an Intelligent Assembly Robot System for Lens Modules of Phone Camera.

  • Song, Jun-Yeob;Lee, Chang-Woo;Kim, Yeong-Gyoo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.649-652
    • /
    • 2005
  • The camera cellular phone has a large portion of cellular phone market in recent year. The variety of a customer demand makes a fast model change and the spatial resolution is changed from VGA to multi-mega pixel. The 1.3 mega pixel (MP) camera cellular phone was first released into the Korean market in October 2003. The major cellular phone companies released a 2MP camera cellular phone that supports zoom function and a 2MP camera cellular phone is settled down with the Korea cellular phone market. It makes a keen competition in price and demands automation for phone camera module. There is an increasing requirement for the automatic assembly to correspond to a fast model change. The hard automation techniques that rely on dedicated manufacturing system are too inflexible to meet this requirement. Therefore in this study, this system is designed with the flexibility concept in order to cope with phone camera module change. The system has a same platform that has X-Y-Z motion or X-Z motion with ${\mu}m$order accuracy. It has a special gripper according to the type of a component to be put together. If the camera model changes, the gripper may be updated to fit for the camera module. The controller of this system acquires the data sets that have the information about the assembly part by the tray. This information is obtained ahead of an inspection step. The controller excludes an inferior part to be assembled by using this information to diminish the inferior goods. The assembly jig used in this system has a function of self adjustment that reduces the tact time and also diminish the inferior goods. Finally, the intelligent assembly system for phone camera module will be designed to get a flexibility to meet model change and a high productivity with a high reliability.

  • PDF

A Development of the Automated System for Adjusting the Hexapod Circular Fixator (6자유도 원형체외고정기 조정을 위한 자동화 시스템 개발에 관한 연구)

  • Jung S. G.;Park B. S.;Sim H. J.;Han C. S.;Han J. S.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.505-510
    • /
    • 2004
  • In this article, we present an automated system for adjusting the 6 degree of freedom (D.O.F.) circular fixator. The system includes a scheduling software to adjust the Hexapod Circular Fixator (HCF) and an automated strut with the ability of the multiple synchronized motion and independent motion. The HCF was designed to control a 6 D.O.F. Ilizarov fixator and it's mechanism. The HCF adjustment software evaluates each value of altered length of the HCF struts to correct the complex skeletal deformity by using the X-ray data of the patient. The data of HCF adjustment software feed into the automated strut system which provides the scheduled adjustment. Then, the automated strut is synchronized by input data. Also the data of HCF adjustment software can be used to adjust HCF without automated struts. The proposed HCF system was verified by experiments.

Study on Efficacy of Gait Training for Hemiplegia Patients Using Lower-Limb Wearable Robot (착용형 하지 로봇을 이용한 편마비 보행 재활 훈련 효과에 관한 연구)

  • Ji, Younghoon;Yun, Deokwon;Jang, Hyeyoun;Lee, Dongbock;Khan, Abdul Manan;Kim, Sol;Kim, Mijung;Han, Jungsoo;Han, Changsoo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.10
    • /
    • pp.879-883
    • /
    • 2015
  • Conventional gait rehabilitation requires at least three therapists in a traditional rehabilitation training program. Several robots have been developed to reduce human burden and increase rehabilitation efficacy. In this study, we present a lower-limb wearable robot (WA-H) for gait rehabilitation of hemiplegia patients, and propose a protocol of 12 weeks gait rehabilitation training program using WA-H. To identify the efficacy of the robot and protocols, we conducted a clinical study with two actual hemiplegia patients and observed a chronological change of ambulation ability through four assessments. We discovered the progression of results by 6 minute walking test, TUGT (Timed Up and Go Test), SPPB (Short Physical Performance Battery), BBS (Berg Balance Test), and Fugl-Meyer score. The torques generated in the normal side and paralyzed side of the patient became similar, indicating rehabilitation. The result also showed the walking of the paralysis patient improved and imbalance motion had considerable improved performance.

Development of ISO14649 Compliant CNC Milling Machine Operated by STEP-NC in XML Format

    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.4 no.5
    • /
    • pp.27-33
    • /
    • 2003
  • G-code, another name of ISO6983, has been a popular commanding language for operating machine tools. This G-code, however, limits the usage of today's fast evolving high-performance hardware. For intelligent machines, the communications between machine and CAD/CAM departments become important, but the loss of information during generating G-code makes the production department isolated. The new standard for operating machine tools, named STEP-NC is just about to be standardized as ISO14649. As this new standard stores CAD/CAM information as well as operation commands of CNC machines, and this characteristic makes this machine able to exchange information with other departments. In this research, the new CNC machine operated by STEP-NC was built and tested. Unlike other prototypes of STEP-NC milling machines, this system uses the STEP-NC file in XML file form as data input. This machine loads information from XML file and deals with XML file structure. It is possible for this machine to exchange information to other databases using XML. The STEP-NC milling machines in this research loads information from the XML file, makes tool paths for two5D features with information of STEP-NC, and machines automatically without making G-code. All software is programmed with Visual $C^{++}$, and the milling machine is built with table milling machine, step motors, and motion control board for PC that can be directly controlled by Visual $C^{++}$ commands. All software and hardware modules are independent from each other; it allows convenient substitution and expansion of the milling machine. Example 1 in ISO14649-11 having the full geometry and machining information and example 2 having only the geometry and tool information were used to test the automatic machining capability of this system.