• Title/Summary/Keyword: power transmission system

검색결과 3,177건 처리시간 0.037초

다물체계 해석 방법을 이용한 동력전달계의 특성 해석 (Analysis on the Dynamic Characteristics of Power Transmission System Using Multi-body Dynamics)

  • 우민수;공진형;임원식
    • 한국자동차공학회논문집
    • /
    • 제12권6호
    • /
    • pp.175-181
    • /
    • 2004
  • This paper presents the main method to analyze the dynamic characteristics of power transmission system using the multi-body dynamics, which is based on the concept of subsystem equation, subsystem assembling, and the self-determination technique for the system degree of freedom. We can model the mechanical components of power transmission system easily with the advantage of multi-body dynamics. Based on the theory, a dynamic simulation program was developed to analyze system performances, transient phenomena, and other dynamic problems. The driving performance of automatic transmission was simulated with using the multi-body dynamics and Newtonian method, and the validity of program was proved by comparing the two kinds of result.

The Analysis Results of Lightning Overvoltages by EMTP for Lightning Protection Design of 500kV Substations

  • Ju Hyung-Jun;Lee Heung-Ho
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권4호
    • /
    • pp.366-370
    • /
    • 2005
  • To meet increasing power demand, 500 kV power systems are under consideration in the regions of some Middle Asian countries. As the power system voltage becomes higher, the cost for the power system insulation increases significantly. 500 kV transmission systems will become the basis of a region's power system and they require much higher system reliability. Consequently, by the methods of limiting overvoltages effectively, a reasonable insulation design and coordination must be accomplished. In particular, the Substations must be constructed to be of outdoor type. In order to determine the various factors for the insulation design, the EMTP (Electro-magnetic transient program) is used for the magnification of transient phenomena of the 500 kV systems in the planned network. In this paper, we will explain the calculation results of lightning overvoltages by the EMTP for lightning protection design for the 500 kV substations. To obtain reliable results, the multi-story tower model and EMTP/TACS model are introduced for the simulation of dynamic arc characteristics.

Stochastic Integrated Generation and Transmission Planning Incorporating Electric Vehicle Deployment

  • Moon, Guk-Hyun;Kong, Seong-Bae;Joo, Sung-Kwan;Ryu, Heon-Su;Kim, Tae-Hoon
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.1-10
    • /
    • 2013
  • The power industry is currently facing many challenges, due to the new environment created by the introduction of smart grid technologies. In particular, the large-scale deployment of electric vehicles (EVs) may have a significant impact on demand for electricity and, thereby, influence generation and transmission system planning. However, it is difficult to deal with uncertainties in EV charging loads using deterministic planning methods. This paper presents a two-stage stochastic decomposition method with Latin-hyper rectangle sampling (LHRS) to solve the integrated generation and transmission planning problem incorporating EV deployment. The probabilistic distribution of EV charging loads is estimated by Latin-hyper rectangle sampling (LHRS) to enhance the computational performance of the proposed method. Numerical results are presented to show the effectiveness of the proposed method.

파워시프트 변속기 유압클러치시스템의 해석적 연구 (An Analytical Investigation of a Hydraulic Clutch System of Powershift Transmission)

  • 이재천
    • 유공압시스템학회논문집
    • /
    • 제6권1호
    • /
    • pp.25-31
    • /
    • 2009
  • This study presents an analytical model of hydraulic clutch system of a power shift transmission to analyze pressure modulation characteristics. A typical hydraulic clutch system was modeled by using AMESim in which the parameters of major components were measured for simulation. Test apparatus was established using the components of power shift and power shuttle clutches with instrumental equipment. The results of simulation and experiment were so close that the proposed analytical model in this study was validated. However the cylinder model analogized clutch dynamics need to be improved in future study. The effects of parameters of orifice diameter, accumulator stroke and oil temperature on pressure modulation were analyzed respectively. The results of parameter sensitivity analysis show that modulation time and set pressure can be easily adjusted by changing parameter values. It is also found that the hydraulic clutch system used in this study is so susceptible to oil temperature that cooling equipment is necessary.

  • PDF

고온초전도 전력케이블 적용가능성 검토 (A Feasibility Study of HTS Power Cable in the Future)

  • 성기철;조전욱;권영길;류강식;강민규;유인근
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.125-127
    • /
    • 2000
  • In this study, we performed long lange power transmission expansion planning for conceptual design of HTS power cable in Seoul area. Since the HTS power cable has the high power transmission density and low loss characteristics in comparison with conventional power cables, the HTS power cable is introduced between the downtown and the suburbs in the future system in order to verify the feasibility of the HTS power transmission cables technically and to encourage the research activity in the area.

  • PDF

Direct Current Control Method Based On One Cycle Controller for Double-Frequency Buck Converters

  • Luo, Quanming;Zhi, Shubo;Lu, Weiguo;Zhou, Luowei
    • Journal of Power Electronics
    • /
    • 제12권3호
    • /
    • pp.410-417
    • /
    • 2012
  • In this paper, a direct current control method based on a one-cycle controller (DCOCC) for double frequency buck converters (DF buck) is proposed. This control method can make the average current through the high frequency and low frequency inductors of a DF buck converter equal. This is similar to the average current control method. However, the design of the loop compensator is much easier when compared with the average current control. Since the average current though the high frequency and low frequency inductors is equivalent, the current stress of the high frequency switches and the switch losses are minimized. Therefore, the efficiency of the DF buck converter is improved. Firstly, the operation principle of DCOCC is described, then the small signal models of a one cycle controller and a DF buck converter are presented based on the state space average method. Eventually, a system block diagram of the DCOCC controlled DF buck is established and the compensator is designed. Finally, simulation and experiment results are given to verify the correction of the theory analysis.

4방식 조향장치를 적용한 관리 작업차 개발 I(동력전달 시스템 개발) (Development of Working Tractor with Four-Type Wheel Steering System I(Development of Power Train System))

  • 조현덕
    • 한국공작기계학회논문집
    • /
    • 제14권1호
    • /
    • pp.66-72
    • /
    • 2005
  • The working tactor of this study, an agriculture machine, is consisted of 4 wheel driving system with gear trains and 4-type wheel steering system. Since technological regions for 4 wheel driving system and 4-type wheel steering system are some large, we divide on two studies on 4 wheel driving system and 4-type wheel steering system This study develops transmission and axle that are very important units for strong working operation because the power of tractor is largely affected by transmission and axle. Even if the development of the power train is some common technology, it is very complicated work and needs many experience know-hows. So, for new given specifications fitted to the working tractor, a kind of new agriculture machine, this study haws out processes that are development of assembly drawing and strength analysis through classical method and CAE software for all internal parts and housing cases.

모선 분리 운영중인 전력계통에 초전도 한류기 적용 효과 및 영향에 관한 연구 (A Study on the Effect of Superconducting Fault Current Limiter in Power System with Separated Bus and Superconducting Fault Current Limiter)

  • 김명현;김진석;임성훈;김재철
    • 조명전기설비학회논문지
    • /
    • 제26권12호
    • /
    • pp.74-79
    • /
    • 2012
  • Currently, separated buses were increased to limit a fault currents in power transmission system. However, separated buses caused bad influences such as a decrease of reliability and stability. Superconducting fault current limiter (SFCL) was proposed to limit a fault current lately and that has many merits beside any other solutions. Therefore, we proposed the install of Superconducting fault current limiter (SFCL) in power transmission system with separated bus. And our proposal was verified by reliability of power system.

A Simple Structure of Zero-Voltage Switching (ZVS) and Zero-Current Switching (ZCS) Buck Converter with Coupled Inductor

  • Wei, Xinxin;Luo, Ciyong;Nan, Hang;Wang, Yinghao
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1480-1488
    • /
    • 2015
  • In this paper, a revolutionary buck converter is proposed with soft-switching technology, which is realized by a coupled inductor. Both zero-voltage switching (ZVS) of main switch and zero-current switching (ZCS) of freewheeling diode are achieved at turn on and turn off without using any auxiliary circuits by the resonance between the parasitic capacitor and the coupled inductor. Furthermore, the peak voltages of the main switch and the peak current of the freewheeling diode are significantly reduced by the coupled inductor. As a result, the proposed converter has the advantages of simple circuit, convenient control, low consumption and so on. The detailed operation principles and steady-state analysis of the proposed ZVS-ZCS buck converter are presented, and detailed power loss analysis and some simulation results are also included. Finally, experimental results based on a 200-W prototype are provided to verify the theory and design of the proposed converter.

송전선로 DC화에 따른 융통조류 마진 분석 (Analysis of system power flow margin on replacement of transmission line to DC line)

  • 황성철;이재형;황평익;윤민한;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.420-421
    • /
    • 2015
  • Recently construction of new transmission line is getting harder because of social hostility to transmission tower. Howevere, load is converged in metropolitan area and power plants near this area are old and life of generator will end soon. Therefore, power to supply load in this area should be transmitted from east coast area and southern area. For these reasons, securement of transmission capacity without new transmission line construction is important. In this paper, effect of one circuit AC line change to DC transmission at the same transmission tower on the system available transfer capacity is analyzed.

  • PDF