• Title/Summary/Keyword: ppd

Search Result 289, Processing Time 0.025 seconds

Environmental Modeling and Thermal Comfort in Buildings in Hot and Humid Tropical Climates

  • Muhammad Awaluddin Hamdy;Baharuddin Hamzah;Ria Wikantari;Rosady Mulyadi
    • Architectural research
    • /
    • v.25 no.4
    • /
    • pp.73-84
    • /
    • 2023
  • Indoor thermal conditions greatly affect the health and comfort of humans who occupy the space in it. The purpose of this research is to analyze the influence of water and vegetation elements as a microclimate modifier in buildings to obtain thermal comfort through the study of thermal environment models. This research covers two objects, namely public buildings and housing in Makassar City, South Sulawesi Prov-ince - Indonesia. Quantitative methods through field surveys and measurements based on thermal and personal variables. Data analysis based on ASHRAE 55 2020 standard. The data was processed with a parametric statistical approach and then simulated with the Computational Fluid Dynamics (CFD) simulation method to find a thermal prediction model. The model was made by increasing the ventilation area by 2.0 m2, adding 10% vegetation with shade plant characteristics, moving water features in the form of fountains and increasing the pool area by 15% to obtain PMV + 0.23, PPD + 8%, TSV-1 - +0, Ta_25.7℃, and relative humidity 63.5 - 66%. The evaluation shows that the operating temperature can analyze the visitor's comfort temperature range of >80% and comply with the ASHRAE 55-2020 standard. It is concluded that water elements and indoor vegetation can be microclimate modifiers in buildings to create desired comfort conditions and adaptive con-trols in buildings such as the arrangement of water elements and vegetation and ventilation systems to provide passive cooling effects in buildings.

Effect of anti-skin disorders of ginsenosides- A Systematic Review

  • Lele Cong;Jinli Ma;Yundong Zhang;Yifa Zhou;Xianling Cong;Miao Hao
    • Journal of Ginseng Research
    • /
    • v.47 no.5
    • /
    • pp.605-614
    • /
    • 2023
  • Ginsenosides are bioactive components of Panax ginseng with many functions such as anti-aging, anti-oxidation, anti-inflammatory, anti-fatigue, and anti-tumor. Ginsenosides are categorized into dammarane, oleanene, and ocotillol type tricyclic triterpenoids based on the aglycon structure. Based on the sugar moiety linked to C-3, C-20, and C-6, C-20, dammarane type was divided into protopanaxadiol (PPD) and protopanaxatriol (PPT). The effects of ginsenosides on skin disorders are noteworthy. They play antiaging roles by enhancing immune function, resisting melanin formation, inhibiting oxidation, and elevating the concentration of collagen and hyaluronic acid. Thus, ginsenosides have previously been widely used to resist skin diseases and aging. This review details the role of ginsenosides in the anti-skin aging process from mechanisms and experimental research.

A Study on Performance Evaluation based on Packet Dropping in ATM Network . New Scheme Proposal

  • Park, Seung-Seob;Yuk, Dong-Cheol
    • Journal of Navigation and Port Research
    • /
    • v.27 no.3
    • /
    • pp.283-288
    • /
    • 2003
  • Recently, the growth of applications and services over high-speed Internet increases, ATM networks as wide area back-bone has been a major solution. As the conventional TCP/IP suite is still the standard protocol used to support upper application on current. Internet, the issues regarding whether TCP/IP will operate efficiently on top of an ATM infrastructure and how to control its QoS still remain for studies. TCP uses a window-based protocol for flow control in the transport layer. When TCP uses the UBR service in ATM layer, the control method is only buffer management. If a cell is discarded in ATM layer, one whole packet of TCP will be lost; this fact occur the most TCP performance degradation. Several dropping strategies, such as Tail Drop, EPD, PPD, SPD, FBA, have been proposed to improve the TCP performance over ATM. In this paper, to improve the TCP performance, we propose a packet dropping scheme that is based on comparison with EPD, SPD and FBA. Our proposed scheme is applied to schemes discussed in the previous technology. Our proposed scheme does not need to know each connection's mean packet size. When the buffer exceeds the given threshold, it is based on comparison between the number of dropped packet and the approved packet. Our results are reported and discussed for comparing these discarding schemes under similar conditions. Although the number of virtual channel (VC) is increased, the simulation results showed that the proposed scheme can allocate more fairly each VC than other scheme.

Performance Evaluation of the Capillary Tube Radiant Floor Cooling & Heating System (모세유관 바닥복사 냉·난방 시스템의 성능평가)

  • Seo, Yu-jin;Kim, Taeyeon;Leigh, Seung-bok
    • KIEAE Journal
    • /
    • v.12 no.4
    • /
    • pp.89-95
    • /
    • 2012
  • At present, many countries are trying to reduce green gas emissions to mitigate the effects of these gases on climate change. Year after year, there have been efforts to cut energy use for heating and cooling. Heating and cooling systems, common in all forms of housing, are increasing due to the constant supply of new housing resulting from improvements in economic growth and the quality of life. Thus, studies related to the design of cooling and heating systems to improve energy efficiency are expanding. Among the new designs, radiant floor cooling and heating systems which use capillary tubes are becoming viable means of reducing energy use. Radiant floor cooling and heating systems which use capillary tubes are creative and sustainable systems in which cool and hot water is circulated into capillary tube which has small diameter. In this study, the cooling and heating performance of this type of capillary tube system is investigated in an experimental study and a simulation using TRNSYS. The results of the experimental study show that under a peak load, a capillary tube radiant floor cooling system using geothermal energy can achieve desired indoor temperature without an additional heat source. The set room air temperature is maintained while the floor surface temperature, PMV and PPD remain within the comfort range. Also, this system is more economic than a packaged air conditioner system due to its higher COP. The results of the simulation show that the capillary tube radiant floor heating system maintains set temperature more stable than a PB pipe radiant floor heating system due to its lower supply temperature of hot water. In terms of energy consumption, the capillary tube radiant floor heating system is more efficient than the PB pipe radiant floor heating system.

The Effect of Environmental Fine Bubble on the Production of Ginsenoside during the Growth Period of Ginseng Cultivation (인삼 재배시 생육기간 동안 환경적 요인인 미세기포수가 ginsenoside 생성에 미치는 영향)

  • Ahn, Chul-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.12
    • /
    • pp.1-7
    • /
    • 2017
  • This study was conducted to investigate changes in ginsenoside by continuously treating fine bubble, which are mainly used for environmental purification, in 2-year-old ginseng. The ginsenoside content and composition of ginseng leaves and roots were analyzed for 4 months (120 days) after application of Fine bubble. As a result of treatment with common water in leaves, only Re of protopanaxatriol was significantly higher and As a result of treatment with fine buble, it was confirmed that protopanaxadiol Rb1, RC, Rb2 and Rd components were also increased. Especially, the increase of Re and Rb1 resulted in an increase of total ginsenoside. The ratio of PD / PT to ginseng was 0.811 in finebubble treated leaves and 1.28 in root. The fine bubble treatment induced the synthesis of ginsenoside from the roots and resulted in a PD / PT ratio of close to 1. Therefore, this study suggests a method of cultivating high quality ginseng using fine bubble water and suggests possibility of using it as a functional food material which can be used with leaves as well as roots.

Drag Reduction of a Circular Cylinder With O-rings (O-ring을 이용한 원주의 항력감소에 관한 실험적 연구)

  • Lim, Hee-Chang;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.8
    • /
    • pp.1174-1181
    • /
    • 2003
  • The flow around a circular cylinder was controlled by attaching O-rings to reduce drag force acting on the cylinder. Four experimental models were tested in this study; one smooth cylinder of diameter D (D=60mm) and three cylinders fitted with O-rings of diameters d=0.0167 D, 0.05D and 0.067 D with pitches of PPD=2D, 1D, 0.5D and 0.25D. The drag force, mean velocity and turbulence Intensity profiles in the near wake behind the cylinders were measured for Reynolds numbers based on the cylinder diameter in the range of Re$_{D}$=7.8$\times$10$^3$~1.2$\times$10$^{5}$ . At Re$_{D}$=1.2$\times$10$^{5}$ , the cylinder fitted with O-rings of d=0.0167D in a pitch interval of 0.25D shows the maximum drag reduction of about 5.4%, compared that with the smooth cylinder. The drag reduction effect of O-rings of d=0.067D is not so high. For O-ring circulars, as the Reynolds number increases, the peak location of turbulence intensity shifts downstream and the peak magnitude is decreased. Flow field around the cylinders was visualized using a smoke-wire technique to see the flow structure qualitatively. The size of vortices and vortex formation region formed behind the O-ring cylinders are smaller, compared with the smooth cylinder.der.

A Study on the Wild Exochorda serratifolia for Landscape Horticuitural Cultivation (야생 가침박탈(Exochorda serratifolia)의 조경원예화에 관한 연구)

  • 이기선;한교필;박원조;김일섭
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.15 no.2
    • /
    • pp.139-148
    • /
    • 1987
  • Exochorda serratifolia, broad-leaved shrub has beautiful flowers and is resistant to cold, shade and decease. New this native plant is considered to be worth being exploited as the outstanding plant for landscaping and horticulture. So this study was executed to utilize Exochorda serratifolia as the planting material for landscaping and horticulture through the survey of its habitat environment and the experimennt of its seed physiology and germination, vegetative propagation, culture and utilization, etc.. The results are as follows ; 1. The color of the flower is white, blooming in the early and middle of May and the seeds ripen late in Sep.. 2. The elevation, elevation, gradient and direction of the native habitat were 250m, 20-25$^{\circ}$and northern side respectively. 3. The soil pH of the natural habitat was 5.3 and soil fertility was poor. 4. Exochorda serratifolia appeared as indicator within P. densiflora community and its neighboring species were Q. mongolica, Q. dentata, R. mucronulatum, L. obtusiloba, E. oxyphillus, C. heterolphylla, var thunbergii, etc.. 5. The optimum temperature for seed germination was found at 20$^{\circ}C$ and the longer the stratification period at 5$^{\circ}C$ was, the lower the germination rate was. 6. The treat merits of GA and Kinetin increased the seed germination rate, especially under the dark condition but their high concentrations decreased the seed germination rate. 7. The rooted rate of the greenwood cutting was the highest at IBA 100ppm plot of vermiculite bed but its high concentration decreased the rooted rate conspicuously. 8. In the tissue culture, the each 1.0 ppd plot of NAA, Kinetin and NAA 1.0ppm + Kinetin showed the best growth. And the mixture of NAA 1.0ppm and Kinetin showed better growth than the single treatment of NAA or Kinetin did. 9. Transplanted Exochorda serratifolia showed healthy growth with shaded environmental condition(42.1% light intensity), therefore they can be cultivated as a shade tolerant landscape plant. 10. It was considered that Exochorda serratifolia was applicable to group planting at shade places or under trees in parks, homes, etc..

  • PDF

Behavior of Formaldehyde Concentration by Temperature and Humidity of Indoor and Outdoor in Underground Shopping Center and Subway(II) (지하상가 실내외 및 지하철의 온도와 습도에 따른 Formaldehyde 거동(II))

  • 권우택
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.1
    • /
    • pp.67-75
    • /
    • 1994
  • Formaldehyde has been in widespread industrial use since World War II . Numerous sources of formaldehyde are present in the indoor environment. Additionally, the current trend toward tighter, more energy efficient buildings with lower ventilation rates has led to increase concentrations of this and other pollutants generated indoors. In this paper, the field survey was carried out once a month from January to MarctL 1994 to measure indoor and outdoor formaldehyde concentration in several underground locations in Seoul. The results could be summarized as follows : 1. At Yang- jae underground shopping center, the mean formaldehyde concentration was 77.8ppb for indoor and 68.4ppb for outdoor. At Ban- po underground shopping center, it was 175.8ppb for indoor and 127.3ppb for outdoor. At Jam- shil underground shop ping center, it was 135.2ppd for indoor and 34.6ppb for outdoor. Indoor the No.2 sub way line, it was 105.6ppb. The formaldehyde concentration using Berge equation was as follows : At Yang- jae underground shopping center, the mean formaldehyde concentration was 85.99ppb for indoor and 72.75ppb for outdoor At Ban- po underground shopping center, it was 254. 17ppb for indoor and 138.14ppb for outdoor. At Jam- shil underground shopping center, it was 249.13ppb for indoor and 36.87ppb for outdoor. Indoor the No.2 subway line, it was 131.73ppb. 3, The result of correlation analysis indicated that the relationship between temperature and formaldehyde concentration is very high( $\gamma $= 0.831 ∼ 0.974). 4. Also, the relationship between humidity and formaldehyde concentration is variant ($\gamma $ = 0.246 ∼0.999). 5. The mean formaldehyde concentration indoor and outdoor Ban- po underground shop ping center and indoor Jam- shil underground shopping center and indoor the No.2 sub way line exceed the American Society of Heating, Refrigeration, Air- conditioning Engineers( ASHRAE) stflndard of 100ppb(120 $\mu $g/m$^{3}$).

  • PDF

Asymmetrical diffuse Interstitial Lung Lesions with Multiple Lymphadenopathy (다발성 임파절 이상증을 동반한 비대칭적 폐 간질성 병변)

  • Lee, Kyung Sang;Yang, Suck Chul;Yoon, Ho Joo;Shin, Dong Ho;Park, Sung Soo;Lee, Jung Hee;Kim, Hyuk;Choi, Yo Won;Jeon, Seok Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.651-656
    • /
    • 1996
  • We have experienced a case of sarcoidosis appearing asymmetrical diffuse interstitial lung lesions with multiple lymphadenopathy. This patient was a 57 year-old female who had been in good health until 2 months ago. At that time she noted the onset of an exertional dyspnea and weakness. Pulmonary function tests showed moderate obstructive pattern with mild decreased DLco. In the chest CT, multiple lymphadenopathy with small nodular lesions are scattered, and the impression was a metastatic lymph nodes with lymphangitic carcinomatosis. In bronchofiberscopy, we noted luminal narrowing by extrinsic compression in the right middle and lower lobe bronchi. And microscopic examination of by bronchofiberscopic biopsy showed chronic inflammation. Thus we performed subcarinal and tight supraclaviclar lymph nodes aspiration biopsy cytology, and that revealed class 0 and class 1, respectively. Finally, we performed an excisional biopsy for the right scalene lymph node, which revealed the specimen as a noncaseating granuloma. The angiotensin convecting enzyme level was overt two folds compared to normal value. And the patient had negative PPD skin test and hyperglobulinemia. After 18 weeks treatment with prednisone, the signs and symptoms which the patient clad suffered from, disappeared.

  • PDF

A Numerical Study of Automotive Indoor Thermal Comfort Model According to Boarding Conditions and Parameters Related to HVAC (HVAC 관련 매개변수 및 탑승조건에 따른 자동차 실내의 온열쾌적성 평가모델에 관한 수치해석적 연구)

  • Yoon, Seong Hyun;Park, Jun Yong;Son, Deok Young;Choi, Yunho;Park, Kyungseok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.9
    • /
    • pp.979-988
    • /
    • 2014
  • Recently, the interest in the thermal comfort is ever increasing as the time people stay in the automobile is gradually increasing. So far, however, the cooling performance of the HVAC(heating and ventilation air conditioning) system is evaluated by thermal environment criteria such as indoor air velocity and temperature, not by a thermal comfort index. Furthermore, the precise criteria has not been established yet when the thermal comfort for the automobile is evaluated using numerical analysis. In this study, the numerical analysis of automobile indoor thermal comfort according to various parameters such as HVAC operating mode, airflow, passenger boarding conditions is performed during the HVAC system's initial operating time(20 minutes). The solar ray tracing model and S2S radiation model are used and validated to simulate an external heat source. Based on this study, an evaluation model which can predict the thermal comfort index for the combination of the above parameters is presented.