• Title/Summary/Keyword: power usage

Search Result 930, Processing Time 0.03 seconds

Power Tracing Method for Transmission Usage Allocation Considering Reactive Power

  • Han Choong-Kyo;Park Jong-Keun;Jung Hae-Sung
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.1
    • /
    • pp.79-84
    • /
    • 2005
  • In many countries, the electric power industry is undergoing significant changes known as deregulation and restructuring. These alterations introduce competition in generation and retail and require open access to the transmission network. The competition of the electric power industry causes many issues to surface. Among them, unbundling of the transmission service is probably the most complicated as it is a single and integrated sector and the transmission revenue requirement must be allocated to market participants in a fair way. In these situations, it is valuable to research the methodologies to allocate transmission usage. The power tracing method offers useful information such as which generators supply a particular load or how much each generator (load) uses a particular transmission line. With this information, we can allocate required transmission revenue to market participants. Recently, several algorithms were proposed for tracing power flow but there is no dominant power tracing method. This paper proposes a power tracing method based on graph theory and complex-current distribution. For practicability, the proposed method for transmission usage allocation is applied to IEEE 30 buses and compared with the method proposed by Felix F.Wu.

A Mathematical Approach to Allocate the Contributions by Applying UPFCs to Transmission System Usage

  • Sedaghati, Alireza
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.158-163
    • /
    • 2005
  • Competitive electricity markets necessitate equitable methods for allocating transmission usage in order to set transmission usage charges and congestion charges in an unbiased and an open-accessed basis. So in competitive markets it is usually necessary to trace the contribution of each participant to line usage, congestion charges and transmission losses, and then to calculate charges based on these contributions. A UPFC offers flexible power system control, and has the powerful advantage of providing, simultaneously and independently, real-time control of voltage, impedance and phase angle, which are the basic power system parameters on which sys-tem performance depends. Therefore, UPFC can be used efficiently and flexibly to optimize line utilization and increase system capability and to enhance transmission stability and dampen system oscillations. In this paper, a mathematical approach to allocate the contributions of system users and UPFCs to transmission system usage is presented. The paper uses a dc-based load flow modeling of UPFC-inserted transmission lines in which the injection model of the UPFC is used. The relationships presented in the paper showed modified distribution factors that modeled impact of utilizing UPFCs on line flows and system usage. The derived relationships show how bus voltage angles are attributed to each of changes in generation, injections of UPFC, and changes in admittance matrix caused by inserting UPFCs in lines. The relationships derived are applied to two test systems. The results illustrate how transmission usage would be affected when UPFC is utilized. The relationships derived can be adopted for the purpose of allocating usage and payments to users of transmission network and owners of UPFCs used in the network. The relationships can be modified or extended for other control devices.

  • PDF

3-Dimensional UAV Path Optimization Based on Battery Usage Prediction Model (배터리 사용량 예측 모델 기반 3차원 UAV 경로 최적화)

  • Kang, Tae Young;Kim, Seung Hoon;Park, Kyung In;Ryoo, Chang-Kyung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.12
    • /
    • pp.989-996
    • /
    • 2021
  • In the case of an unmanned aerial vehicle using a battery as a power source, there are restrictions in performing the mission because the battery capacity is limited. To extend the mission capability, it is important to minimize battery usage while the flight to the mission area. In addition, by using the battery usage prediction model, the possibility of mission completeness can be determined and it can be a criterion for selecting an emergent landing point in the mission planning stage. In this paper, we propose a battery usage prediction model considering as one of the environmental factors in the three-dimensional space. The required power is calculated according to the flight geometry of an unmanned aerial vehicle. True battery usage which is predicted from the required power is verified through the comparison with the battery usage prediction model. The optimal flight trajectory that minimizes battery usage is produced and compared with the shortest travel distance.

A Study on Electric Power Monitoring System per Appliance (기기별 전력 모니터링 시스템 개발에 관한 연구)

  • Park, Sung-Wook;Kim, Jong-Shick;Lim, Su-Jin;HwangBo, Sea-Hee;Son, Joon-Ik;Lee, In-Yong;Wang, Bo-Hyeun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.5
    • /
    • pp.638-644
    • /
    • 2010
  • This paper presents ideas of service scenarios for home residents using electric power monitoring system per appliance, the implementation of the monitoring system, and analysis of acquired electric power usage pattern. By acquiring and analyzing electric power usage pattern, home residents can get information of power usage pattern of every legacy (non-Demand Response-ready) appliance. Further they can get pieces of recommendation how to reduce energy consumption, intelligent standby power blocking service, and alarming service to abnormality of appliances. In order to check the feasibility of the ideas, a system that can acquire electric power pattern per appliance is implemented, and electric power pattern of some appliances are stored to a database and it was analyzed to show if auto-identification of a type of a device is possible, which is a basic required function for the scenarios presented.

Development of Adaptive Home Power Peak-Cut Control System Using Power Line Communication (전력선통신을 이용한 소규모 주택용 맞춤형 전력피크 제어시스템 개발)

  • Kim, Sang-Dong;Park, Ji-Ho;Kim, Dong-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.219-226
    • /
    • 2016
  • In this paper, adaptive home power peak-cut control system is developed using PLC. The developed scheme provides monitoring of power usage, power peak-cut control and additional function. In test bed, zone is presented by bedroom, living room, kitchen and bathroom. And individual load is presented by lighting, heater and fan in zone. In developed scheme, zone control is implemented by single PLC modem. And individual load control is implemented by key-map table. In addition, power peak-cut control system S/W, which can perform setting of power peak, power peak-cut control and monitoring of power usage.

Developing electric railway load pattern inspection program and optimizing power rate (전철변전소 전력부하패턴 점검 프로그램 개발 및 요금최적화)

  • Jeon, Yong-Joo;Lee, Gi-Chun;Park, Ki-Bum;Lee, Tae-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1163-1164
    • /
    • 2007
  • At present, one of the big characteristics in electric power market in korea is unique seller but in the near future competitions are expected in the market. so additional service for the electric power are expected. Also with development of IT technology, remote inspection for power usage are possible so as consumption pattern analysis. KORAIL is one of the biggest consumer in electric power market so it is necessary to investigate power consumption pattern. This paper presents electric power rate definition program based on billing system database and also basic power rate optimization method. Base on the substation annual power usage DB data, the characteristic of the substation power consumption are investigated and effective electrical billing system are compared each other. Through this program it is verified that we can save more then several hundred million won for a year.

  • PDF

Developing electric railway load pattern inspection program (전철 변전소 전력부하패턴 점검 프로그램 개발)

  • Jeon, Yong-Joo;Lee, Gi-Chun
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.893-898
    • /
    • 2007
  • At present, one of the big characteristics in electric power market in korea is unique seller but in the near future competitions are expected in the market. so additional service for the electric power are expected. Also with development of IT technology, remote inspection for power usage are possible so as consumption pattern analysis. KORAIL is one of the biggest consumer in electric power market so it is necessary to investigate power consumption pattern. This paper presents electric load consumption pattern for representative substation like urban subway, high-speed train, industrial line and simulation program for electric power rate definition program based on billing system database. Base on the substation annual power usage DB data, the characteristic of the substation power consumption are investigated and effective electrical billing system are compared each other. Through this program it is verified that we can save more then several hundred million won for a year.

  • PDF

A Study on Factors Influencing the Usage Level and Performance of EDI (EDI 활용수준 및 성과에 영향을 미치는 요인에 관한 연구)

  • Noh, Young;Chung, Yoon
    • Asia pacific journal of information systems
    • /
    • v.11 no.3
    • /
    • pp.105-126
    • /
    • 2001
  • The objective of research is to find out exogenous variables that influence the usage and performance EDI in the Korea firms. Specifically the goals of this research are; (1) to examine relationships between exogenous variables, such as management, technology, inter-firm relationship characteristics, and EDI performance, and (2) to measure EDI volume, EDI diversity, EDI depth among Korea firms. The questionnaire consists of two versions; One for the EDI system managers and the other for the EDI users. The analysis of this study is designed as cross level to examine the causal relationship among variables in different analysis level. The reliability and validity of data was tested by explanatory factor analysis, Cronbach's alpha coefficient, confirmatory factor analysis, and correlation analysis. Also, the structural equation model(SEM) analysis was performed to test the usefulness of the model. The analysis results revealed that education level, IS growth, trust, support, power are major influential variables on the usage level and performance of EDI. Especially, persuasive power turned out to be more important than coercive power, and technical financial support from organizations was also found to be a significant variables.

  • PDF

Effect of tunnel lighting replacement on power usage and illumination improvement: replacing low pressure sodium lamp with LED (터널 조명등 교체에 따른 전력사용량 및 조도 개선 효과: 저압나트륨램프 LED로 교체)

  • Lee, Gyu-Phil;Kim, Jeong-Heum
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.2
    • /
    • pp.185-196
    • /
    • 2020
  • Low-pressure sodium lamps, high-pressure sodium lamps and fluorescent lamps etc are mainly used tunnel lighting in Rep. of Korea. Power rates for tunnel lighting are known to account for the highest percentage in the tunnel maintenance costs. Therefore, tunnel lights are being replaced by LED that have advantages such as low power consumption and longevity. To analysis effect of replacement low pressure sodium lamp with LED, illumination and monthly power usage for a year are investigated for 8 tunnels. Power usage for tunnel lighting is decreased by 26.1% to 59.6%, and illumination is increased by 34.1% to 293% replacing low pressure sodium lamp with LED.

Unbalancing Voltage Control of LVDC Bipolar Distribution System for High Power Quality (전력 품질 향상을 위한 LVDC 양극성 배전 시스템의 불평형 전압 제어)

  • Lee, Hee-Jun;Shin, Soo-Choel;Kang, Jin-Wook;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.6
    • /
    • pp.486-496
    • /
    • 2016
  • The voltage unbalance of an LVDC bipolar distribution system was controlled for high power quality. Voltage unbalance may occur in a bipolar distribution system depending on the operation of the converter and load usage. Voltage unbalance can damage sensitive load and lead to converter accidents. The conditions that may cause voltage unbalance in a bipolar distribution system are as follows. First, three-level AC/DC converters in bipolar distribution systems can lead to voltage unbalance. Second, bipolar distribution systems can be at risk for voltage unbalance because of load usage. In this paper, the output DC link of a three-level AC/DC converter was analyzed for voltage unbalance, and the bipolar voltage was controlled with algorithms. In the case of additional voltage unbalance according to load usage, the bipolar voltage was controlled using the proposed converter. The proposed converter is a dual half-bridge converter, which was improved from the secondary circuit of a dual half-bridge converter. A control algorithm for bipolar voltage control without additional converters was proposed. The balancing control of the bipolar distribution system with distributed power was verified through experiments.