• Title/Summary/Keyword: power system protection

Search Result 1,273, Processing Time 0.029 seconds

Fracture and Protection Technologies against Impulse of Power Arresters (전력용 피뢰기의 임펄스에 의한 파손과 대척 기술)

  • 한세원;조한구;김석수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.190-193
    • /
    • 2001
  • ZnO varistors have been widely used to protect power system and electronic system against overvoltages based on their excellent nonlinearity. In order to increase their protection capability, the fracture and protection technologies of arresters have to study according to their applications, namely ImA DC voltage, leakage currents, impulse residual voltages, withstanding capability to impulse surge, and energy absorption capability. ZnO varistors which have nonlinear current-voltage characteristic name a number of failure mechanism when ZnO elements absorb surge energies. Failure mode by thermal stress and Pin hole are among the most common failure mechanism at the high current surge current. In this study, the fracture mechaism of power arresters are introduced and protection technologies are researched. In particular the effect of thermal stress by surge currents to ZnO elements and methods against arc surge energy through withstand structure design of arrester are discussed.

  • PDF

Development of Distributive Independent IDPACS(Integrated Digital Protection And Control System) (분산 독립형 변전소 종합 보호 제어 시스템 개발)

  • Koh, Jae-Hak;Cho, Kyung-Lae;Ahn, Bog-Chan;Won, Hoi-Kwang;Lee, Kwon-Han;Cho, Nam-Gook;Shin, Hee-Seung
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.919-921
    • /
    • 1996
  • Recently, a growing demands on electricity require a high performance and reliable operation in the area of protection, control and monitoring of power plants and substations which may not provides with conventional systems. This paper describes a novel IDPACS (Integrated Digital Protection And Control System) in which we integrate all protection, control and monitoring function of the substations. The simulation results show that the proposed system provides fast response and reliable operation of power plant with superb performance on protection and control system.

  • PDF

TECHNICAL REVIEW ON THE LOCALIZED DIGITAL INSTRUMENTATION AND CONTROL SYSTEMS

  • Kwon, Kee-Choon;Lee, Myeong-Soo
    • Nuclear Engineering and Technology
    • /
    • v.41 no.4
    • /
    • pp.447-454
    • /
    • 2009
  • This paper is a technical review of the research and development results of the Korea Nuclear Instrumentation and Control System (KNICS) project and Nu-Tech 2012 program. In these projects man-machine interface system architecture, two digital platforms, and several control and protection systems were developed. One platform is a Programmable Logic Controller (PLC) for a digital safety system and another platform is a Distributed Control System (DCS) for a non-safety control system. With the safety-grade platform PLC, a reactor protection system, an engineered safety feature-component control system, and reactor core protection system were developed. A power control system was developed based on the DCS. A logic alarm cause tracking system was developed as a man-machine interface for APR1400. Also, Integrated Performance Validation Facility (IPVF) was developed for the evaluation of the function and performance of developed I&C systems. The safety-grade platform PLC and the digital safety system obtained approval for the topical report from the Korean regulatory body in February of 2009. A utility and vendor company will determine the suitability of the KNICS and Nu- Tech 2012 products to apply them to the planned nuclear power plants.

Specifications of 22.9kV HTS cables and FCLs considering protection systems in Korean power distribution system (국내계통 보호시스템을 고려한 22.9kV 초전도케이블/한류기 설계사양 제안)

  • Lee, Seung-Ryul;Park, Jong-Young;Yoon, Jae-Young;Lee, Byong-Jun;Yang, Byeong-Mo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.50-54
    • /
    • 2009
  • In Korea, 22.9kV 50MVA HTS (High Temperature Superconducting) cables and 630A/3kA hybrid SFCLs (Superconducting Fault Current Limiters) have been or are being developed by LS Cable, LS Industrial System, and Korea Electric Power Research Institute. They will be installed at Icheon 154kV Substation for real-power-distribution-system operation in 2010. This paper proposes specification of current limiting resistor/reactor for the SFCL and fault current condition of the HTS cable for applying the superconducting devices to Korean power distribution system, from the viewpoint of power system protection.

Long-term Radiation Dose Reduction Plan of KHNP

  • Kim, Saeng-Ki;Shin, Sang-Woon;Lim, Byoung-Chan
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.2
    • /
    • pp.137-143
    • /
    • 2003
  • Annual radiation dose limit to radiation worker was substantially lowered in Korea by the adoption of 1990 recommendations of the International Commission on Radiation Protection (ICRP 60) in its legislation. On the other hand, radiation management environment in nuclear power plants is getting more worse because of the accumulation of radiation sources inside the system and the frequent need for maintenance according as the operation years of nuclear power plants increase. Therefore, Korea Hydro & Nuclear power Co., Ltd. (KHNP) has established a long-term 10 years plan from 2001 to 2010 for the reduction of radiation dose to workers. The plan is aimed for the reduction of annual dose per unit averaged over 5 years from 0.9 man-Sv in 2001 to 0.75 man-Sv in 2010 by radiation source reduction, equipment/tool improvement or new equipment development for easy maintenance, and the improvement of administration and system.

Development of ACL Modul For Agent Communication in Auto-Adaptive OCR Agent (자율적응형 과전류계전기 에이전트의 통신을 위한 ACL모듈 개발)

  • Oh, T.W.;Lee, S.J.;Choi, M.S.;Kim, K.H.;Lim, S.I.;Min, B.W.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.193-195
    • /
    • 2002
  • In this paper, a communication module is proposed to be applied to communication between over current relay (OCR) agents in multi agent protection system. A multi agent system can achieve a global goal beyond the ability of each individual agent by working together, in which it is the prerequisite for each agent to be able to exchange or share information or processing status with other agent. The proposed communication module is purposed to enable not only each agent to bring about its own goal, but also the whole protective system to provide much improved coordinated protection. It is applied to a self adaptive protection system for a distribution network using multi agent concept to show its effectiveness.

  • PDF

Multi Function IGBT Gate Driver Including Arm Short Protection (Arm Short 보호 기능을 포함한 다기능 IGBT GATE DRIVER)

  • 이경복;조국춘;최종묵
    • Proceedings of the KSR Conference
    • /
    • 2000.05a
    • /
    • pp.202-209
    • /
    • 2000
  • This paper introduces the main function and protection method of IGBT gate driver that designed by KOROS. Recently, the applications of insulated gate bipolar transistors(IGBTs) have expanded widely, particularly in the area of railway converters. This driver is suitable for railway traction applications, so they are designed for circumstance of railway vehicle such as vibration. The input control power for this driver is supplied from battery charger of railway. it is no necessary an isolated power supply board or auxiliary power supply, with substantial savings in cost and space in railway applications. This gate driver can be used wide range of input voltage. So, performance of the driver has no relation with the battery voltage(70V∼110V). The protection methods of IGBT gate driver have many kind of ways, but this gate driver it designed to apply to converter for railway system, so this gate driver includes protection for arm short current and low control power voltage, etc. And the process of protection method and protection reference value are optimized by means of sufficient test with our own facilities.

  • PDF

Study on the Ground Fault Protection in 6.6KV Ungrounded Power System SGR Malfunction or Non-Tripping (선택지락보호계전기 오.부동작에 관한 연구)

  • Kim, Byung-Tae;Lee, Dal-Woo;Jeon, Myung-Soo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.296-301
    • /
    • 2008
  • This paper presents a study on the ground fault protection in 6.6KV ungrounded power system relay(SGR) malfunction or non-tripping. Ground test had made on 6.6KV HV(high voltage) system, Some of domestic and oversea's SGR products are different from their own specific characteristics. This study on the ground protection relay 6.6KV power supply system is focused to protect human.

Application of HVDC Protection in Jeju Test Bed. (HVDC Protection의 제주실증단지 적용)

  • Hwang, HoYoon;Lee, KyungBin;Lee, ChulKyun
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.100-101
    • /
    • 2014
  • HVDC의 보호요소 중 본 논문에서는 변환용 변압기부터 DC송전선로까지를 보호구간으로 삼는 DC Protection을 제주실증단지에 실제 적용시킨 사례에 대하여 기술한다. 보호구간은 어떻게 나뉘며 어떠한 보호요소들이 어떻게 동작하는지를 기술한다.

  • PDF

Application of Directional Over Current Protection Schemes Considering the Fault Characteristics in the Distribution System with Dispersed Generation (분산전원이 연계된 배전계통의 고장특성을 고려한 방향성 보호계전 방식 적용 연구)

  • Jung, Won-Wook;Lee, Hak-Ju;Kwon, Seong-Chul;Chae, Woo-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.97-107
    • /
    • 2010
  • Penetration of distributed generator(DG) to power distribution system can cause malfunction of existing protection schemes. Because grid interconnected DG can contribute fault currents and make bidirectional current flows on the system, fault contributions from DG can cause an interference of protection relay operation. Therefore, over current protection device of the distribution system with DGs need directional protection schemes. In this paper, improved directional protection algorithms are proposed for the distribution system with DG considering their fault characteristics. And than, these directional protection algorithms are tested and validated in various fault conditions. From the simulation results, it can be seen that the proposed directional protection algorithms are practically efficient for the radial distribution system with DG.