• 제목/요약/키워드: pre-signal

검색결과 721건 처리시간 0.024초

병원전 단계 심폐소생술을 위한 호흡 모니터링 시스템 (Respiration monitoring system for pre-hospital CPR)

  • 이인광;김도경;차은종;김경아
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2053-2054
    • /
    • 2011
  • Cardiopulmonary resuscitation(CPR) is performed by artificial ventilation and thoracic compression for the patient under emergent situation to maintain at least the minimum level of respiration and blood circulation for life survival. Good quality CPR requires monitoring respiration. We developed a system for continuous monitoring respirational signal while CPR, using respirational airflow sensor for CPR. Signal extraction circuit obtains pressure signal while CPR. Obtained signal would be performed analog-digital conversion and changed to airflow value by characteristic formula. Single inspiration and expiration were considered a period. Detected valid data were displayed LCD.

  • PDF

계란 크랙의 온라인 검출 (On-line Detection of Cracks in Eggshell)

  • 최완규;조한근;백진하;장영창;연광석;조성찬
    • Journal of Biosystems Engineering
    • /
    • 제24권3호
    • /
    • pp.253-258
    • /
    • 1999
  • This study was conducted to develop an automatic egg inspection system for detecting creaked eggs based on acoustic impulse response. This system includes a sound generator, a sound sensor with signal conditioner, and a computer. The sound generator that hit the sharp of the dull edges of an egg was constructed with a ceramic ball pendulum attached to a rotary type solenoid. The signal conditioner included a pre-amplifier and a digital signal processing (DSP) board. The parameters for distinguishing cracked and normal eggs were the area, the geometric centroid and the resonance frequency of power spectrum of the acoustic signal generated. An algorithm for on-line detection of the continuous transferring eggs was developed. The performance tests resulted with 91% success rate to separate cracked and normal eggs at the rate of 1 second per an egg.

  • PDF

적응 디지탈 필터를 이용한 확성용 스피커의 선형 왜곡 보상 (A Compensation of Linear Distortion for Loudspeaker Using the Adaptive Digital Filter)

  • 전희영;차일환
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 1995년도 학술대회
    • /
    • pp.165-170
    • /
    • 1995
  • In this paper, it is attempted to apply the adaptive digital signal processing to compensate for a linear distortion of a loudspeaker and implement a real time hardware for that purpose. The real time system is implemented by using the DSP56001, a general purpose signal processor, as a host processor and the DSP56200, a cascadable adaptive FIR filter peripheral chip, as an adaptive digital filter. The system has 1000 taps at a 44.1kHz. After inverse modeling of under_compensation_speaker, the system reduces loudspeaker's linear distortions by pre-processing an input audio signal to loudspeaker. The experiment shows satisfactory results; after adaption with white noise as input signal for 60sec, the flat amplitude and linear phase frequency characteristics is found to lie over a wide frequency range of 100Hz to 20kHz.

Pre-reservation of Resources and Controlled Loops for Contention Resolution in OBS Networks

  • Comellas, Jaume;Conesa, Josep;Padaro, Salvatore;Junyent, Gabriel
    • ETRI Journal
    • /
    • 제29권5호
    • /
    • pp.682-684
    • /
    • 2007
  • A new scheme to alleviate contention in optical burst switching networks is proposed. It consists of preventively reserving resources in a node, to be used if resources are busy on the next hop node. The burst is sent back to the preceding node and then resent forward. Simulations are carried out to assess the feasibility of the proposed scheme. Its performance is compared with that of contention resolution based on deflection routing.

  • PDF

Heart Sound Recognition by Analysis of wavelet transform and Neural network.

  • Lee, Jung-Jun;Lee, Sang-Min;Hong, Seung-Hong
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 ITC-CSCC -2
    • /
    • pp.1045-1048
    • /
    • 2000
  • This paper presents the application of the wavelet transform analysis and the neural network method to the phonocardiogram (PCG) signal. Heart sound is a acoustic signal generated by cardiac valves, myocardium and blood flow and is a very complex and nonstationary signal composed of many source. Heart sound can be discriminated normal heart sound and heart murmur. Murmurs have broader frequency bandwidth than the normal ones and can occur at random position of cardiac cycle. In this paper, we classified the group of heart sound as normal heart sound(NO), pre-systolic murmur(PS), early systolic murmur(ES), late systolic murmur(LS), early diastolic murmur(ED). And we used the wavelet transform to shorten artifacts and strengthen the low level signal. The ANN system was trained and tested with the back- propagation algorithm from a large data set of examples-normal and abnormal signals classified by expert. The best ANN configuration occurred with 15 hidden layer neurons. We can get the accuracy of 85.6% by using the proposed algorithm.

  • PDF

Arbitrary Sampling Method for Nonlinearity Identification of Frequency Multipliers

  • Park, Young-Cheol;Yoon, Hoi-Jin
    • Journal of electromagnetic engineering and science
    • /
    • 제8권1호
    • /
    • pp.17-22
    • /
    • 2008
  • It is presented that sampling rates for behavioral modeling of quasi-memory less nonlinear devices can be far less than the Nyquist rate of the input signal. Although it has been believed that the sampling rate of nonlinear device modeling should be at least the Nyquist rate of the output signal, this paper suggests that far less than the Nyquist rate of the input signal can be applied to the modeling of quasi-memoryless nonlinear devices, such as frequency multipliers. To verify, a QPSK signal at 820 MHz were applied to a frequency tripler, whereby the device can be utilized as an up-converting mixer into 2.46 GHz with the aid of digital predistortion. AM-AM, AM-PM and PM-PM can be successfully measured regardless of sampling rates.

Evaluation of Fracture Behavior of SA-516 Steel Welds Using Acoustic Emission Analysis

  • Na, Eui-Gyun;Ono, Kanji;Lee, Dong-Whan
    • Journal of Mechanical Science and Technology
    • /
    • 제20권2호
    • /
    • pp.197-204
    • /
    • 2006
  • The purpose of this study is to evaluate the AE characteristics for the basemetal, PWHT (post-weld heat treatment) and weldment specimens of SA-516 steel during fracture testing. Four-point bending and AE tests were conducted simultaneously. AE signals were emitted in the process of plastic deformation. AE signal strength and amplitude of the weldment was the strongest, followed by PWHT specimen and basemetal. More AE signals were emitted from the weldment samples because of the oxides, and discontinuous mechanical properties. AE signal strength and amplitude for the basemetal or PWHT specimen decreased remarkably compared to the weldment because of lower strength. Pre-cracked specimens emitted even lower event counts than the corresponding blunt notched specimens. Dimple fracture from void coalescence mechanism is associated with low-level AE signal strength for the basemetal or PWHT. Tearing mode and dimple formation were shown on the fracture surfaces of the weldment, but only a small fraction produced detectable AE.

Electrochemical Signal Amplification by Gap Electrodes and Control of Gap Distances

  • Park, Dae Keun
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권3호
    • /
    • pp.197-200
    • /
    • 2019
  • We report on electrochemical signal amplification using gap electrodes based on the redox cycling between gap electrodes. The distance between electrodes was controlled from $2{\mu}m$ to a few hundreds of nanometer by chemical deposition of reduced Au ion on the pre-defined electrodes. Enhanced redox current of ferri/ferrocyanide was obtained by redox cycling between the two working electrodes. The faradaic current is amplified about a thousand times in this redox system. Since the signal amplification is due to the shortened diffusion length between the two electrodes, the narrower the nanogap was, the better detection limit, calibration sensitivity, and dynamic range. The experimental results were discussed on the basis of the cyclic voltammetry (CV), atomic force microscope (AFM) and scanning electron microscope (SEM) measurements.

불균일 클러터 환경에서 다중 표적탐지 성능 향상을 위한 반복 백색화 투영 통계 기법 (Iterative Pre-Whitening Projection Statistics for Improving Multi-Target Detection Performance in Non-Homogeneous Clutter)

  • 박혁;강진환;김상효
    • 대한전자공학회논문지SP
    • /
    • 제49권4호
    • /
    • pp.120-128
    • /
    • 2012
  • 본 논문에서는 불균일한 클러터 환경에서 다중 표적탐지 성능을 향상시키기 위한 변형된 반복 백색화 투영 통계(modified iterative pre-whitening projection statistics: MIPPS) 기법을 제안하였다. MIPPS 기법은 항공기용 레이더에서 사용하는 시공간 적응 처리(space-time adaptive processing) 알고리듬의 불균일성 검출(non-homogeneity detection: NHD) 기법으로 반사신호 세기가 서로 다른 다수의 표적이 근접거리에 혼재되어 있는 환경에서 우수한 표적탐지 성능을 나타낸다. 모의실험을 통해 기존의 다양한 NHD 기법들의 성능을 분석하고, 본 논문에서 제안하는 MIPPS 기법이 강한 표적신호에 의해 야기되는 마스킹 효과(masking effect)를 최소화하면서 반사신호 세기가 약한 표적에 대한 평균 탐지 확률을 향상시킬 수 있음을 확인하였다.

심전도와 심탄도의 무구속적 동시 측정을 위한 의자 등받이 개발 (Development of Chair Backrest for Non-intrusive Simultaneous Measurement of ECG and BCG)

  • 임용규
    • 융합신호처리학회논문지
    • /
    • 제19권3호
    • /
    • pp.104-109
    • /
    • 2018
  • 심전도와 심탄도를 무구속적으로 동시에 측정하는 시스템을 개발하였다. 제안된 시스템은 의자의 보조 등받이에 설치되어 맥파전달시간(PAT), Pre-ejection period (PEP) 등의 심혈관계 역학 정보를 일상생활에서 무구속적으로 측정하는 것을 목적으로 개발되었다. 본 연구에서는, 의자의 등받이에 부착된 용량성 능동전극과 용량성 접지를 이용한 간접접촉 심전도 (IDC-ECG) 측정 방법에 의해 무구속적으로 심전도를 측정하였으며, 등받이에 부착된 EMFi 압력 센서를 사용하여 무구속적으로 심탄도(ballistocardiogram)를 측정하였다. 제안된 시스템으로 심전도와 심탄도가 무구속적으로 동시에 측정됨을 확인하였으며, 측정된 심탄도는 피검자 사이에서 일정한 패턴을 보이는 것을 알 수 있었다. 또한 심전도의 Q파와 심탄도의 첫 번째 첨두간의 시간차가 pre-ejection period와 높은 상관관계를 보이는 것도 확인할 수 있었다. 이 연구에서 개발된 시스템은 심혈관계의 다양한 지표(심전도, 심박수, PAT, PEP 등)를 무구속적으로 일상생활에서 측정할 수 있음을 보였다.