• Title/Summary/Keyword: power-saving modes

Search Result 26, Processing Time 0.021 seconds

Effects of intermittent effluent recycling on the performance of UASB process (간헐적인 유출수 반송이 UASB 반응조 운전효율에 미치는 영향)

  • 이헌모;양병수
    • Journal of Environmental Science International
    • /
    • v.2 no.4
    • /
    • pp.317-324
    • /
    • 1993
  • Effluent recycling effect on UASB reactor performances is known as an important operational factor. In the present study, the possibility of intermittent recycle in UASB process for saving the power consumption was examined at different organic loading and various operational modes in recycle time period. The organic removal efficiencies of the reactors operated with the intermittent effluent recycle were considerably higher compared to those without the effluent recycle. In the intermittent recycle mode, the organic removal efficiencies slightly decreased as the non-recycle time period in the operational mode increased. Proper ratio of recycle and non-recycle time period in the mode seemed to be required to prevent the produced biogas from accumulation in the sludge bed, which caused dead zone in the reactor and sludge loss when the gas was escaped from the bed at the certain pressure.

  • PDF

Experimental Test Results of Nine Scheduling Operational Modes of PV and Battery Hybrid System for the Development of Automatic Control Algorithm for Continual Operation without being shut-downed (태양광 배터리 Hybrid 전력공급시스템 9가지 운전 모드 시험결과 및 무고장 연속 운전을 위한 자동제어 알고리즘 개발)

  • Song, Taek Ho;Yang, Seung Kwon;Kim, Minjeong
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.1
    • /
    • pp.25-32
    • /
    • 2019
  • K-BEMS System was introduced to reduce peak load and to save total energy of the 200 buildings that KEPCO headquarter and branch offices use. And K-BEMS system is composed of PV, battery, and hybrid PCS. KEPCO research institute has carried out this K-BEMS research project for 3 years since January 2016. In this paper, the results of the project are shown. 9 modes of test results of K-BEMS system and are operational problems were analyzed. And measures to cure the trouble are also suggested. Batteries are operated more than 20% of SOC, and less than 20% of SOC battery protection switches are automatically shutting down the system and the system no longer respond to EMS, ending the supply of PV, and so therefore to continue the PV power supply it was turn out to be necessary that the EMS should automatically change its policy to change PV only supply mode automatically when the Battery Switch automatically operated. To operate the system continuously and automatically, it is necessary to modify the minimum operational SOC value, and in addition to that the EMS computer must remember the last shut-down SOC and Voltage which interrupted the system and add some margin to reflect the measurement error in the system.

Prediction of Power Consumption for Improving QoS in an Energy Saving Server Cluster Environment (에너지 절감형 서버 클러스터 환경에서 QoS 향상을 위한 소비 전력 예측)

  • Cho, Sungchoul;Kang, Sanha;Moon, Hungsik;Kwak, Hukeun;Chung, Kyusik
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.4 no.2
    • /
    • pp.47-56
    • /
    • 2015
  • In an energy saving server cluster environment, the power modes of servers are controlled according to load situation, that is, by making ON only minimum number of servers needed to handle current load while making the other servers OFF. This algorithm works well under normal circumstances, but does not guarantee QoS under abnormal circumstances such as sharply rising or falling loads. This is because the number of ON servers cannot be increased immediately due to the time delay for servers to turn ON from OFF. In this paper, we propose a new prediction algorithm of the power consumption for improving QoS under not only normal but also abnormal circumstances. The proposed prediction algorithm consists of two parts: prediction based on the conventional time series analysis and prediction adjustment based on trend analysis. We performed experiments using 15 PCs and compared performance for 4 types of conventional time series based prediction methods and their modified methods with our prediction algorithm. Experimental results show that Exponential Smoothing with Trend Adjusted (ESTA) and its modified ESTA (MESTA) proposed in this paper are outperforming among 4 types of prediction methods in terms of normalized QoS and number of good reponses per power consumed, and QoS of MESTA proposed in this paper is 7.5% and 3.3% better than that of conventional ESTA for artificial load pattern and real load pattern, respectively.

Design of LED Driving Circuit using Voltage Controlled Ring Oscillator and Lighting Controller (전압제어 링 발진기를 이용한 LED구동회로 및 조명제어기설계)

  • Kwon, Ki-Soo;Suh, Young-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.1-9
    • /
    • 2010
  • An LED driving and control circuit has been developed. The LED driver has a new PWM circuit for current control of LED columns with dimming, current and thermal control, and communication functions. The PWM circuit is composed of two ring oscillator and one counter which can be constructed using basic digital logic components. In addition, it has the functions of remote control mode such as ON, OFF, emergency and power saving modes by the serial communication. The PWM generator and control circuit have been designed and fabricated 0.35[${\mu}m$] Magnachip/Hynix digital IC fabrication process. The LED driving and control board using the developed chip is fabricated and tested successfully.

Simulation of Dynamic Characteristics of a Trigenerative Climate Control System Based On Peltier Thermoelectric Modules

  • Vasilyev, G.S.;Kuzichkin, O.R.;Surzhik, D.I.
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.6
    • /
    • pp.252-257
    • /
    • 2021
  • The application of the principle of trigeneration allows to simultaneously provide electricity to power electronic devices, as well as heat and cold to create the necessary microclimate of the premises and increase efficiency compared to separate cooling and heating systems. The use of Peltier thermoelectric modules (TEM) as part of trigenerative systems allows for smooth and precise control of the temperature regime, high manufacturability and reliability due to the absence of moving parts, resistance to shock and vibration, and small weight and size parameters of the system. One of the promising areas of improvement of trigenerative systems is their modeling and optimization based on the automatic control theory. A block diagram and functional model of an energy-saving trigenerative climate control system based on Peltier modules are developed, and the transfer functions of an open and closed system are obtained. The simulation of the transient characteristics of the system with varying parameters of the components is performed. The directions for improving the quality of transients in the climate control system are determined, as well as the prospects of the proposed methodology for modeling and analyzing control systems operating in substantially nonlinear modes.

Switching and Leakage-Power Suppressed SRAM for Leakage-Dominant Deep-Submicron CMOS Technologies (초미세 CMOS 공정에서의 스위칭 및 누설전력 억제 SRAM 설계)

  • Choi Hoon-Dae;Min Kyeong-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.3 s.345
    • /
    • pp.21-32
    • /
    • 2006
  • A new SRAM circuit with row-by-row activation and low-swing write schemes is proposed to reduce switching power of active cells as well as leakage one of sleep cells in this paper. By driving source line of sleep cells by $V_{SSH}$ which is higher than $V_{SS}$, the leakage current can be reduced to 1/100 due to the cooperation of the reverse body-bias. Drain Induced Barrier Lowering (DIBL), and negative $V_{GS}$ effects. Moreover, the bit line leakage which may introduce a fault during the read operation can be eliminated in this new SRAM. Swing voltage on highly capacitive bit lines is reduced to $V_{DD}-to-V_{SSH}$ from the conventional $V_{DD}-to-V_{SS}$ during the write operation, greatly saving the bit line switching power. Combining the row-by-row activation scheme with the low-swing write does not require the additional area penalty. By the SPICE simulation with the Berkeley Predictive Technology Modes, 93% of leakage power and 43% of switching one are estimated to be saved in future leakage-dominant 70-un process. A test chip has been fabricated using $0.35-{\mu}m$ CMOS process to verify the effectiveness and feasibility of the new SRAM, where the switching power is measured to be 30% less than the conventional SRAM when the I/O bit width is only 8. The stored data is confirmed to be retained without loss until the retention voltage is reduced to 1.1V which is mainly due to the metal shield. The switching power will be expected to be more significant with increasing the I/O bit width.