• Title/Summary/Keyword: pre-inflow

Search Result 51, Processing Time 0.024 seconds

Physical Model Investigation of a Compact Waste Water Pumping Station

  • Kirst, Kilian;Hellmann, D.H.;Kothe, Bernd;Springer, Peer
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.4
    • /
    • pp.285-291
    • /
    • 2010
  • To provide required flow rates of cooling or circulating water properly, approach flow conditions of vertical pump systems should be in compliance with state of the art acceptance criteria. The direct inflow should be vortex free, with low pre-rotation and symmetric velocity distribution. Physical model investigations are common practice and the best tool of prediction to evaluate, to optimize and to document flow conditions inside intake structures for vertical pumping systems. Optimization steps should be accomplished with respect to installation costs and complexity on site. The report shows evaluation of various approach flow conditions inside a compact waste water pumping station. The focus is on the occurrence of free surface vortices and the evaluation of air entrainment for various water level and flow rates. The presentation of the results includes the description of the investigated intake structure, occurring flow problems and final recommendations.

THE INFLUENCES OF SWIRL FLOW ON FRACTIONAL FLOW RESERVE IN MILD/MODERATE/SEVERE STENOTIC CORONARY ARTERIAL MODELS (관상동맥 내의 나선형 유동이 협착도에 따라 분획 혈류 예비능에 미치는 영향에 관한 수치해석)

  • Lee, Kyung Eun;Kim, Gook Tae;Ryu, Ah-Jin;Shim, Eun Bo
    • Journal of computational fluids engineering
    • /
    • v.22 no.1
    • /
    • pp.15-25
    • /
    • 2017
  • Swirl flow is often found in proximal coronary arteries, because the aortic valves can induce swirl flows in the coronary artery due to vortex formation. In addition, the curvature and tortuosity of arterial configurations can also produce swirl flows. The present study was performed to investigate fractional flow reserve alterations in a post-stenotic distal part due to the presence of pre-stenotic swirl flow by computational fluid dynamics analysis for virtual stenotic models by quantifying fractional flow reserve(FFR). Simplified stenotic coronary models were divided into those with and without pre-stenotic swirl flow. Various degrees of virtual stenosis were grouped into three grades: mild, moderate, and severe, with degree of stenosis of 0 ~ 40%, 50 ~ 60%, and 70 ~ 90%, respectively. In this study, three-dimensional computational hemodynamic simulations were performed under hyperemic conditions in virtual stenotic coronary models by coupling with a zero-dimensional lumped parameter model. The results showed that the influence of pre-stenotic swirl inflow is dominant on FFR alteration in mild stenosis, whereas stenosis is dominant on FFR alteration in moderate/severe stenosis. The decrease in FFR caused by swirl flow is more significant in mild stenosis than moderate/severe stenosis. Biomechanical modeling is useful for clinicians to provide insight for medical intervention strategies. This hemodynamic-based parameter study could play a critical role in the development of a non-invasive imaging-based strategy-support system for percutaneous transluminal angioplasty in cases of mild/moderate stenosis.

Development of Reservoir Operation Model using Simulation Technique in Flood Season (I) (모의기법에 의한 홍수기 저수지 운영 모형 개발 (I))

  • Sin, Yong-No;Maeng, Seung-Jin;Go, Ik-Hwan;Lee, Hwan-Gi
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.6
    • /
    • pp.745-755
    • /
    • 2000
  • The dam operation system of KOWACO for flood control doesn't have capability to account for the downstream hydrologic conditions and any feasible index to decide the pre-release from the forecasted rainfall and inflow. In this study, a dam operation model for flood control was developed to account for the flood flow condition of its downstream to give users the dam release schedules. Application test of EV ROM to Keum River showed that EV ROM is superior to the Rigid ROM and Technical ROM which are currently used by KOWACO. EV ROM developed in this study provides a release schedule accounting for the cumulative lateral flow hydrograph at the downstream control points where the discharge does not depend only on the dam operation. but also on lateral inflow from the tributaries. In order to reduce the peak discharge at the control points, it suggests the preliminary release during the early rising phase of the predicted hydrograph, holding the flood flow inside the dam during a peak phase, and afterward resuming the release. Three case studies of flood control by the operation of Daechung Multipurpose Dam in Geum River Basin show that the EV ROM is superior to the Rigid ROM and Technical ROM. This must be due to its nature to account for the downstream flow condition as well as the inflow and water level of the dam. It was also conceived that further case studies of EV ROM and more accurate rainfall prediction would improve the dam operation for flood control.ontrol.

  • PDF

Substitutability of coagulation process by pre-treatment of coagulation·flotation using natural algae coagulant (천연조류제거제를 활용한 응집·부상 전처리공정의 기존 응집공정 대체 가능성)

  • Jang, Yeo-Ju;Jung, Jin-Hong;Lim, Hyun-Man;Chang, Hyang-Youn;Kim, Weon-Jae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.1
    • /
    • pp.39-50
    • /
    • 2017
  • In the coagulation/sedimentation (C/S) process of the water treatment process, the inflow of massive algal bloom causes many problems including fouling of filter media. This study was conducted to find out the way to remove the algae's harmful effects by addition of pre-treatment prior to C/S process. Many Jar-tests were conducted such as (1) ACF (Algae Coagulation Flotation) process using natural algae coagulant (Water $Health^{(R)}$), (2) ACF + C/S process and (3) C/S process with a variety of conditions using cultured algae. The average values of turbidity were (1) 0.42 NTU for ACF process, (2) 0.13 NTU for ACF + C/S process and (3) 0.25 NTU for C/S process. It was shown that the treatment efficiency of ACF process could get low turbidity results, and ACF + C/S process could achieve more efficient results than those of C/S process. Any negative effects of ACF process to the efficiency of C/S process were not observed in ACF + C/S process. In order to reduce the unfavorable effects of algae, it was found out that the introduction of ACF process in the forms of (1) ACF or (2) ACF + C/S could be one of the effective and alternative solutions.

A Study on the Shape of KRISO Propulsion Efficiency Improvement Devices(K-duct) using CFD (CFD를 이용한 KRISO 추진효율 향상 장치(K-duct) 형상 특성에 관한 연구)

  • Kim, Jin-wook;Suh, Sung-Bu
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.55 no.6
    • /
    • pp.474-481
    • /
    • 2018
  • This paper is to compare by numerical analysis the flow characteristics and propulsion performance of stern with the shape change of K-duct, a pre-swirl duct developed by Korea Research Institute of Ships & Ocean Engineering (KRISO). First, the characteristics of the propeller and the resistance and self-propulsion before and after the attachment of the K-duct to the ship were verified and the validity of the calculation method was confirmed by comparing this result with the model test results. After that, resistance and self-propulsion calculations were performed by the same numerical method when the K-duct was changed into five different shapes. The efficiency of the other five cases was compared using the delivery horsepower in the model scale and the flow characteristics of the stern were analyzed as the velocity and pressure distributions in the area between the duct end and the propeller plane. For the computation, STAR-CCM +, a general-purpose flow analysis program, was used and the Reynolds Averaged Navier-Stokes (RANS) equations were applied. Rigid Body Motion (RBM) method was used for the propeller rotating motion and SST $k-{\omega}$ turbulence model was applied for the turbulence model. As a result, the tangential velocity of the propeller inflow changed according to the position angle change of the stator, and the pressure of the propeller hub and the cap changes. This regulated the propeller hub vortex. It was confirmed that the vortex of the portion where the fixed blade and the duct meet was reduced by blunt change.

Nonlinear Modeling and Application of PI Control on Pre-cooling Session of a Carbon Dioxide Storage Tank at Normal Temperature and Pressure (상온 상압의 이산화탄소 저장용 탱크를 위한 예냉과정의 비선형 모델링 및 비례-적분 제어 적용)

  • Lim, Yu Kyung;Lee, Seok Goo;Dan, Seungkyu;Ko, Min Su;Lee, Jong Min
    • Korean Chemical Engineering Research
    • /
    • v.52 no.5
    • /
    • pp.574-580
    • /
    • 2014
  • Storage tanks of Carbon dioxide ($CO_2$) carriers utilized for the purpose of carbon capture and storage (CCS) into subsea strata have to undergo a pre-cooling session before beginning to load cryogenic liquid cargos in order to prevent physical and thermal deterioration of tanks which may result from cryogenic $CO_2$ contacting tank walls directly. In this study we propose dynamic model to calculate the tank inflow of $CO_2$ gas injected for precooling process and its dynamic simulation results under proportional-integral control algorithm. We selected two cases in which each of them had one controlled variable (CV) as either the tank pressure or the tank temperature and discussed the results of that decision-making on the pre-cooling process. As a result we demonstrated that the controlling instability arising from nonlinearity and singularity of the mathematical model could be avoided by choosing tank pressure as CV instead of tank temperature.

Numerical Analysis on the Flue Gas Flow and Slurry Behavior in the Absorber of a Flue Gas Desulphurization (FGD) System (배연탈황설비 흡수탑 내 연소가스 및 슬러리의 거동에 관한 수치해석적 연구)

  • Choi, Choeng-Ryul
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.4
    • /
    • pp.478-486
    • /
    • 2007
  • Numerical analysis had been performed to understand flow characteristics of the flue gas and slurry in the absorber of a flue gas desulphurization (FGD) system using computational fluid dynamics (CFD) technique. Two-fluid(Euler-Lagrangian) model had been employed to simulate physical phenomenon, which slurry particles injected through slurry spray nozzles fall down and bump into the flue gas inflowing through inlet duct. It was not necessary to adopt pre-defined pressure drop inside the absorber because interaction between flue gas and slurry particles was considered. Hundreds of slurry spray nozzles were considered with the spray velocity at the nozzles, swirl velocity and spreading angle. The results note that the flow disturbance of flue gas is found at the bottom of the absorber, and the current rising with high speed stream is observed in the opposite region of the inflow duct. The high speed stream is reduced as the flue gas goes up, because the high speed stream of flue gas dumps falling slurry particles due to momentum exchange between flue gas and slurry particles. In spite of some disproportion in slurry distribution inside the absorber, escape of slurry particles from the absorber facility is not observed. The pressure drop inside the absorber is mainly occurred at the bottom section.

Cultural Ecology on the Village Fengshui (마을풍수의 문화생태 - 지리산권역의 마을을 사례로 -)

  • Choi, Won-Suk
    • Journal of the Korean association of regional geographers
    • /
    • v.17 no.3
    • /
    • pp.259-269
    • /
    • 2011
  • The meaning of fengshui was another cultural ecological environment in the pre-modern in Korea. Village residents made interrelations with village natural environment by the medium of the geomantic landscape. The functions of cultural ecology through the village fengshui are as follows: the spatial location, the population inflow, the regulation of the community's production or construction or land-use, the adjustment of the environmental carrying capacity, the environmental management, the forming of the collective environmental perception and attitude. Village fengshui is a cultural adaptation strategy to the local environment for the village residents. Fengshui can be evaluated as a traditional cultural ecological way and knowledge system for keeping sustainable village environment in East Asia.

  • PDF

Comparison analysis of cooling loads according to window systems and balcony expansion for a high-rise residential building (초고층 공동주택에서 발코니 확장에 따른 창호시스템별 냉방부하 분석 및 비교)

  • Kim, Yun-Jin;Park, Sang-Hyun;Lee, Jong-Chan;Lim, Jung-Hee;Kim, Byung-Seon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.184-189
    • /
    • 2008
  • These days, Apartment is altered oversized and high-rise through construction techniques development. Also, the cost of cooling and heating load would be expected by balcony expansion into inner space caused by legalization. In specially, HVAC systems of high-rise residential building almost apply to pre-existence techniques of middle and low residential building except for consideration and methods of the air inflow minimization into indoor through mechanical ventilation is used in ventilation system. From these cause, window systems of high-rise apartments stands high in estimation of components. Thus, purpose of this study is to make a comparative study through difference of window systems.

  • PDF

Effectiveness of elimination inflowing algae in water treatment plant using natural algae remover (천연 조류 제거제를 이용한 정수장 유입 조류 제거 효율)

  • Jung, Hoyoung;Kim, Younghee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.4
    • /
    • pp.311-319
    • /
    • 2019
  • The purpose of this study was to analyze water treatment characteristics, including the efficiency of removing algae from water purification plants, by installing a demonstration facility for decontamination of algae, including natural algae remover injection equipment, in the water purification plant. Jar-test showed that the optimum injection of natural decontaminant was 20 mg/L. Of the water contaminant treatment efficiency of the intake and water purification plants, Chl-a averaged 74.0% elimination efficiency from $5.0mg/m^3$ to $1.3mg/m^3$ and the maximum treatment efficiency was 91.5% removal efficiency when the inflow concentration of Chl-a was $11.8mg/m^3$. In addition, 51.2% and 47.1% of the taste and odor indicator items, geosmin and 2-MIB, resulted from the overgrowth and decaying of algae, respectively, to identify toxic substances and odor reduction effects. In addition, elimination efficiencies of SS and Turbidity materials were higher than 70.0%. In the injection of natural algae remover, no effects such as sudden changes in water quality due to secondary reactions were found, and appropriate levels were maintained under water treatment conditions.